Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Clin Oncol (R Coll Radiol) ; 20(4): 293-300, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18234482

RESUMEN

AIMS: Radical radiotherapy for stage II/III non-small cell lung cancer (NSCLC) includes the primary tumour and positive mediastinal lymph nodes in the clinical target volume (CTV). These move independently of each other in magnitude and direction during respiration. To prevent a geographical miss, a generic margin is usually added to the CTV to create an internal target volume (ITV). Previous studies have investigated the use of additional breath-hold computed tomography to generate patient-specific ITVs for primary tumours alone. We used a similar technique to investigate the generation of patient-specific and generic ITVs for CTVs that include mediastinal lymph nodes. MATERIALS AND METHODS: Thirteen patients with node-positive NSCLC had two limited end-tidal breath-hold computed tomography scans in addition to their planning computed tomography. The CTV was segmented in each scan and a rigid registration was carried out on the vertebral columns to align them. Different methods for generating an ITV were then analysed. RESULTS: Generic margins provided >95% mean coverage of the reference ITV. However, with the exception of 1cm expansion margins, there were cases of inadequate coverage (<95%) for each ITV. With increasing ITV margins there was a small increase in reference ITV coverage, but at the expense of a large increase in the volume of normal tissue within the ITV. DISCUSSION: For stage II/III NSCLC, ITV generation by the addition of a generic margin is not optimal. It can result in both geographical miss and excessive irradiation of normal tissue in the same treatment plan. A simple method for producing a patient-specific ITV is to co-register end-tidal breath-hold computed tomography scans to the planning scan. CONCLUSIONS: Further work is required to determine whether end-tidal breath-hold scans are representative of the anatomy at the limits of tidal respiration. Planning strategies are also needed to account for breathing cycle variation during a course of radiotherapy.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Planificación de la Radioterapia Asistida por Computador , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Metástasis Linfática , Masculino , Mediastino , Persona de Mediana Edad , Radiografía , Carga Tumoral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA