Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Am J Emerg Med ; 75: 59-64, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37922831

RESUMEN

INTRODUCTION: The quantification of blood loss in a severe trauma patient allows prognostic quantification and the engagement of adapted therapeutic means. The Advanced Trauma Life Support classification of hemorrhagic shock, based in part on hemodynamic parameters, could be improved. The search for reproducible and non-invasive parameters closely correlated with blood depletion is a necessity. An experimental model of controlled hemorrhagic shock allowed us to obtain hemodynamic and echocardiographic measurements during controlled blood spoliation. The primary aim was to demonstrate the correlation between the Shock Index (SI) and blood depletion volume (BDV) during the hemorrhagic phase of an experimental model of controlled hemorrhagic shock in piglets. The secondary aim was to study the correlations between blood pressure (BP) values and BDV, SI and cardiac output (CO), and pulse pressure (PP) and stroke volume during the same phase. METHODS: We analyzed data from 66 anesthetized and ventilated piglets that underwent blood spoliation at 2 mL.kg-1.min-1 until a mean arterial pressure (MAP) of 40 mmHg was achieved. During this bleeding phase, hemodynamic and echocardiographic measurements were performed regularly. RESULTS: The correlation coefficient between the SI and BDV was 0.70 (CI 95%, [0.64; 0.75]; p < 0.01), whereas between MAP and BDV, the correlation coefficient was -0.47 (CI 95%, [-0.55; -0.38]; p < 0.01). Correlation coefficient between SI and CO and between PP and stroke volume were - 0.45 (CI 95%, [-0.53; -0.37], p < 0.01) and 0.62 (CI 95%, [0.56; 0.67]; p < 0.01), respectively. CONCLUSIONS: In a controlled hemorrhagic shock model in piglets, the correlation between SI and BDV seemed strong.


Asunto(s)
Choque Hemorrágico , Animales , Humanos , Porcinos , Choque Hemorrágico/terapia , Hemorragia , Gasto Cardíaco , Hemodinámica , Presión Sanguínea/fisiología , Resucitación , Modelos Animales de Enfermedad
2.
Prehosp Emerg Care ; : 1-8, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37874044

RESUMEN

INTRODUCTION: Severe hemorrhage is the leading cause of early preventable death in severe trauma patients. Delayed diagnosis is a poor prognostic factor, and severe hemorrhage prediction is essential. The aim of our study was to investigate if there was an association between the detection of peritoneal or pleural fluid on prehospital sonography for trauma and posttraumatic severe hemorrhage. METHODS: We retrospectively studied data from records of thoracic or abdominal trauma patients managed in mobile intensive care units from January 2017 to December 2021 in four centers in France. Severe hemorrhage was defined as a condition necessitating transfusion of at least four packed red blood cells or surgical intervention/radioembolization for hemostasis within the first 24 h. Using a multivariate analysis, we investigated the predictive performance of focused assessment with sonography for trauma (FAST) alone or in combination with the five Red Flags criteria validated by Hamada et al. RESULTS: Among the 527 patients analyzed, 371 (71%) were men, the mean age was 41 ± 19 years, and the Injury Severity Score was 11 (Interquartile range = [5; 22]). Seventy-three (14%) patients had severe hemorrhage - of whom 28 (38%) had a positive FAST, compared to 61 (13%) without severe hemorrhage (p < 0.01). For severe hemorrhage prediction, FAST had a sensitivity of 38% (95%CI = [27%; 50%]) and a specificity of 87% (95%CI = [83%; 90%]) (AUC = 0.62, 95%CI = [0.57; 0.68]). The comparison of the other outcomes between positive and negative FAST was: hemostatic procedure, 22 (25%) vs 28 (6%), p < 0.01; intensive care unit admission 71 (80%) vs 190 (43%), p < 0.01; mean length of hospital stay 11 [4; 27] vs 4 [0; 14] days, p = 0.02; 30-day mortality 13 (15%) vs 22 (5%), p < 0.01. CONCLUSION: A positive FAST performed in the prehospital setting is associated with severe hemorrhage and all prognostic criteria we studied.

3.
Crit Care ; 25(1): 34, 2021 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-33482873

RESUMEN

BACKGROUND: Rapid response teams are intended to improve early diagnosis and intervention in ward patients who develop acute respiratory or circulatory failure. A management protocol including the use of a handheld ultrasound device for immediate point-of-care ultrasound (POCUS) examination at the bedside may improve team performance. The main objective of the study was to assess the impact of implementing such a POCUS-guided management on the proportion of adequate immediate diagnoses in two groups. Secondary endpoints included time to treatment and patient outcomes. METHODS: A prospective, observational, controlled study was conducted in a single university hospital. Two teams alternated every other day for managing in-hospital ward patients developing acute respiratory and/or circulatory failures. Only one of the team used an ultrasound device (POCUS group). RESULTS: We included 165 patients (POCUS group 83, control group 82). Proportion of adequate immediate diagnoses was 94% in the POCUS group and 80% in the control group (p = 0.009). Time to first treatment/intervention was shorter in the POCUS group (15 [10-25] min vs. 34 [15-40] min, p < 0.001). In-hospital mortality rates were 17% in the POCUS group and 35% in the control group (p = 0.007), but this difference was not confirmed in the propensity score sample (29% vs. 34%, p = 0.53). CONCLUSION: Our study suggests that protocolized use of a handheld POCUS device at the bedside in the ward may improve the proportion of adequate diagnosis, the time to initial treatment and perhaps also survival of ward patients developing acute respiratory or circulatory failure. Clinical Trial Registration NCT02967809. Registered 18 November 2016, https://clinicaltrials.gov/ct2/show/NCT02967809 .


Asunto(s)
Mortalidad/tendencias , Ultrasonografía/normas , Anciano , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Habitaciones de Pacientes/organización & administración , Habitaciones de Pacientes/estadística & datos numéricos , Sistemas de Atención de Punto/normas , Sistemas de Atención de Punto/estadística & datos numéricos , Estudios Prospectivos , Estadísticas no Paramétricas , Ultrasonografía/métodos , Ultrasonografía/estadística & datos numéricos
4.
Am J Emerg Med ; 49: 14-17, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34034203

RESUMEN

INTRODUCTION: Lung ultrasound is commonly used for the diagnosis of pneumothorax. However, recognition of pleural sliding is subjective and can be difficult for novice. The primary objective was to compare a novices physician's performance in diagnosing pneumothorax from ultrasound (US) scans either with visual evaluation or with maximum longitudinal pleural strain (MLPS). The secondary objective was to compare the diagnostic relevance of US with visual evaluation or MLPS to diagnose pneumothorax with an intermediately experienced and an expert physician. METHODS: We conducted a prospective, observational study in two emergency department and two intensive care unit, between February 2019 and June 2020. We included 99 adult patients with suspected pneumothorax, who received a chest computed tomography (CT). Three physicians with different experience of interpreting US scans (a novice physician, an intermediately experienced physician, and an expert) analyzed the US scans of 99 patients with suspected pneumothorax (50 (51%) with confirmed pneumothorax), which were confirmed by CT scan. RESULTS: With a threshold of 5%, the MLPS sensitivity was 94% (95% CI [83%; 98%]), and the specificity was 100% (95% CI [93%; 100%]). The novice physician had an area under the curve (AUC) with visual analysis of 0.75 (95% CI [0.67; 0.83]) vs 0.86 (95% CI [0.79; 0.94]) with MLPS (p = 0.04). The intermediate physician's AUC for diagnosing pneumothorax with visual analysis was 0.93 (95% CI [0.88; 0.99]) vs 1.00 (95% CI [1.00; 1.00]) with MLPS (p < 0.01) and for the expert physician it was 0.98 (95% CI [0.95;1.00]) vs 0.97 (95% CI [0.93; 1.00]), respectively (p = 0.69). CONCLUSION: In our study, speckle tracking analysis improved the accuracy of US for the novice and the intermediate but not the expert sonographer in the diagnosis of pneumothorax.


Asunto(s)
Neumotórax/diagnóstico por imagen , Neumotórax/diagnóstico , Ultrasonografía/normas , Adulto , Anciano , Área Bajo la Curva , Distribución de Chi-Cuadrado , Servicio de Urgencia en Hospital/organización & administración , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Neumotórax/fisiopatología , Estudios Prospectivos , Curva ROC , Estadísticas no Paramétricas , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía/métodos , Ultrasonografía/estadística & datos numéricos
5.
J Clin Ultrasound ; 49(8): 784-790, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34322891

RESUMEN

PURPOSE: Point-of-care ultrasound using a pocket-ultrasound-device (PUD) is increasing in clinical medicine but the optimal way to teach focused cardiac ultrasound is not clear. We evaluated whether teaching using a PUD or a conventional-ultrasound-device (CUD) is different when the final exam was conducted on a PUD. The primary aim was to compare the weighted total quality scale (WTQS, out of 100) obtained by participants in the two groups (CUD and PUD) on a live volunteer 2-4 weeks after their initial training. The secondary aims were to compare examination time and students' confidence levels (out of 50). METHODS: This bicentric, prospective single-blind randomized trial included undergraduate medical students. After watching a 15 min video about echocardiography views, students had a 45 min hands-on training session with a live volunteer using a PUD or a CUD. The final examination was conducted with a PUD on a live volunteer. RESULTS: Eighty-six comparable students were included, with 4 ± 1 years of medical training. In the PUD group, the mean WTQS was 65 ± 16 versus 60 ± 15 in the CUD group [p = 0.22; in multivariate analysis, OR 0.8 95% CI (0.1;1.6), p = 0.34]. The examination time was 10.0 [6.2-12.4] min in the PUD group versus 11.4 [7.3-13.2] in the CUD group (p = 0.39), while the confidence level was 27.9 ± 7.7 in the PUD group versus 27.4 ± 7.2 in the CUD group (p = 0.76). CONCLUSION: There was no difference between teaching echocardiographic views using a PUD as compared to a CUD on the PUD image quality, exam time, or confidence level of students.


Asunto(s)
Ecocardiografía , Estudiantes de Medicina , Competencia Clínica , Curriculum , Humanos , Estudios Prospectivos , Método Simple Ciego , Ultrasonografía
6.
J Clin Ultrasound ; 49(3): 212-217, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33196110

RESUMEN

INTRODUCTION: Ultrasound-guidance of radial artery catheter insertion improves the first attempt success and reduces the occurrence of hematomas. Needle-tracking devices optimize needle-ultrasound beam alignment by displaying in real-time the needle tip position. We compared the median time need by experienced physicians to achieve radial artery puncture using either a conventional ultrasonography device (CUD) or a magnetic needle-tracking ultrasound device (MUD) in a simulation training arm model. METHODS: Fifty experienced residents and physicians performed two punctures in randomized order with the CUD and the MUD. The primary outcome was puncture duration; the secondary outcomes were puncture success, rate of accidental vein puncture, and practitioner's comfort (subjective scale 0-10). RESULTS: The median [lower-upper quartile] puncture time was 10 [6-14] seconds when using CUD and 4 [3-7] seconds when using MUD (P < .01). In the multivariate analysis, MUD use was associated with decreased puncture duration whatever the puncture order (OR 1.13 [1.07-1.20], P < .01). The participants performed 99 (99%) successful punctures: 50 with the MUD (100%) and 49 with the CUD (98%). There was no accidental venous puncture. The practitioner's comfort level was 6.5 [6, 7] with the CUD and 8 [7-9] with the MUD (P < .01). CONCLUSION: MUD reduced radial artery puncture time and improved physician comfort in a simulation training arm model.


Asunto(s)
Fenómenos Magnéticos , Agujas , Punciones/instrumentación , Arteria Radial/diagnóstico por imagen , Arteria Radial/cirugía , Entrenamiento Simulado , Cirugía Asistida por Computador/educación , Femenino , Humanos , Masculino , Cirugía Asistida por Computador/instrumentación , Ultrasonografía
7.
J Clin Monit Comput ; 35(6): 1501-1510, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33216237

RESUMEN

Our main objective was to describe the course of GLS during the first days of septic shock and to assess the agreement between GLS values and longitudinal strain measured in apical four chambers. A prospective observational single centre study was conducted at the Nimes University Hospital's ICU. All patients admitted for a diagnosis of septic shock without pre-existing heart disease were eligible. Echocardiography (LVEF and GLS) was performed on the first day, and repeated once between day 3 and day 5 then once between day 6 and day 8. We enrolled 40 consecutive patients. Four patients were excluded. In overall population, GLS at T1 was impaired (- 11.0%, IQR(interquartile range) [- 15; - 10]). On T2 exams, a significant improvement of the GLS (- 11% vs - 16% p = 0.02) was observed whereas LVEF remained stable over time. A good agreement between GLS and longitudinal strain measured on a four chambers view was found. Based on the Bland and Altman method, the mean of differences for T1 exams was 0.1 (95% CI [- 0.6; 0.8]) with limits of agreement ranging from - 4 to 4. Myocardial strain is depressed at the early phase of septic shock and improves over time. A single measurement of LS4C view appears sufficient at bedside.


Asunto(s)
Choque Séptico , Disfunción Ventricular Izquierda , Ecocardiografía , Corazón , Humanos , Pronóstico , Estudios Prospectivos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
8.
Am J Emerg Med ; 38(10): 2081-2087, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-33142179

RESUMEN

INTRODUCTION: Ultrasound is a feasible and reproducible method for measuring right diaphragmatic excursion (RDE) in ED patients with acute dyspnea (AD). In AD patients, the correlation between the RDE value and the need for mechanical ventilation (MV) is not known. MATERIALS: This was a bicentric, observational prospective study. The RDE measurement was done at admission. The need for MV was defined by the use of MV within 4 h of AD management. An optimal threshold for RDE was determined as the value that minimized the incorrect predictions of the use of MV in the first 4 h as the highest Youden index. RESULTS: We analyzed 102 patients (79 [70; 86] years), 38 (37%) of whom had been ventilated. The RDE value was 1.7 cm [1.4; 2.0] and 2.2 cm [1.8; 2.6] in the ventilated and non-ventilated groups, respectively (p = 0.06). The AUC was 0.68 95% CI [0.57; 0.80]. With a threshold of 2 cm, the sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) were 76% [60%; 89%], 59% [46%; 71%], 81% [67%; 91%], and 53% [39%; 66%], respectively. In the non-COPD patients, the RDE values were 1.5 cm [1.2; 1.9] and 2.2 cm [1.8; 2.6] (p < 0.01) in the ventilated and not-ventilated groups, respectively. The AUC was 0.77 95% CI [0.64; 0.90]. With a threshold of 2.18 cm, the sensitivity, specificity, NPV, and PPV were 91% [71%; 99%], 51% [36%; 66%], 92% [75%; 99%], and 54% [38%; 69%], respectively. CONCLUSION: The RDE values at ED admission were unable to define a prognostic threshold value associated with subsequent MV need in the AD patients. In non-COPD patients, the NPV was 92%.


Asunto(s)
Diafragma/anomalías , Disnea/complicaciones , Respiración Artificial/métodos , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Diafragma/diagnóstico por imagen , Diafragma/fisiopatología , Disnea/fisiopatología , Servicio de Urgencia en Hospital/organización & administración , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Francia , Humanos , Modelos Logísticos , Masculino , Oportunidad Relativa , Estudios Prospectivos , Curva ROC , Ultrasonografía/métodos , Ultrasonografía/estadística & datos numéricos
9.
JAMA ; 324(19): 1948-1956, 2020 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-33201202

RESUMEN

Importance: Clinical guidelines for the early management of acute heart failure in the emergency department (ED) setting are based on only moderate levels of evidence, with subsequent low adherence to these guidelines. Objective: To test the effect of an early guideline-recommended care bundle on short-term prognosis in older patients with acute heart failure in the ED. Design, Setting, and Participants: Stepped-wedge cluster randomized trial in 15 EDs in France of 503 patients 75 years and older with a diagnosis of acute heart failure in the ED from December 2018 to September 2019 and followed up for 30 days until October 2019. Interventions: A care bundle that included early intravenous nitrate boluses; management of precipitating factors, such as acute coronary syndrome, infection, or atrial fibrillation; and moderate dose of intravenous diuretics (n = 200). In the control group, patient care was left to the discretion of the treating emergency physician (n = 303). Each center was randomized to the order in which they switched to the "intervention period." After the initial 4-week control period for all centers, 1 center entered in the intervention period every 2 weeks. Main Outcomes and Measures: The primary end point was the number of days alive and out of hospital at 30 days. Secondary outcomes included 30-day all-cause mortality, 30-day cardiovascular mortality, unscheduled readmission, length of hospital stay, and kidney impairment. Results: Among 503 patients who were randomized (median age, 87 years; 298 [59%] women), 502 were analyzed. In the intervention group, patients received a median (interquartile range) of 27.0 (9-54) mg of intravenous nitrates in the first 4 hours vs 4.0 (2.0-6.0) mg in the control group (adjusted difference, 23.8 [95% CI, 13.5-34.1]). There was a significantly higher percentage of patients in the intervention group treated for their precipitating factors than in the control group (58.8% vs 31.9%; adjusted difference, 31.1% [95% CI, 14.3%-47.9%]). There was no statistically significant difference in the primary end point of the number of days alive and out of hospital at 30 days (median [interquartile range], 19 [0- 24] d in both groups; adjusted difference, -1.9 [95% CI, -6.6 to 2.8]; adjusted ratio, 0.88 [95% CI, 0.64-1.21]). At 30 days, there was no significant difference between the intervention and control groups in mortality (8.0% vs 9.7%; adjusted difference, 4.1% [95% CI, -17.2% to 25.3%]), cardiovascular mortality (5.0% vs 7.4%; adjusted difference, 2.1% [95% CI, -15.5% to 19.8%]), unscheduled readmission (14.3% vs 15.7%; adjusted difference, -1.3% [95% CI, -26.3% to 23.7%]), median length of hospital stay (8 d in both groups; adjusted difference, 2.5 [95% CI, -0.9 to 5.8]), and kidney impairment (1% in both groups). Conclusions and Relevance: Among older patients with acute heart failure, use of a guideline-based comprehensive care bundle in the ED compared with usual care did not result in a statistically significant difference in the number of days alive and out of the hospital at 30 days. Further research is needed to identify effective treatments for acute heart failure in older patients. Trial Registration: ClinicalTrials.gov Identifier: NCT03683212.


Asunto(s)
Servicio de Urgencia en Hospital , Insuficiencia Cardíaca/mortalidad , Nitratos/administración & dosificación , Paquetes de Atención al Paciente , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Diuréticos/administración & dosificación , Femenino , Francia , Furosemida/administración & dosificación , Adhesión a Directriz , Insuficiencia Cardíaca/tratamiento farmacológico , Humanos , Infusiones Intravenosas , Masculino , Alta del Paciente , Guías de Práctica Clínica como Asunto
10.
Ann Emerg Med ; 73(6): 665-670, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30665773

RESUMEN

STUDY OBJECTIVE: To evaluate the diagnostic performance of chest ultralow-dose computed tomography (CT) compared with chest radiograph for minor blunt thoracic trauma. METHODS: One hundred sixty patients with minor blunt thoracic trauma were evaluated first by chest radiograph and subsequently with a double-acquisition nonenhanced chest CT protocol: reference CT and ultralow-dose CT with iterative reconstruction. Two study radiologists independently assessed injuries with a structured report and subjective image quality and calculated certainty of diagnostic confidence level. RESULTS: Ultralow-dose CT had a sensitivity and specificity of 100% compared with reference CT in the detection of injuries (187 lesions) in 104 patients. Chest radiograph detected abnormalities in 82 patients (79% of the population), with lower sensitivity and specificity compared with ultralow-dose CT (P<.05). Despite an only fair interobserver agreement for ultralow-dose CT image quality (κ=0.26), the diagnostic confidence level was certain for 95.6% of patients (chest radiograph=79.3%). Ultralow-dose CT effective dose (0.203 mSv [SD 0.029 mSv]) was similar (P=.14) to that of chest radiograph (0.175 mSv [SD 0.155 mSv]) and significantly less (P<.001) than that of reference CT (1.193 mSv [SD 0.459 mSv]). CONCLUSION: Ultralow-dose CT with iterative reconstruction conveyed a radiation dose similar to that of chest radiograph and was more reliable than a radiographic study for minor blunt thoracic trauma assessment. Radiologists, regardless of experience with ultralow-dose CT, were more confident with chest ultralow-dose CT than chest radiograph.


Asunto(s)
Servicio de Urgencia en Hospital , Radiografía Torácica , Traumatismos Torácicos/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Heridas no Penetrantes/diagnóstico por imagen , Humanos , Dosis de Radiación , Sensibilidad y Especificidad
11.
Prehosp Emerg Care ; 23(4): 543-550, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30457396

RESUMEN

Introduction: Several prehospital major trauma patient triage scores have been developed, the triage revised trauma score (T-RTS), Vittel criteria, Mechanism/Glasgow Coma Scale/Age/Systolic blood pressure score (MGAP), and the new trauma score (NTS). These scoring schemes allow a rapid and accurate prognostic assessment of the severity of potential lesions. The aim of our study was to compare these scores with in-hospital mortality predictions in a cohort of consecutive trauma patients admitted in a Level 1 trauma center. Materials: Between 2013 and 2016, 1,112 patients were admitted to the "major trauma" spinneret of a Level 1 trauma center in the south of France. All prehospital data needed to calculate the T-RTS, Vittel criteria, the MGAP score, and the NTS were collected. The main evaluation criterion was in-hospital mortality at 30 days for all causes. The predictive performances of these scores were evaluated and compared with each other using the analysis of the receiver operating curves. Results: A total of 1,001 patients were included in the analysis, 238 (24%) females, aged 43 ± 19 years with ISS 15 ± 13. The area under the curve was for each score: T-RTS, AUC = 0.84, [0.82-0.87]; Vittel criteria, AUC = 0.87 [0.85-0.89]; MGAP score, AUC = 0.91 [0.89-0.92] and NTS, AUC = 0.90 [0.88-0.92]. By comparing the ROC curves of these scores, the MGAP and NTS scores were statistically higher than the T-RTS. With the current thresholds, the sensitivity, specificity, positive and negative predictive values of these scores were 91%, 35%, 10%, 98% for T-RTS, 100%, 2%, 8%, 100% for Vittel criteria, 91%, 71%, 24%, 99% for MGAP score, 82%, 86%, 33%, 98% for NTS. Only Vittel's criteria allowed undertriage below 5% as recommended by the American College of Surgeons Committee on Trauma (ACSCOT). Conclusion: The comparison of these different triage scores concluded with a superiority of the MGAP and NTS scores compared with the T-RTS. Including the calculation of MGAP or NTS scores with the Vittel criteria would reduce the risk of overtriage in the Level 1 trauma centers by further directing patients at low risk of death to a lower-level trauma facility.


Asunto(s)
Servicios Médicos de Urgencia , Triaje , Heridas y Lesiones/mortalidad , Adolescente , Adulto , Anciano , Presión Sanguínea , Estudios de Cohortes , Femenino , Francia , Escala de Coma de Glasgow , Mortalidad Hospitalaria , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Curva ROC , Estudios Retrospectivos , Índices de Gravedad del Trauma , Heridas y Lesiones/diagnóstico , Heridas y Lesiones/terapia , Adulto Joven
12.
Air Med J ; 38(2): 100-105, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30898280

RESUMEN

OBJECTIVE: Minimizing out-of-hospital time reduces morbidity and mortality in patients with severe trauma, acute coronary syndrome, or acute stroke. Our objective was to compare out-of-hospital times by helicopter versus ground services when the estimated time of arrival on the scene was over 20 minutes. METHODS: We proposed a retrospective observational monocentric study following 2 cohorts. The helicopter group and the ground group included patients with severe trauma, acute coronary syndrome, or acute stroke transported by helicopter or ground services. RESULTS: Two hundred thirty-nine patients were included; 118 were in the ground group, and 121 were in the helicopter group. Distances for the helicopter group were higher (62.1 ± 22.5 km vs. 27.6 ± 10.4 km, P < .001). When distances were over 35 km, the helicopter group was faster. We identified distance, need for surgery, and intensive care hospitalization as 3 predicting factors for choosing helicopters over ground modes of transport. CONCLUSION: In cases of severe trauma, acute coronary syndrome, or acute stroke, emergency medical helicopter transport can be chosen over ground transport when patients are in a severe state and when the distance is further than 35 km from the hospital.


Asunto(s)
Síndrome Coronario Agudo , Ambulancias Aéreas/estadística & datos numéricos , Accidente Cerebrovascular , Heridas y Lesiones , Síndrome Coronario Agudo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Cuidados Críticos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Accidente Cerebrovascular/terapia , Factores de Tiempo , Heridas y Lesiones/cirugía
13.
Am J Emerg Med ; 36(9): 1597-1602, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29366658

RESUMEN

INTRODUCTION: Misdiagnosis in acute dyspneic patients (ADP) has consequences on their outcome. Lung ultrasound (LUS) is an accurate tool to improve diagnostic performance. The main goal of this study was to assess the determinants of increased diagnostic accuracy using LUS. MATERIALS: Multicentre, prospective, randomized study including emergency physicians and critical care physicians treating ADP on a daily basis. Each participant received three difficult clinical cases of ADP: one with only clinical data (OCD), one with only LUS data (OLD), and one with both. Ultrasound video loops of A, B and C profiles were associated with the cases. Which physician received what data for which clinical case was randomized. Physicians assessed the diagnostic probability from 0 to 10 for each possible diagnosis. The number of uncertain diagnoses (NUD) was the number of diagnoses with a diagnostic probability between 3 and 7, inclusive. RESULTS: Seventy-six physicians responded to the study cases (228 clinical cases resolved). Among the respondents, 28 (37%) were female, 64 (84%) were EPs, and the mean age was 37±8 years. The mean NUDs, respectively, when physicians had OCD, OLD, and both were 2.9±1.8, 2.2±1.7, 2.2±1.8 (p = 0.02). Ultrasound data and ultrasound frequency of use were the only variables related to the NUD. Higher frequency of ultrasound use by physicians decreased the number of uncertain diagnoses in difficult clinical cases with ultrasound data (OLD or associated with clinical data). CONCLUSION: LUS decreases the NUD in ADP. The ultrasound frequency of use decreased the NUD in ADP clinical cases with LUS data.


Asunto(s)
Disnea/diagnóstico por imagen , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedad Aguda , Adulto , Competencia Clínica/normas , Toma de Decisiones Clínicas , Cuidados Críticos , Errores Diagnósticos , Medicina de Emergencia/normas , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Marruecos , Médicos/normas , Sistemas de Atención de Punto , Pronóstico , Estudios Prospectivos , Ultrasonografía
14.
Am J Emerg Med ; 36(7): 1262-1264, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29653786

RESUMEN

INTRODUCTION: Compression ultrasonography (CUS) is a validated technique for the diagnosis of deep venous thrombosis (DVT), but has never been studied with pocket-sized ultrasound device (PUD). The main objective of this study was to assess the diagnostic performance of CUS made by emergency physicians (EPs) using a PUD. MATERIALS: This was a prospective, diagnostic test assessment, single-center study. Patients underwent VCU performed by a trained EP with PUD (CUS-PUD) for searching proximal DVT (PDVT) and were then seen by an expert vascular physician who blindly performed a duplex venous ultrasound, which was the criterion standard. CUS-PUD's diagnostic performance was evaluated by sensitivity (Se), specificity (Sp), and positive and negative predictive values (PPV and NPV). RESULTS: The sample included 57 patients of whom 56 were analyzed. Eleven (20%) PDVT were diagnosed with CUS-PUD: 7 (64%) femoral and 4 (36%) popliteal. The CUS-PUD's Se was 100% [72%; 100%], Sp 100% [92%; 100%]. The PPV was 100% [74%; 100%], and the NPV was 100% [90%; 100%]. CONCLUSION: CUS-PUD performed with a pocket-sized ultrasound appears to be feasible in emergency practice for the diagnosis of proximal DVT. A study with a larger sample size will have to describe the accuracy.


Asunto(s)
Servicio de Urgencia en Hospital , Vena Femoral/diagnóstico por imagen , Vena Poplítea/diagnóstico por imagen , Ultrasonografía/instrumentación , Trombosis de la Vena/diagnóstico , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Presión , Estudios Prospectivos , Reproducibilidad de los Resultados
15.
Am J Emerg Med ; 36(7): 1265-1269, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29650397

RESUMEN

INTRODUCTION: The present study was aimed at comparing the diagnosis concordance of five echo probes of lung ultrasound (LUS) with CT scans in intensive care and emergency patients with acute respiratory failure. MATERIALS: This prospective, observational, pilot study involved 10 acute patients in whom a thoracic CT scan was performed. An expert performed an LUS reference exam using five different probes: three probes with a high-quality conventional echo machine (cardiac phased-array probe, abdominal convex probe, linear probe) and two probes (cardiac and linear) with a pocket ultrasound device (PUD). Then, a trained physician and a resident performed 'blinded' analyses by viewing the video results on a computer. The primary objective was to test concordance between the blinded echo diagnosis and the CT scan. RESULTS: In the 100 LUS performed, the phased-array probe of the conventional machine and linear array probe of the PUD have the best concordance with the CT scan (Kappa coefficient=0.75 [CI 95%=0.54-0.96] and 0.62 [CI 95%=0.37-0.86], respectively) only for experts and trained physicians. The agreement was always poor for residents. Convex (abdominal) and linear transducers of conventional machines and the phased-array transducers (cardiac) of PUD have poor or very poor agreement, regardless of the physician's experience. CONCLUSION: Among the probes tested for LUS in acute patients, the cardiac probe of conventional machines and the linear probes of PUDs provide good diagnosis concordance with CT scans when performed by an expert and trained physician, but not by residents.


Asunto(s)
Cuidados Críticos/métodos , Enfermedad Crítica , Pulmón/diagnóstico por imagen , Sistemas de Atención de Punto , Transductores , Ultrasonografía/instrumentación , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Tomografía Computarizada por Rayos X
16.
J Clin Monit Comput ; 32(3): 513-518, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28710662

RESUMEN

Lung ultrasound (LUS) increases clinical diagnosis performance in intensive care unit (ICU). Real-time three-dimensional (3-D) imaging was compared with two-dimensional (2-D) LUS by assessing the global diagnosis concordance. In this single center, prospective, observational, pilot study, one trained operator performed a 3-D LUS immediately after a 2-D LUS in eight areas of interest on the same areas in 16 ventilated critically ill patients. All cine loops were recorded on a computer without visible link between 2-D and 3-D exams. Two experts blindly reviewed cine loops. Four main diagnoses were proposed: normal lung, consolidation, pleural effusion and interstitial syndrome. Fleiss κ and Cohen's κ values were calculated. In 252 LUS cine loops, the concordance between 2-D and 3-D exams was 83.3% (105/126), 77.6% (99/126) and 80.2% (101/126) for the trained operator and the experts respectively. The Cohen's κ coefficient value was 0.69 [95% Confidence Interval (CI) 0.58-0.80] for expert 1 meaning a substantial agreement. The inter-rater reliability was very good (Fleiss' κ value = 0.94 [95% CI 0.87-1.0]) for 3-D exams. The Cohen's κ was excellent for pleural effusion (κ= 0.93 [95% CI 0.76-1.0]), substantial for normal lung diagnosis (κ = 0.68 [95% CI 0.51-0.86]) and interstitial syndrome (κ = 0.62 [95% CI 0.45-0.80]) and fair for consolidation diagnoses (κ = 0.47 [95% CI 0.30-0.64]). In ICU ventilated patients, there was a substantial concordance between 2-D and 3-D LUS with a good inter-rater reliability. However, the diagnosis concordance for lung consolidation is poor.


Asunto(s)
Diagnóstico por Computador/métodos , Pulmón/diagnóstico por imagen , Adulto , Anciano , Algoritmos , Sistemas de Computación , Cuidados Críticos/métodos , Enfermedad Crítica , Femenino , Humanos , Imagenología Tridimensional , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Sistemas de Atención de Punto , Estudios Prospectivos , Reproducibilidad de los Resultados , Programas Informáticos , Ultrasonografía/métodos
17.
Anesthesiology ; 124(6): 1338-46, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27003619

RESUMEN

BACKGROUND: The collapsibility index of inferior vena cava (cIVC) is widely used to decide fluid infusion in spontaneously breathing intensive care unit patients. The authors hypothesized that high inspiratory efforts may induce false-positive high cIVC values. This study aims at determining a value of diaphragmatic motion recorded by echography that could predict a high cIVC (more than or equal to 40%) in healthy volunteers. METHODS: The cIVC and diaphragmatic motions were recorded for three levels of inspiratory efforts. Right and left diaphragmatic motions were defined as the maximal diaphragmatic excursions. Receiver operating characteristic curves evaluated the performance of right diaphragmatic motion to predict a cIVC more than or equal to 40% defining the best cutoff value. RESULTS: Among 52 included volunteers, interobserver reproducibility showed a generalized concordance correlation coefficient (ρc) above 0.9 for all echographic parameters. Right diaphragmatic motion correlated with cIVC (r = 0.64, P < 0.0001). Univariate analyses did not show association between cIVC and age, sex, weight, height, or body mass index. The area under the receiver operating characteristic curves for cIVC more than or equal to 40% was 0.87 (95% CI, 0.81 to 0.93). The best diaphragmatic motion cutoff was 28 mm (Youden Index, 0.65) with sensitivity of 89% and specificity of 77%. The gray zone area was 25 to 43 mm. CONCLUSIONS: Inferior vena cava collapsibility is affected by diaphragmatic motion. During low inspiratory effort, diaphragmatic motion was less than 25 mm and predicted a cIVC less than 40%. During maximal inspiratory effort, diaphragmatic motion was more than 43 mm and predicted a cIVC more than 40%. When diaphragmatic motion ranged from 25 to 43 mm, no conclusion on cIVC value could be done.


Asunto(s)
Diafragma/diagnóstico por imagen , Diafragma/fisiología , Respiración , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/fisiología , Adulto , Femenino , Humanos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Ultrasonografía
18.
Anesthesiology ; 125(2): 346-54, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27224640

RESUMEN

BACKGROUND: To assess the performance of transcranial Doppler (TCD) in predicting neurologic worsening after mild to moderate traumatic brain injury. METHODS: The authors conducted a prospective observational study across 17 sites. TCD was performed upon admission in 356 patients (Glasgow Coma Score [GCS], 9 to 15) with mild lesions on cerebral computed tomography scan. Normal TCD was defined as a pulsatility index of less than 1.25 and diastolic blood flow velocity higher than 25 cm/s in the two middle cerebral arteries. The primary endpoint was secondary neurologic deterioration on day 7. RESULTS: Twenty patients (6%) developed secondary neurologic deterioration within the first posttraumatic week. TCD thresholds had 80% sensitivity (95% CI, 56 to 94%) and 79% specificity (95% CI, 74 to 83%) to predict neurologic worsening. The negative predictive values and positive predictive values of TCD were 98% (95% CI, 96 to 100%) and 18% (95% CI, 11to 28%), respectively. In patients with minor traumatic brain injury (GCS, 14 to 15), the sensitivity and specificity of TCD were 91% (95% CI, 59 to 100%) and 80% (95% CI, 75 to 85%), respectively. The area under the receiver operating characteristic curve of a multivariate predictive model including age and GCS was significantly improved with the adjunction of TCD. Patients with abnormal TCD on admission (n = 86 patients) showed a more altered score for the disability rating scale on day 28 compared to those with normal TCD (n = 257 patients). CONCLUSIONS: TCD measurements upon admission may provide additional information about neurologic outcome after mild to moderate traumatic brain injury. This technique could be useful for in-hospital triage in this context. (Anesthesiology 2016; 125:346-54).


Asunto(s)
Lesiones Traumáticas del Encéfalo/complicaciones , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Enfermedades del Sistema Nervioso/diagnóstico por imagen , Enfermedades del Sistema Nervioso/etiología , Ultrasonografía Doppler Transcraneal/métodos , Adulto , Circulación Cerebrovascular , Determinación de Punto Final , Femenino , Escala de Coma de Glasgow , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
19.
Anesth Analg ; 123(1): 129-32, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27149016

RESUMEN

We hypothesized that placing the arm in 90° abduction, through 90° flexion and 90° external rotation, could improve ultrasound visualization of the subclavian vein. In 49 healthy volunteers, a single operator performed a view of the subclavian vein in neutral position and abduction position. A second blinded operator measured the cross-sectional area of the subclavian vein. Abduction position increased the cross-sectional area of the subclavian vein from 124 ± 46 (mean ± SD) to 162 ± 58 mm (P = 0.001). An increase of the cross-sectional area of ≥50% was observed in 41% volunteers (95% confidence interval, 27%-56%, n = 20); this technique offers an alternative approach (maybe safer) for ultrasound-guided catheterization of the subclavian vein.


Asunto(s)
Brazo/irrigación sanguínea , Voluntarios Sanos , Posicionamiento del Paciente , Vena Subclavia/diagnóstico por imagen , Ultrasonografía , Adulto , Puntos Anatómicos de Referencia , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Rango del Movimiento Articular , Reproducibilidad de los Resultados , Adulto Joven
20.
Am J Emerg Med ; 34(9): 1743-9, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27397668

RESUMEN

OBJECTIVE: This study aimed to compare 2 fluid infusion rates of lactated Ringer (LR) and hydroxyethyl starch (HES) 130/0.4 on hemodynamic restoration at the early phase of controlled hemorrhagic shock. METHODS: Fifty-six anesthetized and ventilated piglets were bled until mean arterial pressure (MAP) reached 40 mm Hg. Controlled hemorrhage was maintained for 30 minutes. After this period, 4 resuscitation groups were studied (n=14 for each group): HES infused at 1 or 4mL/kg per minute or LR1 infused at 1 or 4mL/kg per minute until baseline MAP was restored. Hemodynamic assessment using PiCCO monitoring and biological data were collected. RESULTS: Time to restore baseline MAP ±10% was significantly lower in LR4 group (11±11 minutes) compared to LR1 group (41±25 minutes) (P=.0004). Time to restore baseline MAP ±10% was significantly lower in HES4 group (4±3 minutes) compared to HES1 (11±4 minutes) (P=.0003). Time to restore baseline MAP ±10% was significantly lower with HES vs LR whatever the infusion rate. No statistically significant difference was observed in cardiac output, central venous saturation, extravascular lung water, and arterial lactate between 4 and 1 mL/kg per minute groups. CONCLUSIONS: In this controlled hemorrhagic shock model, a faster infusion rate (4 vs 1mL/kg per minute) significantly decreased the time for restoring baseline MAP, regardless of the type of infused fluid. The time for MAP restoration was significantly shorter for HES as compared to LR whatever the fluid infusion rate.


Asunto(s)
Presión Arterial , Fluidoterapia/métodos , Hemorragia/terapia , Derivados de Hidroxietil Almidón/administración & dosificación , Infusiones Intravenosas/métodos , Soluciones Isotónicas/administración & dosificación , Sustitutos del Plasma/administración & dosificación , Animales , Gasto Cardíaco , Hemodinámica , Masculino , Resucitación , Lactato de Ringer , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA