Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 46(10): 1215-1221, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37676730

RESUMEN

Video-assisted thoracoscopic surgery (VATS) has revolutionized the approach and management of pulmonary and cardiac diseases, and its applications have significantly expanded in the last two decades. Beyond its established role in thoracic procedures, VATS has also emerged as a valuable technique for various electrophysiological procedures, including pacemaker implantations, ablation procedures, and left atrial appendage exclusion. This paper presents a thorough review of the existing literature on pacing procedures performed using a VATS approach. By analyzing and synthesizing the available studies, we aim to provide an in-depth understanding of the current knowledge and advancements in VATS-based pacing procedures. A key focus of this review is the detailed description of implantation techniques via a VATS approach.


Asunto(s)
Cardiopatías , Marcapaso Artificial , Humanos , Cirugía Torácica Asistida por Video/métodos
2.
Medicina (Kaunas) ; 59(2)2023 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-36837606

RESUMEN

Electrical storm is a medical emergency characterized by ventricular arrythmia recurrence that can lead to hemodynamic instability. The incidence of this clinical condition is rising, mainly in implantable cardioverter defibrillator patients, and its prognosis is often poor. Early acknowledgment, management and treatment have a key role in reducing mortality in the acute phase and improving the quality of life of these patients. In an emergency setting, several measures can be employed. Anti-arrhythmic drugs, based on the underlying disease, are often the first step to control the arrhythmic burden; besides that, new therapeutic strategies have been developed with high efficacy, such as deep sedation, early catheter ablation, neuraxial modulation and mechanical hemodynamic support. The aim of this review is to provide practical indications for the management of electrical storm in acute settings.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Humanos , Calidad de Vida , Arritmias Cardíacas , Antiarrítmicos/uso terapéutico , Pronóstico
3.
Pacing Clin Electrophysiol ; 44(8): 1404-1412, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34224159

RESUMEN

PURPOSE: To compare the outcome of paroxysmal atrial fibrillation (AF) ablation via pulmonary vein isolation using Ablation Index (AI) with strict or standard stability criteria. METHODS: We enrolled 130 consecutive naive patients affected by paroxysmal AF who underwent PVI at two high-volume centers. AI target was ≥380 at the posterior wall and ≥500 at the anterior wall. Strict versus standard stability criteria were set for Group 1 (65 patients) and Group 2 (65 patients), respectively. We compared those strategies with a historical cohort of 72 consecutive patients treated at same centers in the VISITALY study, using average force ≥10 g and strict stability criteria as target parameters. Interlesion distance target was <6 mm. Recurrence was defined as any AF, atrial tachycardia (AT) or atrial flutter (AFL) during the 12 months after ablation, excluding a 90-days blanking period. RESULTS: Procedure duration (224.05 ± 47.21 vs. 175.61 ± 51.29 min; p < .001), fluoroscopy time (11.85 ± 4.38 vs. 10.46 ± 6.49 min; p = .019) and pericardial effusion rate (9.23% vs. 0%; p = .01) were higher in Group 1 than in Group 2. Freedom from AF/AT/AFL at 12 months was not significantly different (Group 1: 86.15%; Group 2: 90.77%; p = .42). Compared to VISITALY study, there were not significant differences in terms of recurrences. CONCLUSION: A strategy of PVI using AI with standard stability criteria performed the best in terms of procedure efficiency and safety. Twelve-months arrhythmia-free survival rate was comparable with other strategies pursuing an interlesion distance target <6 mm, regardless of the use of AI.


Asunto(s)
Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Ablación por Radiofrecuencia/normas , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Estudios Retrospectivos
4.
J Cardiovasc Electrophysiol ; 31(8): 2187-2191, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32495408

RESUMEN

INTRODUCTION: The most appropriate treatment for stroke prevention in standalone atrial fibrillation patients with a high CHADS2VASC score contraindicated for oral anticoagulation (OAC) or novel OAC (NOAC) still needs to be defined. Percutaneous left atrial appendage (LAA) closure devices are available, but because of their endocardial positioning need a period of antiplatelet therapy (APT). This study aimed to evaluate the safety and efficacy of epicardial left atrial appendage clipping in patients contraindicated for (N)OAC and APT. METHODS AND RESULTS: We describe a standalone totally thoracoscopic LAA clipping of forty-five consecutive patients with nonvalvular atrial fibrillation (NVAF; 32 males; age, 73.1 ± 7.4 years; CHADVASC, 6.5 ± 1.1; HAS-BLED 4.9 ± 0.9) with absolute contraindications to (N)OAC. The patients were selected by a multidisciplinary Heart Team. Sixty percent had a previous ischemic stroke and 51% a history of the hemorrhagic event and 22% both. All patients were implanted with an LAA epicardial clip, guided by preoperative computed tomography and intraoperative transesophageal echocardiography. The mean procedural duration was 52.3 ± 12.6 minutes with postprocedural extubation interval of 22.8 ± 14.6 minutes. No procedure-related complications occurred. Intraprocedural transesophageal echocardiography (TEE) showed complete LAA occlusion in all patients. At a mean follow-up of 16.4 ± 9.1 months (range, 2-34), with all patients off (N)OAC or APT, no ischemic stroke or hemorrhagic complications occurred. computed tomography or TEE at follow-up demonstrated a correct LAA occlusion in all with mean stumps of 3.3 ± 2.8 mm. CONCLUSION: Thoracoscopic epicardial closure of the LAA with the AtriClip PRO2 device is a potentially safe and efficient treatment for stroke prevention in patients with NVAF contraindicated for anticoagulant therapy or APT.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Isquemia Encefálica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Anciano , Anticoagulantes/efectos adversos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Ecocardiografía Transesofágica , Humanos , Masculino , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
5.
Eur Heart J ; 40(15): 1226-1232, 2019 04 14.
Artículo en Inglés | MEDLINE | ID: mdl-30689825

RESUMEN

AIMS: In the Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX (MATRIX) trial, adults with acute coronary syndrome undergoing coronary intervention who were allocated to radial access had a lower risk of bleeding, acute kidney injury (AKI), and all-cause mortality, as compared with those allocated to femoral access. The mechanism of the mortality benefit of radial access remained unclear. METHODS AND RESULTS: We used multistate and competing risk models to determine the effects of radial and femoral access on bleeding, AKI and all-cause mortality in the MATRIX trial and to disentangle the relationship between these different types of events. There were large relative risk reductions in mortality for radial compared with femoral access for the transition from AKI to death [hazard ratio (HR) 0.55, 95% confidence interval (CI) 0.31-0.97] and for the pathway from coronary intervention to AKI to death (HR 0.49, 95% CI 0.26-0.92). Conversely, there was little evidence for a difference between radial and femoral groups for the transition from bleeding to death (HR 1.05, 95% CI 0.42-2.64) and the pathway from coronary intervention to bleeding to death (HR 0.84, 95% CI 0.28-2.49). CONCLUSION: The prevention of AKI appeared predominantly responsible for the mortality benefit of radial as compared with femoral access in the MATRIX trial. There was little evidence for an equally important, independent role of bleeding.


Asunto(s)
Síndrome Coronario Agudo/mortalidad , Síndrome Coronario Agudo/terapia , Lesión Renal Aguda/prevención & control , Hemorragia/prevención & control , Intervención Coronaria Percutánea/efectos adversos , Síndrome Coronario Agudo/diagnóstico por imagen , Lesión Renal Aguda/etiología , Estudios de Casos y Controles , Angiografía Coronaria/métodos , Arteria Femoral/cirugía , Hemorragia/etiología , Humanos , Intervención Coronaria Percutánea/métodos , Arteria Radial/cirugía , Infarto del Miocardio con Elevación del ST/fisiopatología , Resultado del Tratamiento
6.
Echocardiography ; 35(5): 750-752, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29569266

RESUMEN

Mitral regurgitation secondary to accessory mitral valve (MV) chordae of the left atrium is an extremely rare congenital disease. A 85-year-old female (NYHA I-II) was hospitalized for investigations. An echocardiogram showed calcification of the MV with mild stenosis and moderate regurgitation. Transesophageal three-dimensional echocardiogram revealed a band-like structure extending from the distal third of the anterior wall of the left atrium to the MV. This accessory chordae determined severe systolic regurgitation and mild mitral stenosis. The patient was referred for consideration of cardiac surgery but was refused for comorbidities and anatomy. Usually aberrant chordae determinant valvulopathies are detected and treated at a much younger age. The delay of the symptoms could be explained in our case with the progressive growth and dilatation of the left atrium causing traction of the aberrant chord resulting in an increase in the leaflet prolapse and regurgitation.


Asunto(s)
Cuerdas Tendinosas/diagnóstico por imagen , Diagnóstico Tardío , Ecocardiografía Doppler en Color/métodos , Ecocardiografía Transesofágica , Cardiopatías Congénitas/complicaciones , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/anomalías , Anciano de 80 o más Años , Cuerdas Tendinosas/anomalías , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Índice de Severidad de la Enfermedad
7.
Pediatr Cardiol ; 39(8): 1581-1589, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29948026

RESUMEN

The aim of this study is to evaluate the cost-effectiveness of an extended use of 3D non-fluoroscopic mapping systems (NMSs) during paediatric catheter ablation (CA) in an adult EP Lab. This study includes 58 consecutive patients (aged between 8 and 18) who underwent CA from March 2005 to February 2015. We compare the fluoroscopy data of two groups: group I, patients who underwent CA from 2005 to 2008 using only fluoroscopy, and group II, patients who underwent CA from 2008 to 2015 performed also using NMSs. Two cost-effectiveness analyses were carried out: the first method was based on the alpha value (AV), and the second one was based on the value of a statistical life (VSL). For both methods, a children's correction factor was also considered. The reduction cost estimated from all these methods was compared to the real additional cost of using NMSs. The use of an NMS during a CA procedure has led to an effective dose reduction (ΔE) of 2.8 milli-Sievert. All presented methods are based on parameters with a wide range of values. The use of an NMS, applying directly AV values or VSL values, is not cost-effective for most countries. Only considering the children's correction factor, the CA procedure using an NMS seems to be cost-effective. The cost-effectiveness of a systematic use of NMSs during CA procedures in children and teenagers remains a challenging task. A positive result depends on which value of AV or VSL is considered and if the children's correction factor is applied or not.


Asunto(s)
Ablación por Catéter/métodos , Fluoroscopía/economía , Imagenología Tridimensional/economía , Adolescente , Mapeo del Potencial de Superficie Corporal/economía , Ablación por Catéter/economía , Niño , Análisis Costo-Beneficio , Femenino , Fluoroscopía/métodos , Humanos , Masculino , Exposición a la Radiación/prevención & control
8.
Pediatr Cardiol ; 37(4): 802-9, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26932365

RESUMEN

Standard imaging during electrophysiological procedures (EPs) uses fluoroscopy. The aim of this study was to evaluate the feasibility, efficacy, safety and effect of an extended use of non-fluoroscopic mapping systems (NMSs) for imaging during paediatric EPs in an adult EP laboratory focusing on the amount of X-ray exposure. This study is a retrospective analysis that includes consecutive young patients (83 pts, aged between 8 and 18) who underwent EPs from March 2005 to February 2015. We compare the fluoroscopy data of two groups of pts: Group I, pts who underwent EPs from 2005 to 2008 using only fluoroscopy and Group II, pts who underwent EPs from 2008 to 2015 performed also using NMSs. The use of an NMS resulted in reduced fluoroscopy time in Group II {median value 0.1 min (95 % CI [0.00-1.07])} compared to Group I {median value 3.55 min (95 % CI [1.93-7.83]) (MW test, P < 0.05)}. There was a complementary reduction in the total X-ray exposure from 2.53 Gy cm(2) (95 % CI [1.51-4.66]) in Group I to 0.05 Gy cm(2) in Group II (95 % CI [0.00-1.22]) (MW test, P < 0.05). Regarding ablation procedures, the median effective dose decreased from 3.04 mSv (95 % CI [1.22-6.89]) to 0.25 mSv (95 % CI [0.00-0.60]) (MW test, P < 0.05). The use of an NMS dramatically reduces fluoroscopy time and total X-ray exposure during EPs in children and teenagers in an adult EP laboratory. In our experience, this reduction is mainly related to the systematic day-to-day use of NMSs.


Asunto(s)
Arritmias Cardíacas/cirugía , Ablación por Catéter/métodos , Fluoroscopía , Imagenología Tridimensional/métodos , Dosis de Radiación , Adolescente , Niño , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Estudios Retrospectivos
9.
G Ital Cardiol (Rome) ; 24(6): 432-435, 2023 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-37227202

RESUMEN

BACKGROUND: Telemedicine enables patients to receive better care via the simplification of procedures while allowing for a significant reduction of in-office appointments and emergency room visits. The "Cardiologia in linea" project started with the objective of strengthening communications between cardiologists and primary care, particularly with general practitioners. METHODS: Between January 2017 and October 2022, by means of a facilitated telephonic and digital contact between territorial professionals and the cardiologist, the project provided in most cases immediate answers to cardiology queries, which were logged. RESULTS: A total of 2066 telephonic or digital consultations have been recorded, originating from 316 general practitioners in the Trento province (Italy). The mean age of patients was 76.4 years, 53% were male. After consultation, an immediate response was provided in 1989 (96%) of cases. A total of 1112 (54%) cardiology visits were avoided. After the consultation, a cardiologic visit was suggested in 29 cases (1%), and the emergency system was activated in 20 cases (1%). Overall, most questions concerned direct oral anticoagulant prescriptions (537 cases, 31%) and anti-hypertensive treatment (241 cases, 14%). CONCLUSIONS: The "Cardiologia in linea" project demonstrated a low-cost improvement in the patient assistance workflow, in the communication between hospital cardiology and primary care, while reducing the number of emergency room accesses. The project successfully shows the feasibility of a real-time dialogue between the general practitioner and the hospital cardiologist.


Asunto(s)
Cardiólogos , Consulta Remota , Humanos , Masculino , Anciano , Femenino , Consulta Remota/métodos , Derivación y Consulta , Hospitales , Italia , Atención Primaria de Salud/métodos
10.
J Clin Med ; 12(11)2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37297857

RESUMEN

Drug coated balloons (DCBs) are currently indicated in guidelines as a first choice option in the management of instant restenosis, whereas their use in de novo lesions is still debated. The concerns raised after the contrasting results of the initial trials with DCBs in de novo lesions have been more recently overcome by a larger amount of data confirming their safety and effectiveness as compared to drug-eluting stents (DES), with potentially greater benefits being achieved, especially in particular anatomical settings, as in very small or large vessels and bifurcations, but also in selected subsets of higher-risk patients, where a 'leave nothing behind' strategy could offer a reduction of the inflammatory stimulus and thrombotic risk. The present review aims at providing an overview of current available DCB devices and their indications of use based on the results of data achieved so far.

11.
Am J Cardiol ; 206: 73-78, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37683582

RESUMEN

Patients with diabetes mellitus (DM) are at higher risk of restenosis and stent thrombosis after percutaneous coronary intervention (PCI) and drug-eluting stent (DES) positioning. Whether drug-coated balloons (DCB) can offer any benefit in this subset of patients has been seldom cleared out and was the aim of the present propensity-matched cohort study, that compared the prognostic impact of DCB versus DES in patients with DM who underwent PCI. Patients with DM enrolled in the NOvara-BIella-TREnto (NOBITRE) Registry were identified and matched according to propensity score, to a control population of patients with DM treated with DES. The primary study end point was the occurrence of major adverse cardiovascular events (MACEs). A total of 150 patients were identified in the DCB group and matched with 150 DES-treated patients. Patients treated with DCB displayed more often a previous cardiovascular history and received a more complete pharmacological therapy. Target vessel diameter and the percentage of stenosis were lower in patients with DCB, whereas binary in-stent restenosis was more common (p <0.001, p = 0.003, and p <0.001, respectively). Paclitaxel-eluting balloon represented the most common strategy in the DCB group, whereas Zotarolimus-eluting stents were used in half of the DES population. At a median follow-up of 545.5 days, MACE occurred in 54 (19.4%) of patients, with no difference according to the PCI strategy (21.6% vs 17.3%, adjusted hazard ratio [95% confidence interval] 1.51 [0.46 to 4.93], p = 0.50). Major ischemic end points were slightly increased in patients treated with DCB, whereas overall death was significantly reduced (3.6% vs 10.9%; adjusted hazard ratio [95% confidence interval] 0.27 [0.08 to 0.91], p = 0.03). In conclusion, the present propensity-matched study shows that, in patients with DM who underwent PCI for in-stent restenosis or de novo lesions, the use of DCB is associated with a similar rate of MACE and a modest increase in target lesion failure, but a significantly improved survival as compared with DES.

12.
Angiology ; 74(5): 488-495, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37005331

RESUMEN

Drug-coated balloons (DCBs) have emerged for percutaneous coronary interventions (PCI) of in-stent restenosis or particular anatomical subsets. We provide a real-world analysis of the prognostic determinants and long-term outcomes of patients treated with DCB for any lesion in a comprehensive multicenter registry. The primary study endpoint was the occurrence of major cardiovascular events (MACE: composite of all-cause death, myocardial infarction, and target vessel revascularization) at the longest available follow-up. We included 267 patients (196 treated for in-stent restenosis and 71 for de novo lesions), with a median follow-up of 616 [368-1025] days. MACE occurred in 70 (26.2%) of the patients and related with higher rates of in-stent restenosis (P = .04), longer and more type C lesions (P = .05 and P = .04). At multivariate Cox-regression, type C lesions emerged as the only independent predictor of MACE (adjusted OR [95% CI] = 1.83[1.13-2.97], P = .014), mainly driven by target vessel revascularization (adjusted OR[95% CI] = 1.78[1.05-2.95], P = .03) not conditioning survival. In-stent restenosis emerged as major determinant of TLF (adjusted OR[95% CI] = 2.59[1.17-5.75], P = .02). DCBs represent a treatment option for any lesion; however, type C and restenotic lesions are associated with an increased risk of MACE and target lesion failure, where the optimal strategies for patients' selection and lesion preparation are still undefined.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Stents Liberadores de Fármacos/efectos adversos , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Factores de Riesgo , Resultado del Tratamiento , Fármacos Cardiovasculares/efectos adversos , Sistema de Registros
13.
J Cardiovasc Med (Hagerstown) ; 24(3): 191-199, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36753726

RESUMEN

AIMS: To assess the characteristics of left atrial appendage (LAA) stump and left atrial (LA) volume after standalone totally thoracoscopic LAA exclusion in 40 patients with nonvalvular atrial fibrillation (NVAF) and contraindications to oral anticoagulation (OAC), using cardiac computed tomography (CCT) and transoesophageal echocardiography (TOE). METHODS: Using CCT and TOE, we evaluated correct AtriClip Pro II positioning, the presence and characteristics of the LAA stump and the postprocedural LA volume, at 3 months' follow-up. Stump depth was measured with both CCT and TOE using a new method, based on left circumflex artery (LCX) course. RESULTS: After placement of AtriClip, all 40 patients discontinued OAC, and no stroke occurred. LAA exclusion was achieved in 40/40 patients at 3 months' follow-up. LAA stump (depth <10 mm in 12/18 stump, 67%) was observed in 18 patients. The overall (LA + LAA) volume and isolated LA volume were statistically different when comparing cases with and without LAA stump (P < 0.02). LAA ostium dimensions (perimeter and area) and LAA volume correlate with stump depth (P < 0.02). There was a high correlation between CCT and TOE in stump identification and depth measurement (P < 0.02). Compared with the baseline, CCT LA volume increased (P < 0.01) at 3 months' follow-up. CONCLUSION: Preprocedural and postprocedural CCT and TOE are useful and comparable in patients undergoing standalone totally thoracoscopic exclusion of LAA, because these imaging methods can identify anatomical LAA and LA characteristics predisposing for a postprocedural residual stump.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Accidente Cerebrovascular/etiología
14.
Life (Basel) ; 13(8)2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37629509

RESUMEN

The difference between subcutaneous implantable cardioverter defibrillators (S-ICDs) and transvenous ICDs (TV-ICDs) concerns a whole extra thoracic implantation, including a defibrillator coil and pulse generator, without endovascular components. The improved safety profile has allowed the S-ICD to be rapidly taken up, especially among younger patients. Reports of its role in different cardiac diseases at high risk of SCD such as hypertrophic and arrhythmic cardiomyopathies, as well as channelopathies, is increasing. S-ICDs show comparable efficacy, reliability, and safety outcomes compared to TV-ICD. However, some technical issues (i.e., the inability to perform anti-bradycardia pacing) strongly limit the employment of S-ICDs. Therefore, it still remains only an alternative to the traditional ICD thus far. This review aims to provide a contemporary overview of the role of S-ICDs compared to TV-ICDs in clinical practice, including technical aspects regarding device manufacture and implantation techniques. Newer outlooks and future perspectives of S-ICDs are also brought up to date.

15.
Expert Rev Med Devices ; 20(6): 493-503, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37128658

RESUMEN

Atrial fibrillation is the most common arrythmia and it is linked to an increased risk of stroke. Even if anticoagulation therapy reduces the rate of stroke the benefits of this therapy have to be balanced with the increased risk of hemorrhagic event. Left atrial appendage closure is a valid alternative to long-term anticoagulation in patients with atrial fibrillation and high hemorrhagic risk. Actually new devices with different features have been tested and introduced progressively in the clinical practice. Improvements in preprocedural imaging evaluation and the learning curve of the operators led to percutaneous left atrial appendage closure a safe and effective procedure. A good knowledge of different devices and the technique of implant is necessary for optimization percutaneous left atrial appendage closure and the reduction of complications during the acute phase and follow up.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Anticoagulantes/uso terapéutico , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Resultado del Tratamiento , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Hemorragia/inducido químicamente , Hemorragia/complicaciones , Cateterismo Cardíaco
16.
Front Cardiovasc Med ; 10: 1151167, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37304964

RESUMEN

Introduction: Remote monitoring (RM) technologies have the potential to improve patient care by increasing compliance, providing early indications of heart failure (HF), and potentially allowing for therapy optimization to prevent HF admissions. The aim of this retrospective study was to assess the clinical and economic consequences of RM vs. standard monitoring (SM) through in-office cardiology visits, in patients carrying a cardiac implantable electronic device (CIED). Methods: Clinical and resource consumption data were extracted from the Electrophysiology Registry of the Trento Cardiology Unit, which has been systemically collecting patient information from January 2011 to February 2022. From a clinical standpoint, survival analysis was conducted, and incidence of cardiovascular (CV) related hospitalizations was measured. From an economic standpoint, direct costs of RM and SM were collected to compare the cost per treated patient over a 2-year time horizon. Propensity score matching (PSM) was used to reduce the effect of confounding biases and the unbalance of patient characteristics at baseline. Results: In the enrollment period, N = 402 CIED patients met the inclusion criteria and were included in the analysis (N = 189 patients followed through SM; N = 213 patients followed through RM). After PSM, comparison was limited to N = 191 patients in each arm. After 2-years follow-up since CIED implantation, mortality rate for any cause was 1.6% in the RM group and 19.9% in the SM group (log-rank test, p < 0.0001). Also, a lower proportion of patients in the RM group (25.1%) were hospitalized for CV-related reasons, compared to the SM group (51.3%; p < 0.0001, two-sample test for proportions). Overall, the implementation of the RM program in the Trento territory was cost-saving in both payer and hospital perspectives. The investment required to fund RM (a fee for service in the payer perspective, and staffing costs for hospitals), was more than offset by the lower rate of hospitalizations for CV-related disease. RM adoption generated savings of -€4,771 and -€6,752 per patient in 2 years, in the payer and hospital perspective, respectively. Conclusion: RM of patients carrying CIED improves short-term (2-years) morbidity and mortality risks, compared to SM and reduces direct management costs for both hospitals and healthcare services.

17.
Prog Cardiovasc Dis ; 81: 42-47, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37852517

RESUMEN

BACKGROUND: Myocardial infarction (MI) with non-obstructed coronary arteries (MINOCA) is an increasingly recognized condition with challenging management. Some MINOCA patients ultimately experience recurrent acute MI (re-AMI) during follow-up; however, clinical and angiographic factors predisposing to re-AMI are still poorly defined. METHODS: In this retrospective multicenter cohort study we enrolled consecutive patients fulfilling diagnostic criteria of MINOCA according to the IV universal definition of myocardial infarction; characteristics of patients experiencing re-AMI during the follow-up were compared to a group of MINOCA patients without re-AMI. RESULTS: 54 patients (mean age 66 ± 13) experienced a subsequent re-AMI after MINOCA and follow-up was available in 44 (81%). Compared to MINOCA patients without re-AMI (n = 695), on first invasive coronary angiography (ICA) MINOCA patients with re-AMI showed less frequent angiographically normal coronaries (37 versus 53%, p = 0.032) and had a higher prevalence of atherosclerosis involving 3 vessels or left main stem (17% versus 8%, p = 0.049). Twenty-four patients (44%) with re-AMI underwent a new ICA: 25% had normal coronary arteries, 12.5% had mild luminal irregularities (<30%), 20.8% had moderate coronary atherosclerosis (30-49%), and 41.7% showed obstructive coronary atherosclerosis (≥50% stenosis). Among patients undergoing new ICA, atherosclerosis progression was observed in 11 (45.8%), 37.5% received revascularization, only 4.5% had low-density lipoprotein cholesterol (LDL_C) under 55 mg/dL and 33% experienced a new cardiovascular disease (CVD) event (death, AMI, heart failure, stroke) at subsequent follow-up. CONCLUSIONS: In the present study, only a minority of MINOCA patients with re-AMI underwent a repeated ICA, nearly one out of two showed atherosclerosis progression, often requiring revascularization. Recommended LDL-C levels were achieved only in a minority of the cases, indicating a possible underestimation of CVD risk in this population.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Humanos , Persona de Mediana Edad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/terapia , MINOCA , Estudios de Cohortes , Angiografía Coronaria , Factores de Riesgo , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Infarto del Miocardio/terapia , Vasos Coronarios
18.
Minerva Cardiol Angiol ; 71(1): 12-19, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36305773

RESUMEN

BACKGROUND: The COVID-19 pandemic severely impacted global health. The aim of this study was to compare predictors of symptoms-to-emergency-call timing delay in acute coronary syndrome (ACS) and their impact on mortality before and during the COVID-19 outbreak. METHODS: We collected sociodemographic, clinical data, procedural features, preadmission and intra-hospital outcomes of consecutive patients admitted for ACS in seventeen Italian centers from March to April 2018, 2019, and 2020. RESULTS: In 2020, a 32.92% reduction in ACS admissions was observed compared to 2018 and 2019. Unstable angina, typical and atypical symptoms, and intermittent angina were identified as significant predictors of symptoms-to-emergency-call timing delay before and during the COVID-19 pandemic (P<0.005 for all the items). Differently from 2018-2019, during the pandemic, hypertension and dyspnea (P=0.002 versus P=0.490 and P=0.001 vs. P=0.761 for 2018-2019 and 2020, respectively) did not result as predictors of delay in symptoms-to-emergency-call timing. Among these predictors, only the atypical symptoms (HR 3.36; 95% CI: 1.172-9.667, P=0.024) in 2020 and the dyspnea (HR 2.64; 95% CI: 1.345-5.190, P=0.005) in 2018-2019 resulted significantly associated with higher mortality. Finally, the family attendance at the onset of the symptoms resulted in a reduction in symptoms-to-emergency-call timing (in 2020 P<0.001; CI: -1710.73; -493.19) and in a trend of reduced mortality (HR 0.31; 95% CI: 0.089-1.079, P=0.066) in 2020. CONCLUSIONS: During the COVID-19 outbreak, atypical symptoms and family attendance at ACS onset were identified, respectively, as adverse and favorable predictors of symptoms-to-emergency-call timing delay and mortality.


Asunto(s)
Síndrome Coronario Agudo , COVID-19 , Humanos , COVID-19/epidemiología , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/epidemiología , Pandemias , Angina Inestable/epidemiología , Disnea/epidemiología
19.
Europace ; 14(1): 107-11, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21856676

RESUMEN

AIMS: The aim of this study is to show the feasibility of a biventricular implantable cardioverter-defibrillator [cardiac resynchronization therapy (CRT)-ICD] implantation using an electroanatomic navigation system and a low dose of fluoroscopy. Here four case reports of patients affected by dilated cardiomyopathy, who underwent cardiac resynchronization therapy, are described. METHODS AND RESULTS: During 2010, four patients were admitted to our Cardiology Department for implantation of an CRT-ICD device in primary prevention. All had an ejection fraction of <35% and were in New York Heart Association class III despite optimal medical therapy. The implantations were performed using the EnSite NavX system. All the leads were positioned in the cardiac chambers utilizing the three-dimensional navigation system and only using X-ray to check that the leads had been positioned correctly. To our knowledge, these cases are the first use of an electroanatomic system for implantation of an CRT-ICD device and in all four cases the cannulation of the coronary sinus (CS) was performed only using the mapping system. Electroanatomic navigation made it possible to minimize X-ray exposure during the implantation of the CRT-ICD device; in addition, the mapping system was used to choose the optimum position of the CS catheter using as reference the maximum activation delay between the two ventricles. CONCLUSIONS: The NavX system shows great potential during the implantation of an CRT-ICD device. It seems to be feasible, safe, and extremely beneficial in terms of a reduction in X-ray exposure. Furthermore, there is benefit of more detailed information and accuracy during the CS lead placement.


Asunto(s)
Técnicas de Imagen Cardíaca/instrumentación , Procedimientos Quirúrgicos Cardíacos/instrumentación , Cardiomiopatía Dilatada/cirugía , Desfibriladores Implantables , Implantación de Prótesis/métodos , Anciano , Anciano de 80 o más Años , Técnicas de Imagen Cardíaca/métodos , Seno Coronario/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico/fisiología
20.
Minerva Cardiol Angiol ; 70(4): 468-475, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33703854

RESUMEN

BACKGROUND: Northern Italy has been one of the most affected area in the world by the novel severe acute respiratory syndrome Coronavirus 2 (SARS-CoV-2). The healthcare system has been overwhelmed by the huge number of patients in need of mechanical ventilation or intensive care, resulting in a delay of treatment of patients with acute coronary syndrome (ACS), due to a crash in STEMI networks and closure of a certain number of hub centers, and to a delay in patients' seeking for medical evaluation for chest pain or angina-equivalent symptoms. METHODS: In the Trentino region, a mountainous area with about 500,000 inhabitants, very close to Lombardy that was the epicenter of the pandemic in Italy, to avoid these dramatic consequences, we developed a new protocol tailored to our specificity to keep our institution, and above all the cath-lab, clean from the SARS-CoV-2 infection, to ensure full operativity for cardiologic emergencies. RESULTS: Applying this protocol during the two months of the peak of the infection in Italy no one of the staff members of the cath-lab, the ICCU or the cardiology ward tested positive to nasal swab for SARS-CoV-2 and the same result was obtained for all the patients admitted to our units. CONCLUSIONS: Our real-world experience shows that during the COVID-19 pandemic, quick activation of an appropriate protocol defining specific pathways for patients with a medical urgency is effective in minimizing healthcare personnel exposure and to preserve full operativity of the hub centers. This issue will be of a crucial importance, now that we are facing the second wave of the pandemic.


Asunto(s)
COVID-19 , Cardiología , Infarto del Miocardio con Elevación del ST , COVID-19/epidemiología , Humanos , Pandemias/prevención & control , SARS-CoV-2 , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/epidemiología , Infarto del Miocardio con Elevación del ST/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA