Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Faraday Discuss ; 250(0): 9-42, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38380468

RESUMEN

While a substantial amount of research activity has been conducted in fields related to organic photonics and electronics, including the development of devices such as organic field-effect transistors, organic photovoltaics, and organic light-emitting diodes for applications encompassing organic thermoelectrics, organic batteries, excitonic organic materials for photochemical and optoelectronic applications, and organic thermoelectrics, this perspective review will primarily concentrate on the emerging and rapidly expanding domain of organic bioelectronics and neuromorphics. Here we present the most recent research findings on organic transistors capable of sensing biological biomarkers down at the single-molecule level (i.e., oncoproteins, genomes, etc.) for the early diagnosis of pathological states and to mimic biological synapses, paving the way to neuromorphic applications that surpass the limitations of the traditional von Neumann computing architecture. Both organic bioelectronics and neuromorphics exhibit several challenges but will revolutionize human life, considering the development of artificial synapses to counteract neurodegenerative disorders and the development of ultrasensitive biosensors for the early diagnosis of cancer to prevent its development. Moreover, organic bioelectronics for sensing applications have also triggered the development of several wearable, flexible and stretchable biodevices for continuous biomarker monitoring.


Asunto(s)
Técnicas Biosensibles , Electrónica , Humanos , Biomarcadores , Suministros de Energía Eléctrica , Sinapsis
2.
Chem Rev ; 122(4): 4636-4699, 2022 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-35077645

RESUMEN

Bioelectronic transducing surfaces that are nanometric in size have been the main route to detect single molecules. Though enabling the study of rarer events, such methodologies are not suited to assay at concentrations below the nanomolar level. Bioelectronic field-effect-transistors with a wide (µm2-mm2) transducing interface are also assumed to be not suited, because the molecule to be detected is orders of magnitude smaller than the transducing surface. Indeed, it is like seeing changes on the surface of a one-kilometer-wide pond when a droplet of water falls on it. However, it is a fact that a number of large-area transistors have been shown to detect at a limit of detection lower than femtomolar; they are also fast and hence innately suitable for point-of-care applications. This review critically discusses key elements, such as sensing materials, FET-structures, and target molecules that can be selectively assayed. The amplification effects enabling extremely sensitive large-area bioelectronic sensing are also addressed.


Asunto(s)
Técnicas Biosensibles , Transistores Electrónicos , Técnicas Biosensibles/métodos , Nanotecnología
3.
Anal Bioanal Chem ; 414(18): 5657-5669, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35410389

RESUMEN

Early diagnosis in a premalignant (or pre-invasive) state represents the only chance for cure in neoplastic diseases such as pancreatic-biliary cancer, which are otherwise detected at later stages and can only be treated using palliative approaches, with no hope for a cure. Screening methods for the purpose of secondary prevention are not yet available for these cancers. Current diagnostic methods mostly rely on imaging techniques and conventional cytopathology, but they do not display adequate sensitivity to allow valid early diagnosis. Next-generation sequencing can be used to detect DNA markers down to the physical limit; however, this assay requires labeling and is time-consuming. The additional determination of a protein marker that is a predictor of aggressive behavior is a promising innovative approach, which holds the potential to improve diagnostic accuracy. Moreover, the possibility to detect biomarkers in blood serum offers the advantage of a noninvasive diagnosis. In this study, both the DNA and protein markers of pancreatic mucinous cysts were analyzed in human blood serum down to the single-molecule limit using the SiMoT (single-molecule assay with a large transistor) platform. The SiMoT device proposed herein, which exploits an inkjet-printed organic semiconductor on plastic foil, comprises an innovative 3D-printed sensing gate module, consisting of a truncated cone that protrudes from a plastic substrate and is compatible with standard ELISA wells. This 3D gate concept adds tremendous control over the biosensing system stability, along with minimal consumption of the capturing molecules and body fluid samples. The 3D sensing gate modules were extensively characterized from both a material and electrical perspective, successfully proving their suitability as detection interfaces for biosensing applications. KRAS and MUC1 target molecules were successfully analyzed in diluted human blood serum with the 3D sensing gate functionalized with b-KRAS and anti-MUC1, achieving a limit of detection of 10 zM and 40 zM, respectively. These limits of detection correspond to (1 ± 1) KRAS and (2 ± 1) MUC1 molecules in the 100 µL serum sample volume. This study provides a promising application of the 3D SiMoT platform, potentially facilitating the timely, noninvasive, and reliable identification of pancreatic cancer precursor cysts.


Asunto(s)
Quiste Pancreático , Proteínas Proto-Oncogénicas p21(ras) , Biomarcadores , Humanos , Quiste Pancreático/diagnóstico , Quiste Pancreático/metabolismo , Quiste Pancreático/patología , Neoplasias Pancreáticas , Plásticos , Impresión Tridimensional , Neoplasias Pancreáticas
4.
Chemphyschem ; 22(19): 1967-1975, 2021 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-34309163

RESUMEN

Alginate composite hydrogels that exhibit highly sensitive stimuli-responsive behavior were used for signal-stimulated release of pre-loaded insulin. The alginate pores, particularly located at the periphery, were blocked by interpenetration of polyvinyl alcohol (PVA) cross-linked with 1,3-benzenediboronic acid (IPN), thus, significantly reducing uncontrolled leakage of the entrapped biomolecules. The beads were loaded with insulin and various enzymes mimicking different Boolean logic gates (AND, OR, NOR, IMP, INHIB). The enzymes were activated with biologically relevant input signals applied in four logic combinations: 0,0; 1,0; 0,1; 1,1, having the production of H2 O2 as the result of the biocatalytic reactions. The "successful" combination of the input signals leading to the H2 O2 production was different for different logic gates, following the corresponding truth tables of the logic gates. When H2 O2 was produced, boronate ester bonds were oxidized and the IPN was irreversibly degraded, thus re-opening the original pores of the hydrogel. This process allowed release of insulin from the alginate beads. The smart soft material that we have developed tackled well-known limitations of these systems and it may prove valuable in future medical diagnostics or treatments.


Asunto(s)
Alginatos/química , Hidrogeles/química , Ácidos Borónicos/química , Peróxido de Hidrógeno/química , Estructura Molecular , Alcohol Polivinílico/química
5.
Chemphyschem ; 21(19): 2150-2154, 2020 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-32797657

RESUMEN

The enzyme system mimicking Implication (IMPLY) and Inhibition (INHIB) Boolean logic gates has been designed. The same enzyme system was used to operate as the IMPLY or INHIB gate simply by reformulating the input signals. The optical analysis of the logic operation confirmed the output generation as expected for the studied logic gates. The conceptual approach to the IMPLY and INHIB logic gates allows their construction with many other enzymes operating in a similar way.


Asunto(s)
Inhibidores Enzimáticos/farmacología , Glucosa Oxidasa/antagonistas & inhibidores , Hexoquinasa/antagonistas & inhibidores , Peroxidasa de Rábano Silvestre/antagonistas & inhibidores , Oxigenasas de Función Mixta/antagonistas & inhibidores , Aspergillus niger/enzimología , Biocatálisis , Glucosa Oxidasa/metabolismo , Hexoquinasa/metabolismo , Peroxidasa de Rábano Silvestre/metabolismo , Oxigenasas de Función Mixta/metabolismo , Pediococcus/enzimología , Saccharomyces cerevisiae/enzimología
6.
Chemphyschem ; 21(1): 120-128, 2020 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-31408568

RESUMEN

Biocatalytic buckypaper electrodes modified with pyrroloquinoline quinone (PQQ)-dependent glucose dehydrogenase and bilirubin oxidase for glucose oxidation and oxygen reduction, respectively, were prepared for their use in a biofuel cell. A small (millimeter-scale; 2×3×2 mm3 ) enzyme-based biofuel cell was tested in a model glucose-containing aqueous solution, in human serum, and as an implanted device in a living gray garden slug (Deroceras reticulatum), producing electrical power in the range of 2-10 µW (depending on the glucose source). A microelectronic temperature-sensing device equipped with a rechargeable supercapacitor, internal data memory and wireless data downloading capability was specifically designed for activation by the biofuel cell. The power management circuit in the device allowed the optimized use of the power provided by the biofuel cell dependent on the sensor operation activity. The whole system (power-producing biofuel cell and power-consuming sensor) operated autonomously by extracting electrical energy from the available environmental source, as exemplified by extracting power from the glucose-containing hemolymph (blood substituting biofluid) in the slug to power the complete temperature sensor system and read out data wirelessly. Other sensor systems operating autonomously in remote locations based on the concept illustrated here are envisaged for monitoring different environmental conditions or can be specially designed for homeland security applications, particularly in detecting bioterrorism threats.


Asunto(s)
Fuentes de Energía Bioeléctrica , Biocombustibles , Técnicas Biosensibles , Animales , Gastrópodos , Glucosa 1-Deshidrogenasa/metabolismo , Humanos , Hypocreales/enzimología , Masculino , Microelectrodos , Oxidación-Reducción , Oxidorreductasas actuantes sobre Donantes de Grupo CH-CH/metabolismo , Cofactor PQQ/química , Cofactor PQQ/metabolismo
7.
Chemphyschem ; 21(7): 578, 2020 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-32237109

RESUMEN

The front cover artwork is provided by groups of Prof. Evgeny Katz and Prof. Artem Melman (Clarkson University, NY, USA) as well as Prof. Kirill Alexandrov (Queensland University of Technology, Brisbane, Australia). The image shows activation/inhibition of a chimeric enzyme with biomolecular signals and a corresponding logic network - the artistic vision. Read the full text of the Communication at 10.1002/cphc.201901050.

8.
Chemphyschem ; 21(7): 589-593, 2020 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-31755204

RESUMEN

Reactions catalyzed by artificial allosteric enzymes, chimeric proteins with fused biorecognition and catalytic units, were used to mimic multi-input Boolean logic systems. The catalytic parts of the systems were represented by pyrroloquinoline quinone-dependent glucose dehydrogenase (PQQ-GDH). Two biorecognition units, calmodulin or artificial peptide-clamp, were integrated into PQQ-GDH and locked it in the OFF or ON state respectively. The ligand-peptide binding cooperatively with Ca2+ cations to a calmodulin bioreceptor resulted in the enzyme activation, while another ligand-peptide bound to a clamp-receptor inhibited the enzyme. The enzyme activation and inhibition originated from peptide-induced allosteric transitions in the receptor units that propagated to the catalytic domain. While most of enzymes used to mimic Boolean logic gates operate with two inputs (substrate and co-substrate), the used chimeric enzymes were controlled by four inputs (glucose - substrate, dichlorophenolindophenol - electron acceptor/co-substrate, Ca2+ cations and a peptide - activating/inhibiting signals). The biocatalytic reactions controlled by four input signals were considered as logic networks composed of several concatenated logic gates. The developed approach allows potentially programming complex logic networks operating with various biomolecular inputs representing potential utility for different biomedical applications.


Asunto(s)
Calmodulina/farmacología , Biología Computacional , Glucosa Deshidrogenasas/antagonistas & inhibidores , Péptidos/farmacología , Biocatálisis , Calmodulina/química , Glucosa Deshidrogenasas/química , Glucosa Deshidrogenasas/metabolismo , Ligandos , Lógica , Modelos Moleculares , Estructura Molecular , Péptidos/química
9.
Sensors (Basel) ; 20(22)2020 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-33233539

RESUMEN

Biosensors are analytical devices that are able to convert a biological response into an electrical signal [...].


Asunto(s)
Técnicas Biosensibles , Anticuerpos , Enzimas , Ácidos Nucleicos
10.
Sensors (Basel) ; 20(12)2020 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-32575916

RESUMEN

This review summarizes the fundamentals of the phenomenon of electron transfer (ET) reactions occurring in redox enzymes that were widely employed for the development of electroanalytical devices, like biosensors, and enzymatic fuel cells (EFCs). A brief introduction on the ET observed in proteins/enzymes and its paradigms (e.g., classification of ET mechanisms, maximal distance at which is observed direct electron transfer, etc.) are given. Moreover, the theoretical aspects related to direct electron transfer (DET) are resumed as a guideline for newcomers to the field. Snapshots on the ET theory formulated by Rudolph A. Marcus and on the mathematical model used to calculate the ET rate constant formulated by Laviron are provided. Particular attention is devoted to the case of glucose oxidase (GOx) that has been erroneously classified as an enzyme able to transfer electrons directly. Thereafter, all tools available to investigate ET issues are reported addressing the discussions toward the development of new methodology to tackle ET issues. In conclusion, the trends toward upcoming practical applications are suggested as well as some directions in fundamental studies of bioelectrochemistry.


Asunto(s)
Técnicas Biosensibles , Transporte de Electrón , Electrones , Enzimas Inmovilizadas/química , Electrodos , Glucosa Oxidasa/química
11.
BMC Biotechnol ; 19(1): 61, 2019 08 19.
Artículo en Inglés | MEDLINE | ID: mdl-31426777

RESUMEN

BACKGROUND: Laccases are multicopper oxidases, which are assigned into auxiliary activity family 1 (AA1) in the CAZy database. These enzymes, catalyzing the oxidation of phenolic and nonphenolic substrates coupled to reduction of O2 to H2O, are increasingly attractive as eco-friendly oxidation biocatalysts. Basidiomycota laccases are well characterized due to their potential in de-lignification of lignocellulose. By contrast, insight into the biochemical diversity of Ascomycota counterparts from saprophytes and plant pathogens is scarce. RESULTS: Here, we report the properties of the laccase from the major wheat pathogen Zymoseptoria tritici (ZtrLac1A), distinguished from common plant fungal pathogens by an apoplastic infection strategy. We demonstrate that ZtrLac1A is appended to a functional starch-binding module and displays an activity signature disfavoring relatively apolar phenolic redox mediators as compared to the related biochemically characterized laccases. By contrast, the redox potential of ZtrLac1A (370 mV vs. SHE) is similar to ascomycetes counterparts. The atypical specificity is consistent with distinctive sequence substitutions and insertions in loops flanking the T1 site and the enzyme C-terminus compared to characterized laccases. CONCLUSIONS: ZtrLac1A is the first reported modular laccase appended to a functional starch-specific carbohydrate binding module of family 20 (CBM20). The distinct specificity profile of ZtrLac1A correlates to structural differences in the active site region compared to previously described ascomycetes homologues. These differences are also highlighted by the clustering of the sequence of ZtrLac1A in a distinct clade populated predominantly by plant pathogens in the phylogenetic tree of AA1 laccases. The possible role of these laccases in vivo merits further investigations. These findings expand our toolbox of laccases for green oxidation and highlight the binding functionality of CBM-appended laccases as versatile immobilization tags.


Asunto(s)
Ascomicetos/enzimología , Lacasa/química , Lacasa/metabolismo , Triticum/enzimología , Proteínas Fúngicas/química , Proteínas Fúngicas/metabolismo , Oxidación-Reducción , Estructura Secundaria de Proteína
12.
Chemphyschem ; 20(16): 2082-2092, 2019 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-31233266

RESUMEN

The studied enzyme-based biocatalytic system mimics NXOR Boolean logic gate, which is a logical operator that corresponds to equality in Boolean algebra. It gives the functional value true (1) if both functional arguments (input signals) have the same logical value (0,0 or 1,1), and false (0) if they are different (0,1 or 1,0). The output signal producing reaction is catalyzed by pyrroloquinoline quinone-dependent glucose dehydrogenase (PQQ-GDH), which is inhibited at acidic and basic pH values. Two other reactions catalyzed by esterase and urease produce acetic acid and ammonium hydroxide, respectively, shifting solution pH from the optimum pH for PQQ-GDH to acidic and basic values (1,0 and 0,1 input combinations, respectively), thus switching the enzyme activity off (output 0). When the input signals are not applied (0,0 combination) or both applied compensating each other (1,1 combination) the optimum pH is preserved, thus keeping PQQ-GDH running at the high rate (output 1). The biocatalytic cascade mimicking the NXOR gate was characterized optically and electrochemically. In the electrochemical experiments the PQQ-GDH enzyme communicated electronically with a conducting electrode support, thus resulting in the electrocatalytic current when signal combinations 0,0 and 1,1 were applied. The logic gate operation, when it was realized electrochemically, was also extended to the biomolecular release controlled by the gate. The release system included two electrodes, one performing the NXOR gate and another one activated for the release upon electrochemically stimulated alginate hydrogel dissolution. The studied system represents a general approach to the biocatalytic realization of the NXOR logic gate, which can be included in different catalytic cascades mimicking operation of concatenated gates in sophisticated logic circuitries.


Asunto(s)
Computadores Moleculares , Esterasas/química , Glucosa Deshidrogenasas/química , Lógica , Ureasa/química , Acetatos/química , Alginatos/química , Animales , Canavalia/enzimología , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Electrodos , Fluoresceína-5-Isotiocianato/química , Colorantes Fluorescentes/química , Concentración de Iones de Hidrógeno , Hierro/química , Nanotubos de Carbono/química , Porcinos , Urea/química
13.
Anal Bioanal Chem ; 411(29): 7645-7657, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31286179

RESUMEN

Graphite electrodes were modified with triangular (AuNTrs) or spherical (AuNPs) nanoparticles and further modified with fructose dehydrogenase (FDH). The present study reports the effect of the shape of these nanoparticles (NPs) on the catalytic current of immobilized FDH pointing out the different contributions on the mass transfer-limited and kinetically limited currents. The influence of the shape of the NPs on the mass transfer-limited and the kinetically limited current has been proved by using two different methods: a rotating disk electrode (RDE) and an electrode mounted in a wall jet flow-through electrochemical cell attached to a flow system. The advantages of using the wall jet flow system compared with the RDE system for kinetic investigations are as follows: no need to account for substrate consumption, especially in the case of desorption of enzyme, and studies of product-inhibited enzymes. The comparison reveals that virtually identical results can be obtained using either of the two techniques. The heterogeneous electron transfer (ET) rate constants (kS) were found to be 3.8 ± 0.3 s-1 and 0.9 ± 0.1 s-1, for triangular and spherical NPs, respectively. The improvement observed for the electrode modified with AuNTrs suggests a more effective enzyme-NP interaction, which can allocate a higher number of enzyme molecules on the electrode surface. Graphical abstract The shape of gold nanoparticles has a crucial effect on the catalytic current related to the oxidation of D-(-)-fructose to 5-keto-D-(-)-fructose occurring at the FDH-modified electrode surface. In particular, AuNTrs have a higher effect compared with the spherical one.


Asunto(s)
Deshidrogenasas de Carbohidratos/metabolismo , Fructosa/metabolismo , Oro/química , Nanopartículas del Metal/química , Catálisis , Electrodos , Cinética , Microscopía Electrónica de Transmisión , Espectrofotometría Ultravioleta , Espectroscopía Infrarroja Corta
14.
Anal Chem ; 90(20): 12131-12136, 2018 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-30148350

RESUMEN

In this paper we present a new method to electrodeposit highly porous gold (h-PG) onto a polycrystalline solid gold electrode without any template. The electrodeposition is carried out by first cycling the electrode potential between +0.8 and 0 V in 10 mM HAuCl4 with 2.5 M NH4Cl and then applying a negative potential for the production of hydrogen bubbles at the electrode surface. After that the modified electrode was characterized in sulfuric acid to estimate the real surface area ( Areal) to be close to 24 cm2, which is roughly 300 times higher compared to the bare gold electrodes (0.08 cm2). The electrode was further incubated overnight with three different thiols (4-mercaptobenzoic acid (4-MBA), 4-mercaptophenol (4-MPh), and 4-aminothiophenol (4-APh)) in order to produce differently charged self-assembled monolayers (SAMs) on the electrode surface. Finally a fructose dehydrogenase (FDH) solution was drop-cast onto the electrodes. All the modified electrodes were investigated by cyclic voltammetry both under nonturnover and turnover conditions. The FDH/4-MPh/h-PG exhibited two couples of redox peaks for the heme c1 and heme c2 of the cytochrome domain of FDH and as well as a well pronounced catalytic current density (about 1000 µA cm-2 in the presence of 10 mM fructose) due to the presence of -OH groups on the electrode surface, which stabilize and orientate the enzyme layer on the electrode surface. The FDH/4-MPh/h-PG based electrode showed the best analytical performance with an excellent stability (90% retained activity over 90 days), a detection limit of 0.3 µM fructose, a linear range between 0.05 and 5 mM, and a sensitivity of 175 ± 15 µA cm-2 mM-1. These properties were favorably compared with other fructose biosensors reported in the literature. The biosensor was successively tested to quantify the fructose content in food and beverage samples. No significant interference present in the sample matrixes was observed.


Asunto(s)
Técnicas Biosensibles , Deshidrogenasas de Carbohidratos/metabolismo , Enzimas Inmovilizadas/metabolismo , Análisis de los Alimentos , Fructosa/análisis , Compuestos de Sulfhidrilo/metabolismo , Deshidrogenasas de Carbohidratos/química , Electrodos , Enzimas Inmovilizadas/química , Fructosa/metabolismo , Oro/química , Oro/metabolismo , Tamaño de la Partícula , Porosidad , Compuestos de Sulfhidrilo/química , Propiedades de Superficie
15.
Biomacromolecules ; 19(9): 3883-3893, 2018 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-30088918

RESUMEN

Microcapsules and nanocapsules based on the contemporary presence of sulfonate lignin and tannic acid have been prepared by the layer-by-layer procedure, using MnCO3 or organosolv lignin as core templates, and polydiallyldimethylammonium chloride or chitosan as positive charged supporting layers. Nanocapsules and microcapsules of mixed polyphenols showed antioxidant activity, UV-shielding properties, and electrochemical responsiveness, higher than that in homopolymer nanocapsule counterparts and of the native polyphenols, suggesting the presence of synergistic effects between the two components. The presence of UV-visible bathochromic shift suggested the formation of J-aggregates characterized by an orientation of the adjacent phenolic rings parallel to the longitudinal direction of the layer, with a head-to-tail like arrangement. Moreover, nanocapsules of mixed polyphenols showed an aggregation state higher than that observed in references, the specific morphology of their surface being dependent on the structural arrangement of the different components.


Asunto(s)
Antioxidantes/administración & dosificación , Cápsulas/química , Nanocápsulas/química , Protectores contra Radiación/administración & dosificación , Cápsulas/síntesis química , Radicales Libres/química , Lignina/química , Polifenoles/química , Taninos/química , Rayos Ultravioleta
16.
Anal Bioanal Chem ; 410(14): 3253-3264, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29564502

RESUMEN

We report on the influence of pH and monovalent/divalent cations on the catalytic current response, internal electron transfer (IET), and structure of fructose dehydrogenase (FDH) by using amperometry, spectrophotometry, and circular dichroism (CD). Amperometric measurements were performed on graphite electrodes, onto which FDH was adsorbed and the effect on the response current to fructose was investigated when varying the pH and the concentrations of divalent/monovalent cations in the contacting buffer. In the presence of 10 mM CaCl2, a current increase of up to ≈ 240% was observed, probably due to an intra-complexation reaction between Ca2+ and the aspartate/glutamate residues found at the interface between the dehydrogenase domain and the cytochrome domain of FDH. Contrary to CaCl2, addition of MgCl2 did not show any particular influence, whereas addition of monovalent cations (Na+ or K+) led to a slight linear increase in the maximum response current. To complement the amperometric investigations, spectrophotometric assays were carried out under homogeneous conditions in the presence of a 1-electron non-proton-acceptor, cytochrome c, or a 2-electron-proton acceptor, 2,6-dichloroindophenol (DCIP), respectively. In the case of cytochrome c, it was possible to observe a remarkable increase in the absorbance up to 200% when 10 mM CaCl2 was added. However, by further increasing the concentration of CaCl2 up to 50 mM and 100 mM, a decrease in the absorbance with a slight inhibition effect was observed for the highest CaCl2 concentration. Addition of MgCl2 or of the monovalent cations shows, surprisingly, no effect on the electron transfer to the electron acceptor. Contrary to the case of cytochrome c, with DCIP none of the cations tested seem to affect the rate of catalysis. In order to correlate the results obtained by amperometric and spectrophotometric measurements, CD experiments have been performed showing a great structural change of FDH when increasing the concentration CaCl2 up to 50 mM, at which the enzyme molecules start to agglomerate, hindering the substrate access to the active site probably due to a chelation reaction occurring at the enzyme surface with the glutamate/aspartate residues. Graphical Abstract Fructose dehydrogenase (FDH) consists of three subunits, but only two are involved in the electron transfer process: (I) 2e-/2H+ fructose oxidation, (II) internal electron transfer (IET), (III) direct electron transfer (DET) through 2 heme c; FDH activity either in solution or when immobilized onto an electrode surface is enhanced about 2.5-fold by adding 10 mM CaCl2 to the buffer solution, whereas MgCl2 had an "inhibition" effect. Moreover, the additions of KCl or NaCl led to a slight current increase.


Asunto(s)
Deshidrogenasas de Carbohidratos/metabolismo , Fructosa/metabolismo , Gluconobacter/enzimología , Deshidrogenasas de Carbohidratos/química , Cationes/metabolismo , Transporte de Electrón , Gluconobacter/química , Gluconobacter/metabolismo , Concentración de Iones de Hidrógeno , Modelos Moleculares , Conformación Proteica
17.
Sensors (Basel) ; 18(5)2018 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-29695133

RESUMEN

Dehydrogenase based bioelectrocatalysis has been increasingly exploited in recent years in order to develop new bioelectrochemical devices, such as biosensors and biofuel cells, with improved performances. In some cases, dehydrogeases are able to directly exchange electrons with an appropriately designed electrode surface, without the need for an added redox mediator, allowing bioelectrocatalysis based on a direct electron transfer process. In this review we briefly describe the electron transfer mechanism of dehydrogenase enzymes and some of the characteristics required for bioelectrocatalysis reactions via a direct electron transfer mechanism. Special attention is given to cellobiose dehydrogenase and fructose dehydrogenase, which showed efficient direct electron transfer reactions. An overview of the most recent biosensors and biofuel cells based on the two dehydrogenases will be presented. The various strategies to prepare modified electrodes in order to improve the electron transfer properties of the device will be carefully investigated and all analytical parameters will be presented, discussed and compared.


Asunto(s)
Electrones , Fuentes de Energía Bioeléctrica , Técnicas Biosensibles , Electrodos , Transporte de Electrón , Oxidorreductasas
18.
Sensors (Basel) ; 17(8)2017 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-28820469

RESUMEN

Efficient direct electron transfer (DET) between a cellobiose dehydrogenase mutant from Corynascus thermophilus (CtCDH C291Y) and a novel glassy carbon (GC)-modified electrode, obtained by direct electrodeposition of gold nanoparticles (AuNPs) was realized. The electrode was further modified with a mixed self-assembled monolayer of 4-aminothiophenol (4-APh) and 4-mercaptobenzoic acid (4-MBA), by using glutaraldehyde (GA) as cross-linking agent. The CtCDH C291Y/GA/4-APh,4-MBA/AuNPs/GC platform showed an apparent heterogeneous electron transfer rate constant (ks) of 19.4 ± 0.6 s-1, with an enhanced theoretical and real enzyme surface coverage (Γtheor and Γreal) of 5287 ± 152 pmol cm-2 and 27 ± 2 pmol cm-2, respectively. The modified electrode was successively used as glucose biosensor exhibiting a detection limit of 6.2 µM, an extended linear range from 0.02 to 30 mM, a sensitivity of 3.1 ± 0.1 µA mM-1 cm-2 (R2 = 0.995), excellent stability and good selectivity. These performances compared favourably with other glucose biosensors reported in the literature. Finally, the biosensor was tested to quantify the glucose content in human saliva samples with successful results in terms of both recovery and correlation with glucose blood levels, allowing further considerations on the development of non-invasive glucose monitoring devices.


Asunto(s)
Técnicas Biosensibles , Carbono , Celobiosa , Electrodos , Enzimas Inmovilizadas , Glucosa , Glucosa Oxidasa , Oro , Nanopartículas del Metal , Saliva
19.
Anal Bioanal Chem ; 408(12): 3203-11, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26874693

RESUMEN

In this work, several theoretical aspects involved in the first-generation inhibition-based electrochemical biosensor measurements have been discussed. In particular, we have developed a theoretical-methodological approach for the characterization of the kinetic interaction between alkaline phosphatase (AlP) and 2,4-dichlorophenoxy acetic acid (2,4-D) as representative inhibitor studied by means of cyclic voltammetry and amperometry. Based on these findings, a biosensor for the fast, simple, and inexpensive determination of 2,4-D has been developed. The enzyme has been immobilized on screen-printed electrodes (SPEs). To optimize the biosensor performances, several carbon-based SPEs, namely graphite (G), graphene (GP), and multiwalled carbon nanotubes (MWCNTs), have been evaluated. AlP was immobilized on the electrode surface by means of polyvinyl alcohol with styryl-pyridinium groups (PVA-SbQ) as cross-linking agent. In the presence of ascorbate 2-phosphate (A2P) as substrate, the herbicide has been determined, thanks to its inhibition activity towards the enzyme catalyzing the oxidation of A2P to ascorbic acid (AA). Under optimum experimental conditions, the best performance in terms of catalytic efficiency has been demonstrated by MWCNTs SPE-based biosensor. The inhibition biosensor shows a linearity range towards 2,4-D within 2.1-110 ppb, a LOD of 1 ppb, and acceptable repeatability and stability. This analysis method was applied to fortified lake water samples with recoveries above 90%. The low cost of this device and its good analytical performances suggest its application for the screening and monitoring of 2,4-D in real matrices.


Asunto(s)
Ácido 2,4-Diclorofenoxiacético/análisis , Técnicas Biosensibles , Técnicas Electroquímicas/métodos , Cinética
20.
Nanoscale Adv ; 6(2): 516-523, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38235094

RESUMEN

Herein, we describe a novel method for producing cadmium-selenide nanoparticles (CdSe NPs) with controlled size using apoferritin as a bionanoreactor triggered by local pH change at the electrode/solution interface. Apoferritin is known for its reversible self-assembly at alkaline pH. The pH change is induced electrochemically by reducing O2 through the application of sufficiently negative voltages and bioelectrochemically through O2 reduction catalyzed by laccase, co-immobilized with apoferritin on the electrode surface. Specifically, a Ti electrode is modified with (3-aminopropyl)triethoxysilane, followed by glutaraldehyde cross-linking (1.5% v/v in H2O) of apoferritin (as the bionanoreactor) and laccase (as the local pH change triggering system). This proposed platform offers a universal approach for controlling the synthesis of semiconductor NPs within a bionanoreactor solely driven by (bio)electrochemical inputs. The CdSe NPs obtained through different synthetic approaches, namely electrochemical and bioelectrochemical, were characterized spectroscopically (UV-Vis, Raman, XRD) and morphologically (TEM). Finally, we conducted online monitoring of CdSe NPs formation within the apoferritin core by integrating the electrochemical system with LWs. The quantity of CdSe NPs produced through bioelectrochemical means was determined to be 2.08 ± 0.12 mg after 90 minutes of voltage application in the presence of O2. TEM measurements revealed that the bioelectrochemically synthesized CdSe NPs have a diameter of 4 ± 1 nm, accounting for 85% of the size distribution, a result corroborated by XRD data. Further research is needed to explore the synthesis of nanoparticles using different biological nanoreactors, as the process can be challenging due to the elevated buffer capacitance of biological media.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA