Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Proc Natl Acad Sci U S A ; 120(38): e2212949120, 2023 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-37695908

RESUMEN

Fluorescent reporters of cardiac electrophysiology provide valuable information on heart cell and tissue function. However, motion artifacts caused by cardiac muscle contraction interfere with accurate measurement of fluorescence signals. Although drugs such as blebbistatin can be applied to stop cardiac tissue from contracting by uncoupling calcium-contraction, their usage prevents the study of excitation-contraction coupling and, as we show, impacts cellular structure. We therefore developed a robust method to remove motion computationally from images of contracting cardiac muscle and to map fluorescent reporters of cardiac electrophysiological activity onto images of undeformed tissue. When validated on cardiomyocytes derived from human induced pluripotent stem cells (iPSCs), in both monolayers and engineered tissues, the method enabled efficient and robust reduction of motion artifact. As with pharmacologic approaches using blebbistatin for motion removal, our algorithm improved the accuracy of optical mapping, as demonstrated by spatial maps of calcium transient decay. However, unlike pharmacologic motion removal, our computational approach allowed direct analysis of calcium-contraction coupling. Results revealed calcium-contraction coupling to be more uniform across cells within engineered tissues than across cells in monolayer culture. The algorithm shows promise as a robust and accurate tool for optical mapping studies of excitation-contraction coupling in heart tissue.


Asunto(s)
Células Madre Pluripotentes Inducidas , Miocitos Cardíacos , Humanos , Artefactos , Calcio , Programas Informáticos , Calcio de la Dieta , Colorantes
2.
J Biomech Eng ; 142(7)2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-31891380

RESUMEN

Estimating strain on surfaces of deforming three-dimensional (3D) structures is a critical need in experimental mechanics. Although single-camera techniques excel at estimating deformation on a surface parallel to the imaging plane, they are prone to artifact for 3D motion because they cannot distinguish between out-of-plane motion and in-plane dilatation. Multiview (e.g., stereo) camera systems overcome this via a three-step process consisting of: (1) independent surface registration, (2) triangulation to estimate surface displacements, and (3) deformation estimation. However, existing methods are prone to errors associated with numerical differentiation when computing estimating strain fields from displacement fields unless regularization schemes are used. Such regularization schemes can introduce inaccuracy into strain estimation. Inspired by previous work which combined registration and deformation estimation into a single step for 2D images and 3D imaging stacks, we developed a theory for simultaneous image registration, 3D triangulation, and deformation estimation in a multiview system. The deformation estimation does not require numerical differentiation of displacement fields to estimate strain fields. We present here the theoretical foundations and derivation of two related implementations of this approach, and discuss their strengths and weaknesses.


Asunto(s)
Imagenología Tridimensional , Algoritmos , Fantasmas de Imagen
3.
J Biomech Eng ; 141(6)2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30840030

RESUMEN

Current in vivo abdominal aortic aneurysm (AAA) imaging approaches tend to focus on maximum diameter but do not measure three-dimensional (3D) vascular deformation or strain. Complex vessel geometries, heterogeneous wall compositions, and surrounding structures can all influence aortic strain. Improved understanding of complex aortic kinematics has the potential to increase our ability to predict aneurysm expansion and eventual rupture. Here, we describe a method that combines four-dimensional (4D) ultrasound and direct deformation estimation to compute in vivo 3D Green-Lagrange strain in murine angiotensin II-induced suprarenal dissecting aortic aneurysms, a commonly used small animal model. We compared heterogeneous patterns of the maximum, first-component 3D Green-Lagrange strain with vessel composition from mice with varying AAA morphologies. Intramural thrombus and focal breakage in the medial elastin significantly reduced aortic strain. Interestingly, a dissection that was not detected with high-frequency ultrasound also experienced reduced strain, suggesting medial elastin breakage that was later confirmed via histology. These results suggest that in vivo measurements of 3D strain can provide improved insight into aneurysm disease progression. While further work is needed with both preclinical animal models and human imaging studies, this initial murine study indicates that vessel strain should be considered when developing an improved metric for predicting aneurysm growth and rupture.

4.
J Biomech Eng ; 141(1)2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30267039

RESUMEN

Quantifying dynamic strain fields from time-resolved volumetric medical imaging and microscopy stacks is a pressing need for radiology and mechanobiology. A critical limitation of all existing techniques is regularization: because these volumetric images are inherently noisy, the current strain mapping techniques must impose either displacement regularization and smoothing that sacrifices spatial resolution, or material property assumptions that presuppose a material model, as in hyperelastic warping. Here, we present, validate, and apply the first three-dimensional (3D) method for estimating mechanical strain directly from raw 3D image stacks without either regularization or assumptions about material behavior. We apply the method to high-frequency ultrasound images of mouse hearts to diagnose myocardial infarction. We also apply the method to present the first ever in vivo quantification of elevated strain fields in the heart wall associated with the insertion of the chordae tendinae. The method shows promise for broad application to dynamic medical imaging modalities, including high-frequency ultrasound, tagged magnetic resonance imaging, and confocal fluorescence microscopy.


Asunto(s)
Corazón/diagnóstico por imagen , Imagenología Tridimensional , Animales , Corazón/fisiopatología , Masculino , Ratones , Ratones Endogámicos C57BL , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Músculos Papilares/diagnóstico por imagen , Músculos Papilares/patología , Músculos Papilares/fisiopatología , Ultrasonografía
5.
Acta Biomater ; 58: 492-501, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28532898

RESUMEN

Partially mineralized fibrous tissue situated between tendon and bone is believed to be tougher than either tendon or bone, possibly serving as a compliant, energy absorptive, protective barrier between the two. This tissue does not reform following surgical repair (e.g., rotator cuff tendon-to-bone re-attachment) and might be a factor in the poor outcomes following such surgeries. Towards our long-term goal of tissue engineered solutions to functional tendon-to-bone re-attachment, we tested the hypotheses that partially mineralized fibrous matrices can derive toughness from mobility of mineral along their fibers, and that in such cases toughness is maximized at levels of mineralization sufficiently low to allow substantial mobility. Nanofibrous electrospun poly(lactic-co-glycolic acid) (PLGA) scaffolds mineralized for prescribed times were fabricated as model systems to test these hypotheses. Tensile tests performed at varying angles relative to the dominant fiber direction confirmed that mineral cross-linked PLGA nanofibers without adhering to them. Peel tests revealed that fracture toughness increased with mineralization time up to a peak value, then subsequently decreased with increasing mineralization time back to the baseline toughness of unmineralized scaffolds. These experimental results were predicted by a theoretical model combining mineral growth kinetics with fracture energetics, suggesting that toughness increased with mineralization time until mineral mobility was attenuated by steric hindrance, then returned to baseline levels following the rigid percolation threshold. Results supported our hypotheses, and motivate further study of the roles of mobile mineral particles in toughening the tendon-to-bone attachment. STATEMENT OF SIGNIFICANCE: Effective surgical repair of interfaces between tendon and bone remains an unmet clinical need, in part due to a lack of understanding of how toughness is achieved in the healthy tissue. Using combined synthesis, experiment, and modeling approaches, the current work supported the hypothesis that toughening of a fibrous scaffold arises from brittle mineral particles that crosslink the fibers, but only if the particles are free to slide relative to the fibers. In the case of the tendon-to-bone interface, this suggests that partially mineralized tissue between tendon and bone, with mobile mineral but relatively low stiffness, may serve as a compliant, energy-absorbing barrier that guards against injury. These results suggest an opportunity for fabrication of tough and strong fibrous scaffolds for tissue engineering applications.


Asunto(s)
Ácido Láctico/química , Minerales/química , Modelos Químicos , Ácido Poliglicólico/química , Andamios del Tejido/química , Copolímero de Ácido Poliláctico-Ácido Poliglicólico
6.
Acta Biomater ; 56: 25-35, 2017 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-28088669

RESUMEN

The tendon-to-bone attachment (enthesis) is a complex hierarchical tissue that connects stiff bone to compliant tendon. The attachment site at the micrometer scale exhibits gradients in mineral content and collagen orientation, which likely act to minimize stress concentrations. The physiological micromechanics of the attachment thus define resultant performance, but difficulties in sample preparation and mechanical testing at this scale have restricted understanding of structure-mechanical function. Here, microscale beams from entheses of wild type mice and mice with mineral defects were prepared using cryo-focused ion beam milling and pulled to failure using a modified atomic force microscopy system. Micromechanical behavior of tendon-to-bone structures, including elastic modulus, strength, resilience, and toughness, were obtained. Results demonstrated considerably higher mechanical performance at the micrometer length scale compared to the millimeter tissue length scale, describing enthesis material properties without the influence of higher order structural effects such as defects. Micromechanical investigation revealed a decrease in strength in entheses with mineral defects. To further examine structure-mechanical function relationships, local deformation behavior along the tendon-to-bone attachment was determined using local image correlation. A high compliance zone near the mineralized gradient of the attachment was clearly identified and highlighted the lack of correlation between mineral distribution and strain on the low-mineral end of the attachment. This compliant region is proposed to act as an energy absorbing component, limiting catastrophic failure within the tendon-to-bone attachment through higher local deformation. This understanding of tendon-to-bone micromechanics demonstrates the critical role of micrometer scale features in the mechanics of the tissue. STATEMENT OF SIGNIFICANCE: The tendon-to-bone attachment (enthesis) is a complex hierarchical tissue with features at a numerous scales that dissipate stress concentrations between compliant tendon and stiff bone. At the micrometer scale, the enthesis exhibits gradients in collagen and mineral composition and organization. However, the physiological mechanics of the enthesis at this scale remained unknown due to difficulty in preparing and testing micrometer scale samples. This study is the first to measure the tensile mechanical properties of the enthesis at the micrometer scale. Results demonstrated considerably enhanced mechanical performance at the micrometer length scale compared to the millimeter tissue length scale and identified a high-compliance zone near the mineralized gradient of the attachment. This understanding of tendon-to-bone micromechanics demonstrates the critical role of micrometer scale features in the mechanics of the tissue.


Asunto(s)
Densidad Ósea , Módulo de Elasticidad , Cabeza Humeral/química , Tendones/química , Animales , Femenino , Ratones
7.
Interface Focus ; 6(1): 20150070, 2016 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-26855755

RESUMEN

Functionally graded, mineralized collagen tissues exist at soft-to-hard material attachments throughout the body. However, the details of how collagen and hydroxyapatite mineral (HA) interact are not fully understood, hampering efforts to develop tissue-engineered constructs that can assist with repair of injuries at the attachments of soft tissues to bone. In this study, spatial control of mineralization was achieved in collagen matrices using simulated body fluids (SBFs). Based upon previous observations of poor bonding between reconstituted collagen and HA deposited using SBF, we hypothesized that mineralizing collagen in the presence of fetuin (which inhibits surface mineralization) would lead to more mineral deposition within the scaffold and therefore a greater increase in stiffness and toughness compared with collagen mineralized without fetuin. We tested this hypothesis through integrated synthesis, mechanical testing and modelling of graded, mineralized reconstituted collagen constructs. Results supported the hypothesis, and further suggested that mineralization on the interior of reconstituted collagen constructs, as promoted by fetuin, led to superior bonding between HA and collagen. The results provide us guidance for the development of mineralized collagen scaffolds, with implications for bone and tendon-to-bone tissue engineering.

8.
J R Soc Interface ; 11(100): 20140685, 2014 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-25165601

RESUMEN

When mechanical factors underlie growth, development, disease or healing, they often function through local regions of tissue where deformation is highly concentrated. Current optical techniques to estimate deformation can lack precision and accuracy in such regions due to challenges in distinguishing a region of concentrated deformation from an error in displacement tracking. Here, we present a simple and general technique for improving the accuracy and precision of strain estimation and an associated technique for distinguishing a concentrated deformation from a tracking error. The strain estimation technique improves accuracy relative to other state-of-the-art algorithms by directly estimating strain fields without first estimating displacements, resulting in a very simple method and low computational cost. The technique for identifying local elevation of strain enables for the first time the successful identification of the onset and consequences of local strain concentrating features such as cracks and tears in a highly strained tissue. We apply these new techniques to demonstrate a novel hypothesis in prenatal wound healing. More generally, the analytical methods we have developed provide a simple tool for quantifying the appearance and magnitude of localized deformation from a series of digital images across a broad range of disciplines.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Modelos Biológicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA