Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Cardiovasc Ultrasound ; 19(1): 23, 2021 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-34147117

RESUMEN

BACKGROUND: In patients with repaired Fallot, subsequent surgical or interventional procedures and adverse cardiac events are frequent. We aimed to evaluate the impact of a simple pre-operative anatomic classification based on the size of the pulmonary valve (PV) annulus and branches on future therapeutic requirements and outcomes. METHOD: This is a single-center retrospective analysis of patients operated for Fallot before the age of 2 years, from January 1990. Pre-operative anatomy, surgical and interventional procedures and adverse events were extrapolated from clinical records. RESULTS: Among the 312 patients, a description of the PV and pulmonary arteries (PAs) native anatomy was known in 239 patients (male:147, 61.5%), which were divided in the following 3 groups: group 1 (65 patients) with normal size of both PV and PAs; group 2 (108 patients) with PV hypoplasia but normal size PAs; group 3 (66 patients) with concomitant hypoplasia of the PV and PAs. During the 12.7 years (IQR 6.7-17) follow-up time, 23% of patients required at least one surgical or interventional procedure. At Kaplan-Meier analysis, there was a significant difference in requirement of future surgical or interventional procedures among the 3 groups (p < 0,001). At multivariate Cox regression analysis, hypoplasia of PV and PAs was an independent predictor of subsequent procedures (HR:3.1,CI:1.06-9.1, p = 0.03). CONCLUSION: Native anatomy in Tetralogy of Fallot patients affects surgical strategy and follow-up. It would be therefore advisable to tailor patient's counseling and follow-up according to native anatomy, rather than following a standardized protocol.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Tetralogía de Fallot , Preescolar , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Tetralogía de Fallot/cirugía , Resultado del Tratamiento
2.
J Cardiovasc Med (Hagerstown) ; 25(7): 473-487, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38829936

RESUMEN

Cardiovascular magnetic resonance (CMR) and computed tomography (CCT) are advanced imaging modalities that recently revolutionized the conventional diagnostic approach to congenital heart diseases (CHD), supporting echocardiography and often replacing cardiac catheterization. This is the second of two complementary documents, endorsed by experts from the Working Group of the Italian Society of Pediatric Cardiology and the Italian College of Cardiac Radiology of the Italian Society of Medical and Interventional Radiology, aimed at giving updated indications on the appropriate use of CMR and CCT in different clinical CHD settings, in both pediatrics and adults. In this article, support is also given to radiologists, pediatricians, cardiologists, and cardiac surgeons for indications and appropriateness criteria for CMR and CCT in the most referred CHD, following the proposed new criteria presented and discussed in the first document. This second document also examines the impact of devices and prostheses for CMR and CCT in CHD and additionally presents some indications for CMR and CCT exams when sedation or narcosis is needed.


Asunto(s)
Consenso , Cardiopatías Congénitas , Humanos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/terapia , Italia , Tomografía Computarizada por Rayos X/normas , Cardiología/normas , Imagen por Resonancia Magnética/normas , Niño , Valor Predictivo de las Pruebas , Adulto , Sociedades Médicas/normas
3.
Eur Heart J ; 33(19): 2434-41, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22798559

RESUMEN

AIMS: To assess the impact of relief of pulmonary stenosis (PS) and pulmonary regurgitation (PR) by percutaneous pulmonary valve implantation (PPVI) on biventricular function during exercise stress. METHODS AND RESULTS: Seventeen patients, who underwent PPVI for PS or PR, were included. Magnetic resonance imaging was performed at rest and during supine exercise stress pre- and within 1-month post-PPVI, using a radial k - t SENSE real-time sequence. In patients with PS (n = 9), there was no reserve in right ventricular (RV) ejection fraction (EF) in response to exercise prior to PPVI (48.2 ± 12.1% at rest vs. 48.4 ± 14.8% during exercise, P = 0.87). Post-PPVI, reserve in RVEF in response to exercise was re-established (53.4 ± 15.0% at rest vs. 59.6 ± 17.3% during exercise, P = 0.003) with improvement in left ventricular stroke volume (LVSV) (45.4 ± 6.2 mL/m(2) at rest vs. 52.8 ± 8.8 mL/m(2) during exercise, P = 0.001). In patients with PR prior to PPVI (n = 8), LVSV during exercise increased (43.0 ± 8.5 vs. 54.3 ± 6.6 mL/m(2), P < 0.001) due to reduction in PR fraction during exercise (29.2 ± 5.2 vs. 13.6 ± 6.1%, P < 0.001). After PPVI, LVSV increased from rest to exercise (48.4 ± 8.8 vs. 57.2 ± 8.1 mL/m(2), P < 0.001) due to improved RVEF (45.5 ± 8.3 vs. 50.4 ± 6.9%, P = 0.001). There was a significantly higher increase in LVSV at exercise from pre- to post-PPVI in PS patients than in PR patients (ΔLVSV 8.2 ± 4.1 vs. Δ2.9 ± 4.1 mL/m(2), P = 0.01). The reduction in the RV outflow tract gradient correlated significantly with the improvement in LVSV during exercise (r = -0.73, P < 0.001). CONCLUSION: Percutaneous pulmonary valve implantation in patients with PS leads to restoration of reserve in RVEF during exercise stress. In patients with PR, SV augmentation improves only mildly post-PPVI. Improvement in SV augmentation during exercise stress after PPVI is dependent mainly on afterload reduction.


Asunto(s)
Cateterismo Cardíaco/métodos , Ejercicio Físico/fisiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Pulmonar/cirugía , Estenosis de la Válvula Pulmonar/cirugía , Adolescente , Adulto , Técnicas de Imagen Sincronizada Cardíacas/métodos , Niño , Prueba de Esfuerzo , Femenino , Humanos , Angiografía por Resonancia Magnética/métodos , Masculino , Estudios Prospectivos , Válvula Pulmonar/fisiología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Estenosis de la Válvula Pulmonar/fisiopatología , Volumen Sistólico/fisiología , Función Ventricular Derecha/fisiología , Adulto Joven
4.
Eur Radiol ; 21(1): 36-45, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20680286

RESUMEN

OBJECTIVE: To characterise 3D deformations of the right ventricular outflow tract (RVOT)/pulmonary arteries (PAs) during the cardiac cycle and estimate the errors of conventional 2D assessments. METHODS: Contrast-enhanced, ECG-gated cardiovascular computed tomography (CT) findings were retrospectively analysed from 12 patients. The acquisition of 3D images over 10 phases of the cardiac cycle created a four-dimensional CT (4DCT) dataset. The datasets were reconstructed and deformation measured at various levels of the RVOT/PAs in both space and time. Section planes were either static or dynamic relative to the motion of the structures. RESULTS: 4DCT enabled measurement and characterisation of in vivo 3D changes of patients' RVOT/PA during the cardiac cycle. The studied patient population showed a wide range of RVOT/PA morphologies, sizes and dynamics that develop late after surgical repair of congenital heart disease. There were also significant differences in the measured cross-sectional areas of the structures between static and dynamic section planes (up to 150%, p<0.05) secondary to large 3D displacements and rotations. CONCLUSIONS: 4DCT imaging data suggest high variability in RVOT/PA dynamics and significant errors in deformation measurements if 3D analysis is not carried out. These findings play an important role for the development of novel percutaneous approaches to pulmonary valve intervention.


Asunto(s)
Tomografía Computarizada Cuatridimensional , Arteria Pulmonar , Obstrucción del Flujo Ventricular Externo/diagnóstico , Adulto , Anciano , Niño , Preescolar , Medios de Contraste , Femenino , Tomografía Computarizada Cuatridimensional/métodos , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Arteria Pulmonar/anomalías , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Adulto Joven
5.
Circulation ; 119(23): 2995-3001, 2009 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-19487596

RESUMEN

BACKGROUND: Treatment of right ventricular outflow tract obstruction is possible with a bare metal stent (BMS), although this treatment causes pulmonary regurgitation. In this study, we assessed the acute physiological effects of BMS versus percutaneous pulmonary valve implantation (PPVI) using an x-ray/magnetic resonance hybrid laboratory. METHODS AND RESULTS: Fourteen consecutive children (median age, 12.9 years) with significant right ventricular outflow tract obstruction underwent BMS followed by PPVI. Magnetic resonance imaging (ventricular volumes and function and great vessel blood flow) and hemodynamic assessment (invasive pressure measurements) were performed before BMS, after BMS, and after PPVI; all were performed under general anesthesia in an x-ray/magnetic resonance hybrid laboratory. BMS significantly reduced the ratio of right ventricular to systemic pressure (0.75+/-0.17% versus 0.41+/-0.14%; P<0.001) with no further change after PPVI (0.42+/-0.11; P=1.0). However, BMS resulted in free pulmonary regurgitation (21.3+/-10.7% versus 41.4+/-7.5%; P<0.001), which was nearly abolished after PPVI (3.6+/-5.6%; P<0.001). Effective right ventricular stroke volume (right ventricular stroke volume minus pulmonary regurgitant volume) after BMS remained unchanged (33.8+/-7.3 versus 32.6+/-8.7 mL/m2; P=1.0) but was significantly increased after revalvulation with PPVI (41.0+/-8.0 mL/m2; P=0.004). These improvements after PPVI were accompanied by a significant heart rate reduction (75.5+/-17.7 bpm after BMS versus 69.0+/-16.9 bpm after PPVI; P=0.006) at maintained cardiac output (2.5+/-0.5 versus 2.4+/-0.5 versus 2.7+/-0.5 mL x min(-1) x m(-2); P=0.14). CONCLUSIONS: Using an x-ray/magnetic resonance hybrid laboratory, we have demonstrated the superior acute hemodynamic effects of PPVI over BMS in patients with right ventricular outflow tract obstruction.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Stents , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Cateterismo Cardíaco , Volumen Cardíaco , Niño , Femenino , Fluoroscopía , Humanos , Imagen por Resonancia Magnética , Masculino , Metales , Estudios Prospectivos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/patología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/patología , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/patología , Disfunción Ventricular Derecha/cirugía , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/patología , Presión Ventricular
6.
Eur Heart J ; 30(18): 2266-74, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19561027

RESUMEN

AIMS: To investigate the impact of relief of right ventricle (RV) to pulmonary artery (PA) conduit obstruction on septal motion and ventricular interaction and its functional implications for left ventricular (LV) filling properties. METHODS AND RESULTS: In 20 consecutive patients with congenital heart disease and RV to PA conduit obstruction, the following were prospectively assessed before and after percutaneous pulmonary valve implantation (PPVI): the septal curvature and LV volumes throughout the cardiac cycle by magnetic resonance imaging; RV to LV mechanical delay by 2D-echocardiographic strain imaging; and objective exercise capacity. Percutaneous pulmonary valve implantation led to a reduction in RV to LV mechanical delay (127.9 +/- 50.9 vs. 37.7 +/- 35.6 ms; P < 0.001) and less LV septal bowing in early LV diastole (septal curvature: -0.11 +/- 0.11 vs. 0.07 +/- 0.13 cm(-1); P < 0.001). Early LV diastolic filling (first one-third of diastole) increased significantly (17.5 +/- 9.4 to 30.4 +/- 9.4 mL/m(2); P < 0.001). The increase in early LV diastolic filling correlated with the reduction in RV to LV mechanical delay (r = -0.68; P = 0.001) and change in septal curvature (r = 0.71; P < 0.001). In addition, the improvement in peak oxygen uptake (56.0 +/- 16.0 vs. 64.1 +/- 13.7% of predicted; P < 0.001) was associated with the increase in early LV diastolic filling (r = 0.69; P = 0.001). CONCLUSION: Relief of RV to PA conduit obstruction significantly improves early LV filling properties. This is attributed to more favourable septal motion and reduction in interventricular mechanical delay.


Asunto(s)
Arritmias Cardíacas/etiología , Oclusión de Injerto Vascular/cirugía , Ventrículos Cardíacos/anomalías , Arteria Pulmonar/anomalías , Estenosis de la Válvula Pulmonar/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/fisiopatología , Presión Sanguínea/fisiología , Prótesis Vascular , Niño , Ecocardiografía , Femenino , Oclusión de Injerto Vascular/fisiopatología , Tabiques Cardíacos/fisiología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ventrículos Cardíacos/cirugía , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Arteria Pulmonar/cirugía , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Estenosis de la Válvula Pulmonar/fisiopatología , Estrés Mecánico , Adulto Joven
7.
Eur Heart J ; 30(17): 2147-54, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19502232

RESUMEN

AIMS: To prospectively evaluate homograft function with cardiac magnetic resonance (CMR) imaging 1 year after insertion into the pulmonary position, and to assess the impact of in situ homograft geometry, surgical factors, and 'intrinsic' homograft properties on early valve incompetence. METHODS AND RESULTS: A total of 60 patients (mean age 21 +/- 10 years; 35 females) with congenital heart disease underwent pulmonary valve replacement with homograft insertion and were prospectively enrolled into a study protocol that included serial echocardiography and CMR 1 year after surgery. None of the patients had homograft stenosis but 10 (17%) had significant homograft incompetence (i.e. pulmonary regurgitation fraction >20% on CMR). A higher incidence of 'eccentric' pulmonary forward flow pattern (P < 0.001, Fisher's exact test), more acute 'homograft distortion angle' (P < 0.001), larger relative 'annular' size (P < 0.01), and greater pre-homograft right ventricular outflow tract (RVOT) diameters (P = 0.01) at CMR was seen in those with worse homograft function. In a backward multivariate linear regression model, 'eccentric' pulmonary forward flow pattern (r(part) = 0.36, P < 0.001), 'homograft distortion angle' (r(part) = 0.31, P = 0.001), and pre-homograft RVOT diameter (r(part) = 0.19, P = 0.03) were independently associated with the degree of pulmonary regurgitation (in %) at 1 year. CONCLUSION: Using CMR, in this prospective cohort study, we have shown that significant valve incompetence is present in one-sixth of patients after homograft insertion into the pulmonary position, and that alterations in the in situ homograft geometry were associated with the likelihood of developing valve incompetence. These findings imply that mechanical factors may have an important impact on homograft performance.


Asunto(s)
Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Adulto , Ecocardiografía , Femenino , Supervivencia de Injerto , Cardiopatías Congénitas/patología , Cardiopatías Congénitas/fisiopatología , Humanos , Angiografía por Resonancia Magnética , Masculino , Estudios Prospectivos , Insuficiencia de la Válvula Pulmonar/patología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Volumen Sistólico/fisiología , Trasplante Homólogo , Resultado del Tratamiento , Adulto Joven
8.
Cardiol Young ; 20(1): 25-32, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20144254

RESUMEN

Atrial septostomy is performed in patients with severe pulmonary arterial hypertension, and has been shown to improve symptoms, quality of life and survival. Despite recognized clinical benefits, the underlying pathophysiologic mechanisms are poorly understood. We aimed to assess the effects of right-to-left shunting on arterial delivery of oxygen, mixed venous content of oxygen, and systemic cardiac output in patients with pulmonary arterial hypertension and a fixed flow of blood to the lungs. We formulated equations defining the mandatory relationship between physiologic variables and delivery of oxygen in patients with right-to-left shunting. Using calculus and computer modelling, we considered the simultaneous effects of right-to-left shunting on physiologies with different pulmonary flows, total metabolic rates, and capacities for carrying oxygen. Our study indicates that, when the flow of blood to the lungs is fixed, increasing right-to-left shunting improves systemic cardiac output, arterial blood pressure, and arterial delivery of oxygen. In contrast, the mixed venous content of oxygen, which mirrors the average state of tissue oxygenation, remains unchanged. Our model suggests that increasing the volume of right-to-left shunting cannot compensate for right ventricular failure. Atrial septostomy in the setting of pulmonary arterial hypertension, therefore, increases the arterial delivery of oxygen, but the mixed systemic saturation of oxygen, arguably the most important index of tissue oxygenation, stays constant. Our data suggest that the clinically observed beneficial effects of atrial septostomy are the result of improved flow of blood rather than augmented tissue oxygenation, provided that right ventricular function is adequate.


Asunto(s)
Tabique Interatrial/cirugía , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/cirugía , Modelos Cardiovasculares , Consumo de Oxígeno , Oxígeno/sangre , Circulación Pulmonar , Análisis de los Gases de la Sangre , Procedimientos Quirúrgicos Cardíacos/métodos , Simulación por Computador , Hemodinámica , Hemoglobinas/análisis , Humanos , Hipertensión Pulmonar/diagnóstico , Intercambio Gaseoso Pulmonar , Flujo Sanguíneo Regional , Sensibilidad y Especificidad
9.
Circulation ; 118(14 Suppl): S182-90, 2008 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-18824753

RESUMEN

BACKGROUND: The timing of pulmonary valve replacement (PVR) for free pulmonary incompetence in patients with congenital heart disease remains a dilemma for clinicians. We wanted to assess the determinants of improvement after PVR for pulmonary regurgitation over a wide range of patient ages and to use any identified predictors to compare clinical outcomes between patient groups. METHODS AND RESULTS: Seventy-one patients (mean age 22+/-11 years; range, 8.5 to 64.9; 72% tetralogy of Fallot) underwent PVR for severe pulmonary regurgitation. New York Heart Association class improved after PVR (median of 2 to 1, P<0.0001). MRI and cardiopulmonary exercise testing were performed before and 1 year after intervention. After PVR, there was a significant reduction in right ventricular volumes (end diastolic volume 142+/-43 to 91+/-18, end systolic volume 73+/-33 to 43+/-14 mL/m(2), P<0.0001), whereas left ventricular end diastolic volume increased (66+/-12 to 73+/-13 mL/m(2), P<0.0001). Effective cardiac output significantly increased (right ventricular: 3.0+/-0.8 to 3.3+/-0.8 L/min, P=0.013 and left ventricular: 3.0+/-0.6 to 3.4+/-0.7 L/min, P<0.0001). On cardiopulmonary exercise testing, ventilatory response to carbon dioxide production at anaerobic threshold improved from 35.9+/-5.8 to 34.1+/-6.2 (P=0.008). Normalization of ventilatory response to carbon dioxide production was most likely to occur when PVR was performed at an age younger than 17.5 years (P=0.013). CONCLUSIONS: A relatively aggressive PVR policy (end diastolic volume <150 mL/m(2)) leads to normalization of right ventricular volumes, improvement in biventricular function, and submaximal exercise capacity. Normalization of ventilatory response to carbon dioxide production is most likely to occur when surgery is performed at an age

Asunto(s)
Factores de Edad , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Función Ventricular , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Umbral Anaerobio , Dióxido de Carbono , Niño , Estudios de Cohortes , Ecocardiografía , Prueba de Esfuerzo , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Resistencia Física , Periodo Posoperatorio , Pronóstico , Estudios Prospectivos , Insuficiencia de la Válvula Pulmonar/diagnóstico , Insuficiencia de la Válvula Pulmonar/fisiopatología , Respiración , Volumen Sistólico , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/fisiopatología
10.
Circulation ; 117(15): 1964-72, 2008 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-18391109

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation was introduced in the year 2000 as a nonsurgical treatment for patients with right ventricular outflow tract dysfunction. METHODS AND RESULTS: Between September 2000 and February 2007, 155 patients with stenosis and/or regurgitation underwent percutaneous pulmonary valve implantation. This led to significant reduction in right ventricular systolic pressure (from 63+/-18 to 45+/-13 mm Hg, P<0.001) and right ventricular outflow tract gradient (from 37+/-20 to 17+/-10 mm Hg, P<0.001). Follow-up ranged from 0 to 83.7 months (median 28.4 months). Freedom from reoperation was 93% (+/-2%), 86% (+/-3%), 84% (+/-4%), and 70% (+/-13%) at 10, 30, 50, and 70 months, respectively. Freedom from transcatheter reintervention was 95% (+/-2%), 87% (+/-3%), 73% (+/-6%), and 73% (+/-6%) at 10, 30, 50, and 70 months, respectively. Survival at 83 months was 96.9%. On time-dependent analysis, the first series of 50 patients (log-rank test P<0.001) and patients with a residual gradient >25 mm Hg (log-rank test P=0.01) were associated with a higher risk of reoperations. CONCLUSIONS: Percutaneous pulmonary valve implantation resulted in the ability to avoid surgical right ventricular outflow tract revision in the majority of cases. This procedure might reduce the number of operations needed over the total lifetime of patients with right ventricle-to-pulmonary artery conduits.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Válvula Pulmonar/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Adulto , Anciano , Cateterismo Cardíaco , Niño , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Aprendizaje , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/estadística & datos numéricos , Procedimientos Quirúrgicos Mínimamente Invasivos/tendencias , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología , Reoperación , Estudios Retrospectivos , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/cirugía , Resultado del Tratamiento , Ultrasonografía , Obstrucción del Flujo Ventricular Externo/etiología
11.
J Heart Valve Dis ; 18(1): 28-34, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19301550

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Percutaneous mitral valve (MV) dilatation is routinely performed for mitral stenosis using either a single balloon (SB) or double balloon (DB) technique. The study aim was to compare the two techniques using the finite element (FE) method. METHODS: An established FE model of the MV was modified by fusing MV leaflet edges at commissure level to simulate a stenotic valve (orifice area = 180 mm2). FE models of a 30 mm SB (low-pressure, elastomeric balloon) and an 18 mm DB system (high-pressure, non-elastic balloon) were created. RESULTS: Both, SB and DB simulations, resulted in the splitting of commissures and consequent relief of stenosis (final MV areas of 610 mm2 and 560 mm2, respectively). Stresses induced by the two balloon systems varied across the valve. At full inflation, SB showed a higher stress in the central part of the leaflets and at the commissures compared to DB simulation, which demonstrated a more uniform stress distribution. This was due to mismatch of the round shape of the SB within an oval mitral orifice. Due to its high compliance, commissural splitting was not easily accomplished with the SB. Conversely, the DB guaranteed commissural splitting, even when a high force was required to break the commissure welds. CONCLUSION: The FE model demonstrated that MV dilatation can be accomplished by both SB and DB techniques. However, the DB method resulted in a higher probability of splitting the fused commissures, with less potential for damage to the MV leaflets by overstretching, even at higher pressures.


Asunto(s)
Cateterismo/métodos , Estenosis de la Válvula Mitral/terapia , Fenómenos Biomecánicos , Cateterismo/instrumentación , Análisis de Elementos Finitos , Humanos , Técnicas In Vitro , Válvula Mitral/fisiología , Modelos Cardiovasculares
12.
Artif Organs ; 33(1): 46-53, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19178440

RESUMEN

Percutaneous pulmonary valve implantation is a potential treatment for right ventricular outflow tract (RVOT) dysfunction. However, RVOT implantation site varies among subjects and the success of the procedure depends on RVOT morphology selection. The aim of this study was to use in vitro testing to establish percutaneous valve competency in different previously defined RVOT morphologies. Five simplified RVOT geometries (stenotic, enlarged, straight, convergent, and divergent) were manufactured by silicone dipping. A mock bench was developed to test the percutaneous valve in the five different RVOTs. The bench consists of a volumetric pulsatile pump and of a hydraulic afterload. The pump is made of a piston driven by a low inertia programmable motor. The hydraulic afterload mimics the pulmonary input impedance and its design is based on a three element model of the pulmonary circulation. The mock bench can replicate different physiological and pathological hemodynamic conditions of the pulmonary circulation. The mock bench is here used to test the five RVOTs under physiological-like conditions: stroke volume range 40-70 mL, frequency range 60-80 bpm. The valved stent was implanted into the five different RVOT geometries. Pressures upstream and downstream of the valved stent were monitored. Flow rates were measured with and without the valved stent in the five mock RVOTs, and regurgitant fraction compared between the different valved stent RVOTs. The percutaneous valved stent drastically reduced regurgitant flow if compared with the RVOT without the valve. RVOT geometry did not significantly influence the flow rate curves. Mean regurgitant fractions varied from 5% in the stenotic RVOT to 7.3% in the straight RVOT, highlighting the influence of the RVOT geometry on valve competency. The mock bench presented in this study showed the ability to investigate the influence of RVOT geometry on the competence of valved stent used for percutaneous pulmonary valve treatment.


Asunto(s)
Prótesis Valvulares Cardíacas , Implantación de Prótesis , Válvula Pulmonar , Stents , Obstrucción del Flujo Ventricular Externo/terapia , Hemodinámica , Humanos , Modelos Cardiovasculares , Silicio
13.
Artículo en Inglés | MEDLINE | ID: mdl-19349024

RESUMEN

Percutaneous pulmonary valve implantation is a new treatment option in patients with dysfunctional conduits. The aim of percutaneous pulmonary valve implantation is to prolong the lifespan of right ventricle to pulmonary artery conduits and thereby postponing open-heart surgery. Early results have shown a significant reduction in right ventricular pressure and right ventricular outflow tract gradient. During a follow-up of a median of 28 months, freedom from re-operation is 93 (2), 86 (3), 84 (4), and 70 (13)% at 10, 30, 50, and 70 months, respectively. The most common complication during follow-up are stent fractures with an incidence around 20%. Although clinically silent in the majority of cases, stent fractures led to re-intervention in the form of implantation of a second device (valve-in-valve). Valvar function during follow-up was well maintained. Significant pulmonary regurgitation was only seen in the context of endocarditis. Pulmonary valve implantation has the potential to become the standard procedure in the treatment of dysfunctional conduits. Bigger challenges will now have to be met in order to extend this technology to patients with native outflow tracts and free pulmonary regurgitation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/anomalías , Válvula Pulmonar/cirugía , Cateterismo Cardíaco , Cateterismo/métodos , Hemodinámica , Humanos , Lactante , Recién Nacido , Procedimientos Quirúrgicos Mínimamente Invasivos , Complicaciones Posoperatorias , Stents , Obstrucción del Flujo Ventricular Externo/cirugía
15.
Trends Cardiovasc Med ; 18(4): 117-25, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18555184

RESUMEN

Valvular heart disease continues to be an important health care problem. Although surgical valve replacement remains the standard treatment, minimally invasive approaches for valve repair and replacement are becoming attractive alternatives among physicians and patients. In fact, percutaneous procedures can extend treatment to the increasing population of elderly patients with severe comorbidities who cannot withstand the stress of open heart surgery and to the younger patients at the early stage of valve disease, who are not treated until older ages to avoid multiple invasive surgeries. Feasibility of this technique has been shown in the first clinical experiences, and the early results are promising. However, it is clear that percutaneous valve replacement therapy is still at the early stage of development and requires enhanced implantation procedures and substantial design improvements as well as long-term follow-up to show the safety and effectiveness of this new treatment modality.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Animales , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Diseño de Prótesis , Resultado del Tratamiento
16.
Int J Cardiol ; 283: 107-111, 2019 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-30819586

RESUMEN

BACKGROUND: While left atrial (LA) size has been shown as a strong predictor of cardiovascular diseases in various studies, the role of right atrial (RA) enlargement, especially in the growing population of patients with congenital heart diseases (CHD) is largely unknown. We sought to evaluate (1) RA and LA volumes in patients with repaired Tetralogy of Fallot (TOF) and assess correlations to (2) functional parameters and (3) clinical adverse events. METHODS: 169 patients with repaired TOF were enrolled following a targeted protocol for Cardiovascular magnetic resonance imaging (CMR), Cardiopulmonary exercise tests (CPET), Echocardiography and Measurement of NT-proBNP. Clinical history was assessed at enrollment and during a median Follow-up of 23 months (IQR 9-40). The primary clinical endpoint was a composite of all cause mortality, aborted sudden cardiac death and sustained VT. Prespecified secondary surrogate endpoint included worsening heart failure (NYHA III-IV), non-sustained VT and sustained supraventricular tachycardia. RESULTS: RA Systolic indexed volume (RASVi) correlated with LA Systolic indexed volume (LASVi) (r = 0.59, p < 0.001) and both correlated with the patient age (r = 0.52, p < 0.001; r = 0.59, p < 0.001 respectively). Patients in the upper tertil of RASVi (>58 ml/m2) had higher NT-proBNP levels, longer QRS duration, larger ventricle diameters, higher RV mass and lower peak oxygen uptake. RASVi was associated with the primary composite adverse event at univariate Cox-regression analysis (HR: 1.044, CI: 1.008-1.08, p = 0.01). Bayesian Multivariate model averaging revealed RASVi as predictor of secondary surrogate adverse outcome (HR: 1.06, CI: 1.053-1.068, Pb = 0,889). CONCLUSION: Among patients with repaired TOF, RA dilatation is an independent predictor for adverse clinical events. As such, routine assessment of RA volumes could be useful to further improve decision-making and management of these patients in the future.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Atrios Cardíacos/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Adolescente , Adulto , Anciano , Volumen Cardíaco , Causas de Muerte/tendencias , Niño , Progresión de la Enfermedad , Ecocardiografía , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Atrios Cardíacos/fisiopatología , Humanos , Italia/epidemiología , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Tetralogía de Fallot/diagnóstico , Tetralogía de Fallot/mortalidad , Adulto Joven
17.
Circulation ; 115(11): 1392-7, 2007 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-17339542

RESUMEN

BACKGROUND: We analyzed the incidence, risk factors and treatment options for stent fracture after percutaneous pulmonary valve (PPV) implantation (PPVI). METHODS AND RESULTS: After PPVI, 123 patients had chest x-ray in anteroposterior and lateral projection, echocardiography, and clinical evaluation during structured follow-up. Of these 123 patients, 26 (21.1%) developed stent fracture 0 to 843 days after PPVI (stent fracture-free survival at 1 year, 85.1%; at 2 years, 74.5%; and at 3 years, 69.2%). Stent fracture was classified as type I: no loss of stent integrity (n=17); type II: loss of integrity with restenosis on echocardiography (n=8); and type III: separation of fragments or embolization (n=1). In a multivariate Cox regression, we analyzed various factors, of which 3 were associated with a higher risk of stent fracture: implantation into "native" right ventricular outflow tract (P=0.04), no calcification along the right ventricular outflow tract (judged with fluoroscopy, P=0.02), recoil of PPV (qualitatively, PPV diameter in frontal or lateral plane with fully inflated balloon > diameter after balloon deflation, P=0.03). Substernal PPV location, high-pressure post-PPVI dilatation of PPV, pre-PPVI right ventricular outflow tract gradients, and other indicators of PPV compression or asymmetry did not pose increased risk. Patients with type I fracture remain under follow-up. Patients with type II fracture had 2nd PPVI or are awaiting such procedure, and 1 patient with type III fracture required surgical explantation. CONCLUSIONS: Stent fracture after PPVI can be managed effectively by risk stratification, systematic classification, and anticipatory management strategies. Serial x-ray and echocardiography are recommended for surveillance.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Falla de Prótesis , Insuficiencia de la Válvula Pulmonar/epidemiología , Insuficiencia de la Válvula Pulmonar/cirugía , Stents/efectos adversos , Adolescente , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/clasificación , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Modelos de Riesgos Proporcionales , Válvula Pulmonar/anomalías , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Factores de Riesgo , Stents/estadística & datos numéricos , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/epidemiología , Disfunción Ventricular Derecha/cirugía
18.
Eur J Cardiothorac Surg ; 33(4): 607-12, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18255307

RESUMEN

OBJECTIVE: Percutaneous pulmonary valve insertion (PPVI) is an evolving alternative to surgical pulmonary valve insertion. The aim of this study is to review the acute complications of PPVI requiring emergency rescue surgery. PATIENTS AND METHODS: Between 09/2000 and 01/2007, 152 patients (pts), received a PPVI. Patient's charts were reviewed in retrospect. RESULTS: Emergency rescue surgery (ERS) took place in 6 pts (3.9%). Indications for ERS were: homograft rupture two pts, dislodgment of the stented valve in a dilated right ventricular outflow tract two pts, occlusion of the right pulmonary artery one pt and compression of the left main coronary artery one pt. Cardiopulmonary bypass was established through repeat sternotomy incision with femorofemoral cannulation in 2/6 pts. The stented valve was removed in five and replaced with a homograft in three and a valved conduit in two pts. One ruptured homograft was repaired leaving the stented valve in situ. All patients survived, one sustained mild neurological impairment. CONCLUSION: Although some of the acute complications of PPVI were probably related to a learning curve (4 among the first 50 pts and 2 among the last 102 patients) the need for ERS is unlikely to be completely abolished. This experience highlights the importance of close collaboration between cardiologists and surgeons in these evolving technologies. Highly skilled and responsive surgical back up is necessary to support the introduction and to sustain institutional programmes such as PPVI.


Asunto(s)
Puente Cardiopulmonar/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/cirugía , Válvula Pulmonar/cirugía , Terapia Recuperativa/métodos , Adolescente , Adulto , Procedimientos Quirúrgicos Cardiovasculares/métodos , Procedimientos Quirúrgicos Cardiovasculares/tendencias , Niño , Urgencias Médicas , Femenino , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Masculino , Complicaciones Posoperatorias/fisiopatología , Válvula Pulmonar/fisiología , Trasplante Homólogo
19.
Circulation ; 113(17): 2037-44, 2006 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-16636174

RESUMEN

BACKGROUND: Right ventricular outflow tract obstruction (RVOTO) is a common problem after repair of congenital heart disease. Percutaneous pulmonary valve implantation (PPVI) can treat this condition without consequent pulmonary regurgitation or cardiopulmonary bypass. Our aim was to investigate the clinical and physiological response to relieving RVOTO. METHODS AND RESULTS: We studied 18 patients who underwent PPVI for RVOTO (72% male, median age 20 years) from a total of 93 who had this procedure for various indications. All had a right ventricular outflow tract (RVOT) gradient >50 mm Hg on echocardiography without important pulmonary regurgitation (less than mild or regurgitant fraction <10% on magnetic resonance imaging [MRI]). Cardiopulmonary exercise testing, tissue Doppler echocardiography, and MRI were performed before and within 50 days of PPVI. PPVI reduced RVOT gradient (51.4 to 21.7 mm Hg, P<0.001) and right ventricular systolic pressure (72.8 to 47.3 mm Hg, P<0.001) at catheterization. Symptoms and aerobic (25.7 to 28.9 mL.kg(-1).min(-1), P=0.002) and anaerobic (14.4 to 16.2 mL.kg(-1).min(-1), P=0.002) exercise capacity improved. Myocardial systolic velocity improved acutely (tricuspid 4.8 to 5.3 cm/s, P=0.05; mitral 4.7 to 5.5 cm/s, P=0.01), whereas isovolumic acceleration was unchanged. The tricuspid annular velocity was not maintained on intermediate follow-up. Right ventricular end-diastolic volume (99.9 to 89.7 mL/m2, P<0.001) fell, whereas effective stroke volume (43.7 to 48.3 mL/m2, P=0.06) and ejection fraction (48.0% to 56.8%, P=0.01) increased. Left ventricular end-diastolic volume (72.5 to 77.4 mL/m2, P=0.145), stroke volume (45.3 to 50.6 mL/m2, P=0.02), and ejection fraction (62.6% to 65.8%, P=0.03) increased. CONCLUSIONS: PPVI relieves RVOTO, which leads to an early improvement in biventricular performance. Furthermore, it reduces symptoms and improves exercise tolerance. These findings have important implications for the management of this increasingly common condition.


Asunto(s)
Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Pulmonar/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Adulto , Presión Sanguínea , Niño , Ecocardiografía Doppler , Prueba de Esfuerzo , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Stents , Función Ventricular Izquierda
20.
Biorheology ; 44(4): 265-72, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-18094450

RESUMEN

A non-biodegradable polyhedral oligomeric silsesquioxane (POSS) nanocomposite biopolymer has been developed for fabrication of medical devices and for tissue engineering human organs. The polymer in solution, containing 2 wt% of POSS, has been synthesized, characterized and investigated to determine its key rheological properties. Thus, the variation of shear stress and viscosity as a function of shear rate has been determined at ambient temperature to estimate yield stress and the index of pseudoplasticity, respectively. The temperature dependence of viscosity and the effect of ageing on the viscosity of the polymer have also been investigated. Results are compared with those of a conventional polycarbonate urethane (PCU) polymer solution. The POSS-PCU polymer solution shows near-Newtonian behaviour in the shear rate range to 1000 s(-1), having an apparent viscosity of approximately 3000 mPa s and a pseudoplasticity index of 0.90, decreasing slightly as the polymer solution is aged over 9 months. The temperature dependence of viscosity of the POSS polymer is extremely low and does not change with ageing but the yield strength increases from 2.7 Pa to 8.3 Pa.


Asunto(s)
Materiales Biocompatibles/química , Nanocompuestos/química , Compuestos de Organosilicio/química , Reología , Biopolímeros , Fenómenos Químicos , Química Física , Peso Molecular , Viscosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA