RESUMEN
Recent progress has shown that using wavelengths between 1,000 and 2,000 nm, referred to as the shortwave-infrared or near-infrared (NIR)-II range, can enable high-resolution in vivo imaging at depths not possible with conventional optical wavelengths. However, few bioconjugatable probes of the type that have proven invaluable for multiplexed imaging in the visible and NIR range are available for imaging these wavelengths. Using rational design, we have generated persulfonated indocyanine dyes with absorbance maxima at 872 and 1,072 nm through catechol-ring and aryl-ring fusion, respectively, onto the nonamethine scaffold. Multiplexed two-color and three-color in vivo imaging using monoclonal antibody and dextran conjugates in several tumor models illustrate the benefits of concurrent labeling of the tumor and healthy surrounding tissue and lymphatics. These efforts are enabled by complementary advances in a custom-built NIR/shortwave-infrared imaging setup and software package for multicolor real-time imaging.
Asunto(s)
Colorantes Fluorescentes , Neoplasias , Anticuerpos Monoclonales , Humanos , Neoplasias/diagnóstico por imagen , Imagen Óptica/métodos , Espectroscopía Infrarroja Corta/métodosRESUMEN
Optical imaging within the shortwave infrared (SWIR, 1000-2000 nm) region of the electromagnetic spectrum has enabled high-resolution and high-contrast imaging in mice, non-invasively. Polymethine dyes, with their narrow absorption spectra and high absorption coefficients, are optimal probes for fast and multiplexed SWIR imaging. Here, we expand upon the multiplexing capabilities in SWIR imaging by obtaining brighter polymethine dyes with varied excitation wavelengths spaced throughout the near-infrared (700-1000 nm) region. Building on the flavylium polymethine dye scaffold, we explored derivatives with functional group substitution at the 2-position, deemed chromenylium polymethine dyes. The reported dyes have reduced nonradiative rates and enhanced emissive properties, enabling non-invasive imaging in mice in a single color at 300 fps and in three colors at 100 fps. Combined with polymethine dyes containing a red-shifted julolidine flavylium heterocycle and indocyanine green, distinct channels with well-separated excitation wavelengths provide non-invasive video-rate in vivo imaging in four colors.
Asunto(s)
Color , Colorantes Fluorescentes/química , Indoles/química , Imagen Óptica , Animales , Colorantes Fluorescentes/síntesis química , Indoles/síntesis química , Rayos Infrarrojos , Ratones , Estructura MolecularRESUMEN
Recent technology developments have expanded the wavelength window for biological fluorescence imaging into the shortwave infrared. We show here a mechanistic understanding of how drastic changes in fluorescence imaging contrast can arise from slight changes of imaging wavelength in the shortwave infrared. We demonstrate, in 3D tissue phantoms and in vivo in mice, that light absorption by water within biological tissue increases image contrast due to attenuation of background and highly scattered light. Wavelengths of strong tissue absorption have conventionally been avoided in fluorescence imaging to maximize photon penetration depth and photon collection, yet we demonstrate that imaging at the peak absorbance of water (near 1,450 nm) results in the highest image contrast in the shortwave infrared. Furthermore, we show, through microscopy of highly labeled ex vivo biological tissue, that the contrast improvement from water absorption enables resolution of deeper structures, resulting in a higher imaging penetration depth. We then illustrate these findings in a theoretical model. Our results suggest that the wavelength-dependent absorptivity of water is the dominant optical property contributing to image contrast, and is therefore crucial for determining the optimal imaging window in the infrared.
Asunto(s)
Rayos Infrarrojos , Modelos Teóricos , Imagen Óptica/métodos , Agua/química , Animales , Ratones , Imagen Óptica/instrumentaciónRESUMEN
Fluorescence imaging is a method of real-time molecular tracking in vivo that has enabled many clinical technologies. Imaging in the shortwave IR (SWIR; 1,000-2,000 nm) promises higher contrast, sensitivity, and penetration depths compared with conventional visible and near-IR (NIR) fluorescence imaging. However, adoption of SWIR imaging in clinical settings has been limited, partially due to the absence of US Food and Drug Administration (FDA)-approved fluorophores with peak emission in the SWIR. Here, we show that commercially available NIR dyes, including the FDA-approved contrast agent indocyanine green (ICG), exhibit optical properties suitable for in vivo SWIR fluorescence imaging. Even though their emission spectra peak in the NIR, these dyes outperform commercial SWIR fluorophores and can be imaged in the SWIR, even beyond 1,500 nm. We show real-time fluorescence imaging using ICG at clinically relevant doses, including intravital microscopy, noninvasive imaging in blood and lymph vessels, and imaging of hepatobiliary clearance, and show increased contrast compared with NIR fluorescence imaging. Furthermore, we show tumor-targeted SWIR imaging with IRDye 800CW-labeled trastuzumab, an NIR dye being tested in multiple clinical trials. Our findings suggest that high-contrast SWIR fluorescence imaging can be implemented alongside existing imaging modalities by switching the detection of conventional NIR fluorescence systems from silicon-based NIR cameras to emerging indium gallium arsenide-based SWIR cameras. Using ICG in particular opens the possibility of translating SWIR fluorescence imaging to human clinical applications. Indeed, our findings suggest that emerging SWIR-fluorescent in vivo contrast agents should be benchmarked against the SWIR emission of ICG in blood.
Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Medios de Contraste , Colorantes Fluorescentes , Rayos Infrarrojos , Microscopía Intravital/métodos , Vasos Linfáticos/diagnóstico por imagen , Animales , Bovinos , Medios de Contraste/farmacocinética , Medios de Contraste/farmacología , Colorantes Fluorescentes/farmacocinética , Colorantes Fluorescentes/farmacología , Verde de Indocianina , Ratones , Microscopía Fluorescente/métodos , Trastuzumab/farmacocinética , Trastuzumab/farmacologíaRESUMEN
Medical imaging is routine in the diagnosis and staging of a wide range of medical conditions. In particular, magnetic resonance imaging (MRI) is critical for visualizing soft tissue and organs, with over 60 million MRI procedures performed each year worldwide. About one-third of these procedures are contrast-enhanced MRI, and gadolinium-based contrast agents (GBCAs) are the mainstream MRI contrast agents used in the clinic. GBCAs have shown efficacy and are safe to use with most patients; however, some GBCAs have a small risk of adverse effects, including nephrogenic systemic fibrosis (NSF), the untreatable condition recently linked to gadolinium (Gd) exposure during MRI with contrast. In addition, Gd deposition in the human brain has been reported following contrast, and this is now under investigation by the US Food and Drug Administration (FDA). To address a perceived need for a Gd-free contrast agent with pharmacokinetic and imaging properties comparable to GBCAs, we have designed and developed zwitterion-coated exceedingly small superparamagnetic iron oxide nanoparticles (ZES-SPIONs) consisting of â¼3-nm inorganic cores and â¼1-nm ultrathin hydrophilic shell. These ZES-SPIONs are free of Gd and show a high T1 contrast power. We demonstrate the potential of ZES-SPIONs in preclinical MRI and magnetic resonance angiography.
Asunto(s)
Medios de Contraste/farmacocinética , Óxido Ferrosoférrico/química , Imagen por Resonancia Magnética/métodos , Nanopartículas de Magnetita/química , Albúminas/química , Albúminas/farmacocinética , Animales , Medios de Contraste/química , Óxido Ferrosoférrico/farmacocinética , Óxido Ferrosoférrico/orina , Gadolinio DTPA/química , Gadolinio DTPA/farmacocinética , Gadolinio DTPA/orina , Humanos , Imagen por Resonancia Magnética/instrumentación , Nanopartículas de Magnetita/administración & dosificación , Ratones , Ácido Oléico/química , Tamaño de la Partícula , Distribución TisularRESUMEN
Tissue is translucent to shortwave infrared (SWIR) light, rendering optical imaging superior in this region. However, the widespread use of optical SWIR imaging has been limited, in part, by the lack of bright, biocompatible contrast agents that absorb and emit light above 1000 nm. J-Aggregation offers a means to transform stable, near-infrared (NIR) fluorophores into red-shifted SWIR contrast agents. Here we demonstrate that J-aggregates of NIR fluorophore IR-140 can be prepared inside hollow mesoporous silica nanoparticles (HMSNs) to result in nanomaterials that absorb and emit SWIR light. The J-aggregates inside PEGylated HMSNs are stable for multiple weeks in buffer and enable high resolution imaging in vivo with 980 nm excitation.
Asunto(s)
Benzotiazoles/química , Medios de Contraste/química , Nanopartículas/química , Dióxido de Silicio/química , Animales , Benzotiazoles/efectos de la radiación , Benzotiazoles/toxicidad , Medios de Contraste/efectos de la radiación , Medios de Contraste/toxicidad , Estabilidad de Medicamentos , Rayos Infrarrojos , Ratones Desnudos , Nanopartículas/toxicidad , Imagen Óptica/métodos , Polietilenglicoles/química , Polietilenglicoles/toxicidad , Dióxido de Silicio/toxicidadRESUMEN
The first ever demonstration of temporal focusing with short wave infrared (SWIR) excitation and emission is demonstrated, achieving a penetration depth of 500 µm in brain tissue. This is substantially deeper than the highest previously-reported values for temporal focusing imaging in brain tissue, and demonstrates the value of these optimized wavelengths for neurobiological applications.
RESUMEN
Visualizing structures deep inside opaque biological tissues is one of the central challenges in biomedical imaging. Optical imaging with visible light provides high resolution and sensitivity; however, scattering and absorption of light by tissue limits the imaging depth to superficial features. Imaging with shortwave infrared light (SWIR, 1-2 µm) shares many advantages of visible imaging, but light scattering in tissue is reduced, providing sufficient optical penetration depth to noninvasively interrogate subsurface tissue features. However, the clinical potential of this approach has been largely unexplored because suitable detectors, until recently, have been either unavailable or cost prohibitive. Here, taking advantage of newly available detector technology, we demonstrate the potential of SWIR light to improve diagnostics through the development of a medical otoscope for determining middle ear pathologies. We show that SWIR otoscopy has the potential to provide valuable diagnostic information complementary to that provided by visible pneumotoscopy. We show that in healthy adult human ears, deeper tissue penetration of SWIR light allows better visualization of middle ear structures through the tympanic membrane, including the ossicular chain, promontory, round window niche, and chorda tympani. In addition, we investigate the potential for detection of middle ear fluid, which has significant implications for diagnosing otitis media, the overdiagnosis of which is a primary factor in increased antibiotic resistance. Middle ear fluid shows strong light absorption between 1,400 and 1,550 nm, enabling straightforward fluid detection in a model using the SWIR otoscope. Moreover, our device is easily translatable to the clinic, as the ergonomics, visual output, and operation are similar to a conventional otoscope.
Asunto(s)
Diagnóstico por Imagen/métodos , Oído Medio/diagnóstico por imagen , Rayos Infrarrojos , Otoscopía/métodos , Oído Medio/fisiopatología , HumanosRESUMEN
The use of visible/NIR-emitting gold nanoclusters (Au NCs), previously proposed for in vivo imaging, has been limited to some extent by low quantum yields (QYs) and the limited penetration of visible light in tissue. Here we report short wavelength infrared (SWIR, λ = 1-2 µm) emitting Au NCs with a good photoluminescence QY for this wavelength range (0.6% to 3.8% for λem = 1000 to 900 nm) and excellent stability under physiological conditions. We show that surface ligand chemistry is critical to achieving these properties. We demonstrate the potential of these SWIR-emitting Au NCs for in vivo imaging in mice. The Au NCs have a hydrodynamic diameter that is small (â¼5 nm) enough that they exhibit a rapid renal clearance, and images taken in the SWIR region show better resolution of the blood vessels than in the NIR region.
Asunto(s)
Betaína/análogos & derivados , Oro/química , Sustancias Luminiscentes/química , Nanopartículas del Metal/química , Imagen Óptica/métodos , Animales , Betaína/análisis , Betaína/química , Oro/análisis , Rayos Infrarrojos , Luz , Sustancias Luminiscentes/análisis , Mediciones Luminiscentes/métodos , Nanopartículas del Metal/análisis , Ratones , Ondas de RadioRESUMEN
Bright fluorophores in the near-infrared and shortwave infrared (SWIR) regions of the electromagnetic spectrum are essential for optical imaging inâ vivo. In this work, we utilized a 7-dimethylamino flavylium heterocycle to construct a panel of novel red-shifted polymethine dyes, with emission wavelengths from 680 to 1045â nm. Photophysical characterization revealed that the 1- and 3-methine dyes display enhanced photostability and the 5- and 7-methine dyes exhibit exceptional brightness for their respective spectral regions. A micelle formulation of the 7-methine facilitated SWIR imaging in mice. This report presents the first polymethine dye designed and synthesized for SWIR inâ vivo imaging.
RESUMEN
Micelles have been employed to encapsulate the supramolecular assembly of quantum dots with palladium(II) porphyrins for the quantification of O2 levels in aqueous media and in vivo. Förster resonance energy transfer from the quantum dot (QD) to the palladium porphyrin provides a means for signal transduction under both one- and two-photon excitation. The palladium porphyrins are sensitive to O2 concentrations in the range of 0-160 Torr. The micelle-encapsulated QD-porphyrin assemblies have been employed for in vivo multiphoton imaging and lifetime-based oxygen measurements in mice with chronic dorsal skinfold chambers or cranial windows. Our results establish the utility of the QD-micelle approach for in vivo biological sensing applications.
Asunto(s)
Técnicas de Química Analítica/instrumentación , Metaloporfirinas/química , Micelas , Oxígeno/análisis , Fotones , Puntos Cuánticos/química , Animales , Cápsulas , Ratones , Modelos Moleculares , Conformación Molecular , Imagen Molecular , Paladio/químicaRESUMEN
BACKGROUND & AIMS: It is well-known that the liver can induce immune tolerance, yet this knowledge could, thus far, not be translated into effective treatments for autoimmune diseases. We have previously shown that liver sinusoidal endothelial cells (LSECs) could substantially contribute to hepatic tolerance through their ability to induce CD4+ Foxp3+ regulatory T cells (Tregs). Here, we explored whether the Treg-inducing potential of LSECs could be harnessed for the treatment of autoimmune disease. METHODS: We engineered a polymeric nanoparticle (NP) carrier for the selective delivery of autoantigen peptides to LSECs in vivo. In the well-characterized autoimmune disease model of experimental autoimmune encephalomyelitis (EAE), we investigated whether administration of LSEC-targeting autoantigen peptide-loaded NPs could protect mice from autoimmune disease. RESULTS: We demonstrate that NP-based autoantigen delivery to LSECs could completely and permanently prevent the onset of clinical EAE. More importantly, in a therapeutic approach, mice with already established EAE improved rapidly and substantially following administration of a single dose of autoantigen peptide-loaded NPs, whereas the control group deteriorated. Treatment efficacy seemed to depend on Tregs. The Treg frequencies in the spleens of mice treated with autoantigen peptide-loaded NPs were significantly higher than those in vehicle-treated mice. Moreover, NP-mediated disease control was abrogated after Treg depletion by repeated administration of Treg-depleting antibody. CONCLUSION: Our findings provide proof of principle that the selective delivery of autoantigen peptides to LSECs by NPs can induce antigen-specific Tregs and enable effective treatment of autoimmune disease. These findings highlight the importance of Treg induction by LSECs for immune tolerance.
Asunto(s)
Autoantígenos/administración & dosificación , Enfermedades Autoinmunes/prevención & control , Hígado/citología , Hígado/inmunología , Linfocitos T Reguladores/inmunología , Animales , Enfermedades Autoinmunes/inmunología , Autoinmunidad , Sistemas de Liberación de Medicamentos , Encefalomielitis Autoinmune Experimental/inmunología , Encefalomielitis Autoinmune Experimental/prevención & control , Células Endoteliales/inmunología , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Proteína Básica de Mielina/administración & dosificación , Proteína Básica de Mielina/inmunología , Glicoproteína Mielina-Oligodendrócito/administración & dosificación , Glicoproteína Mielina-Oligodendrócito/inmunología , Nanopartículas/administración & dosificación , Fragmentos de Péptidos/administración & dosificación , Fragmentos de Péptidos/inmunologíaRESUMEN
This article represents the first foray into investigating the consequences of various material combinations on the short-wave infrared (SWIR, 1000-2000 nm) performance of Tm-based core-shell nanocrystals (NCs) above 1600 nm. In total, six different material combinations involving two different types of SWIR-emitting core NCs (α-NaTmF4 and LiTmF4) combined with three different protecting shell materials (α-NaYF4, CaF2, and LiYF4) have been synthesized. All corresponding homo- and heterostructured NCs have been meticulously characterized by powder X-ray diffraction and electron microscopy techniques. The latter revealed that out of the six investigated combinations, only one led to the formation of a true core-shell structure with well-segregated core and shell domains. The direct correlation between the downshifting performance and the spatial localization of Tm3+ ions within the final homo- and heterostructured NCs is established. Interestingly, to achieve the best SWIR performance, the formation of an abrupt interface is not a prerequisite, while the existence of a pure (even thin) protective shell is vital. Remarkably, although all homo- and heterostructured NCs have been synthesized under the exact same experimental conditions, Tm3+ SWIR emission is either fully quenched or highly efficient depending on the type of material combination. The most efficient combination (LiTmF4/LiYF4) achieved a high photoluminescence quantum yield of 39% for SWIR emission above 1600 nm (excitation power density in the range 0.5-3 W/cm2) despite significant intermixing. From now on, highly efficient SWIR-emitting probes with an emission above 1600 nm are within reach to unlock the full potential of in vivo SWIR imaging.
RESUMEN
BACKGROUND & AIMS: The liver can mitigate the inflammatory activity of infiltrating T cells by mechanisms that are not entirely clear. Here we investigated the role of liver sinusoidal endothelial cells (LSECs) in regulating the activity of inflammatory CD4 T cells. METHODS: Interactions between T helper (Th) 1 or Th17 cells and LSEC were studied by intravital microscopy and by in vitro stimulation assays. RESULTS: Circulating CD4 T cells established lasting and repeated interactions with liver endothelium in vivo. Stimulation of Th1 and Th17 cells by LSEC greatly inhibited their capacity to secrete interferon-γ or interleukin-17 in vitro; in contrast, stimulation by dendritic cells (DCs) resulted in considerable secretion of both cytokines. Cytokine release by Th1 or Th17 cells seemed to be actively suppressed by LSEC, as indicated by the inhibition of cytokine secretion even in the presence of Th1- and Th17-promoting DC. This inhibition of CD4 T cell effector function seemed to depend on the dominance of inhibitory over activating co-stimulatory signals on LSEC, since (1) cytokine secretion could be restored by increased CD28 co-activation; (2) LSEC from interleukin-10(-/-) mice, which manifest increased activating signals, such as MHC II, and decreased inhibitory signals, such as PD-L1, failed to suppress cytokine secretion; and (3) cytokine secretion by Th1 or Th17 cells that lacked PD-1, the ligand for inhibitory PD-L1, could not be suppressed by LSEC. CONCLUSIONS: LSEC inhibit inflammatory cytokine secretion of Th1 and Th17 effector CD4 T cells in dependence of interleukin-10 and PD-1.
Asunto(s)
Linfocitos T CD4-Positivos/inmunología , Comunicación Celular/inmunología , Células Endoteliales/inmunología , Hígado/inmunología , Animales , Linfocitos T CD4-Positivos/citología , Diferenciación Celular/inmunología , Células Cultivadas , Células Dendríticas/citología , Células Dendríticas/inmunología , Células Endoteliales/citología , Femenino , Tolerancia Inmunológica/inmunología , Interleucina-10/genética , Interleucina-10/inmunología , Hígado/citología , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Receptor de Muerte Celular Programada 1/genética , Receptor de Muerte Celular Programada 1/inmunología , Transducción de Señal/inmunología , Células TH1/citología , Células TH1/inmunología , Células Th17/citología , Células Th17/inmunologíaRESUMEN
Extracting biological information from awake and unrestrained mice is imperative to in vivo basic and pre-clinical research. Accordingly, imaging methods which preclude invasiveness, anesthesia, and/or physical restraint enable more physiologically relevant biological data extraction by eliminating these extrinsic confounders. In this article, we discuss the recent development of shortwave infrared (SWIR) fluorescent imaging to visualize peripheral organs in freely-behaving mice, as well as propose potential applications of this imaging modality in the neurosciences.
RESUMEN
Significance: Cerebrospinal fluid (CSF) rhinorrhea (leakage of brain fluid from the nose) can be difficult to identify and currently requires invasive procedures, such as intrathecal fluorescein, which requires a lumbar drain placement. Fluorescein is also known to have rare but significant side effects including seizures and death. As the number of endonasal skull base cases increases, the number of CSF leaks has also increased for which an alternative diagnostic method would be highly advantageous to patients. Aim: We aim to develop an instrument to identify CSF leaks based on water absorption in the shortwave infrared (SWIR) without the need of intrathecal contrast agents. This device needed to be adapted to the anatomy of the human nasal cavity while maintaining low weight and ergonomic characteristics of current surgical instruments. Approach: Absorption spectra of CSF and artificial CSF were obtained to characterize the absorption peaks that could be targeted with SWIR light. Different illumination systems were tested and refined prior to adapting them into a portable endoscope for testing in 3D-printed models and cadavers for feasibility. Results: We identified CSF to have an identical absorption profile as water. In our testing, a narrowband laser source at 1480 nm proved superior to using a broad 1450 nm LED. Using a SWIR enabling endoscope set up, we tested the ability to detect artificial CSF in a cadaver model. Conclusions: An endoscopic system based on SWIR narrowband imaging can provide an alternative in the future to invasive methods of CSF leak detection.
Asunto(s)
Pérdida de Líquido Cefalorraquídeo , Rinorrea de Líquido Cefalorraquídeo , Humanos , Pérdida de Líquido Cefalorraquídeo/cirugía , Rinorrea de Líquido Cefalorraquídeo/cirugía , Endoscopía/métodos , Base del Cráneo/diagnóstico por imagen , Base del Cráneo/cirugía , Fluoresceína , Estudios RetrospectivosRESUMEN
Extracting biological information from awake and unrestrained mice is imperative to in vivo basic and pre-clinical research. Accordingly, imaging methods which preclude invasiveness, anesthesia, and/or physical restraint enable more physiologically relevant biological data extraction by eliminating these extrinsic confounders. In this article we discuss the recent development of shortwave infrared (SWIR) fluorescent imaging to visualize peripheral organs in freely-behaving mice, as well as propose potential applications of this imaging modality in the neurosciences.
RESUMEN
Short-wave infrared (SWIR) fluorescence could become the new gold standard in optical imaging for biomedical applications due to important advantages such as lack of autofluorescence, weak photon absorption by blood and tissues, and reduced photon scattering coefficient. Therefore, contrary to the visible and NIR regions, tissues become translucent in the SWIR region. Nevertheless, the lack of bright and biocompatible probes is a key challenge that must be overcome to unlock the full potential of SWIR fluorescence. Although rare-earth-based core-shell nanocrystals appeared as promising SWIR probes, they suffer from limited photoluminescence quantum yield (PLQY). The lack of control over the atomic scale organization of such complex materials is one of the main barriers limiting their optical performance. Here, the growth of either homogeneous (α-NaYF4) or heterogeneous (CaF2) shell domains on optically-active α-NaYF4:Yb:Er (with and without Ce3+ co-doping) core nanocrystals is reported. The atomic scale organization can be controlled by preventing cation intermixing only in heterogeneous core-shell nanocrystals with a dramatic impact on the PLQY. The latter reached 50% at 60 mW/cm2; one of the highest reported PLQY values for sub-15 nm nanocrystals. The most efficient nanocrystals were utilized for in vivo imaging above 1450 nm.
RESUMEN
In response to cold exposure, thermogenic adipocytes internalize large amounts of fatty acids after lipoprotein lipase-mediated hydrolysis of triglyceride-rich lipoproteins (TRL) in the capillary lumen of brown adipose tissue (BAT) and white adipose tissue (WAT). Here, we show that in cold-exposed mice, vascular endothelial cells in adipose tissues endocytose substantial amounts of entire TRL particles. These lipoproteins subsequently follow the endosomal-lysosomal pathway, where they undergo lysosomal acid lipase (LAL)-mediated processing. Endothelial cell-specific LAL deficiency results in impaired thermogenic capacity as a consequence of reduced recruitment of brown and brite/beige adipocytes. Mechanistically, TRL processing by LAL induces proliferation of endothelial cells and adipocyte precursors via beta-oxidation-dependent production of reactive oxygen species, which in turn stimulates hypoxia-inducible factor-1α-dependent proliferative responses. In conclusion, this study demonstrates a physiological role for TRL particle uptake into BAT and WAT and establishes endothelial lipoprotein processing as an important determinant of adipose tissue remodeling during thermogenic adaptation.
Asunto(s)
Tejido Adiposo Pardo/metabolismo , Tejido Adiposo Blanco/metabolismo , Lipoproteínas/metabolismo , Lisosomas/metabolismo , Termogénesis , Triglicéridos/metabolismo , Adiponectina/genética , Adiponectina/metabolismo , Tejido Adiposo Pardo/patología , Tejido Adiposo Blanco/patología , Animales , Antígenos CD36/metabolismo , Diferenciación Celular , Proliferación Celular , Frío , Células Endoteliales/citología , Células Endoteliales/metabolismo , Humanos , Subunidad alfa del Factor 1 Inducible por Hipoxia/metabolismo , Lipoproteínas/genética , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Especies Reactivas de Oxígeno/metabolismo , Receptores de Lipoproteína/genética , Receptores de Lipoproteína/metabolismo , Esterol Esterasa/deficiencia , Esterol Esterasa/genética , Esterol Esterasa/metabolismo , Triglicéridos/genéticaRESUMEN
In this study we systematically developed a potential MR T(1) contrast agent based on very small PEGylated iron oxide nanoparticles. We adjusted the size of the crystalline core providing suitable relaxometric properties. In addition, a dense and optimized PEG coating provides high stability under physiological conditions together with low cytotoxicity and low nonspecific phagocytosis into macrophage cells as a part of the reticulo endothelial system at biologically relevant concentrations. The as developed contrast agent has the lowest r(2)/r(1) ratio (2.4) at 1.41 T reported so far for PEGylated iron oxide nanoparticles as well as a r(1) relaxivity (7.3 mM(-1) s(-1)) that is two times higher compared to that of Magnevist as a typical T(1) contrast agent based on gadolinium as a clinical standard.