1.
Eur J Nucl Med Mol Imaging ; 43(7): 1315-22, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26780619

RESUMEN

PURPOSE: Even though [(123)I]FP-CIT SPECT provides high accuracy in detecting nigrostriatal cell loss in neurodegenerative parkinsonian syndromes (PS), some patients with an inconclusive diagnosis remain. We investigated whether the diagnostic accuracy in patients with clinically uncertain PS with previously inconclusive findings can be improved by the use of iterative reconstruction algorithms and an improved semiquantitative evaluation which additionally implemented a correction algorithm for patient age and gamma camera dependency (EARL-BRASS; Hermes Medical Solutions, Sweden). METHODS: We identified 101 patients with inconclusive findings who underwent an [(123)I]FP-CIT SPECT between 2003 and 2010 as part of the diagnostic process of suspected PS at the University of Munich, and re-evaluated these scans using iterative reconstruction algorithms and the new corrected EARL-BRASS. Clinical follow-up was obtained in 62 out of the 101 patients and constituted the gold standard for the re-evaluation to assess the possible improvement in diagnostic accuracy. RESULTS: Clinical follow-up confirmed the diagnosis of PS in 11 of the 62 patients. In patients in whom both visual and semiquantitative analysis showed concordant findings (48 patients), a high negative predictive value (93 %), positive predictive value (100 %) and accuracy (94 %) were found, and thus a correct diagnosis was obtained in 45 of the 48 patients. Among the 14 patients with discordant findings, the additional semiquantitative analysis correctly identified all five of nine patients patients without PS by nonpathological semiquantitative findings in visually pathological or inconclusive scans. In contrast, four of the remaining five patients with decreased semiquantitative values but visually normal scans did not show a PS during follow-up. CONCLUSION: The age-corrected and camera-corrected mode of evaluation using EARL-BRASS provided a notable improvement in the diagnostic accuracy of [(123)I]FP-CIT SPECT in PS patients with previously inconclusive findings. The gain in accuracy might be achieved by better discrimination between physiological low striatal [(123)I]FP-CIT binding due to age-related loss of the dopamine transporter or pathological loss of binding.


Asunto(s)
Bases de Datos Factuales , Trastornos Parkinsonianos/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único , Tropanos , Incertidumbre , Estudios de Casos y Controles , Europa (Continente) , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
2.
Health Policy ; 92(2-3): 234-43, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19446356

RESUMEN

OBJECTIVE: The aim of the study is to use the activity-based costing approach to give a better insight in the actual cost structure of a positron emission tomography procedure (FDG-PET) by defining the constituting components and by simulating the impact of possible resource or practice changes. METHODS: The cost data were obtained from the hospital administration, personnel and vendor interviews as well as from structured questionnaires. A process map separates the process in 16 patient- and non-patient-related activities, to which the detailed cost data are related. One-way sensitivity analyses shows to which degree of uncertainty the different parameters affect the individual cost and evaluate the impact of possible resource or practice changes like the acquisition of a hybrid PET/CT device, the patient throughput or the sales price of a 370MBq (18)F-FDG patient dose. RESULTS: The PET centre spends 73% of time in clinical activities and the resting time after injection of the tracer (42%) is the single largest departmental cost element. The tracer cost and the operational time have the most influence on cost per procedure. The analysis shows a total cost per FDG-PET ranging from 859 Euro for a BGO PET camera to 1142 Euro for a 16 slices PET-CT system, with a distribution of the resource costs in decreasing order: materials (44%), equipment (24%), wage (16%), space (6%) and hospital overhead (10%). CONCLUSIONS: The cost of FDG-PET is mainly influenced by the cost of the radiopharmaceutical. Therefore, the latter rather than the operational time should be reduced in order to improve its cost-effectiveness.


Asunto(s)
Costos y Análisis de Costo/métodos , Fluorodesoxiglucosa F18/economía , Tomografía de Emisión de Positrones/economía , Bélgica , Análisis Costo-Beneficio , Investigación sobre Servicios de Salud , Hospitales Universitarios/economía , Humanos , Entrevistas como Asunto , Encuestas y Cuestionarios , Estudios de Tiempo y Movimiento
3.
J Pediatr ; 150(1): 89-95, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17188622

RESUMEN

OBJECTIVE: To validate high serum procalcitonin (PCT) as a predictor of vesicoureteral reflux (VUR) in children with a first febrile urinary tract infection (UTI). STUDY DESIGN: This secondary analysis of prospective hospital-based cohort studies included children ages 1 month to 4 years with a first febrile UTI. RESULTS: Of the 398 patients included in 8 centers in 7 European countries, 25% had VUR. The median PCT concentration was significantly higher in children with VUR than in those without: 1.6 versus 0.7 ng/mL (P = 10(-4)). High PCT (> or =0.5 ng/mL) was associated with VUR (OR: 2.3; 95% CI, 1.3 to 3.9; P = 10(-3)). After adjustment for all cofactors, the association remained significant (OR: 2.5; 95% CI, 1.4 to 4.4; P = 10(-3)). The strength of the relation increased with the grade of reflux (P = 10(-5)). The sensitivity of procalcitonin was 75% (95% CI, 66 to 83) for all-grade VUR and 100% (95% CI, 81 to 100) for grade > or =4 VUR, both with 43% specificity (95% CI, 37 to 48). CONCLUSIONS: High PCT is a strong, independent and now validated predictor of VUR that can be used to identify low-risk patients and thus avoid one third of the unnecessary cystourethrographies in children with a first febrile UTI.


Asunto(s)
Calcitonina/sangre , Precursores de Proteínas/sangre , Infecciones Urinarias/sangre , Infecciones Urinarias/diagnóstico por imagen , Urografía/estadística & datos numéricos , Péptido Relacionado con Gen de Calcitonina , Intervalos de Confianza , Europa (Continente) , Femenino , Estudios de Seguimiento , Glicoproteínas , Humanos , Lactante , Recién Nacido , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos
4.
Clin Nucl Med ; 32(8): 624-7, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17667436

RESUMEN

A 39-year-old healthy female patient with an unremarkable medical history complained about a rapidly progressive pain for a period of 1 month at the level of the anterior part of the right leg that was not relieved by NSAIDs. She mentioned only that she resumed her high level sport training 6 months before the onset of the symptoms. There was no specific history of trauma, fever, or other distinctive symptoms. On clinical examination, the right pretibial skin was inflamed and extremely painful. Walking became difficult the last 2 weeks. No skin injury was observed on the right leg and foot. The early blood tests, consistent with moderate aspecific inflammation, showed a slightly elevated C-reactive protein and sedimentation rate, without any leukocytosis. Upon first consultation the plain radiographs of the right leg were normal, but control radiographs obtained 2 weeks later showed cortical and lamellar lucencies of the right tibial crest.


Asunto(s)
Osteítis/diagnóstico , Infecciones Estreptocócicas/diagnóstico , Streptococcus , Tibia/diagnóstico por imagen , Tibia/patología , Adulto , Femenino , Humanos , Radiografía , Cintigrafía , Enfermedades Raras/diagnóstico , Streptococcus milleri (Grupo)
5.
EJNMMI Res ; 7(1): 10, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28120177

RESUMEN

BACKGROUND: The use of a normal database for [123I]FP-CIT SPECT imaging has been found to be helpful for cases which are difficult to interpret by visual assessment alone, and to improve reproducibility in scan interpretation. The aim of this study was to assess whether the use of different tomographic reconstructions affects the performance of a normal [123I]FP-CIT SPECT database and also whether systems benefit from a system characterisation before a database is used. Seventy-seven [123I]FP-CIT SPECT studies from two sites and with 3-year clinical follow-up were assessed quantitatively for scan normality using the ENC-DAT normal database obtained in well-documented healthy subjects. Patient and normal data were reconstructed with iterative reconstruction with correction for attenuation, scatter and septal penetration (ACSC), the same reconstruction without corrections (IRNC), and filtered back-projection (FBP) with data quantified using small volume-of-interest (VOI) (BRASS) and large VOI (Southampton) analysis methods. Test performance was assessed with and without system characterisation, using receiver operating characteristics (ROC) analysis for age-independent data and using sensitivity/specificity analysis with age-matched normal values. The clinical diagnosis at follow-up was used as the standard of truth. RESULTS: There were no significant differences in the age-independent quantitative assessment of scan normality across reconstructions, system characterisation and quantitative methods (ROC AUC 0.866-0.924). With BRASS quantification, there were no significant differences between the values of sensitivity (67.4-83.7%) or specificity (79.4-91.2%) across all reconstruction and calibration strategies. However, the Southampton method showed significant differences in sensitivity between ACSC (90.7%) vs IRNC (76.7%) and FBP (67.4%) reconstructions with calibration. Sensitivity using ACSC reconstruction with this method was also significantly better with calibration than without calibration (65.1%). Specificity using the Southampton method was unchanged across reconstruction and calibration choices (82.4-88.2%). CONCLUSIONS: The ability of a normal [123I]FP-CIT SPECT database to assess clinical scan normality is equivalent across all reconstruction, system characterisation, and quantification strategies using BRASS quantification. However, when using the Southampton quantification method, performance is sensitive to the reconstruction and calibration strategy used.

6.
EJNMMI Phys ; 4(1): 8, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28130765

RESUMEN

BACKGROUND: [123I]FP-CIT is a well-established radiotracer for the diagnosis of dopaminergic degenerative disorders. The European Normal Control Database of DaTSCAN (ENC-DAT) of healthy controls has provided age and gender-specific reference values for the [123I]FP-CIT specific binding ratio (SBR) under optimised protocols for image acquisition and processing. Simpler reconstruction methods, however, are in use in many hospitals, often without implementation of attenuation and scatter corrections. This study investigates the impact on the reference values of simpler approaches using two quantifications methods, BRASS and Southampton, and explores the performance of the striatal phantom calibration in their harmonisation. RESULTS: BRASS and Southampton databases comprising 123 ENC-DAT subjects, from gamma cameras with parallel collimators, were reconstructed using filtered back projection (FBP) and iterative reconstruction OSEM without corrections (IRNC) and compared against the recommended OSEM with corrections for attenuation and scatter and septal penetration (ACSC), before and after applying phantom calibration. Differences between databases were quantified using the percentage difference of their SBR in the dopamine transporter-rich striatum, with their significance determined by the paired t test with Bonferroni correction. Attenuation and scatter losses, measured from the percentage difference between IRNC and ACSC databases, were of the order of 47% for both BRASS and Southampton quantifications. Phantom corrections were able to recover most of these losses, but the SBRs remained significantly lower than the "true" values (p < 0.001). Calibration provided, in fact, "first order" camera-dependent corrections, but could not include "second order" subject-dependent effects, such as septal penetration from extra-cranial activity. As for the ACSC databases, phantom calibration was instrumental in compensating for partial volume losses in BRASS (~67%, p < 0.001), while for the Southampton method, inherently free from them, it brought no significant changes and solely corrected for residual inter-camera variability (-0.2%, p = 0.44). CONCLUSIONS: The ENC-DAT reference values are significantly dependent on the reconstruction and quantification methods and phantom calibration, while reducing the major part of their differences, is unable to fully harmonize them. Clinical use of any normal database, therefore, requires consistency with the processing methodology. Caution must be exercised when comparing data from different centres, recognising that the SBR may represent an "index" rather than a "true" value.

7.
Clin Nucl Med ; 29(2): 91-2, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-14734904

RESUMEN

We describe a 43-year-old woman who presented a sudden onset of fever and migratory arthralgias. Physical examination revealed tender, well-demarcated erythematous papules and plaques, consistent with a Sweet syndrome. After developing systemic symptoms with hepatomegaly, a liver biopsy and FDG PET imaging demonstrated the presence of an aggressive and extended non-Hodgkin T-cell lymphoma. This case highlights the usefulness of FDG PET imaging for the screening of this paraneoplastic syndrome.


Asunto(s)
Fluorodesoxiglucosa F18 , Linfoma no Hodgkin/diagnóstico por imagen , Síndromes Paraneoplásicos/diagnóstico por imagen , Síndrome de Sweet/diagnóstico por imagen , Tomografía Computarizada de Emisión/métodos , Adulto , Artralgia/diagnóstico por imagen , Femenino , Fiebre de Origen Desconocido/diagnóstico por imagen , Humanos , Radiofármacos
8.
J Gastrointest Surg ; 18(5): 894-905, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24638928

RESUMEN

PURPOSE: We studied the predictive value of [(18) F]fluorodeoxyglucose-positron emission tomography ((18)FDG-PET) for assessing disease-free (DFS) and overall survival (OS) in esophageal and esophagogastric junction cancer. MATERIALS AND METHODS: A literature search (PUBMED/MEDLINE, EMBASE, Cochrane) was performed to identify full papers with (18)FDG-PET and survival data, using indexing terms and free text words. Studies with >10 patients with locally advanced esophageal cancer, presenting sequential or at least one post-adjuvant treatment (18)FDG-PET data and Kaplan-Meier survival curves with >6 months median follow-up period were included. We performed a meta-analysis for DFS and OS using the hazard ratio (HRs) as outcome measure. Sources of heterogeneity study were also explored. RESULTS: We identified 26 eligible studies including a total of 1,544 patients (average age 62 years, 82% males). The TNM distribution was as follows: stage I 7%, II 24%, III 53% and IV 15%. The pooled HRs for complete metabolic response versus no response were 0.51 for OS (95% CI, 0.4-0.64; P < 0.00001) and 0.47 for DFS (95% CI, 0.38-0.57; P < 0.00001), respectively. No statistical heterogeneity was present. To explore sources of clinical heterogeneity, we also realised subgroup and regression analyses. Taken into account the moderate correlation between OS and DFS (ρ = 0.54), we used joint bivariate random regression model. These analyses did not show a statistically significant impact of study characteristics and PET modalities on the pooled outcome estimates. CONCLUSION: Despite methodological and clinical heterogeneity, metabolic response on (18)FDG-PET is a significant predictor of long-term survival data.


Asunto(s)
Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/terapia , Unión Esofagogástrica/diagnóstico por imagen , Tomografía de Emisión de Positrones , Quimioradioterapia Adyuvante , Supervivencia sin Enfermedad , Fluorodesoxiglucosa F18 , Humanos , Terapia Neoadyuvante , Valor Predictivo de las Pruebas , Radiofármacos , Tasa de Supervivencia
9.
EJNMMI Res ; 3(1): 39, 2013 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-23688063

RESUMEN

BACKGROUND: Mesolimbic and nigrostriatal dopaminergic pathways play important roles in both the rewarding and conditioning effects of drugs. The dopamine transporter (DAT) is of central importance in regulating dopaminergic neurotransmission and in particular in activating the striatal D2-like receptors. Molecular imaging studies of the relationship between DAT availability/dopamine synthesis capacity and active cigarette smoking have shown conflicting results. Through the collaboration between 13 SPECT centres located in 10 different European countries, a database of FP-CIT-binding in healthy controls was established. We used the database to test the hypothesis that striatal DAT availability is changed in active smokers compared to non-smokers and ex-smokers. METHODS: A total of 129 healthy volunteers were included. Subjects were divided into three categories according to past and present tobacco smoking: (1) non-smokers (n = 64), (2) ex-smokers (n = 39) and (3) active smokers (n = 26). For imaging of the DAT availability, we used [123I]FP-CIT (DaTSCAN) and single photon emission computed tomography (SPECT). Data were collected in collaboration between 13 SPECT centres located in 10 different European countries. The striatal measure of DAT availability was analyzed in a multiple regression model with age, SPECT centre and smoking as predictor. RESULTS: There was no statistically significant difference in DAT availability between the groups of active smokers, ex-smokers and non-smokers (p = 0.34). Further, we could not demonstrate a significant association between striatal DAT and the number of cigarettes per day or total lifetime cigarette packages in smokers and ex-smokers. CONCLUSION: Our results do not support the hypothesis that large differences in striatal DAT availability are present in smokers compared to ex-smokers and healthy volunteers with no history of smoking.

12.
Laryngoscope ; 120(11): 2213-7, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20949579

RESUMEN

OBJECTIVE: To study the reliability of the sentinel node technique (SNT) in the management of the N0 neck in patients with supraglottic laryngeal cancer. METHODS: Patients presenting to our department, between 2001 and 2004, with T1-T3 supraglottic cancer and N0 neck, clinically and radiologically, were included in the study. All patients underwent sentinel lymph node detection, using the hand-held gamma probe followed by bilateral modified radical neck dissection (MRND) and resection of the primary tumor. We compared the results of the SNT with those of the gold standard MRND for the staging of the neck. The histologic examination was performed after fixation for both the products of SNT and MRND. RESULTS: Twenty-nine patients were included in the study. Twenty-one had T2, 2 had T1, and 6 had T3 tumors. Patients had transoral CO(2) laser-assisted resection of the primary tumor. All the patients underwent bilateral neck dissection immediately after the sentinel node biopsy. Of the 95 sentinel lymph nodes harvested, 22 were positive for lymph node metastasis. The mean number of sentinel node per patient was 3. Of the 58 modified neck dissections (2 neck sides/patient), there was 1 additional positive lymph node, in the prelaryngeal area, and the patient had already positive sentinel lymph nodes. The SNT allowed the identification of node metastasis in 100% of the cases with a sensitivity of 100 (48-100), specificity of 78 (64-88), negative predictive value of 100 (91-100). CONCLUSIONS: SNT is reliable in the staging of the clinically N0 neck in patients with supraglottic cancer.


Asunto(s)
Carcinoma de Células Escamosas/secundario , Carcinoma de Células Escamosas/cirugía , Glotis/patología , Neoplasias Laríngeas/patología , Neoplasias Laríngeas/cirugía , Biopsia del Ganglio Linfático Centinela/métodos , Adulto , Anciano , Biopsia con Aguja , Carcinoma de Células Escamosas/mortalidad , Femenino , Estudios de Seguimiento , Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Inmunohistoquímica , Neoplasias Laríngeas/mortalidad , Ganglios Linfáticos/patología , Ganglios Linfáticos/cirugía , Metástasis Linfática , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Disección del Cuello/métodos , Estadificación de Neoplasias , Pronóstico , Reproducibilidad de los Resultados , Factores de Tiempo , Tomografía Computarizada por Rayos X/métodos
14.
Mov Disord ; 22(16): 2346-51, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17914722

RESUMEN

We previously reported on the role of dopamine transporter (DAT) SPECT in the workup of patients with clinically uncertain parkinsonian syndromes (CUPS). The findings of that study supported the use of SPECT imaging with DaTSCAN ((123)I-Ioflupane) for accurate diagnosis in this population. We report here the 2-year follow-up of the CUPS study, which aimed to validate the results of DaTSCAN imaging and to ascertain whether a second scan could minimize any residual diagnostic uncertainty among those with an inconclusive diagnosis. Eighty-five of 118 patients (72%) were available at follow-up. In 8 of 85 patients the neurologist was unable to provide a definite diagnosis (named as inconclusive). At follow-up, clinical diagnosis agreed with initial DaTSCAN SPECT results in 69 of 77 patients (90%) in whom a specific diagnosis was established. A second SPECT scan was performed if clinical diagnosis at follow-up differed to that suggested by the initial scan (n = 8) or was inconclusive (n = 8). Among 8 patients whose clinical diagnosis differed to DaTSCAN images, a second scan was performed in 6 (2 refused) and the results supported the final clinical diagnosis in 4. Follow-up DaTSCAN SPECT helped to establish a diagnosis in 7 of 8 patients (87.5%) with a previously inconclusive diagnosis. DaTSCAN imaging shows a high rate of agreement with clinical diagnosis after 2-years follow-up. A second scan at 2 years follow-up can reduce remaining diagnostic uncertainty that is present even after a prolonged period of observation.


Asunto(s)
Nortropanos , Trastornos Parkinsonianos/diagnóstico por imagen , Trastornos Parkinsonianos/diagnóstico , Radiofármacos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Diagnóstico Diferencial , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Trastornos Parkinsonianos/terapia , Reproducibilidad de los Resultados , Resultado del Tratamiento
15.
Eur J Nucl Med Mol Imaging ; 31(11): 1487-94, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15232656

RESUMEN

PURPOSE: Accurate diagnosis of Alzheimer's disease (AD), the most common form of dementia, remains difficult. In order to assess whether fully automated stereotactic surface projection (3D-SSP) presentation contributes to the diagnosis of AD by single-photon emission computed tomography (SPECT), we investigated the diagnostic accuracy of transaxial display with and without 3D-SSP analysis as well as the correlation between cerebral perfusion in different cortical areas and the mini mental score (MMS). METHODS: Seventy-two patients referred because of cognitive impairment were included in the study. According to the National Institute of Neurological and Communicative Disorders and Stroke (NINCDS) and the Alzheimer's disease and Related Disorders Association (ADRDA) criteria, 27 patients were diagnosed as having probable AD while 45 were classified as non-AD patients. 3D-SSP was used to quantify the regional cerebral blood flow (rCBF) acquired from SPECT imaging. RESULTS: Compared with the transaxial section presentation alone, 3D-SSP presentation improved the area under the receiver operating curve (p<0.05) as well as intra-observer (k=0.73 vs 0.88) and inter-observer (k=0.50 vs 0.84) reproducibility. Upon normalisation of regional to thalamic activity, multiple regression analysis revealed a strong correlation between the MMS and rCBF in the right parietal cortex (p=0.002). CONCLUSION: Addition of 3D-SSP to the transaxial section display of ECD-SPECT studies improves the reproducibility and the diagnostic performance in respect of AD in patients with cognitive impairment and provides a valid tool for assessment of the severity of cortical perfusion abnormalities in such patients.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/fisiopatología , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Enfermedad de Alzheimer/clasificación , Inteligencia Artificial , Velocidad del Flujo Sanguíneo , Mapeo Encefálico/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Cintigrafía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad