Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 102(6): 1140-1148, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37668110

RESUMEN

BACKGROUND: Preprocedural computed tomography planning improves procedural safety and efficacy of transcatheter aortic valve implantation (TAVI). However, contemporary imaging modalities do not account for device-host interactions. AIMS: This study evaluates the value of preprocedural computer simulation with FEops HEARTguideTM on overall device success in patients with challenging anatomies undergoing TAVI with a contemporary self-expanding supra-annular transcatheter heart valve. METHODS: This prospective multicenter observational study included patients with a challenging anatomy defined as bicuspid aortic valve, small annulus or severely calcified aortic valve. We compared the heart team's transcatheter heart valve (THV) planning decision based on (1) conventional multislice computed tomography (MSCT) and (2) MSCT imaging with FEops HEARTguideTM simulations. Clinical outcomes and THV performance were followed up to 30 days. RESULTS: A total of 77 patients were included (median age 79.9 years (IQR 74.2-83.8), 42% male). In 35% of the patients, preprocedural planning changed after FEops HEARTguideTM simulations (change in valve size selection [12%] or target implantation height [23%]). A new permanent pacemaker implantation (PPI) was implanted in 13% and >trace paravalvular leakage (PVL) occurred in 28.5%. The contact pressure index (i.e., simulation output indicating the risk of conduction abnormalities) was significantly higher in patients with a new PPI, compared to those without (16.0% [25th-75th percentile 12.0-21.0] vs. 3.5% [25th-75th percentile 0-11.3], p < 0.01) The predicted PVL was 5.7 mL/s (25th-75th percentile 1.3-11.1) in patients with none-trace PVL, 12.7 (25th-75th percentile 5.5-19.1) in mild PVL and 17.7 (25th-75th percentile 3.6-19.4) in moderate PVL (p = 0.04). CONCLUSION: FEops HEARTguideTM simulations may provide enhanced insights in the risk for PVL or PPI after TAVI with a self-expanding supra-annular THV in complex anatomies.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Simulación por Computador , Estudios Prospectivos , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Tomografía Computarizada Multidetector/métodos , Diseño de Prótesis
2.
Catheter Cardiovasc Interv ; 101(5): 932-942, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36924015

RESUMEN

BACKGROUND: With expansion of transcatheter aortic valve implantation (TAVI) into younger patients, valve durability is critically important. AIMS: We aimed to evaluate long-term valve function and incidence of severe structural valve deterioration (SVD) among patients ≥ 10-years post-TAVI and with echocardiographic follow-up at least 5-years postprocedure. METHODS: Data on patients who underwent TAVI from 2007 to 2011 were obtained from the UK TAVI registry. Patients with paired echocardiograms postprocedure and ≥5-years post-TAVI were included. Severe SVD was determined according to European task force guidelines. RESULTS: 221 patients (79.4 ± 7.3 years; 53% male) were included with median echocardiographic follow-up 7.0 years (range 5-13 years). Follow-up exceeded 10 years in 43 patients (19.5%). Valve types were the supra-annular self-expanding CoreValve (SEV; n = 143, 67%), balloon-expandable SAPIEN/XT (BEV; n = 67, 31%), Portico (n = 4, 5%) and unknown (n = 7, 3%). There was no difference between postprocedure and follow-up peak gradient in the overall cohort (19.3 vs. 18.4 mmHg; p = NS) or in those with ≥10-years follow-up (21.1 vs. 21.1 mmHg; p = NS). Severe SVD occurred in 13 patients (5.9%; median 7.8-years post-TAVI). Three cases (23.1%) were due to regurgitation and 10 (76.9%) to stenosis. Valve-related reintervention/death occurred in 5 patients (2.3%). Severe SVD was more frequent with BEV than SEV (11.9% vs. 3.5%; p = 0.02), driven by a difference in patients treated with small valves (BEV 28.6% vs. SEV 3.0%; p < 0.01). CONCLUSIONS: Hemodynamic function of transcatheter heart valves remains stable up to more than 10 years post-TAVI. Severe SVD occurred in 5.9%, and valve-related death/reintervention in 2.3%. Severe SVD was more common with BEV than SEV.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros , Reino Unido , Diseño de Prótesis
3.
Catheter Cardiovasc Interv ; 97(4): E552-E559, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32779877

RESUMEN

OBJECTIVES: We sought to identify baseline demographics and procedural factors that might independently predict in-hospital stroke following transcatheter aortic valve implantation (TAVI). BACKGROUND: Stroke is a recognized, albeit infrequent, complication of TAVI. Established predictors of procedure-related in-hospital stroke; however, remain poorly defined. METHODS: We conducted an observational cohort analysis of the multicenter UK TAVI registry. The primary outcome measure was the incidence of in-hospital stroke. RESULTS: A total of 8,652 TAVI procedures were performed from 2007 to 2015. There were 205 in-hospital strokes reported by participating centers equivalent to an overall stroke incidence of 2.4%. Univariate analysis showed that the implantation of balloon-expandable valves caused significantly fewer strokes (balloon-expandable 96/4,613 [2.08%] vs. self-expandable 95/3,272 [2.90%]; p = .020). After multivariable analysis, prior cerebrovascular disease (CVD) (odds ratio [OR] 1.51, 95% confidence interval [CI 1.05-2.17]; p = .03), advanced age at time of operation (OR 1.02 [0.10-1.04]; p = .05), bailout coronary stenting (OR 5.94 [2.03-17.39]; p = .008), and earlier year of procedure (OR 0.93 [0.87-1.00]; p = .04) were associated with an increased in-hospital stroke risk. There was a reduced stroke risk in those who had prior cardiac surgery (OR 0.62 [0.41-0.93]; p = .01) and a first-generation balloon-expandable valve implanted (OR 0.72 [0.53-0.97]; p = .03). In-hospital stroke significantly increased 30-day (OR 5.22 [3.49-7.81]; p < .001) and 1-year mortality (OR 3.21 [2.15-4.78]; p < .001). CONCLUSIONS: In-hospital stroke after TAVI is associated with substantially increased early and late mortality. Factors independently associated with in-hospital stroke were previous CVD, advanced age, no prior cardiac surgery, and deployment of a predominantly first-generation self-expandable transcatheter heart valve.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes , Hospitales , Humanos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Reino Unido/epidemiología
4.
Catheter Cardiovasc Interv ; 98(3): E444-E452, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33502784

RESUMEN

OBJECTIVES: To determine whether a permanent pacemaker (PPM) in situ can enhance survival after transcatheter aortic valve implantation (TAVI), in a predominantly inoperable or high risk cohort. BACKGROUND: New conduction disturbances are the most frequent complication of TAVI, often necessitating PPM implantation before hospital discharge. METHODS: We performed an observational cohort analysis of the UK TAVI registry (2007-2015). Primary and secondary endpoints were 30-day post-discharge all-cause mortality and long-term survival, respectively. RESULTS: Of 8,651 procedures, 6,815 complete datasets were analyzed. A PPM at hospital discharge, irrespective of when implantation occurred (PPM 1.68% [22/1309] vs. no PPM 1.47% [81/5506], odds ratio [OR] 1.14, 95% confidence interval [CI] 0.71-1.84; p = .58), or a PPM implanted peri- or post-TAVI only (PPM 1.44% [11/763] vs. no PPM 1.47% [81/5506], OR 0.98 [0.51-1.85]; p = .95) did not significantly reduce the primary endpoint. Patients with a PPM at discharge were older, male, had right bundle branch block at baseline, were more likely to have received a first-generation self-expandable prosthesis and had experienced more peri- and post-procedural complications including bailout valve-in-valve rescue, bleeding and acute kidney injury. A Cox proportional hazards model demonstrated significantly reduced long-term survival in all those with a PPM, irrespective of implantation timing (hazard ratio [HR] 1.14 [1.02-1.26]; p = .019) and those receiving a PPM only at the time of TAVI (HR 1.15 [1.02-1.31]; p = .032). The reasons underlying this observation warrant further investigation. CONCLUSIONS: A PPM did not confer a survival advantage in the first 30 days after hospital discharge following TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Cuidados Posteriores , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Masculino , Alta del Paciente , Complicaciones Posoperatorias , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32592401

RESUMEN

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 96(1): 158-166, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31566902

RESUMEN

OBJECTIVES: We wished to undertake a reconstructed individual patient data meta-analysis of randomized clinical trials comparing transcatheter aortic valve replacement (TAVR) and surgery for patients with severe symptomatic aortic stenosis. BACKGROUND: TAVR and surgery are both well-established methods for treating patients with symptomatic severe aortic stenosis who are at low, intermediate, and high risk for surgery. METHODS: Data were identified by searches of Medline, Embase, CENTRAL and ClinicalTrials.gov for all randomized clinical trials, which compared TAVR and surgery that had published at least 1 year of follow-up. Individual patient data were reconstructed from Kaplan-Meier curves. RESULTS: A total of 7,770 patients from seven randomized clinical trials were included in this meta-analysis. At 1 year, TAVR was associated with a lower risk of death from any cause (hazard ratio [HR], 0.85, 95% confidence interval [CI], 0.73-0.98; p = .03), disabling stroke (HR, 0.71; 95% CI, 0.54-0.93; p = .01) and the composite end point of death or disabling stroke (HR, 0.79; 95% CI, 0.67-0.92; p = .002). Significant interactions were found for access suitability, with TAVR associated with a lower risk of these end points in patients suitable for transfemoral access. TAVR was associated with a lower risk of periprocedural events, whereas the risk of late events was similar between TAVR and surgery. CONCLUSIONS: At 1 year, TAVR was associated with a lower risk of death, disabling stroke and the composite end point, when compared with surgery. These associations were strongest within the subgroup of patients in whom transfemoral access was feasible.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 95(7): 1340-1346, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-31713325

RESUMEN

OBJECTIVES: The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves. BACKGROUND: The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation. METHODS: Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2 (VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all-cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%. CONCLUSIONS: Real-world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Pericardio/trasplante , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Irlanda , Masculino , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Reino Unido
8.
Heart Lung Circ ; 29(6): 904-913, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31182269

RESUMEN

AIM: Psoas muscle cross-sectional area (CSA) is a proposed marker of frailty associated with mortality after transcatheter aortic valve implantation (TAVI). We assessed the impact of psoas CSA on medium-term mortality over 5 years in a large cohort, adjusted for pre-procedural variables. METHOD: This single-centre registry-derived analysis assessed 1,731 consecutive TAVI patients between 2007 and 31 April 2015 with available abdominal computed tomography scans. Sex-stratified, height-adjusted psoas CSA was measured mid-body of the fourth lumbar vertebra. Kaplan-Meier survival distributions across psoas CSA quartiles were compared. Cox and logistic regression models were used to assess baseline variables associated with the primary outcome, which was mortality within 5 years. RESULTS: Median age was 81 years (interquartile range, 77 - 85); 52.5% were women. The primary endpoint occurred in 555 patients over a mean follow-up of 775 days. Lower psoas CSA quartile patients were older, had a lower body mass index, lower creatinine clearance, and lower rates of previous cardiac surgery, with higher rates of diabetes, coronary artery disease, pacemaker, anaemia, hypoalbuminaemia, and higher European System for Cardiac Operative Risk Evaluation (EuroSCORE). Unadjusted survival by psoas CSA quartile was significantly different in men (log rank p=0.041) but not women (p=0.099). In Bonferroni-adjusted multivariate analysis, psoas CSA quartiles were not significantly associated with mortality. Hypoalbuminaemia (hazard ratio [HR], 2.10; 95% confidence interval [CI], 1.53 - 2.87 [p<0.001]) and increasing age (HR, 1.03 per year; 95% CI, 1.01 - 1.05 [p=0.002]) were associated with increased risk; female sex (HR, 0.63; 95% CI 0.51 - 0.78 [p<0.001]), and hypercholesterolaemia (HR, 0.67; 95%, CI 0.54 0.83 [p<0.001]) with reduced risk. CONCLUSIONS: Psoas CSA was not significantly associated with mortality after adjusting for pre-procedural variables. Hypoalbuminaemia, sex, hypercholesterolaemia, and age were significantly associated with mortality after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Músculos Psoas/diagnóstico por imagen , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Masculino , Músculos Psoas/cirugía , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30394657

RESUMEN

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Irlanda , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Reino Unido
10.
Eur Heart J ; 38(36): 2729-2738, 2017 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-28633375

RESUMEN

AIMS: The ADVANCE study was designed to evaluate the safety and effectiveness of transcatheter aortic valve implantation (TAVI) with a self-expanding bioprosthesis in real-world patients with symptomatic, severe aortic stenosis at high surgical risk for valve replacement. METHODS AND RESULTS: Study participants were enrolled from 44 experienced centres in 12 countries. Patient eligibility, treatment approach, and choice of anaesthesia were determined by the local Heart Team. The study was 100% monitored, and adverse events were adjudicated by an independent clinical events committee using Valve Academic Research Consortium (VARC-1) criteria. There were 1015 patients enrolled with 996 attempted TAVI procedures. Mean age was 81 years, and mean logistic EuroSCORE was 19.3 ± 12.3%. Five-year follow-up was available on 465 (46.7%) patients. At 5 years, the rate of all-cause mortality was 50.7% (95% confidence interval: 46.7%, 54.5%), and the rate of major stroke was 5.4%. Haemodynamic measures remained consistent for paired patients with a mean aortic valve gradient of 8.8 ± 4.4 mmHg (n = 198) and an effective orifice area of 1.7 ± 0.4 cm2 (n = 123). Aortic regurgitation (AR) decreased over time and among paired patients dropped from 12.8% to 8.0% moderate AR at 5 years (n = 125). Of the 860 patients with echocardiographic data or a reintervention after 30 days, there were 22 (2.6%) patients meeting the VARC-2 criteria for valve dysfunction and 10 (1.2%) patients with a reintervention >30 days. CONCLUSION: Five-year results in real-world, elderly, high-risk patients undergoing TAVI with a self-expanding bioprosthesis provided evidence for continued valve durability with low rates of reinterventions and haemodynamic valve dysfunction. TRIAL REGISTRATION: ClinicalTrials.gov, NCT01074658.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Válvula Aórtica , Estenosis de la Válvula Aórtica/mortalidad , Ecocardiografía , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Estudios Prospectivos , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
11.
Eur Heart J ; 35(38): 2672-84, 2014 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-24682842

RESUMEN

AIM: Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre 'real-world' patient population in highly experienced centres. METHODS AND RESULTS: Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. CONCLUSION: The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/mortalidad , Causas de Muerte , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
13.
Br J Neurosurg ; 28(3): 421-2, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24304266

RESUMEN

Previously, patent foramen ovale (PFO) was an absolute contraindication to surgery in the sitting position. We report two patients with PFO who underwent surgery in the sitting position after percutaneous PFO closure. To our knowledge this is the first report of this technique.


Asunto(s)
Foramen Oval Permeable/cirugía , Procedimientos Neuroquirúrgicos/métodos , Posicionamiento del Paciente , Cuidados Preoperatorios , Adulto , Neoplasias Encefálicas/cirugía , Neoplasias del Oído/cirugía , Embolia Aérea/prevención & control , Femenino , Humanos , Masculino , Meningioma/cirugía , Persona de Mediana Edad , Neuroma Acústico/cirugía
14.
JAMA ; 312(2): 162-70, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25005653

RESUMEN

IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Análisis de Supervivencia , Resultado del Tratamiento
15.
Circulation ; 126(19): 2335-44, 2012 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-23052028

RESUMEN

BACKGROUND: Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS: The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS: The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Falla de Equipo/estadística & datos numéricos , Salud Global/estadística & datos numéricos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Sistema de Registros , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Incidencia , Masculino , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 81(2): 366-73, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22730270

RESUMEN

OBJECTIVES: We sought to characterize UK-wide balloon aortic valvuloplasty (BAV) experience in the TAVI era. BACKGROUND: BAV for acquired calcific aortic stenosis is in a phase of renaissance, largely due to the development of transcatheter aortic valve implantation (TAVI). METHODS: Data from 423 patients at 14 centers across the UK were analyzed. RESULTS: Patients were aged 80.9 ± 9.5 years; 52.5% were male. Mean logistic EuroScore was 27.3% ± 16.8%. Mean peak transaortic gradient fell from 62.0 ± 26.3 to 28.3 ± 16.2 mm Hg. Aortic valve area increased from 0.58 ± 0.19 to 0.80 ± 0.25 cm(2) echocardiographically. Procedural complication rate was 6.3%, comprising death (2.4%), blood transfusion ≥ 2 U (1.2%), cardiac tamponade (1.0%), stroke (1.0%), vascular surgical repair (1.0%), coronary embolism (0.5%), and permanent pacemaker (0.2%). Mortality was 13.8% at 30 days and 36.3% at 12 months. Subsequently, 18.3% of patients underwent TAVI and 7.0% sAVR, with improved survival compared to those who had no further intervention (logrank < 0.0001). Multivariate Cox proportional hazard analysis demonstrated that survival was adversely effected by the presence of coronary artery disease (HR 1.53, 95%CI 1.08-2.17, P = 0.018), poor LV function (HR 1.54, 95%CI 1.09-2.16, P = 0.014), and either urgent (HR 1.70, 95%CI 1.18-2.45; P = 0.004) or emergent presentation (HR 3.72, 95%CI 2.27-6.08; P < 0.0001). CONCLUSION: Balloon aortic valvuloplasty offers good immediate hemodynamic efficacy at an acceptable risk of major complications. Medium-term prognosis is poor in the absence of definitive therapy.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Valvuloplastia con Balón , Calcinosis/terapia , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/patología , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Calcinosis/diagnóstico , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Reino Unido
17.
J Heart Valve Dis ; 22(2): 204-8, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23798209

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Surgical aortic valve replacement remains the 'gold standard' treatment for aortic valve disease. An increasing number of elderly patients with multiple comorbidities are referred for transcatheter aortic valve implantation (TAVI), partly due to the perceived high risks of surgery. These include in particular patients who have had previous cardiac surgery. The study aim was to compare the outcomes of patients with aortic valve disease and previous cardiac surgery who underwent TAVI, with those who had redo surgery. METHODS: Patients were identified with aortic valve disease and previous cardiac surgery referred to the authors' multidisciplinary meeting. Patient characteristics were noted, together with their allocation to either re-do surgery or TAVI. A total of 20 patients who had undergone previous cardiac surgery was allocated to TAVI; these were matched to 20 patients who had undergone previous surgery and subsequently had redo surgery. Treatment modalities were chosen for individual patients according to their EuroSCORE, together with other factors not accounted for in traditional scoring systems. RESULTS: Between June 2008 and March 2010, a total of 191 patients was discussed; of these patients, 63 underwent TAVI, 20 of whom had undergone previous cardiac surgery. There was no significant difference in the EuroSCORE between groups (18 +/- 2 versus 19 +/- 3.0, p = 0.91). TAVI patients had a higher body mass index (27.1 +/- 3.9 versus 21.8 +/- 0.5 kg/m2, p = 0.0001). There were no deaths at 30 days in either group. One patient (5%) in the TAVI group had a transient ischemic attack following the procedure, and one (5%) had a hematoma at the site of arterial puncture. There were more pacemaker implantations in the TAVI group than in the redo group (25% versus 0%, p = 0.02). CONCLUSION: Improved risk stratification and its understanding in patients with aortic valve disease and previous cardiac surgery is required. Despite the perceived high risks in the surgically treated group, there were no deaths and redo surgery patients had lower rates of stroke and pacemaker implantation than did those who underwent TAVI.


Asunto(s)
Cateterismo Cardíaco/métodos , Cardiopatías Congénitas/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Humanos , Masculino , Resultado del Tratamiento
18.
Cardiol Young ; 23(1): 68-74, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22583564

RESUMEN

In order to optimise care of the adult patients with complex congenital heart disease, there is a need to develop recommendations for interventions. This document is the work of representatives of the three relevant societies and provides recommendations for institutions and operators performing cardiac interventions in these patients.


Asunto(s)
Cardiología/métodos , Cardiopatías Congénitas/terapia , Adolescente , Adulto , Cardiología/educación , Cardiología/normas , Competencia Clínica , Humanos , Reino Unido , Adulto Joven
19.
Cardiovasc Revasc Med ; 51: 31-37, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36740551

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat younger, lower-risk patients with bicuspid aortic valve (BAV). Patient-specific computer simulation may identify patients at risk for developing paravalvular regurgitation (PVR) and major conduction disturbance. Only limited prospective experience of this technology exist. We wished to describe our ongoing experience with patient-specific computer simulation. METHODS: Patients who were referred for consideration of TAVR with a self-expanding transcatheter heart valve (THV) and had BAV identified on pre-procedural cardiac computed tomography imaging underwent patient-specific computer simulation. The computer simulations were reviewed by the Heart Team and used to guide surgical or transcatheter treatment approaches and to aid in THV sizing and positioning. Clinical outcomes were recorded. RESULTS: Between May 2019 and May 2021, 16 patients with BAV were referred for consideration of TAVR with a self-expanding THV. Sievers Type 1 morphology was present in 15 patients and Type 0 in the remaining patient. Two patients were predicted to develop moderate-to-severe PVR with a TAVR procedure and these patients underwent successful surgical aortic valve replacement. In the remaining 14 patients, computer simulation was used to optimize THV sizing and positioning to minimise PVR and conduction disturbance. One patient with a low valve implantation depth developed moderate PVR and this complication was correctly predicted by the computer simulations. No patient required insertion of a new permanent pacemaker. CONCLUSION: Patient-specific computer simulation may be used to guide the most appropriate treatment modality for patients with BAV. The usage of computer simulation to guide THV sizing and positioning was associated with favourable clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Enfermedad de la Válvula Aórtica Bicúspide/etiología , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Simulación por Computador , Estudios Prospectivos , Tomografía Computarizada Multidetector , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA