Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Chemistry ; : e202401752, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38900538

RESUMEN

Choline chloride (ChCl) based binary and ternary deep eutectic solvents (DES) were evaluated for methylene green electropolymerization with oxalic acid (OA) and ethylene glycol (EG) as hydrogen bond donors. Binary DES ChCl:OA in molar ratios 1:1 and 2:1 and ChCl:EG 1:2 and ternary DES (tDES) in different molar ratios and percentages of water were evaluated. The highest polymer growth was in ChCl:OA:EG-tDES with added water, that had a lower viscosity and higher ionic conductivity when associated with HCl as dopant. This enhanced the formation of more cation radicals and, consequently, more polymer formation. The PMG/MWCNT/GCE-tDES sensor was successfully applied to the simultaneous determination of 5-aminosalicylic acid (5-ASA) and acetaminophen (APAP) by differential pulse voltammetry in the concentration range 2 µM - 200 µM, with detection limits of 0.37 µM and 0.49 µM for 5-ASA and APAP, respectively. The sensor demonstrated good repeatability, reproducibility and stability, and was successfully applied in pharmaceutical formulations.

2.
Chemistry ; 29(53): e202301442, 2023 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-37606898

RESUMEN

A new fluorinated manganese porphyrin, (Mn-TPP-p-CF3 ) is reported capable of providing, based on the Mn(III)/Mn(II) equilibrium, dual 1 H relaxivity and 19 F NMR response to redox changes. The physical-chemical characterization of both redox states in DMSO-d6 /H2 O evidenced that the 1 H relaxometric and 19 F NMR properties are appropriate for differential redox MRI detection. The Mn(III)-F distance (dMn-F =9.7-10 Å), as assessed by DFT calculations, is well tailored to allow for adequate paramagnetic effect of Mn(III) on 19 F T1 and T2 relaxation times. Mn-TPP-p-CF3 has a reversible Mn(II)/Mn(III) redox potential of 0.574 V vs. NHE in deoxygenated aqueous HEPES/ THF solution. The reduction of Mn(III)-TPP-p-CF3 in the presence of ascorbic acid is slowly, but fully reversed in the presence of air oxygen, as monitored by UV-Vis spectrometry and 19 F NMR. The broad 1 H and 19 F NMR signals of Mn(III)-TPP-p-CF3 disappear in the presence of 1 equivalent ascorbate replaced by a shifted and broadened 19 F NMR signal from Mn(II)-TPP-p-CF3 . Phantom 19 F MR images in DMSO show a MRI signal intensity decrease upon reduction of Mn(III)-TPP-p-CF3 , retrieved upon complete reoxidation in air within ~24 h. 1 H NMRD curves of the Mn(III)/(II)-TPP-p-CF3 chelates in mixed DMSO/water solvent have the typical shape of Mn(II)/Mn(III) porphyrins.

3.
Molecules ; 28(6)2023 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-36985781

RESUMEN

A novel amperometric sensor for the direct determination of toxic mercury ions, Hg2+, based on the organic chelator ionophore N, N di (2-hydroxy-5-[(4-nitrophenyl)diazenyl]benzaldehyde) benzene-1,2-diamine (NDBD), and multiwalled carbon nanotubes (MWCNT) immobilized on a glassy carbon electrode surface was developed. The parameters influencing sensor performance including the ionophore concentration, the applied potential, and electrolyte pH were optimized. The sensor response to Hg2+ was linear between 1-25 µM with a limit of detection of 60 nM. Interferences from other heavy metal ions were evaluated and the sensor showed excellent selectivity towards Hg2+. The method was successfully applied to the determination of mercury ions in milk and water samples.

4.
Molecules ; 27(5)2022 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-35268599

RESUMEN

Electrochemical impedance spectroscopy is finding increasing use in electrochemical sensors and biosensors, both in their characterisation, including during successive phases of sensor construction, and in application as a quantitative determination technique. Much of the published work continues to make little use of all the information that can be furnished by full physical modelling and analysis of the impedance spectra, and thus does not throw more than a superficial light on the processes occurring. Analysis is often restricted to estimating values of charge transfer resistances without interpretation and ignoring other electrical equivalent circuit components. In this article, the important basics of electrochemical impedance for electrochemical sensors and biosensors are presented, focussing on the necessary electrical circuit elements. This is followed by examples of its use in characterisation and in electroanalytical applications, at the same time demonstrating how fuller use can be made of the information obtained from complete modelling and analysis of the data in the spectra, the values of the circuit components and their physical meaning. The future outlook for electrochemical impedance in the sensing field is discussed.


Asunto(s)
Espectroscopía Dieléctrica
5.
Anal Bioanal Chem ; 413(4): 1149-1157, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33410977

RESUMEN

A new electrochemical sensor based on thionine (TH), an electroactive polymer, and CuO nanoparticle (CuONP)-modified pencil graphite electrode (PGE) has been developed. Poly(thionine) (PTH) was formed on the CuO/PGE surface by electropolymerisation in ethaline deep eutectic solvent (DES) containing acetic acid dopant to form PTHEthaline/CuO/PGE. Cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulse voltammetry were utilized to evaluate the fabrication process, electrochemical properties, and performance parameters of the modified electrodes. The analytical performance of the PTHEthaline/CuO/PGE was evaluated with respect to linear range, limit of detection, repeatability, and reproducibility for the detection of acetaminophen (APAP) by electrooxidation in the presence of ascorbic acid (AA). Analytical parameters such as pH were optimized. The combined use of PTH and CuONP led to enhanced performance towards APAP due to the large electroactive surface area and synergistic catalytic effect, with a wide linear working range and low detection limit. The reliability of the proposed sensor for the detection of APAP was successfully tested in pharmaceutical samples containing APAP and AA, with very good recoveries. Graphical abstract.


Asunto(s)
Acetaminofén/análisis , Analgésicos no Narcóticos/análisis , Ácido Ascórbico/análisis , Cobre/química , Nanoestructuras/química , Fenotiazinas/química , Técnicas Electroquímicas/métodos , Electrodos , Grafito/química , Límite de Detección , Polímeros/química
6.
Mikrochim Acta ; 188(5): 178, 2021 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-33913010

RESUMEN

In recent years, an increasing number of studies has demonstrated that redox polymers can be used in simple and effective electrochemical sensing platforms due to their fast electron transfer and electrocatalytic ability. To develop more sensitive and selective electrochemical (bio)sensors, the electrocatalytic properties of redox polymers and the electrical, mechanical, and catalytic properties of various nanomaterials are combined. This review aims to summarize and contribute to the development of (bio)sensors based on polyphenazine or polytriphenylmethane redox polymers combined with nanomaterials, including carbon-based nanomaterials, metal/metal oxide, and semiconductor nanoparticles. The synthesis, preparation, and modification of these nanocomposites is presented and the contribution of each material to the performance of (bio)sensor has been be examined. It is explained how the combined use of these redox polymers and nanomaterials as a sensing platform leads to improved analytical performance of the (bio)sensors. Finally, the analytical performance characteristics and practical applications of polyphenazine and polytriphenylmethane redox polymer/nanomaterial-based electrochemical (bio)sensors are compared and discussed.


Asunto(s)
Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Nanocompuestos/química , Fenazinas/química , Polímeros/química , Técnicas Biosensibles/instrumentación , Técnicas Electroquímicas/instrumentación , Electrodos , Humanos , Nanopartículas del Metal/química , Oxidación-Reducción
7.
Sensors (Basel) ; 21(4)2021 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-33562228

RESUMEN

A novel hybrid composite of conductive poly(methylene blue) (PMB) and carbon nanotubes (CNT) was prepared for the detection of 5-aminosalicylic acid (5-ASA). Electrosynthesis of PMB with glassy carbon electrode (GCE) or with carbon nanotube modified GCE was done in ethaline deep eutectic solvent of choline chloride mixed with ethylene glycol and a 10% v/v aqueous solution. Different sensor architectures were evaluated in a broad range of pH values in a Britton-Robinson (BR) buffer using electrochemical techniques, chronoamperometry (CA), and differential pulse voltammetry (DPV), to determine the optimum sensor configuration for 5-ASA sensing. Under optimal conditions, the best analytical performance was obtained with CNT/PMBDES/GCE in 0.04 M BR buffer pH 7.0 in the range 5-100 µM 5-ASA using the DPV method, with an excellent sensitivity of 9.84 µA cm-2 µM-1 (4.9 % RSD, n = 5) and a detection limit (LOD) (3σ/slope) of 7.7 nM, outclassing most similar sensors found in the literature. The sensitivity of the same sensor obtained in CA (1.33 µA cm-2 µM-1) under optimal conditions (pH 7.0, Eapp = +0.40 V) was lower than that obtained by DPV. Simultaneous detection of 5-ASA and its analogue, acetaminophen (APAP), was successfully realized, showing a catalytic effect towards the electro-oxidation of both analytes, lowering their oxidation overpotential, and enhancing the oxidation peak currents and peak-to-peak separation as compared with the unmodified electrode. The proposed method is simple, sensitive, easy to apply, and economical for routine analysis.

8.
Mikrochim Acta ; 187(11): 609, 2020 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-33057990

RESUMEN

Electropolymerization of thionine (TH) on multiwalled carbon nanotube (MWCNT)-modified glassy carbon electrodes (GCE) in ethaline deep eutectic solvent (DES) was carried out for the first time, to prepare poly(thionine) (PTH) films with different nanostructured morphologies. PTH films were formed on MWCNT/GCE by potential cycling electropolymerization in ethaline with the addition of different acid dopants CH3COOH, HClO4, HNO3, H2SO4 and HCl, acetic acid being the best. The electropolymerization process was monitored with an electrochemical quartz crystal microbalance. The polymerization scan rate was a key factor affecting the electrochemical and morphological properties of the PTHEthaline-CH3COOH/MWCNT/GCE; electrodeposition at 200 mV s-1 showing the best performance. The PTH/MWCNT/GCE platform was characterized using cyclic and differential pulse voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy. The analytical characteristics of the PTH films were evaluated for sensing of ascorbic acid and biosensing of uric acid. The developed sensor exhibited a low detection limit (1.1 µM), wide linear range (2.8-3010 µM) and high sensitivity (1134 µA cm-2 mM-1) for ascorbic acid. After immobilization of uricase, UOx, on PTH/MWCNT/GCE, the biosensor was successfully applied to the determination of uric acid, with fast response (˂ 7 s), good sensitivity (450 µA cm-2 mM-1, wide linear range (0.48-279 µM) and low detection limit (58.9 nM), better than in the literature and than with PTH prepared in aqueous solution. The determination of uric acid in synthetic urine samples was successfully tested and the mean analytical recovery was 100.8 ± 1.4%. This is a promising approach for the determination of uric acid in real samples. Graphical abstract.


Asunto(s)
Disolventes Eutécticos Profundos/química , Técnicas Electroquímicas/métodos , Nanotubos de Carbono/química , Polímeros/química , Ácido Acético , Ácido Ascórbico/análisis , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Colina/química , Técnicas Electroquímicas/instrumentación , Electrodos , Enzimas Inmovilizadas/química , Glicol de Etileno/química , Límite de Detección , Fenotiazinas/química , Polimerizacion , Urato Oxidasa/química , Ácido Úrico/química , Ácido Úrico/orina
9.
Anal Chem ; 89(3): 1674-1683, 2017 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-28208270

RESUMEN

Ceramic-based multisite Pt microelectrode arrays (MEAs) were characterized for their basic electrochemical characteristics and used for in vivo measurements of oxygen with high resolution in the brain extracellular space. The microelectrode array sites showed a very smooth surface mainly composed of thin-film polycrystalline Pt, with some apparent nanoscale roughness that was not translated into an increased electrochemical active surface area. The electrochemical cyclic voltammetric behavior was characteristic of bulk Pt in both acidic and neutral media. In addition, complex plane impedance spectra showed the required low impedance (0.22 MΩ; 10.8 Ω cm2) at 1 kHz and very smooth electrode surfaces. The oxygen reduction reaction on the Pt surface proceeds as a single 4-electron reduction pathway at -0.6 V vs Ag/AgCl reference electrode. Cyclic voltammetry and amperometry demonstrate excellent electrocatalytic activity toward oxygen reduction in addition to a high sensitivity (-0.16 ± 0.02 nA µM-1) and a low limit of detection (0.33 ± 0.20 µM). Thus, these Pt MEAs provide an excellent microelectrode platform for multisite O2 recording in vivo in the extracellular space of the brain, demonstrated in anaesthetized rats, and hold promise for future in vivo studies in animal models of CNS disease and dysfunction.


Asunto(s)
Encéfalo/metabolismo , Cerámica/química , Espectroscopía Dieléctrica , Oxígeno/análisis , Platino (Metal)/química , Animales , Catálisis , Electrólitos/química , Masculino , Microelectrodos , Oxígeno/química , Ratas , Ratas Wistar
10.
Artículo en Inglés | MEDLINE | ID: mdl-27925508

RESUMEN

A simple and expedite electrochemical methodology was developed for the determination of ciprofloxacin, based on a glassy carbon (GC) electrode modified by a combination of multi-walled carbon nanotubes (MWCNT) with ß-cyclodextrin (ß-CD) incorporated in a polyaniline film. The combined use of ß-CD and MWCNT in the electrochemical sensor leads to a significant signal improvement. The ß-CD/MWCNT modified GC electrode exhibited efficient electrocatalytic behavior in the oxidation of ciprofloxacin with relatively high sensitivity, stability and lifetime. Molecular modeling studies showed that ciprofloxacin binds preferably to ß-CD rather than to CNT edges, leading to an improved sensitivity of the sensor. Under optimized conditions, a linear calibration curve was obtained for ciprofloxacin in the concentration range 10-80 µM with a detection limit of 50 nM. The analytical performance of this sensor was evaluated for the detection of ciprofloxacin in a wastewater treatment plant effluent.


Asunto(s)
Ciprofloxacina/análisis , Monitoreo del Ambiente/instrumentación , Nanotubos de Carbono/química , Aguas del Alcantarillado/química , Contaminantes Químicos del Agua/análisis , Portugal
11.
Chemistry ; 20(18): 5346-57, 2014 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-24644142

RESUMEN

Progress in the photodynamic therapy (PDT) of cancer should benefit from a rationale to predict the most efficient of a series of photosensitizers that strongly absorb light in the phototherapeutic window (650-800 nm) and efficiently generate reactive oxygen species (ROS = singlet oxygen and oxygen-centered radicals). We show that the ratios between the triplet photosensitizer-O2 interaction rate constant (kD) and the photosensitizer decomposition rate constant (kd), kD/kd, determine the relative photodynamic activities of photosensitizers against various cancer cells. The same efficacy trend is observed in vivo with DBA/2 mice bearing S91 melanoma tumors. The PDT efficacy intimately depends on the dynamics of photosensitizer-oxygen interactions: charge transfer to molecular oxygen with generation of both singlet oxygen and superoxide ion (high kD) must be tempered by photostability (low kd). These properties depend on the oxidation potential of the photosensitizer and are suitably combined in a new fluorinated sulfonamide bacteriochlorin, motivated by the rationale.


Asunto(s)
Melanoma/tratamiento farmacológico , Fármacos Fotosensibilizantes/química , Fármacos Fotosensibilizantes/uso terapéutico , Porfirinas/química , Porfirinas/uso terapéutico , Animales , Línea Celular Tumoral , Estabilidad de Medicamentos , Halogenación , Humanos , Ratones , Ratones Endogámicos DBA , Fotoquimioterapia , Fotólisis , Fármacos Fotosensibilizantes/farmacocinética , Porfirinas/farmacocinética , Oxígeno Singlete/química
12.
Anal Bioanal Chem ; 405(11): 3813-22, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23263517

RESUMEN

A new and simple-to-prepare hypoxanthine biosensor has been developed using xanthine oxidase (XOD) immobilised on carbon electrode surfaces. XOD was immobilised by glutaraldehyde cross-linking on carbon film (CF) electrodes and on carbon nanotube (CNT) modified CF (CNT/CF). A comparison of the performance of the two configurations was carried out by the current response using amperometry at fixed potential; the best characteristics being exhibited by XOD/CNT/CF modified electrodes. The effects of electrolyte pH and applied potential were evaluated, and a proposal is made for the enzyme mechanism of action involving competition between regeneration of flavin adenine dinucleotide and reduction of hydrogen peroxide. Under optimised conditions, the determination of hypoxanthine was carried out at -0.2 V vs. a saturated calomel electrode (SCE) with a detection limit of 0.75 µM on electrodes with CNT and at -0.3 V vs. SCE with a detection limit of 0.77 µM on electrodes without CNT. The applicability of the biosensor was verified by performing an interference study, reproducibility and stability were investigated, and hypoxanthine was successfully determined in sardine and shrimp samples.


Asunto(s)
Técnicas Biosensibles/instrumentación , Productos Lácteos Cultivados/enzimología , Enzimas Inmovilizadas/química , Hipoxantina/análisis , Nanotubos de Carbono/química , Xantina Oxidasa/química , Carbono/química , Electrodos , Límite de Detección , Modelos Moleculares
13.
Biosens Bioelectron ; 199: 113874, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34920228

RESUMEN

Highly sensitive and selective nanostructured lactate and glucose microbiosensors for their in vivo simultaneous determination in rat brain were developed based on carbon fiber microelectrodes (CFM) modified with nanoporous gold (NPG) using the Dynamic Hydrogen Bubble Template (DHBT) method. Electrodeposition of platinum nanoparticles (PtNP) onto the NPG film enhances the sensitivity and the electrocatalytic properties towards H2O2 detection. The nanostructured microelectrode platform was modified by glucose oxidase (GOx) and lactate oxidase (LOx) enzyme immobilization. High selective measurements were achieved by covering with a perm-selective layer of electropolymerized m-phenylenediamine, deposition of a Nafion® film and by using a null sensor. The morphological characteristics and electroanalytical performance of the microbiosensors were assessed, by scanning electron microscopy and electrochemical techniques, respectively. The PtNP/NPG/CFM shows a high sensitivity to H2O2 (5.96 A M-1 cm-2) at 0.36 V vs. Ag/AgCl, with a linear range from 0.2 to 200 µM, and an LOD of 10 nM. The microbiosensors were applied to the simultaneous determination of lactate and glucose in blood serum samples. Moreover, the basal extracellular concentrations of lactate and glucose were measured in vivo in four different rat brain structures. These results support the potential of the microbiosensor to be used as a valuable tool to investigate brain neurochemicals in vivo.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Nanoporos , Animales , Encéfalo/metabolismo , Técnicas Electroquímicas , Enzimas Inmovilizadas/metabolismo , Glucosa , Glucosa Oxidasa/metabolismo , Peróxido de Hidrógeno , Lactatos , Platino (Metal) , Ratas , Suero
14.
Phys Chem Chem Phys ; 13(12): 5462-71, 2011 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-21350784

RESUMEN

The phenazine monomers neutral red (NR) and methylene blue (MB) have been electropolymerised on different quartz crystal microbalance (QCM) substrates: MB at AuQCM and nanostructured ultrathin sputtered carbon AuQCM (AuQCM/C), and NR on AuQCM and on layer-by-layer films of hyaluronic acid with myoglobin deposited on AuQCM (AuQCM-{HA/Mb}(6)). The surface of the electrode substrates was characterised by atomic force microscopy (AFM), and the frequency changes during potential cycling electropolymerisation of the monomer were monitored by the QCM. The study investigates how the monomer chemical structure together with the electrode morphology and surface structure can influence the electropolymerisation process and the electrochemical properties of the phenazine-modified electrodes. Differences between MB and NR polymerisation, as well as between the different substrates were found. The electrochemical properties of the PNR-modified electrodes were analysed by cyclic voltammetry and electrochemical impedance spectroscopy and compared with the unmodified AuQCM. The results are valuable for future applications of modified AuQCM as substrates for electroactive polymer film deposition and applications in redox-mediated electrochemical sensors and biosensors.

15.
Chem Commun (Camb) ; 57(56): 6899-6902, 2021 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-34151915

RESUMEN

Precipitation of nanocrystallites of cobalt-aluminium layered double hydroxides in a magnetic field has been studied. In a magnetic field perpendicular to the substrate, dense and homogeneous films have been obtained. Magnetic anisotropy of the crystallites is explained by deviation from the statistical cation distribution in favour of honeycomb-like coordination of cobalt.

16.
Anal Bioanal Chem ; 398(4): 1675-85, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20625885

RESUMEN

The electrochemical behaviour of glassy carbon electrodes coated with multiwalled carbon nanotubes (MWCNT) from three different sources and with different loadings has been compared, with a view to sensor applications. Additionally, poly(neutral red) (PNR) was electrosynthesised by potential cycling on bare glassy carbon and on MWCNT-modified glassy carbon electrodes, and characterised by cyclic voltammetry and scanning electron microscopy. Well-defined voltammetric responses were observed for hexacyanoferrate (II) oxidation with differences between the MWCNT types as well as from loading. The MWCNT and PNR/MWCNT-modified electrodes were applied to the oxidative determination of ascorbate, the electrocatalytic effects observed varying according to the type of nanotubes. Comparison was made with electrodes surface-modified by graphite powder. All modified electrode configurations with and without PNR were successfully employed for ascorbate oxidation at +0.05 V vs saturated calomel electrode with detection limits down to 4 µM; good operational stability and storage stability were also obtained.

17.
Talanta ; 208: 120427, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-31816744

RESUMEN

A highly sensitive glucose oxidase (GOx) electrochemical biosensor for the determination of the biotoxic trace metal ions Hg2+, Cd2+, Pb2+ and CrVI by enzyme inhibition has been developed. GOx was immobilized on a novel sensing platform consisting of poly(brilliant green) films formed by potential cycling electropolymerization in sulfuric acid doped ethaline deep eutectic solvent on multiwalled carbon nanotube modified glassy carbon electrodes. Polymer films produced in this medium presented more uniform morphology and better electrochemical sensing properties than those prepared in aqueous solution. The inhibitor concentration necessary to give 50% inhibition, I50, was used for the determination of the type of reversible inhibition, and the relationship between I50 and the inhibition constant Ki is discussed. The new biosensor was successfully used for the determination of biotoxic trace metal ions with a nanomolar limit of detection, lower than in the literature, very good repeatability, stability and selectivity, and was applied successfully to detection of the toxic trace metal species in milk samples.


Asunto(s)
Técnicas Biosensibles , Glucosa Oxidasa/antagonistas & inhibidores , Metales Pesados/análisis , Técnicas Electroquímicas , Electrodos , Glucosa Oxidasa/química , Metales Pesados/química , Nanotubos de Carbono/química , Polímeros/química , Compuestos de Amonio Cuaternario/química
18.
Anal Chem ; 81(13): 5364-72, 2009 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-19473012

RESUMEN

The effectiveness of immobilization of functionalized carbon nanotubes into chitosan using different cross-linking agents has been evaluated. The cross-linkers used were glyoxal (GO), glutaraldehyde (GA), epichlorohydrin (ECH), and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide together with N-hydroxysuccinimide (EDC-NHS), and the nanotubes were retained on graphite epoxy resin composite electrodes. The nanotube modified electrodes have been characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Using CV and EIS in the presence of potassium hexacyanoferrate(III), the electroactive area of all types of electrodes was determined and the redox process analyzed, leading to the conclusion that ECH and EDC-NHS are better for immobilization of functionalized carbon nanotubes inside the chitosan matrix. The modified electrodes were successfully applied to the determination of hydrogen peroxide by fixed potential amperometry at -0.1 V vs SCE, the highest response being exhibited when using ECH.

19.
Food Chem ; 282: 18-26, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30711102

RESUMEN

The aim of the present work was to develop an amperometric biosensor for tyramine (Tyr) measurement in food and beverages. The biosensor architecture is based on tyrosinase (Tyrase) immobilization on glassy carbon electrode modified by a nanocomposite consisting of gold nanoparticles (AuNP) synthesized by a green method and poly(8-anilino-1-naphthalene sulphonic acid) modified glassy carbon electrode. Under optimized experimental conditions for fixed potential amperometric detection, the biosensor exhibited a linear response to tyramine in the range 10-120 µM and the limit of detection was estimated to be 0.71 µM. The novel platform showed good selectivity, long-term stability, and reproducibility. The strong interaction between tyrosinase and the nanocomposite was revealed by the high value of the Michaelis-Menten constant (79.3 µM). The fabricated biosensor was successfully applied to the determination of Tyr in dairy products and fermented drinks with good recoveries, which makes it a promising biosensor for quantification of tyramine.


Asunto(s)
Bebidas/análisis , Técnicas Biosensibles/métodos , Alimentos Fermentados/análisis , Nanopartículas del Metal/química , Monofenol Monooxigenasa/metabolismo , Tiramina/análisis , Naftalenosulfonatos de Anilina/química , Carbono/química , Técnicas Electroquímicas , Electrodos , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , Oro/química , Concentración de Iones de Hidrógeno , Cinética , Límite de Detección , Monofenol Monooxigenasa/química , Polímeros/química , Reproducibilidad de los Resultados
20.
Talanta ; 195: 604-612, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-30625590

RESUMEN

A novel impedimetric sensor for the determination of tyramine (Tyr), a biogenic amine, on the surface of gold nanoparticle-poly-(8-anilino-1-napthalene sulphonic acid), AuNP-PANSA modified gold electrode (AuE) is presented for the first time. The AuNP were successfully synthesized by a green synthesis method. Their characterization and optimization were conducted using X-ray diffraction, scanning electron microscopy, transmission electron microscopy, electrochemical impedance spectroscopy and cyclic voltammetry. Under optimal conditions, the impedimetric sensor revealed a relatively broad linear range from 0.8 to 80 µM similar to more complex architectures found in the literature and the limit of detection of 0.04 µM was the lowest achieved until now. In order to test the reliability of the proposed method, real sample application studies were conducted using dairy products and fermented drinks. It was found that the sensor presented a good selectivity and recovery. Furthermore, the impedimetric sensor shows good reproducibility, stability, selectivity and very small interferences which augur well for its application in food safety control processes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA