Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 24(Pt 6): 1113-1119, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-29091054

RESUMEN

A hard X-ray scanning microscope installed at the Hard X-ray Nanoprobe beamline of the National Synchrotron Light Source II has been designed, constructed and commissioned. The microscope relies on a compact, high stiffness, low heat dissipation approach and utilizes two types of nanofocusing optics. It is capable of imaging with ∼15 nm × 15 nm spatial resolution using multilayer Laue lenses and 25 nm × 26 nm resolution using zone plates. Fluorescence, diffraction, absorption, differential phase contrast, ptychography and tomography are available as experimental techniques. The microscope is also equipped with a temperature regulation system which allows the temperature of a sample to be varied in the range between 90 K and 1000 K. The constructed instrument is open for general users and offers its capabilities to the material science, battery research and bioscience communities.

2.
J Synchrotron Radiat ; 22(2): 336-41, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25723934

RESUMEN

Hard X-ray microscopy is a prominent tool suitable for nanoscale-resolution non-destructive imaging of various materials used in different areas of science and technology. With an ongoing effort to push the 2D/3D imaging resolution down to 10 nm in the hard X-ray regime, both the fabrication of nano-focusing optics and the stability of the microscope using those optics become extremely challenging. In this work a microscopy system designed and constructed to accommodate multilayer Laue lenses as nanofocusing optics is presented. The developed apparatus has been thoroughly characterized in terms of resolution and stability followed by imaging experiments at a synchrotron facility. Drift rates of ∼2 nm h(-1) accompanied by 13 nm × 33 nm imaging resolution at 11.8 keV are reported.

3.
Rev Sci Instrum ; 86(12): 123702, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26724037

RESUMEN

We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope's MTF, tests with the BPRML sample can be used to fine tune the instrument's focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

4.
Rev Sci Instrum ; 85(3): 033707, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24689592

RESUMEN

We have designed and constructed a dedicated instrument to perform ptychography measurements and characterization of multilayer Laue lenses nanofocusing optics. The design of the scanning microscope provides stability of components and minimal thermal drifts, requirements for nanometer scale spatial resolution measurements. We performed thorough laboratory characterization of the instrument in terms of resolution and thermal drifts with subsequent measurements at a synchrotron. We have successfully acquired and reconstructed ptychography data yielding 11 nm line focus.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA