1.
Circulation ; 146(24): e334-e482, 2022 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-36322642

RESUMEN

AIM: The "2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease" provides recommendations to guide clinicians in the diagnosis, genetic evaluation and family screening, medical therapy, endovascular and surgical treatment, and long-term surveillance of patients with aortic disease across its multiple clinical presentation subsets (ie, asymptomatic, stable symptomatic, and acute aortic syndromes). METHODS: A comprehensive literature search was conducted from January 2021 to April 2021, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, CINHL Complete, and other selected databases relevant to this guideline. Additional relevant studies, published through June 2022 during the guideline writing process, were also considered by the writing committee, where appropriate. Structure: Recommendations from previously published AHA/ACC guidelines on thoracic aortic disease, peripheral artery disease, and bicuspid aortic valve disease have been updated with new evidence to guide clinicians. In addition, new recommendations addressing comprehensive care for patients with aortic disease have been developed. There is added emphasis on the role of shared decision making, especially in the management of patients with aortic disease both before and during pregnancy. The is also an increased emphasis on the importance of institutional interventional volume and multidisciplinary aortic team expertise in the care of patients with aortic disease.


Asunto(s)
Enfermedades de la Aorta , Enfermedad de la Válvula Aórtica Bicúspide , Cardiología , Femenino , Humanos , Embarazo , American Heart Association , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/terapia , Informe de Investigación , Estados Unidos
2.
J Cardiovasc Magn Reson ; 24(1): 12, 2022 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-35193584

RESUMEN

BACKGROUND: Significant aortic regurgitation (AR) leads to left ventricular (LV) remodeling; however, little data exist regarding sex-based differences in LV remodeling in this setting. We sought to compare LV remodeling and AR severity, assessed by echocardiography and cardiovascular magnetic resonance (CMR), to discern sex-based differences. METHODS: Patients with ≥ moderate chronic AR by echocardiography who underwent CMR within 90 days between December 2005 and October 2015 were included. Nonlinear regression models were built to assess the effect of AR regurgitant fraction (RF) on LV remodeling. A generalized linear model and Bland Altman analyses were constructed to evaluate differences between CMR and echocardiography. Referral for surgical intervention based on symptoms and LV remodeling was evaluated. RESULTS: Of the 243 patients (48.3 ± 16.6 years, 58 (24%) female), 119 (49%) underwent surgical intervention with a primary indication of severe AR, 97 (82%) men, 22 (18%) women. Significant sex differences in LV remodeling emerged on CMR. Women demonstrated significantly smaller LV end-diastolic volume index (LVEDVI) (96.8 ml/m2 vs 125.6 ml/m2, p < 0.001), LV end-systolic volume index (LVESVI) (41.1 vs 54.5 ml/m2, p < 0.001), blunted LV dilation in the setting of increasing AR severity (LVEDVI p value < 0.001, LVESVI p value 0.011), and LV length indexed (8.32 vs 9.69 cm, p < 0.001). On Bland Altman analysis, a significant interaction with sex and LV diameters was evident, demonstrating a significant increase in the difference between CMR and echocardiography measurements as the LV enlarged in women: LVEDVI (p = 0.006), LVESVI (p < 0.001), such that echocardiographic measurements increasingly underestimated LV diameters in women as the LV enlarged. LV length was higher for males with a linear effect from RF (p < 0.001), with LV length increasing at a higher rate with increasing RF for males compared to females (two-way interaction with sex p = 0.005). Sphericity volume index was higher for men after adjusting for a relative wall thickness (p = 0.033). CONCLUSIONS: CMR assessment of chronic AR revealed significant sex differences in LV remodeling and significant echocardiographic underestimation of LV dilation, particularly in women. Defining optimal sex-based CMR thresholds for surgical referral should be further developed. TRIAL REGISTRATION: NA.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Ecocardiografía , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Caracteres Sexuales , Función Ventricular Izquierda , Remodelación Ventricular
4.
Radiology ; 286(3): 1052-1061, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29156147

RESUMEN

Purpose To compare the diagnostic yield and complication rates of electromagnetic navigational bronchoscopic (ENB)-guided and computed tomography (CT)-guided percutaneous tissue sampling of lung nodules. Materials and Methods Retrospectively identified were 149 patients sampled percutaneously with CT guidance and 146 patients who underwent ENB with transbronchial biopsy of a lung lesion between 2013 and 2015. Clinical data, incidence of complications, and nodule pathologic analyses were assessed through electronic medical record review. Lung nodule characteristics were reviewed through direct image analysis. Molecular marker studies and pathologic analyses from surgical excision were reviewed when available. Multiple-variable logistic regression models were built to compare the diagnostic yield and complication rates for each method and for different patient and disease characteristics. Results CT-guided sampling was more likely to be diagnostic than ENB-guided biopsy (86.0% [129 of 150] vs 66.0% [99 of 150], respectively), and this difference remained significant even after adjustments were made for patient and nodule characteristics (P < .001). Age, American Society of Anesthesiologists class, emphysema grade, nodule size, and distance from pleura were not significant predictors of increased diagnostic yield. Intraprocedural time for physicians was significantly lower with CT-guided sampling (P < .001). Similar yield for molecular analyses was noted with the two approaches (ENB-guided sampling, 88.9% [32 of 36]; CT-guided sampling, 82.0% [41 of 50]). The two groups had similar rates of major complications (symptomatic hemorrhage, P > .999; pneumothorax requiring chest tube and/or admission, P = .417). Conclusion CT-guided transthoracic biopsy provided higher diagnostic yield in the assessment of peripheral pulmonary nodules than navigational bronchoscopy with a similar rate of clinically relevant complications. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Biopsia/métodos , Broncoscopía/métodos , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Masculino , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/patología , Radiografía Torácica , Estudios Retrospectivos , Adulto Joven
5.
J Vasc Interv Radiol ; 29(10): 1423-1428, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30174156

RESUMEN

The aim of this brief report is to determine the safety and reliability of minimally invasive video-assisted thoracic surgery (VATS) resection without the aid of intraoperative fluoroscopy after computed tomography (CT)-guided microcoil localization of small peripheral pulmonary nodules. Twenty patients with peripheral lung nodules underwent percutaneous needle localization with a microcoil that was tagged back to the visceral pleural surface. Same-day VATS resection was performed without the use of intraoperative fluoroscopy. All 20 nodules were successfully localized in the CT procedure room, and all 20 nodules were resected with negative margins and no major complications.


Asunto(s)
Nódulos Pulmonares Múltiples/diagnóstico por imagen , Nódulos Pulmonares Múltiples/cirugía , Nódulo Pulmonar Solitario/diagnóstico por imagen , Nódulo Pulmonar Solitario/cirugía , Cirugía Torácica Asistida por Video , Tomografía Computarizada por Rayos X/instrumentación , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Márgenes de Escisión , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Cirugía Torácica Asistida por Video/efectos adversos , Resultado del Tratamiento , Adulto Joven
8.
J Nucl Cardiol ; 23(5): 1102-1109, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-26071114

RESUMEN

INTRODUCTION: Although positron emission tomography PET-MR imaging is emerging into clinical practice, many aspects of this imaging technique such as attenuation correction have yet to be validated for myocardial imaging. Thus, it is uncertain whether PET-MR FDG images provide clinical information which is comparable to PET-CT FDG images. The study goal was to systematically compare relative myocardial FDG concentrations obtained from cardiac PET-MR images to those derived from same day PET-CT images. METHODS: Myocardial FDG images of 27 patients undergoing PET-CT imaging, followed by PET-MR imaging 42 ± 13 minutes later as part of a prospective oncology study were analyzed. Mean segmental standardized uptake measurements (SUVmean) were obtained in each of the 17 standard myocardial segments and normalized to the brightest segment. RESULTS: Normalized segmental SUVmean values did not differ significantly between the PET-MR and PET-CT images (mean difference 0.002, P = .826). The specific segment was a marginally significant predictor of the differences (P = .057), with the largest difference in the anteroseptal basal segment. CONCLUSIONS: PET-MR, vis-à-vis PET-CT, does not significantly raise segmental uptake relative to the brightest segment, suggesting that PET-MR can be used similarly to PET-CT for applications where relative uptake is important.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Fluorodesoxiglucosa F18/farmacocinética , Corazón/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Miocardio/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Adolescente , Adulto , Anciano , Simulación por Computador , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
10.
Radiographics ; 35(2): 327-56, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25763721

RESUMEN

Heart failure is recognized with increasing frequency worldwide and often progresses to an advanced refractory state. Although the reference standard for treatment of advanced heart failure remains cardiac transplantation, the increasing shortage of donor organs and the unsuitability of many patients for transplantation surgery has led to a search for alternative therapies. One such therapy is mechanical circulatory support, which helps relieve the load on the ventricle and thereby allows it to recover function. In addition, there is increasing evidence supporting the use of mechanical devices as a bridge to recovery in patients with acute refractory heart failure. In this article, the imaging evaluation of various commonly used short- and long-term cardiac assist devices is discussed, and their relevant mechanisms of action and physiology are described. Imaging, particularly computed tomography (CT), plays a crucial role in preoperative evaluation for assessment of candidacy for implantation of a left ventricular assist device (LVAD) or total artificial heart (TAH). Also, echocardiography and CT are indispensable in assessment of complications associated with cardiac devices. Complications commonly associated with short-term assist devices include bleeding and malpositioning, whereas long-term devices such as LVADs may be associated with infection, pump thrombosis, and cannula malfunction, as well as bleeding. CT is also commonly performed for preoperative planning before LVAD or TAH explantation, replacement of a device or one of its components, and cardiac transplantation. Online supplemental material is available for this article.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Ventrículos Cardíacos , Humanos , Diseño de Prótesis , Radiografía , Factores de Tiempo
11.
AJR Am J Roentgenol ; 203(4): 749-58, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25247940

RESUMEN

OBJECTIVE: Transcatheter aortic valve implantation has emerged as a viable treatment alternative for patients with severe aortic stenosis who are not surgical candidates. Multidimensional (3D and 4D) MDCT angiography plays a critical role in the safety, success, and outcome of an institutional transcatheter aortic valve implantation program. CONCLUSION: Given the increasing therapeutic role of this innovative technique, an understanding of essential imaging concepts in its context is critical for appropriate image acquisition and interpretation.


Asunto(s)
Angiografía/métodos , Cateterismo Cardíaco/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Tomografía Computarizada Multidetector/métodos , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Resultado del Tratamiento
12.
AJR Am J Roentgenol ; 203(6): 1181-91, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25415695

RESUMEN

OBJECTIVE: The purpose of this study was to investigate and validate adaptation of a cardiovascular CT angiography contrast injection protocol for lower tube potential. MATERIALS AND METHODS: Eighty-three patients evaluated for thoracic aortic disease with a 256-MDCT scanner were imaged at 120 kV (group 1) or 100 kV (group 2) with the same contrast protocol (90 mL iopromide 370 mg I/mL at 3.5 mL/s). A pharmacokinetic model was validated and used to simulate aortic attenuation in group 2 patients with 20%, 33%, and 44% reduction in contrast volume. A 44% volume reduction was applied to 50 additional patients who underwent imaging at 100 kV (group 3). Patient characteristics, scanning and radiation parameters, and objective and subjective image indexes were compared among groups. RESULTS: Group 2 patients had higher mean aortic blood attenuation (399±61 HU) than group 1 patients (281±48 HU) (p<0.001) but similar image noise. Group 3 and group 1 patients had similar mean aortic attenuation and noise. Subjective assessment of image quality indicated that group 3 and group 1 had comparable percentages of images with good or excellent diagnostic confidence scores (reader 1, 98% vs 96%; reader 2, 96% vs 96%). CONCLUSION: Lower tube potential (100 kV) for cardiothoracic CT could be accompanied by a 44% reduction in contrast volume with satisfactory aortic blood-pool attenuation in most patients. More personalized adaptation of the contrast protocol that takes into account patient characteristics and tube potential is necessary to ensure sufficient contrast enhancement for all patients.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Yohexol/análogos & derivados , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Enfermedades de la Aorta/metabolismo , Simulación por Computador , Medios de Contraste/administración & dosificación , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Yohexol/administración & dosificación , Yohexol/farmacocinética , Masculino , Persona de Mediana Edad , Modelos Biológicos , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Radiographics ; 34(6): 1612-35, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25310420

RESUMEN

Although 3-T magnetic resonance (MR) imaging is well established in neuroradiology and musculoskeletal imaging, it is in the nascent stages in cardiovascular imaging applications, and there is limited literature on this topic. The primary advantage of 3 T over 1.5 T is a higher signal-to-noise ratio (SNR), which can be used as such or traded off to improve spatial or temporal resolution and decrease acquisition time. However, the actual gain in SNR is limited by other factors and modifications in sequences adapted for use at 3 T. Higher resonance frequencies result in improved spectral resolution, which is beneficial for fat suppression and spectroscopy. The higher T1 values of tissues at 3 T aid in myocardial tagging, angiography, and perfusion and delayed-enhancement sequences. However, there are substantial challenges with 3-T cardiac MR imaging, including higher magnetic field and radiofrequency inhomogeneities and susceptibility effects, which diminish image quality. Off-resonance artifacts are particularly challenging, especially with steady-state free precession sequences. These artifacts can be managed by using higher-order shimming, frequency scouts, or low repetition times. B1 inhomogeneities can be managed by using radiofrequency shimming, multitransmit coils, or adiabatic pulses. Chemical shifts are also increased at 3 T. The higher radiofrequency results in higher radiofrequency deposition power and a higher specific absorption rate. MR angiography, dynamic first-pass perfusion sequences, myocardial tagging, and MR spectroscopy are more effective at 3 T, whereas delayed-enhancement, flow quantification, and black-blood sequences are comparable at 1.5 T and 3 T. Knowledge of the relevant physics helps in identifying artifacts and modifying sequences to optimize image quality. Online supplemental material is available for this article.


Asunto(s)
Cardiopatías/diagnóstico , Imagen por Resonancia Magnética/métodos , Artefactos , Medios de Contraste , Humanos , Imagen por Resonancia Magnética/instrumentación , Física , Relación Señal-Ruido
15.
Int J Cardiovasc Imaging ; 40(3): 665-673, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38286950

RESUMEN

Optimizing MRI aortic flow quantification is crucial for accurate assessment of valvular disease severity. In this study, we sought to evaluate the accuracy of a novel method of contouring systolic aortic forward flow in comparison to standard contouring methods at various aortic levels. The study included a cohort of patients with native aortic valve (AoV) disease and a small control group referred to cardiac MRI over a 1-year period. Inclusion criteria included aortic flow quantification at aortic valve and one additional level, and no or trace mitral regurgitation (MR) documented both by the MRI AND an echocardiogram done within a year. In addition to flow quantification with standard contouring (SC), a novel Selective Systolic Contouring (SSC) method was performed at aortic valve level, contouring the area demarcated by the AoV leaflets in systole. The bias in each technique's estimate of aortic forward flow was calculated as the mean difference between aortic forward flow and left ventricular stroke volume (LV SV). 98 patients (mean age 56, 71% male) were included: 33 with tricuspid and 65 with congenitally abnormal (bicuspid or unicuspid) AoV. All methods tended to underestimate aortic forward flow, but the bias was smallest with the SSC method (p < 0.001). Therefore, SSC yielded the lowest estimates of mitral regurgitant volume (4.8 ml) and regurgitant fraction (3.9%) (p < 0.05). SSC at AoV level better approximates LV SV in our cohort, and may provide more accurate quantitative assessment of both aortic and mitral valve function.


Asunto(s)
Enfermedad de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Humanos , Masculino , Persona de Mediana Edad , Femenino , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Volumen Sistólico , Válvula Aórtica/diagnóstico por imagen
16.
AMIA Jt Summits Transl Sci Proc ; 2024: 239-248, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38827049

RESUMEN

Clinical imaging is an important diagnostic test to diagnose non-ischemic cardiomyopathies (NICM). However, accurate interpretation of imaging studies often requires readers to review patient histories, a time consuming and tedious task. We propose to use time-series analysis to predict the most likely NICMs using longitudinal electronic health records (EHR) as a pseudo-summary of EHR records. Time-series formatted EHR data can provide temporality information important towards accurate prediction of disease. Specifically, we leverage ICD-10 codes and various recurrent neural network architectures for predictive modeling. We trained our models on a large cohort of NICM patients who underwent cardiac magnetic resonance imaging (CMR) and a smaller cohort undergoing echocardiogram. The performance of the proposed technique achieved good micro-area under the curve (0.8357), F1 score (0.5708) and precision at 3 (0.8078) across all models for cardiac magnetic resonance imaging (CMR) but only moderate performance for transthoracic echocardiogram (TTE) of 0.6938, 0.4399 and 0.5864 respectively. We show that our model has the potential to provide accurate pre-test differential diagnosis, thereby potentially reducing clerical burden on physicians.

17.
J Cardiovasc Magn Reson ; 15: 75, 2013 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-24006858

RESUMEN

BACKGROUND: Tetralogy of Fallot (TOF) repair and pulmonary valvotomy for pulmonary stenosis (PS) lead to progressive pulmonary insufficiency (PI), right ventricular enlargement and dysfunction. This study assessed whether pulmonary regurgitant fraction measured by cardiovascular magnetic resonance (CMR) could be reduced with inhaled nitric oxide (iNO). METHODS: Patients with at least moderate PI by echocardiography undergoing clinically indicated CMR were prospectively enrolled. Patients with residual hemodynamic lesions were excluded. Ventricular volume and blood flow sequences were obtained at baseline and during administration of 40 ppm iNO. RESULTS: Sixteen patients (11 with repaired TOF and 5 with repaired PS) completed the protocol with adequate data for analysis. The median age [range] was 35 [19-46] years, BMI was 26 ± 5 kg/m(2) (mean ± SD), 50% were women and 75% were in NYHA class I. Right ventricular end diastolic volume index for the cohort was 157 ± 33 mL/m(2), end systolic volume index was 93 ± 20 mL/m(2) and right ventricular ejection fraction was 40 ± 6%. Baseline pulmonary regurgitant volume was 45 ± 25 mL/beat and regurgitant fraction was 35 ± 16%. During administration of iNO, regurgitant volume was reduced by an average of 6 ± 9% (p=0.01) and regurgitant fraction was reduced by an average of 5 ± 8% (p=0.02). No significant changes were observed in ventricular indices for either the left or right ventricle. CONCLUSION: iNO was successfully administered during CMR acquisition and appears to reduce regurgitant fraction in patients with at least moderate PI suggesting a potential role for selective pulmonary vasodilator therapy in these patients. TRIALS REGISTRATION: ClinicalTrials.gov, NCT00543933.


Asunto(s)
Valvuloplastia con Balón/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Óxido Nítrico/administración & dosificación , Insuficiencia de la Válvula Pulmonar/tratamiento farmacológico , Estenosis de la Válvula Pulmonar/terapia , Válvula Pulmonar/efectos de los fármacos , Tetralogía de Fallot/cirugía , Vasodilatadores/administración & dosificación , Administración por Inhalación , Adulto , Femenino , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Ohio , Estudios Prospectivos , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Volumen Sistólico/efectos de los fármacos , Resultado del Tratamiento , Función Ventricular Izquierda/efectos de los fármacos , Función Ventricular Derecha/efectos de los fármacos , Adulto Joven
18.
AJR Am J Roentgenol ; 201(5): 971-6, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24147466

RESUMEN

OBJECTIVE: The purpose of this study was to compare high-pitch ECG-synchronized pulmonary CT angiography (CTA) with standard pulmonary CTA with regard to radiation dose and image quality in patients with suspected pulmonary embolism. SUBJECTS AND METHODS: This prospective study was approved by the institutional review board, and participants provided informed consent. Patients with suspected pulmonary embolism (60% women; mean age, 57 ± 14 years) were randomized to undergo high-pitch ECG-synchronized pulmonary CTA (n = 26) or standard pulmonary CTA (n = 21). Two independent readers assessed subjective image quality of pulmonary arteries, cardiovascular structures, and pulmonary parenchyma. Signal intensity (SI) was measured in one segmental and three central pulmonary arteries. RESULTS: High-pitch ECG-synchronized pulmonary CTA showed higher SI (p < 0.001) for pulmonary arteries. Image quality scores indicated improvement in assessment of cardio-vascular structures (p < 0.001), minimization of motion of central (p < 0.001) pulmonary arteries, and an increase in pulmonary arterial enhancement (p = 0.01) with high-pitch ECG-synchronized pulmonary CTA. Image quality scores for lung assessment were higher for standard pulmonary CTA (p < 0.001). The amount of contrast agent administered was similar between techniques (p = 0.86). Radiation dose was lower for high-pitch ECG-synchronized pulmonary CTA (p < 0.001). CONCLUSION: High-pitch ECG-synchronized pulmonary CTA provides higher pulmonary arterial SI, decreased motion of central pulmonary arteries, and improved assessment of cardiovascular structures with similar contrast dose and lower radiation compared with standard pulmonary CTA.


Asunto(s)
Angiografía/métodos , Técnicas de Imagen Sincronizada Cardíacas , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Electrocardiografía , Femenino , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador
19.
J Am Coll Radiol ; 20(11S): S501-S512, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-38040467

RESUMEN

This document discusses preprocedural planning for transcatheter aortic valve replacement, evaluating the imaging modalities used in initial imaging for preprocedure planning under two variants 1) Preintervention planning for transcatheter aortic valve replacement: assessment of aortic root; and 2) Preintervention planning for transcatheter aortic valve replacement: assessment of supravalvular aorta and vascular access. US echocardiography transesophageal, MRI heart function and morphology without and with IV contrast, MRI heart function and morphology without IV contrast and CT heart function and morphology with IV contrast are usually appropriate for assessment of aortic root. CTA chest with IV contrast, CTA abdomen and pelvis with IV contrast, CTA chest abdomen pelvis with IV contrast are usually appropriate for assessment of supravalvular aorta and vascular access. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Imagen por Resonancia Magnética , Sociedades Médicas , Tomografía Computarizada por Rayos X/métodos , Estados Unidos
20.
J Am Coll Radiol ; 20(11S): S351-S381, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-38040460

RESUMEN

Pediatric heart disease is a large and diverse field with an overall prevalence estimated at 6 to 13 per 1,000 live births. This document discusses appropriateness of advanced imaging for a broad range of variants. Diseases covered include tetralogy of Fallot, transposition of great arteries, congenital or acquired pediatric coronary artery abnormality, single ventricle, aortopathy, anomalous pulmonary venous return, aortopathy and aortic coarctation, with indications for advanced imaging spanning the entire natural history of the disease in children and adults, including initial diagnosis, treatment planning, treatment monitoring, and early detection of complications. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Asunto(s)
Enfermedad de la Arteria Coronaria , Cardiopatías , Adulto , Niño , Humanos , Diagnóstico Diferencial , Diagnóstico por Imagen/métodos , Sociedades Médicas , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA