1.
Ultrasound Obstet Gynecol ; 58(2): 293-302, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32798253

RESUMEN

OBJECTIVES: Preterm birth (PTB) accounts for two-thirds of deaths of structurally normal babies and is associated with substantial lifetime healthcare costs. Prevention of PTB remains limited by the modest accuracy of prediction methods, namely transvaginal ultrasound (TVS) cervical length (CL) measurement and quantitative cervicovaginal fetal fibronectin (FFN) estimation. We report the first substantive study detailing the predictive performance of a cervical probe device based on electrical impedance spectroscopy (EIS) for PTB - the EleCtriCaL Impedance Prediction of Preterm birth by spectroscopy of the cervix (ECCLIPPx) study. We aimed to compare the accuracy of cervical EIS-based prediction of spontaneous PTB with that of prediction using TVS-CL and FFN in asymptomatic women in the mid-trimester. METHODS: We studied asymptomatic women with a singleton pregnancy at 20-22 weeks' and 26-28 weeks' gestation. EIS was performed using a Sheffield Mark 5.0 device that makes measurements in the frequency range 76 Hz to 625 kHz using a small probe housing tetrapolar electrodes. TVS-CL and FFN were also measured. The associations of cervical EIS, TVS-CL and FFN with spontaneous delivery before 37 weeks and before 32 weeks were determined by multivariate linear and non-linear logistic regression analysis. Areas under the receiver-operating-characteristics curves (AUC) plots of sensitivity against specificity were used to compare the predictive performance of all parameters, both in isolation and in combination. RESULTS: Of the 365 asymptomatic women studied at 20-22 weeks who were not receiving treatment, 29 had spontaneous PTB, 14 had indicated PTB and 322 had term birth. At the higher frequencies assessed, cervical EIS predicted spontaneous PTB before 37 weeks with an AUC of 0.76 (95% CI, 0.71-0.81), compared with AUCs of 0.72 (95% CI, 0.66-0.76) for TVS-CL and 0.62 (95% CI, 0.56-0.72) for FFN. Combining all three assessments improved the prediction of spontaneous PTB before 37 weeks (AUC, 0.79 (95% CI, 0.74-0.83)) compared with TVS-CL and FFN alone. Incorporating a history of spontaneous PTB (defined as previous mid-trimester miscarriage or spontaneous PTB (14 to < 37 weeks)) into the cervical EIS prediction model improved the accuracy of prediction of spontaneous PTB before 37 weeks (AUC, 0.83 (95% CI, 0.78-0.87)) and before 32 weeks (AUC, 0.86 (95% CI, 0.82-0.90)). CONCLUSIONS: Mid-trimester cervical EIS assessment predicts spontaneous PTB. Larger confirmatory studies investigating its potential clinical utility and to inform effective preventive interventions are required. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Cuello del Útero/diagnóstico por imagen , Nacimiento Prematuro/prevención & control , Diagnóstico Prenatal , Adulto , Medición de Longitud Cervical , Estudios de Cohortes , Espectroscopía Dieléctrica , Femenino , Humanos , Embarazo , Estudios Prospectivos , Sensibilidad y Especificidad
2.
BJOG ; 120(4): 400-10; discussion 410-1, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23289897

RESUMEN

OBJECTIVE: To determine if electrical impedance spectroscopy (EIS) improves the diagnostic accuracy of colposcopy when used as an adjunct. DESIGN: Prospective, comparative, multi-centre clinical study. SETTING: Three colposcopy clinics: two in England and one in Ireland. POPULATION: Women referred with abnormal cytology. METHODS: In phase 1, EIS was assessed against colposcopic impression and histopathology of the biopsies taken. In phase 2, a probability index and cut-off value for the detection of high-grade cervical intraepithelial neoplasia (HG-CIN, i.e. grade CIN2+) was derived to indicate sites for biopsy. EIS data collection and analyses were performed in real time and blinded to the clinician. The phase-2 data were analysed using different cut-off values to assess performance of EIS as an adjunct. MAIN OUTCOME MEASURE: Histologically confirmed HG-CIN (CIN2+). RESULTS: A total of 474 women were recruited: 214 were eligible for analysis in phase 1, and 215 were eligible in phase 2. The average age was 33.2 years (median age 30.3 years, range 20-64 years) and 48.5% (208/429) had high-grade cytology. Using the cut-off from phase 1 the accuracy of colposcopic impression to detect HG-CIN when using EIS as an adjunct at the time of examination improved the positive predictive value (PPV) from 78.1% (95% CI 67.5-86.4) to 91.5%. Specificity was also increased from 83.5% (95% CI 75.2-89.9) to 95.4%, but sensitivity was significantly reduced from 73.6% (95% CI 63.0-82.5) to 62.1%, and the negative predictive value (NPV) was unchanged. The positive likelihood ratio for colposcopic impression alone was 4.46. This increased to 13.5 when EIS was used as an adjunct. The overall accuracy of colposcopy when used with EIS as an adjunct was assessed by varying the cut-off applied to a combined test index. Using a cut-off set to give the same sensitivity as colposcopy in phase 2, EIS increased the PPV to detect HG-CIN from 53.5% (95% CI 45.0-61.8) to 67%, and specificity increased from 38.5% (95% CI 29.4-48.3) to 65.1%. NPV was not significantly increased. Alternatively, applying a cut-off to give the same specificity as colposcopy alone increased EIS sensitivity from 88.5% (95% CI 79.9-94.4) to 96.6%, and NPV from 80.8% (95% CI 67.5-90.4) to 93.3%. PPV was not significantly increased. The receiver operator characteristic (ROC) to detect HG-CIN had an area under the curve (AUC) of 0.887 (95% CI 0.840-0.934). CONCLUSIONS: EIS used as an adjunct to colposcopy improves colposcopic performance. The addition of EIS could lead to more appropriate patient management with lower intervention rates.


Asunto(s)
Colposcopía/normas , Espectroscopía Dieléctrica/normas , Displasia del Cuello del Útero/diagnóstico , Neoplasias del Cuello Uterino/diagnóstico , Adulto , Colposcopía/instrumentación , Espectroscopía Dieléctrica/instrumentación , Detección Precoz del Cáncer/métodos , Diseño de Equipo , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Adulto Joven
3.
Horm Metab Res ; 43(2): 100-5, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21165812

RESUMEN

The adipokine adiponectin is decreased in severe obesity and is inversely associated with adipose mass. Adiponectin is associated with insulin sensitivity and cardioprotection. Obesity frequently results in the development of a "cardiometabolic syndrome" characterized by increased circulating insulin and leptin, and cardiac hypertrophy and dysfunction. This study examined if adiponectin-deficiency affects the development of metabolic and cardiac abnormalities in response to modest obesity. Mice were studied under normal conditions and with mild cardiac pressure-overload induced by abdominal aortic banding. After surgery, wild type and adiponectin-deficient mice were fed a high-fat diet for 8 weeks (45% energy from fat vs. 10%). In wild type mice the high-fat diet increased fat and whole body mass, which corresponded with elevated circulating insulin and leptin and a decrease the glucose/insulin ratio. On the other hand, in adiponectin-deficient mice the high-fat diet had less impact on body mass and no effect on fat mass, insulin, leptin, or glucose/insulin. There was modest cardiac hypertrophy with aortic banding, but no cardiac dysfunction or effects of adiponectin deficiency or diet. The results suggest that the increase in adipose mass, leptin and insulin induced by a high fat diet is dependent on adiponectin. The lack of accelerated cardiac hypertrophy and dysfunction in the adiponectin-deficient mice subjected to aortic banding and the high-fat diet suggest that adiponectin may not play a major role in protecting the heart during the early stages of diet-induced obesity.


Asunto(s)
Adiponectina/deficiencia , Enfermedades Cardiovasculares/metabolismo , Grasas de la Dieta/efectos adversos , Síndrome Metabólico/metabolismo , Obesidad/complicaciones , Tejido Adiposo/metabolismo , Animales , Presión Sanguínea , Peso Corporal , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/fisiopatología , Modelos Animales de Enfermedad , Femenino , Humanos , Insulina/metabolismo , Leptina/metabolismo , Masculino , Síndrome Metabólico/etiología , Síndrome Metabólico/fisiopatología , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Obesidad/metabolismo , Obesidad/fisiopatología
4.
J Electr Bioimpedance ; 11(1): 81-86, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33584907

RESUMEN

OBJECTIVE: Colposcopy can be used with Electrical Impedance Spectroscopy (EIS) as an adjunct, to assess the presence of High Grade Cervical Intra-epithelial Neoplasia (CIN2+). This analysis of longitudinal data has used the results from women with a negative colposcopy, in order to see if the initial (index) EIS results were able to predict the women who subsequently developed CIN2+. A further objective was to investigate what tissue structural changes might be reflected in the electrical impedance spectra. METHODS: 847 patients were referred with low grade cytologly. EIS measurements were made around the transformation zone of the cervix during colposcopy. Every EIS spectrum was matched to a template representing CIN2+ and the result was positive if the match exceeded a probability index threshold. The colposcopic impression was also recorded. All the women who developed biopsy proven CIN2+ within three years of the index colposcopy were identified. RESULTS: The median follow-up was 30.5 months. Where both CI and EIS were initially positive, there was an increased prevalence (8.13%) of CIN2+ developing as opposed to 3.45% in the remaining patients (p=0.0159). In addition, if three or more EIS spectra were positive there was a higher prevalence (9.62% as opposed to 3.56% p=0.0132) of CIN2+ at three years. The index spectra recorded from the women who developed CIN2+ showed EIS changes consistent with increases in the extracellular volume and in cell size inhomogeneity. CONCLUSION: EIS does offer prognostic information on the risk of CIN2+ developing over the three-year period following the EIS measurements. The changes in EIS spectra are consistent with an increase in cell size diversity as pre-malignancy develops. These changes may be a consequence of increased genetic diversity as neoplasia develops.

5.
J Biomed Mater Res A ; 83(2): 391-400, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17450583

RESUMEN

Polypyrrole (PPy) is a conducting polymer that may be electrochemically generated with the incorporation of any anionic species, including net-negatively charged biological molecules such as proteins and polysaccharides. In this article, dermatan and chloride-loaded PPy films were prepared on gold sputter-coated coverslips and various skin derived cells were studied on them by electrochemical impedance spectroscopy. Impedance spectra in the frequency range 1-100 kHz were either determined at specific times or impedance was monitored continuously at specific frequencies. An equivalent impedance circuit was fitted to the recorded impedance spectra to obtain parameters whose contributions could be mapped to intracellular and intercellular current pathways, and the membrane properties of cells. Results show cell-induced impedance changes were detected over PPy modified electrodes and were dependent on cell density and type, monitoring frequency, material composition, and treatment. Lower cell densities were detected on PPy when compared with bare gold. Keratinocyte confluence, as determined by impedimetric analysis, was reached more rapidly on PPy than on gold. This was consistent with previous, more cumbersome, biochemical assays. Electrical equivalent circuit analysis provided evidence that the technique may be extended to discriminate cell type because of the intracellular and intercellular resistance, and cell membrane capacitance being related to cell morphology.


Asunto(s)
Técnicas Biosensibles/métodos , Polímeros/metabolismo , Pirroles/metabolismo , Línea Celular , Impedancia Eléctrica , Oro , Humanos , Queratinocitos/citología , Queratinocitos/metabolismo , Polímeros/química , Pirroles/química , Factores de Tiempo
6.
Physiol Meas ; 27(5): S129-37, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16636404

RESUMEN

Inter-subject variability has caused the majority of previous electrical impedance tomography (EIT) techniques to focus on the derivation of relative or difference measures of in vivo tissue resistivity. Implicit in these techniques is the requirement for a reference or previously defined data set. This study assesses the accuracy and optimum electrode placement strategy for a recently developed method which estimates an absolute value of organ resistivity without recourse to a reference data set. Since this measurement of tissue resistivity is absolute, in Ohm metres, it should be possible to use EIT measurements for the objective diagnosis of lung diseases such as pulmonary oedema and emphysema. However, the stability and reproducibility of the method have not yet been investigated fully. To investigate these problems, this study used a Sheffield Mk3.5 system which was configured to operate with eight measurement electrodes. As a result of this study, the absolute resistivity measurement was found to be insensitive to the electrode level between 4 and 5 cm above the xiphoid process. The level of the electrode plane was varied between 2 cm and 7 cm above the xiphoid process. Absolute lung resistivity in 18 normal subjects (age 22.6 +/- 4.9, height 169.1 +/- 5.7 cm, weight 60.6 +/- 4.5 kg, body mass index 21.2 +/- 1.6: mean +/- standard deviation) was measured during both normal and deep breathing for 1 min. Three sets of measurements were made over a period of several days on each of nine of the normal male subjects. No significant differences in absolute lung resistivity were found, either during normal tidal breathing between the electrode levels of 4 and 5 cm (9.3 +/- 2.4 Omega m, 9.6 +/- 1.9 Omega m at 4 and 5 cm, respectively: mean +/- standard deviation) or during deep breathing between the electrode levels of 4 and 5 cm (10.9 +/- 2.9 Omega m and 11.1 +/- 2.3 Omega m, respectively: mean +/- standard deviation). However, the differences in absolute lung resistivity between normal and deep tidal breathing at the same electrode level are significant. No significant difference was found in the coefficient of variation between the electrode levels of 4 and 5 cm (9.5 +/- 3.6%, 8.5 +/- 3.2% at 4 and 5 cm, respectively: mean +/- standard deviation in individual subjects). Therefore, the electrode levels of 4 and 5 cm above the xiphoid process showed reasonable reliability in the measurement of absolute lung resistivity both among individuals and over time.


Asunto(s)
Impedancia Eléctrica , Electrodos , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/métodos , Pulmón/fisiología , Pletismografía de Impedancia/instrumentación , Tomografía/instrumentación , Adulto , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Aumento de la Imagen/métodos , Pulmón/anatomía & histología , Masculino , Pletismografía de Impedancia/métodos , Control de Calidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía/métodos
7.
Physiol Meas ; 26(2): S111-8, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15798224

RESUMEN

A phantom was constructed to simulate the electrical properties of the neck. A range of possible electrode configurations was then examined in order to improve the sensitivity of the impedance measurement method for the in vivo detection of air emboli. The neck phantom consisted of simulated skin, fat and muscle layers made of agar and a conductive rubber tube mimicking the common carotid artery. The ring-shaped electrodes with a guard electrode showed the highest sensitivity to emboli at short distances.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico , Enfermedades de las Arterias Carótidas/fisiopatología , Impedancia Eléctrica , Electrodos , Embolia/diagnóstico , Embolia/fisiopatología , Pletismografía de Impedancia/instrumentación , Composición Corporal , Diagnóstico por Computador/instrumentación , Diagnóstico por Computador/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Fantasmas de Imagen , Pletismografía de Impedancia/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Physiol Meas ; 26(2): S39-47, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15798245

RESUMEN

Electrical bioimpedance spectroscopy (EBIS) is a technique that uses a probe to calculate the transfer impedance from tissues. This transfer impedance can give information about the normal or pathological condition of the tissue. To take readings, pressure has to be applied to the probe in order to get a good contact between the electrodes and the tissue. We have been using EBIS to investigate the early diagnosis of dysplasia and cancer in the human cervix, oesophagus and bladder. We have found that, with increasing pressure (range used here was approximately 1 kPa to approximately 50 kPa), the resistivity readings increase in a consistent way up to 80%. In this paper, we show how this is a case in three different tissue types (oesophageal, gastric and vesical samples). These increases can be higher than those associated with the pathological changes that we are investigating (non-inflamed columnar tissue, for instance, shows values 50% higher than dysplastic columnar tissue). Finite-element modelling was also used to investigate the effect of volume reduction in the connective tissue or stroma. This simulation suggests no strong correlation between reduction of this structure and increase in resistivity. We hypothesize therefore that these changes may be mainly associated with the squeezing of water from the extracellular space. Finally, as pressure is difficult to control by hand, we raise the issue of the necessity of considering this variable when making EIS measurements.


Asunto(s)
Tejido Conectivo/fisiología , Diagnóstico por Computador/métodos , Impedancia Eléctrica , Electrodos , Modelos Biológicos , Pletismografía de Impedancia/métodos , Animales , Humanos , Especificidad de Órganos , Pletismografía de Impedancia/instrumentación , Presión , Ratas , Estrés Mecánico , Transductores
9.
Eur J Heart Fail ; 1(4): 379-84, 1999 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10937951

RESUMEN

Acute left ventricular failure (LVF) is a common medical emergency but detection and monitoring of pulmonary oedema remains problematic. Fluid is an important determinant of tissue impedance. Electrical impedance tomography (EIT) is a non-invasive technique allowing localisation of impedance changes within tissue. We have investigated the relationship between LVF and the electrical impedance of lung tissue. Twenty patients with a clinical diagnosis of acute left ventricular failure were compared with 30 normal subjects. Patients were monitored using serial chest radiographs and electrical impedance tomography measurements of lung impedance during hospital admission. Radiographs were graded according to the severity of pulmonary oedema by two independent radiologists. Lung impedance was significantly (P<0.0001) lower than normal in patients with left ventricular failure. Values returned towards the normal range as LVF resolved. There was a similar improvement in the score of the chest radiographs. The electrical impedance of the lung is low in left ventricular failure and increases following treatment.


Asunto(s)
Cardiografía de Impedancia , Tomografía , Disfunción Ventricular Izquierda/diagnóstico , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Impedancia Eléctrica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Edema Pulmonar/complicaciones , Edema Pulmonar/diagnóstico , Reproducibilidad de los Resultados , Disfunción Ventricular Izquierda/complicaciones
10.
Ann N Y Acad Sci ; 873: 313-21, 1999 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-10372179

RESUMEN

Preliminary results of electrical impedance measurements in squamous and columnar epithelia in rat and human tissues are presented. The aim of this work is to show the possibility of differentiating these two types of epithelia in terms of their electrical characteristics. For the measurements, we employed a 1.95-m-long, 3.2-mm-diameter, four-electrode probe designed to be used transendoscopically in the diagnosis of Barrett's esophagus (BE). BE is a condition in which the normal squamous epithelium of the esophagus is replaced by columnar epithelium of the intestinal type. This metaplasia is considered as a premalignant condition that puts patients at a 30-125-fold risk of developing adenocarcinoma of the esophagus. The diagnosis and surveillance of BE involve taking multiple biopsies, an expensive and time-consuming procedure. This study constitutes the first stage in the replacement of tissue biopsy by "virtual biopsies".


Asunto(s)
Esófago de Barrett/patología , Biopsia/métodos , Impedancia Eléctrica , Animales , Endoscopía del Sistema Digestivo/métodos , Células Epiteliales/patología , Neoplasias Esofágicas/patología , Humanos , Lesiones Precancerosas/patología , Ratas
11.
IEEE Trans Biomed Eng ; 42(2): 133-40, 1995 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-7868140

RESUMEN

An instrument is described which produces images of the electrical impedance distribution within the body at a rate of 25 frames per second, allowing lung ventilation and lung perfusion to be observed in real time. The instrument makes impedance measurements using an array of 16 electrodes on the surface of the body, and reconstructs the images using a weighted backprojection technique. The design of the data acquisition electronics and the reconstruction and display processor are described. Some preliminary in vitro and in vivo results from the system are presented.


Asunto(s)
Impedancia Eléctrica , Tomografía/instrumentación , Algoritmos , Calibración , Sistemas de Computación , Electrodos , Diseño de Equipo , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/irrigación sanguínea , Sístole/fisiología
12.
IEEE Trans Biomed Eng ; 41(8): 729-34, 1994 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-7927395

RESUMEN

Electrical impedance measurements have been made from the human trunk over the frequency range 9.6 kHz to 614 kHz. Measurements have been made from 12 normal subjects and the amplitude of the impedance changes associated with the cardiac and respiratory cycles have been recorded. It was found that the real part of the impedance fell to 64.0% of its low frequency value over the measured range of frequencies and that the changes associated with respiration fell in a similar manner. However, the cardiac related changes fell more rapidly with increasing frequency to 28.2% of the low frequency value. The origin of the measured changes is discussed with a view to understanding why the cardiac related changes fall more rapidly. It is not possible to relate in any simple way the frequency dispersion of a single component to that of the whole trunk. However, the results are consistent with the lungs being the major origin of both the cardiac and respiratory related components. The origin of the cardiac related impedance changes could be the pulsatile volume changes in the pulmonary tree. These could be shunted by nonpulsatile lung tissue that has decreasing impedance at high frequency and thus decreases the relative magnitude of the cardiac related changes. This hypothesis needs to be tested using localized measurements from the thorax and 3-D modeling of the trunk.


Asunto(s)
Impedancia Eléctrica , Contracción Miocárdica/fisiología , Respiración/fisiología , Tórax/fisiología , Adulto , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Valores de Referencia
13.
J Matern Fetal Neonatal Med ; 14(6): 389-91, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15061317

RESUMEN

OBJECTIVE: To investigate the use of electrical impedance measurements of the pregnant cervix as an objective measure of cervical favorability (Bishop score > or = 5). METHODS: A prospective study of 86 women, investigating electrical impedance measurements of the pregnant cervix at the time of induction of labor. Transfer electrical impedance measurements were made by placing a tetrapolar pencil probe of 8 mm in diameter on the surface of the cervix. A Bishop score was determined simultaneously. RESULTS: A mean resistivity (standard error of the mean) of 7.03 (6.01-8.04) omega(m) was measured for the unfavorable group and 5.34 (4.61-6.07) omega(m) for the favorable group. This was a statistically significant difference (p = 0.016). CONCLUSION: We highlight the ability of this safe, painless technique to differentiate the favorable from the unfavorable cervix at induction of labor.


Asunto(s)
Cuello del Útero/fisiología , Impedancia Eléctrica , Inicio del Trabajo de Parto/fisiología , Trabajo de Parto Inducido , Adolescente , Adulto , Femenino , Humanos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Embarazo , Estudios Prospectivos
14.
Physiol Meas ; 15 Suppl 2a: A211-6, 1994 May.
Artículo en Inglés | MEDLINE | ID: mdl-8087045

RESUMEN

We first describe experiments designed to measure the spatial distribution of noise within an electrical impedance tomographic image of a saline-filled tank. These experiments show that the noise increases by a factor of up to 30 from the periphery towards the centre of the image. We then propose a method of noise equalization that depends upon spending longer collecting the smaller potentials than the larger potentials. The method is tested and shown to give an improvement in noise uniformity of about 16 dB.


Asunto(s)
Impedancia Eléctrica , Tomografía/instrumentación , Algoritmos , Electrodos , Procesamiento de Imagen Asistido por Computador
15.
Physiol Meas ; 16(3 Suppl A): A39-47, 1995 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8528125

RESUMEN

This paper presents a model that comprises only two parameters (R/S, fr) and the application of three function minimization algorithms (simplex, Powell and modified Powell) to this model to obtain parametric images. Comparisons among the three algorithms in terms of efficiency and reliability were carried out. It was found that, with proper initialization by taking the shape of the modelled data into consideration, the minimization function can be approximated by a quadratic function near the minimum point, therefore the iteration times can be minimized in the modified Powell method. The results show that with the modified Powell method a substantial reduction of computation time can be achieved in the parametric imaging. This makes it possible to obtain a 16 x 16 parametric image in 1 s.


Asunto(s)
Algoritmos , Impedancia Eléctrica , Modelos Biológicos , Distribución Aleatoria
16.
Physiol Meas ; 17 Suppl 4A: A213-25, 1996 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9001620

RESUMEN

ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. In addition there arises an increase in p' in early systole towards the periphery of the lung. Frequency behaviour of p' changes with location. At all times after the R-wave, in the centre of the lung p' is higher at higher frequency f whereas in the periphery it is lower at higher f. The principal decrease in p' can be explained by increasing pulmonary blood volume due to cardiac contraction. The early systolic increase is presumably due to venous return to the left atrium locally leading blood output from the right ventricle which is delayed by the windkessel effect. Based on a model taking extracapillary and capillary blood volume increase into account, the change in frequency behaviour of p' is explained by regional variations in extracapillary blood vessel size determining the relative contributions of extracapillary blood volume and capillary blood volume change to p' at a certain frequency.


Asunto(s)
Impedancia Eléctrica , Corazón/fisiología , Pulmón/fisiología , Tomografía/métodos , Adulto , Volumen Sanguíneo/fisiología , Electrocardiografía , Humanos , Procesamiento de Imagen Asistido por Computador , Pulmón/irrigación sanguínea , Masculino , Matemática , Persona de Mediana Edad , Modelos Biológicos , Circulación Pulmonar/fisiología , Sístole/fisiología
17.
Physiol Meas ; 21(1): 1-6, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10719993

RESUMEN

Multi-frequency electrical impedance tomography (EIT) systems require stable voltage controlled current generators that will work over a wide frequency range and with a large variation in load impedance. In this paper we compare the performance of two commonly used designs: the first is a modified Howland circuit whilst the second is based on a current mirror. The output current and the output impedance of both circuits were determined through PSPICE simulation and through measurement. Both circuits were stable over the frequency ranges 1 kHz to 1 MHz. The maximum variation of output current with frequency for the modified Howland circuit was 2.0% and for the circuit based on a current mirror 1.6%. The output impedance for both circuits was greater than 100 kohms for frequencies up to 100 kHz. However, neither circuit achieved this output impedance at 1 MHz. Comparing the results from the two circuits suggests that there is little to choose between them in terms of a practical implementation.


Asunto(s)
Impedancia Eléctrica , Tomografía/instrumentación , Ingeniería Biomédica , Electrodos , Electrónica Médica , Diseño de Equipo , Estudios de Evaluación como Asunto , Humanos , Tomografía/métodos
18.
Physiol Meas ; 21(1): 79-88, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10720002

RESUMEN

In this paper, we have proposed a technique for reducing movement artefacts in impedance pneumography by placing six electrodes at appropriate locations and suitably combining the measurements obtained. The strategy for electrode placement was based on the observation that the electrodes appeared to slide over the rib cage along with the skin, during movement. A volume conductor model of the thoracic cavity was developed and movement artefacts were simulated by shifting the electrodes to a different location on the surface. The impedance changes due to movement in one of the measurements of a 'symmetrical pair' were 180 degrees out of phase with respect to those observed in the other measurement of that pair. However, the impedance changes due to breathing were in phase in both these measurements. Thus, it was possible to reduce movement artefacts by taking a mean of these measurements without affecting the breathing related changes. The six electrodes could be configured into two such symmetrical pairs. The same observation was made in experimental data recorded from human subjects. This indicated that movement artefacts were caused by sliding of electrodes along with the skin and could be reduced by using the six-electrode configuration.


Asunto(s)
Impedancia Eléctrica , Tomografía/instrumentación , Cardiografía de Impedancia/instrumentación , Cardiografía de Impedancia/métodos , Cardiografía de Impedancia/estadística & datos numéricos , Electrodos , Estudios de Evaluación como Asunto , Humanos , Modelos Anatómicos , Modelos Biológicos , Movimiento , Tórax/anatomía & histología , Tórax/fisiología , Tomografía/métodos , Tomografía/estadística & datos numéricos
19.
Physiol Meas ; 21(1): 137-44, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10720009

RESUMEN

Electrical impedance measurements are used to obtain information about a subject, tissue sample or tissue model under test. There are several ways of obtaining these impedance data and thereafter analysing the data to obtain relevant parameters. This paper shows how a completely isolated drive and receive system using current pulses, as opposed to sine waves, achieves good fitted results with resistor-capacitor Cole phantoms.


Asunto(s)
Impedancia Eléctrica , Tomografía/métodos , Tomografía/estadística & datos numéricos , Interpretación Estadística de Datos , Humanos , Modelos Estadísticos , Tomografía/instrumentación
20.
Physiol Meas ; 23(1): 159-68, 2002 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11876229

RESUMEN

The electrical properties of cervical squamous epithelium have been modelled in the frequency range 100 Hz to 10 MHz. The hierarchical modelling process comprises a cellular level stage, which includes detailed models of cells typical of different depths within the epithelium and a tissue model, which utilizes electrical properties obtained from the cellular models. The fit between the modelled and measured impedance spectra and the distribution of current with depth depends on the macroscopic model structure. Both the properties of the basement membrane and the presence of a surface mucus layer are shown to have a significant effect. The best fit with measured data is obtained when a 10 microm thick, high-conductivity surface layer is included in the tissue model.


Asunto(s)
Carcinoma de Células Escamosas/patología , Neoplasias del Cuello Uterino/patología , Algoritmos , Membrana Basal/fisiología , Membrana Basal/ultraestructura , Núcleo Celular/fisiología , Núcleo Celular/ultraestructura , Impedancia Eléctrica , Células Epiteliales/fisiología , Células Epiteliales/ultraestructura , Femenino , Análisis de Elementos Finitos , Humanos , Membranas/fisiología , Membranas/ultraestructura , Modelos Anatómicos
SELECCIÓN DE REFERENCIAS