Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Thorac Cardiovasc Surg ; 68(2): 131-140, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-30060268

RESUMEN

BACKGROUND: The Mitroflow pericardial bioprosthesis (MPB) has been recently associated with a high incidence of early structural failures, questioning its validity as cardiac valve substitute. We have therefore reviewed our experience with this device. MATERIALS AND METHODS: A total of 398 patients with a mean age of 75 ± 7 years (58% above the age of 75 years) had aortic valve replacement with a Mitroflow prosthesis (2005-2015). Most patients had calcific aortic stenosis (86%) and were in sinus rhythm (89%). Mean EuroSCORE II was 5.5 ± 6.2. Mean follow-up was 4 ± 2 years (range: 4 months to 10 years), which was 100% complete. RESULTS: Hospital mortality was 6.5%; at discharge, 25% of patients had a moderate patient-prosthesis mismatch and none had a severe mismatch. Cumulative incidence of structural valve deterioration in the entire series was 2% (95% confidence interval [CI]: 1-4) at 5 years and 7% (95% CI: 4-14) at 8 years. Significant factors influencing MPB durability were age ≤ 65 years (p < 0.001) and the presence of patient-prosthesis mismatch (p = 0.01). No cases of structural valve deterioration were observed in patients with the new prosthetic model incorporating an anticalcification treatment the first 4 years of follow-up. CONCLUSIONS: The Mitroflow prosthesis has shown satisfactory results in the first decade of use. Durability appears adversely influenced by patient age and patient-prosthesis mismatch. Thus, a careful valve size selection and implantation in patients >65 years of age appears to be associated with excellent valve durability in the aortic position. Whether the new anticalcification treatment will provide a more durable prosthesis must be verified at a longer follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Bioprótesis , Calcinosis/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Pericardio/trasplante , Factores de Edad , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
2.
J Heart Valve Dis ; 25(4): 448-455, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-28009948

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The study aim was to evaluate the long-term clinical outcomes of the modified Bentall procedure (MBP) with a mechanical conduit. METHODS: Between 1993 and 2014, a total of 249 patients (mean age 62 ± 12 years; range: 25-87 years) underwent a MBP at the authors' institution. The main indication was annuloaortic ectasia in 102 patients (41%), followed by acute aortic dissection in 82 patients (33%); moderate to severe aortic regurgitation was present in 79% of cases. A bicuspid aortic valve was found in 17% of patients, and Marfan syndrome in 7%. The mean NYHA functional class was 2.5 ± 1.1. Concomitant procedures were performed in 36 patients (14%). The mean follow up was 8.7 ± 5.0 years (range: 0.3-21.5 years) and was 99% complete. The total follow up was 6.475 patient-years (pt-yr). RESULTS: Operative mortality was 3% in elective cases. Age, prolonged cardiopulmonary bypass times and mechanical ventilation >96 h were independent risk factors for early mortality. Actuarial survival at 15 and 20 years was 62% and 60%, respectively. Risk factors for late mortality were age and emergency operation. Actuarial freedom from thromboembolism (linearized incidence 0.93%/pt-yr) was 82% at 15 years, and 74% at 20 years. Seven patients required reoperation (0.38%/pt-yr), with an actuarial freedom from reoperation of 91% at 15 years and 87% at 20 years. The incidence of overall valve-related complications was 0.32%/pt-yr, with actuarial freedoms of 94% at 15 and 20 years. CONCLUSIONS: The MBP has shown excellent long-term results with a low incidence of procedure-related complications up to 20 years postoperatively. For this reason, it is considered to be a valid option for the treatment of aortic root disease, whenever valvesparing procedures are not indicated.


Asunto(s)
Aorta/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemorragia/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Tromboembolia/epidemiología , Factores de Tiempo
4.
Artículo en Inglés | MEDLINE | ID: mdl-38109676

RESUMEN

OBJECTIVES: Post-acute myocardial infarction mechanical complications (post-AMI MCs) represent rare but life-threatening conditions, including free-wall rupture, ventricular septal rupture and papillary muscle rupture. During the coronavirus disease-19 (COVID-19) pandemic, an overwhelming pressure on healthcare systems led to delayed and potentially suboptimal treatments for time-dependent conditions. As AMI-related hospitalizations decreased, limited information is available whether higher rates of post-AMI MCs and related deaths occurred in this setting. This study was aimed to assess how COVID-19 in Europe has impacted the incidence, treatment and outcome of MCs. METHODS: The CAUTION-COVID19 study is a multicentre retrospective study collecting 175 patients with post-AMI MCs in 18 centres from 6 European countries, aimed to compare the incidence of such events, related patients' characteristics, and outcomes, between the first year of pandemic and the 2 previous years. RESULTS: A non-significant increase in MCs was observed [odds ratio (OR) = 1.15, 95% confidence interval (CI) 0.85-1.57; P = 0.364], with stronger growth in ventricular septal rupture diagnoses (OR = 1.43, 95% CI 0.95-2.18; P = 0.090). No significant differences in treatment types and mortality were found between the 2 periods. In-hospital mortality was 50.9% and was higher for conservatively managed cases (90.9%) and lower for surgical patients (44.0%). Patients admitted during COVID-19 more frequently had late-presenting infarction (OR = 2.47, 95% CI 1.24-4.92; P = 0.010), more stable conditions (OR = 2.61, 95% CI 1.27-5.35; P = 0.009) and higher EuroSCORE II (OR = 1.04, 95% CI 1.01-1.06; P = 0.006). CONCLUSIONS: A non-significant increase in MCs incidence occurred during the first year of COVID-19, characterized by a significantly higher rate of late-presenting infarction, stable conditions and EuroSCORE-II if compared to pre-pandemic data, without affecting treatment and mortality.

5.
J Imaging ; 8(6)2022 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-35735949

RESUMEN

The potential of any multi-analytical and non-invasive approach to the study of cultural heritage, both for conservation and scientific investigation purposes, is gaining increasing interest, and it was tested in this paper, focusing on the panel painting Madonna della Tenda (Musei Reali, Turin), identified as a 16th-century copy of the painting by Raffaello Sanzio. As a part of a broader diagnostic campaign carried out at the Centro Conservazione e Restauro, La Venaria Reale in Turin, Italy, the potential of the combination of X-ray radiography, pulse-compression thermography, macro X-ray fluorescence, and IR reflectography was tested to investigate the wooden support and all the preparatory phases for the realization of the painting. The results of the optical microscopy and SEM/EDS analyses on a multi-layered micro-sample were used for a precise comparison, integration, and/or confirmation of what was suggested by the non-invasive techniques. Particularly, the radiographic and thermographic techniques allowed for an in-depth study of a hole, interestingly present on the panel's back surface, detecting the trajectory of the wood grain and confirming the presence of an old wood knot, as well as of a tau-shaped element-potentially a cracked and unfilled area of the wooden support-near the hollow. The combination of radiography, macro X-ray fluorescence, Near Infrared (NIR), and Short Wave Infrared (SWIR) reflectography allowed for an inspection of the ground layer, imprimitura, engravings, and underdrawing, not only revealing interesting technical-executive aspects of the artwork realization, but also highlighting the advantages of an integrated reading of data obtained from the different analytical techniques.

6.
Heart Views ; 22(3): 214-219, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34760055

RESUMEN

The neurofibromatosis is a large class of different genetic disorders: Neurofibromatosis type 1, type 2, type 3 (or Schwannomatosys), which have different clinical characterization. Neurofibromatosis type 1 (NF1), also known as Von Recklinghausen disease, represents 95% of the total cases. It is a complex autosomal dominant disorder with multisystem involvement, frequently associated to cardiac malformation. We present the case of a 52-years-old male affected by NF-1 with severe tricuspid regurgitation and atrial septal defect (ASD). No previous report about tricuspid valve surgery in NF-1 are available in the literature. A complete perioperative assessment was performed, including dermatologist evaluation, angio-CT scan and transesophageal echocardiography. The patient underwent uneventfully tricuspid valve replacement and ASD closure, with no wound complication even at 6-months follow-up. Treating congenital malformation in patient with complex genetic disorders like NF-1 is safe and can be resolutive, permitting to reduce long-term risk of complications for the patients. Preoperative assessments are fundamental, as well as in-hospital care and expertise on congenital heart defects.

7.
Aorta (Stamford) ; 5(5): 139-147, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29657952

RESUMEN

BACKGROUND: Patients with annuloaortic ectasia may be surgically treated with modified Bentall or David I valve-sparing procedures. Here, we compared the long-term results of these procedures. METHODS: A total of 181 patients with annuloaortic ectasia underwent modified Bentall (102 patients, Group 1) or David I (79 patients, Group 2) procedures from 1994 to 2015. Mean age was 62 ± 11 years in Group 1 and 64 ± 16 years in Group 2. Group 1 patients were in poorer health, with a lower ejection fraction and higher functional class. RESULTS: Early mortality was 3% in Group 1 and 2.5% in Group 2. Patients undergoing a modified Bentall procedure had a higher incidence of thromboembolism and hemorrhage, whereas those undergoing a David I procedure had a higher incidence of endocarditis. Actuarial survival was 70 ± 6% at 15 years in Group 1 and 84 ± 7% at 10 years in Group 2. Actuarial freedom from reoperation was 97 ± 2% at 15 years in Group 1 and 84 ± 7% at 10 years in Group 2. In Group 2, freedom from procedure-related reoperations was 98 ± 2% at 10 years. At last follow-up, no cases of moderate or severe aortic regurgitation were observed. CONCLUSIONS: The modified Bentall and David I procedures showed excellent early and late results. The modified Bentall procedure with a mechanical conduit was associated with thromboembolic and hemorrhagic complications, whereas the David I procedure was associated with unexplained occurrences of endocarditis. Thus, the David I procedure appears to be safe, reproducible, and capable of achieving stable aortic valve repair and is therefore our currently preferred solution for patients with annuloaortic ectasia. However, the much shorter follow-up for David I patients limits the strength of our comparison between the two techniques.

8.
Tex Heart Inst J ; 43(1): 13-9, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27047280

RESUMEN

We reviewed the cases of 100 patients (mean age, 73 ± 10 yr; 64 men) who had mitral valve replacement with a Medtronic Mosaic porcine bioprosthesis from 1995 through 2011. The mean New York Heart Association (NYHA) class was 3 ± 0.7, and 52 patients were in atrial fibrillation. Prosthetic sizes were chiefly 27 mm (50 patients) and 29 mm (40 patients). Follow-up ended in December 2012 and is 97% complete, with a cumulative duration of 611 patient-years (mean duration, 6 ± 4.6 yr; maximum, 17.7 yr). The early mortality rate was 10% (6% in elective patients); late deaths occurred in 31 patients (5 valve-related). Actuarial survival rates at 5, 10, and 15 years were 74% ± 5%, 50% ± 6%, and 37% ± 8%. The mean NYHA class in survivors was 1.4 ± 0.6 (P <0.0001). Thromboembolic episodes occurred in 4 patients, with an actuarial freedom at 15 years of 91% ± 5%. No cases of endocarditis were observed. Four patients needed reoperation, 2 for structural failure, and 1 each for perivalvular leakage and valve thrombosis. Actuarial freedom from structural failure and from reoperation, respectively, was 93% ± 5% and 91% ± 5% at 15 years. Echocardiographic follow-up in 24 patients with 27-mm prostheses showed a mean gradient of 5 ± 1.7 mmHg and an effective orifice area of 1.57 ± 0.3 cm(2); in 16 patients with 29-mm prostheses, the mean gradient was 4.5 ± 1.9 mmHg, and the effective orifice area, 1.63 ± 0.4 cm(2). During nearly 17 years of follow-up, the Mosaic bioprosthesis has shown good overall clinical and hemodynamic performance after mitral valve replacement.


Asunto(s)
Bioprótesis , Enfermedades de las Válvulas Cardíacas/cirugía , Hemodinámica/fisiología , Válvula Mitral/cirugía , Complicaciones Posoperatorias/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Animales , Ecocardiografía , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Pronóstico , Diseño de Prótesis , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Porcinos , Factores de Tiempo
9.
Ann Thorac Surg ; 102(3): e253-e255, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27549557

RESUMEN

In patients with infective endocarditis (IE), splenic involvement is a rare but well-known adverse event. The treatment of patients with IE and splenic abscesses is still challenging and controversial. We report 3 patients with IE and splenic abscesses who underwent successful valve replacement and splenectomy. Our experience confirms that in such a patient, a valve operation combined with splenectomy can be performed with excellent results during the same hospitalization. The timing of splenectomy and the type of surgical approach should be based mainly on the stability of a patient's hemodynamic condition.


Asunto(s)
Absceso/cirugía , Endocarditis/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Esplenectomía , Enfermedades del Bazo/cirugía , Absceso/diagnóstico por imagen , Anciano , Endocarditis/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedades del Bazo/diagnóstico por imagen , Tomografía Computarizada por Rayos X
10.
Cardiovasc Pathol ; 25(6): 500-502, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27619733

RESUMEN

Cardiac valve lipomatous hamartomas are very rare lesions with preferential localization on the pericardium, followed by the endocardial surfaces. We report a quite unique case of a lipomatous hamartoma-like lesion involving a bicuspid aortic valve. The lesion was incidentally found in a young patient undergoing cardiac surgery for aortic regurgitation, and the diagnosis was done by histology. It cannot be excluded that the lipomatous hamartoma-like lesion might have contributed to aortic valve regurgitation.


Asunto(s)
Válvula Aórtica/anomalías , Hamartoma/patología , Enfermedades de las Válvulas Cardíacas/patología , Lipomatosis/patología , Adulto , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Hallazgos Incidentales , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA