Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 243
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Clin Infect Dis ; 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38466039

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

2.
Eur Radiol ; 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38418626

RESUMEN

RATIONALE: To provide an overview of the current status of cardiac multimodality imaging practices in Europe and radiologist involvement using data from the European Society of Cardiovascular Radiology (ESCR) MRCT-registry. MATERIALS AND METHODS: Numbers on cardiac CT and MRI examinations were extracted from the MRCT-registry of the ESCR, entered between January 2011 and October 2023 (n = 432,265). Data collection included the total/annual numbers of examinations, indications, complications, and reporting habits. RESULTS: Thirty-two countries contributed to the MRCT-registry, including 29 European countries. Between 2011 and 2022, there was a 4.5-fold increase in annually submitted CT examinations, from 3368 to 15,267, and a 3.8-fold increase in MRI examinations, from 3445 to 13,183. The main indications for cardiac CT were suspected coronary artery disease (CAD) (59%) and transcatheter aortic valve replacement planning (21%). The number of patients with intermediate pretest probability who underwent CT for suspected CAD showed an increase from 61% in 2012 to 82% in 2022. The main MRI indications were suspected myocarditis (26%), CAD (21%), and suspected cardiomyopathy (19%). Adverse event rates were very low for CT (0.3%) and MRI (0.7%) examinations. Reporting of CT and MRI examinations was performed mainly by radiologists (respectively 76% and 71%) and, to a lesser degree, in consensus with non-radiologists (19% and 27%, respectively). The remaining examinations (4.9% CT and 1.7% MRI) were reported by non-radiological specialties or in separate readings of radiologists and non-radiologists. CONCLUSIONS: Real-life data on cardiac imaging in Europe using the largest available MRCT-registry demonstrate a considerable increase in examinations over the past years, the vast majority of which are read by radiologists. These findings indicate that radiologists contribute to meeting the increasing demands of competent and effective care in cardiac imaging to a relevant extent. CLINICAL RELEVANCE STATEMENT: The number of cardiac CT and MRI examinations has risen over the past years, and radiologists read the vast majority of these studies as recorded in the MRCT-registry. KEY POINTS: • The number of cardiac imaging examinations is constantly increasing. • Radiologists play a central role in providing cardiac CT and MR imaging services to a large volume of patients. • Cardiac CT and MR imaging examinations performed and read by radiologists show a good safety profile.

3.
Eur Radiol ; 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38789792

RESUMEN

BACKGROUND: The aim of our current systematic dynamic phantom study was first, to optimize reconstruction parameters of coronary CTA (CCTA) acquired on photon counting CT (PCCT) for coronary artery calcium (CAC) scoring, and second, to assess the feasibility of calculating CAC scores from CCTA, in comparison to reference calcium scoring CT (CSCT) scans. METHODS: In this phantom study, an artificial coronary artery was translated at velocities corresponding to 0, < 60, and 60-75 beats per minute (bpm) within an anthropomorphic phantom. The density of calcifications was 100 (very low), 200 (low), 400 (medium), and 800 (high) mgHA/cm3, respectively. CCTA was reconstructed with the following parameters: virtual non-iodine (VNI), with and without iterative reconstruction (QIR level 2, QIR off, respectively); kernels Qr36 and Qr44f; slice thickness/increment 3.0/1.5 mm and 0.4/0.2 mm. The agreement in risk group classification between CACCCTA and CACCSCT scoring was measured using Cohen weighted linear κ with 95% CI. RESULTS: For CCTA reconstructed with 0.4 mm slice thickness, calcium detectability was perfect (100%). At < 60 bpm, CACCCTA of low, and medium density calcification was underestimated by 53%, and 15%, respectively. However, CACCCTA was not significantly different from CACCSCT of very low, and high-density calcifications. The best risk agreement was achieved when CCTA was reconstructed with QIR off, Qr44f, and 0.4 mm slice thickness (κ = 0.762, 95% CI 0.671-0.853). CONCLUSION: In this dynamic phantom study, the detection of calcifications with different densities was excellent with CCTA on PCCT using thin-slice VNI reconstruction. Agatston scores were underestimated compared to CSCT but agreement in risk classification was substantial. CLINICAL RELEVANCE STATEMENT: Photon counting CT may enable the implementation of coronary artery calcium scoring from coronary CTA in daily clinical practice. KEY POINTS: Photon-counting CTA allows for excellent detectability of low-density calcifications at all heart rates. Coronary artery calcium scoring from coronary CTA acquired on photon counting CT is feasible, although improvement is needed. Adoption of the standard acquisition and reconstruction protocol for calcium scoring is needed for improved quantification of coronary artery calcium to fully employ the potential of photon counting CT.

4.
Eur Radiol ; 34(7): 4261-4272, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38114847

RESUMEN

OBJECTIVES: To compare cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) for the quantitative assessment of the left ventricular (LV) trabeculated layer in patients with suspected noncompaction cardiomyopathy (NCCM). MATERIALS AND METHODS: Subjects with LV excessive trabeculation who underwent both CMR and CCT imaging as part of the prospective international multicenter NONCOMPACT clinical study were included. For each subject, short-axis CCT and CMR slices were matched. Four quantitative metrics were estimated: 1D noncompacted-to-compacted ratio (NCC), trabecular-to-myocardial area ratio (TMA), trabecular-to-endocardial cavity area ratio (TCA), and trabecular-to-myocardial volume ratio (TMV). In 20 subjects, end-diastolic and mid-diastolic CCT images were compared for the quantification of the trabeculated layer. Relationships between the metrics were investigated using linear regression models and Bland-Altman analyses. RESULTS: Forty-eight subjects (49.9 ± 12.8 years; 28 female) were included in this study. NCC was moderately correlated (r = 0.62), TMA and TMV were strongly correlated (r = 0.78 and 0.78), and TCA had excellent correlation (r = 0.92) between CMR and CCT, with an underestimation bias from CCT of 0.3 units, and 5.1, 4.8, and 5.4 percent-points for the 4 metrics, respectively. TMA, TCA, and TMV had excellent correlations (r = 0.93, 0.96, 0.94) and low biases (- 3.8, 0.8, - 3.8 percent-points) between the end-diastolic and mid-diastolic CCT images. CONCLUSIONS: TMA, TCA, and TMV metrics of the LV trabeculated layer in patients with suspected NCCM demonstrated high concordance between CCT and CMR images. TMA and TCA were highly reproducible and demonstrated minimal differences between mid-diastolic and end-diastolic CCT images. CLINICAL RELEVANCE STATEMENT: The results indicate similarity of CCT to CMR for quantifying the LV trabeculated layer, and the small differences in quantification between end-diastole and mid-diastole demonstrate the potential for quantifying the LV trabeculated layer from clinically performed coronary CT angiograms. KEY POINTS: • Data on cardiac CT for quantifying the left ventricular trabeculated layer are limited. • Cardiac CT yielded highly reproducible metrics of the left ventricular trabeculated layer that correlated well with metrics defined by cardiac MR. • Cardiac CT appears to be equivalent to cardiac MR for the quantification of the left ventricular trabeculated layer.


Asunto(s)
Ventrículos Cardíacos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Adulto
5.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38472038

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Asunto(s)
Infecciones Cardiovasculares , Endocarditis , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Consenso , Tomografía Computarizada por Rayos X , Imagen Multimodal , Endocarditis/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único
6.
Radiol Med ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38935247

RESUMEN

PURPOSE: To determine the optimal window setting for virtual monoenergetic images (VMI) reconstructed from dual-layer spectral coronary computed tomography angiography (DE-CCTA) datasets. MATERIAL AND METHODS: 50 patients (30 males; mean age 61.1 ± 12.4 years who underwent DE-CCTA from May 2021 to June 2022 for suspected coronary artery disease, were retrospectively included. Image quality assessment was performed on conventional images and VMI reconstructions at 70 and 40 keV. Objective image quality was assessed using contrast-to-noise ratio (CNR). Two independent observers manually identified the best window settings (B-W/L) for VMI 70 and VMI 40 visualization. B-W/L were then normalized with aortic attenuation using linear regression analysis to obtain the optimized W/L (O-W/L) settings. Additionally, subjective image quality was evaluated using a 5-point Likert scale, and vessel diameters were measured to examine any potential impact of different W/L settings. RESULTS: VMI 40 demonstrated higher CNR values compared to conventional and VMI 70. B-W/L settings identified were 1180/280 HU for VMI 70 and 3290/900 HU for VMI 40. Subsequent linear regression analysis yielded O-W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40. VMI 40 O-W/L received the highest scores for each parameter compared to conventional (all p < 0.0027). Using O-W/L settings for VMI 70 and VMI 40 did not result in significant differences in vessel measurements compared to conventional images. CONCLUSION: Optimization of VMI requires adjustments in W/L settings. Our results recommend W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40.

7.
Radiology ; 309(1): e222432, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37787672

RESUMEN

CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal. PCCT advancements include, among the most important, improved spatial resolution, noise reduction, and spectral properties. PCCT spatial resolution on the order of 0.25 mm allows for the improved visualization of small structures (eg, small vessels, arterial walls, distal bronchi, and bone trabeculations) and their pathologies, as well as the identification of previously undetectable anomalies. In addition, blooming artifacts from calcifications, stents, and other dense structures are reduced. The benefits of the spectral capabilities of PCCT are broad and include reducing radiation and contrast material dose for patients. In addition, multiple types of information can be extracted from a single data set (ie, multiparametric imaging), including quantitative data often regarded as surrogates of functional information (eg, lung perfusion). PCCT also allows for a novel type of CT imaging, K-edge imaging. This technique, combined with new contrast materials specifically designed for this modality, opens the door to new applications for imaging in the future.


Asunto(s)
Arterias , Tomografía Computarizada por Rayos X , Humanos , Artefactos , Bronquios , Medios de Contraste
8.
Eur Radiol ; 2023 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-37940711

RESUMEN

OBJECTIVES: To compare coronary artery calcification (CAC) scores measured on virtual non-contrast (VNC) and virtual non-iodine (VNI) reconstructions computed from coronary computed tomography angiography (CCTA) using photon-counting computed tomography (PCCT) to true non-contrast (TNC) images. METHODS: We included 88 patients (mean age = 59 years ± 13.5, 69% male) who underwent a TNC coronary calcium scan followed by CCTA on PCCT. VNC images were reconstructed in 87 patients and VNI in 88 patients by virtually removing iodine from the CCTA images. For all reconstructions, CAC scores were determined, and patients were classified into risk categories. The overall agreement of the reconstructions was analyzed by Bland-Altman plots and the level of matching classifications. RESULTS: The median CAC score on TNC was 27.8 [0-360.4] compared to 8.5 [0.2-101.6] (p < 0.001) on VNC and 72.2 [1.3-398.8] (p < 0.001) on VNI. Bland-Altman plots depicted a bias of 148.8 (ICC = 0.82, p < 0.001) and - 57.7 (ICC = 0.95, p < 0.001) for VNC and VNI, respectively. Of all patients with CACTNC = 0, VNC reconstructions scored 63% of the patients correctly, while VNI scored 54% correctly. Of the patients with CACTNC > 0, VNC and VNI reconstructions detected the presence of coronary calcium in 90% and 92% of the patients. CACVNC tended to underestimate CAC score, whereas CACVNI overestimated, especially in the lower risk categories. According to the risk categories, VNC misclassified 55% of the patients, while VNI misclassified only 32%. CONCLUSION: Compared to TNC images, VNC underestimated and VNI overestimated the actual CAC scores. VNI reconstructions quantify and classify coronary calcification scores more accurately than VNC reconstructions. CLINICAL RELEVANCE STATEMENT: Photon-counting CT enables spectral imaging, which might obviate the need for non-contrast enhanced coronary calcium scoring, but optimization is necessary for the clinical implementation of the algorithms. KEY POINTS: • Photon-counting computed tomography uses spectral information to virtually remove the signal of contrast agents from contrast-enhanced scans. • Virtual non-contrast reconstructions tend to underestimate coronary artery calcium scores compared to true non-contrast images, while virtual non-iodine reconstructions tend to overestimate the calcium scores. • Virtual non-iodine reconstructions might obviate the need for non-contrast enhanced calcium scoring, but optimization is necessary for the clinical implementation of the algorithms.

9.
Eur Radiol ; 33(1): 294-301, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35852576

RESUMEN

OBJECTIVE: To describe the prevalence and consequences of incidental findings when implementing routine noncontrast CT prior to cardiac surgery. METHODS: In the multicenter randomized controlled CRICKET study, 862 adult patients scheduled for cardiac surgery were randomized 1:1 to undergo standard of care (SoC), which included a chest-radiograph, or an additional preoperative noncontrast chest CT-scan (SoC+CT). In this subanalysis, all incidental findings detected on the chest radiograph and CT-scan were analyzed. The influence of smoking status on incidental findings was also evaluated, adjusting for sex, age, and group allocation. RESULTS: Incidental findings were observed in 11.4% (n = 49) of patients in the SoC+CT group and in 3.7% (n = 16) of patients in the SoC-group (p < 0.001). The largest difference was observed in findings requiring follow-up (SoC+CT 7.7% (n = 33) vs SoC 2.3% (n = 10), p < 0.001). Clinically relevant findings changing the surgical approach or requiring specific treatment were observed in 10 patients (1.2%, SoC+CT: 1.6% SoC: 0.7%), including lung cancer in 0.5% of patients (n = 4) and aortic dilatation requiring replacement in 0.2% of patients (n = 2). Incidental findings were more frequent in patients who stopped smoking (OR 1.91, 1.03-3.63) or who actively smoked (OR 3.91, 1.85-8.23). CONCLUSIONS: Routine CT-screening increases the rate of incidental findings, mainly by identifying more pulmonary findings requiring follow-up. Incidental findings are more prevalent in patients with a history of smoking, and preoperative CT might increase the yield of identifying lung cancer in these patients. Incidental findings, but not specifically the use of routine CT, are associated with delay of surgery. KEY POINTS: • Clinically relevant incidental findings are identified more often after a routine preoperative CT-scan, when compared to a standard of care workup, with some findings changing patient management. • Patients with a history of smoking have a higher rate of incidental findings and a lung cancer rate comparable to that of lung cancer screening trials. • We observed no clear delay in the time to surgery when adding routine CT screening.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Gryllidae , Neoplasias Pulmonares , Adulto , Animales , Humanos , Hallazgos Incidentales , Detección Precoz del Cáncer , Neoplasias Pulmonares/etiología , Tomografía Computarizada por Rayos X/métodos , Procedimientos Quirúrgicos Cardíacos/efectos adversos
10.
Eur Radiol ; 33(7): 4668-4675, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36729174

RESUMEN

PURPOSE: To systematically assess the radiation dose reduction potential of coronary artery calcium (CAC) assessments with photon-counting computed tomography (PCCT) by changing the tube potential for different patient sizes with a dynamic phantom. METHODS: A hollow artery, containing three calcifications of different densities, was translated at velocities corresponding to 0, < 60, 60-75, and > 75 beats per minute within an anthropomorphic phantom. Extension rings were used to simulate average- and large -sized patients. PCCT scans were made with the reference clinical protocol (tube potential of 120 kilovolt (kV)), and with 70, 90, Sn100, Sn140, and 140 kV at identical image quality levels. All acquisitions were reconstructed at a virtual monoenergetic energy level of 70 keV. For each calcification, Agatston scores and contrast-to-noise ratios (CNR) were determined, and compared to the reference with Wilcoxon signed-rank tests, with p < 0.05 indicating significant differences. RESULTS: A decrease in radiation dose (22%) was achieved at Sn100 kV for the average-sized phantom. For the large phantom, Sn100 and Sn140 kV resulted in a decrease in radiation doses of 19% and 3%, respectively. Irrespective of CAC density, Sn100 and 140 kVp did not result in significantly different CNR. Only at Sn100 kV were there no significant differences in Agatston scores for all CAC densities, heart rates, and phantom sizes. CONCLUSION: PCCT at tube voltage of 100 kV with added tin filtration and reconstructed at 70 keV enables a ≥ 19% dose reduction compared to 120 kV, independent of phantom size, CAC density, and heart rate. KEY POINTS: • Photon-counting CT allows for reduced radiation dose acquisitions (up to 19%) for coronary calcium assessment by reducing tube voltage while reconstructing at a normal monoE level of 70 keV. • Tube voltage reduction is possible for medium and large patient sizes, without affecting the Agatston score outcome.


Asunto(s)
Calcinosis , Calcio , Humanos , Vasos Coronarios/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen
11.
Eur Radiol ; 33(1): 330-338, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35986769

RESUMEN

OBJECTIVES: Increasing evidence suggests a role for epicardial fat in the development of coronary artery disease in the general population. Heart transplantation patients are at increased risk of developing a specific form of coronary artery disease, cardiac allograft vasculopathy (CAV), which has far-reaching consequences in terms of morbidity and mortality. Until now, the role of epicardial fat volume (EFV) in the development of CAV remains unknown. Hence, we investigated the relationship between EFV and CAV as well as the influence of donor/recipient sex on EFV. METHODS: Adult heart transplant patients who underwent coronary computed tomography angiography (CCTA) for CAV screening who were four or more years post-HT were included. Using the CT examinations, we quantified the EFV and the degree of CAV. Ordinal and linear regression models were used to assess the association of EFV with CAV. RESULTS: In total, 149 (median age 44.5 years, 36% women) patients were included. The median time between HT and the CT scan was 11.0 (7.3-16.1) years. CAV grade 0, 1, 2 and 3 were seen in 85 (57%), 32 (22%), 14 (9%), and 18 (12%) patients, respectively. The median EFV was 208.4 (128.9-276.0) mL. Larger EFV were related to higher degrees of CAV (median of 164.7 to 290.6 mL for CAV grade 0 and 3, respectively, OR 5.23 (2.47-11.06), p < 0.001). Male recipients had significantly more EFV than female recipients irrespective of the donor sex (232.7 mL vs. 147.2 mL respectively, p < 0.001). Determinants for EFV were recipient sex, number of rejections, donor age, time between HT and CT scan, recipient BMI, and diabetes mellitus. CONCLUSIONS: EFV was associated with higher degrees of CAV. The recipient sex influenced the EFV more than the donor sex. KEY POINTS: • Patients after heart transplantation have a high amount of epicardial fat while larger amounts of epicardial fat are related to higher grades of cardiac allograft vasculopathy. • Determinants of higher epicardial fat volume included recipient sex, number of rejections, donor age, time between HT and CT scan, recipient BMI, and diabetes mellitus. • Longitudinal studies are needed to further disentangle the role of epicardial fat in the development and progression of cardiac allograft vasculopathy. Demonstration of four patients (from CAV grade 0 to CAV grade 3) in whom epicardial fat volume was determined. In red, the voxels identified as epicardial fat.


Asunto(s)
Enfermedad de la Arteria Coronaria , Cardiopatías , Trasplante de Corazón , Adulto , Humanos , Femenino , Masculino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Pericardio/diagnóstico por imagen , Trasplante de Corazón/efectos adversos , Cardiopatías/etiología , Aloinjertos , Angiografía Coronaria , Factores de Riesgo
12.
Eur Radiol ; 33(2): 1088-1101, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36194266

RESUMEN

The European Society of Cardiovascular Radiology (ESCR) is the European specialist society of cardiac and vascular imaging. This society's highest priority is the continuous improvement, development, and standardization of education, training, and best medical practice, based on experience and evidence. The present intra-society consensus is based on the existing scientific evidence and on the individual experience of the members of the ESCR writing group on carotid diseases, the members of the ESCR guidelines committee, and the members of the executive committee of the ESCR. The recommendations published herein reflect the evidence-based society opinion of ESCR. The purpose of this second document is to discuss suggestions for standardized reporting based on the accompanying consensus document part I. KEY POINTS: • CT and MR imaging-based evaluation of carotid artery disease provides essential information for risk stratification and prediction of stroke. • The information in the report must cover vessel morphology, description of stenosis, and plaque imaging features. • A structured approach to reporting ensures that all essential information is delivered in a standardized and consistent way to the referring clinician.


Asunto(s)
Enfermedades de las Arterias Carótidas , Radiología , Humanos , Consenso , Imagen por Resonancia Magnética/métodos , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
13.
Eur Radiol ; 33(2): 1063-1087, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36194267

RESUMEN

The European Society of Cardiovascular Radiology (ESCR) is the European specialist society of cardiac and vascular imaging. This society's highest priority is the continuous improvement, development, and standardization of education, training, and best medical practice, based on experience and evidence. The present intra-society consensus is based on the existing scientific evidence and on the individual experience of the members of the ESCR writing group on carotid diseases, the members of the ESCR guidelines committee, and the members of the executive committee of the ESCR. The recommendations published herein reflect the evidence-based society opinion of ESCR. We have produced a twin-papers consensus, indicated through the documents as respectively "Part I" and "Part II." The first document (Part I) begins with a discussion of features, role, indications, and evidence for CT and MR imaging-based diagnosis of carotid artery disease for risk stratification and prediction of stroke (Section I). It then provides an extensive overview and insight into imaging-derived biomarkers and their potential use in risk stratification (Section II). Finally, detailed recommendations about optimized imaging technique and imaging strategies are summarized (Section III). The second part of this consensus paper (Part II) is focused on structured reporting of carotid imaging studies with CT/MR. KEY POINTS: • CT and MR imaging-based evaluation of carotid artery disease provides essential information for risk stratification and prediction of stroke. • Imaging-derived biomarkers and their potential use in risk stratification are evolving; their correct interpretation and use in clinical practice must be well-understood. • A correct imaging strategy and scan protocol will produce the best possible results for disease evaluation.


Asunto(s)
Aterosclerosis , Enfermedades de las Arterias Carótidas , Radiología , Accidente Cerebrovascular , Humanos , Consenso , Tomografía Computarizada por Rayos X/métodos , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Imagen por Resonancia Magnética , Estándares de Referencia
14.
J Nucl Cardiol ; 30(3): 1210-1218, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36348248

RESUMEN

BACKGROUND: The clinical diagnosis of deep sternal wound infection (DSWI) is supported by imaging findings including 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT). To avoid misinterpretation due to normal post-surgery inflammation we assessed normal imaging findings in non-infected patients after sternotomy. METHODS: This is a prospective cohort study including non-infectious patients with sternotomy. All patients underwent 18F-FDG-PET/CT at either 5 weeks (group 1), 12 weeks (group 2) or 52 weeks (group 3) post-surgery. 18F-FDG uptake was scored visually in five categories and assessed quantitatively. RESULTS: A total of 44 patients were included. Sternal mean SUVmax was 7.34 (± 1.86), 5.22 (± 2.55) and 3.20 (± 1.80) in group 1, 2 and 3, respectively (p < 0.01). Sternal mean SUVmean was 3.84 (± 1.00), 2.69 (± 1.32) and 1.71 (± 0.98) in group 1, 2 and 3 (p < 0.01). All patients in group 1 had elevated uptake whereas group 2 and 3 showed 2/15 (13%) and 11/20 (55%) patients respectively with no elevated uptake. Group 3 still showed an elevated uptake pattern in in 9/20 (45%) and in 3/9 (33%) with a high-grade diffuse uptake pattern. CONCLUSION: This study shows significant lower sternal 18F-FDG at 55 weeks compared to 5 weeks post-sternotomy however elevated uptake patterns may persist.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Esternotomía , Estudios Prospectivos
15.
Radiology ; 304(1): 208-215, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35412363

RESUMEN

Background Thoracic aortic diameter may have a role as a biomarker for major adverse cardiovascular events. Purpose To evaluate the sex-specific association of the diameters of the ascending (AA) and descending (DA) thoracic aorta with risk of stroke, coronary heart disease, heart failure, cardiovascular mortality, and all-cause mortality. Materials and Methods Study participants from the population-based Rotterdam Study who underwent multidetector-row CT between 2003 and 2006 were evaluated. Cox proportional hazard models were conducted to evaluate the associations of AA and DA diameters indexed and not indexed for body mass index (BMI) with cardiovascular events and mortality for men and women. Hazard ratios (HRs) were calculated per 1-unit greater SD of aortic diameters. Results A total of 2178 participants (mean age, 69 years; 55% women) were included. Mean follow-up was 9 years. Each 0.23-mm/(kg/m2) larger BMI-indexed AA diameter was associated with a 33% higher cardiovascular mortality risk in women (HR, 1.33; 95% CI: 1.03, 1.73). Each 0.16-mm/(kg/m2) larger BMI-indexed DA diameter was associated with a 38% higher risk of stroke (HR, 1.38; 95% CI: 1.07, 1.78) and with a 46% greater risk of cardiovascular mortality (HR, 1.46; 95% CI: 1.10, 1.94) in women. Larger BMI-indexed AA and DA diameters were associated with greater risk of all-cause mortality in both sexes. Conclusion Larger ascending and descending thoracic aortic diameters indexed by body mass index were associated with greater risk of adverse cardiovascular outcomes and mortality in women and men. Clinical trial registration no. NTR6831 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Williams in this issue.


Asunto(s)
Enfermedades Cardiovasculares , Accidente Cerebrovascular , Anciano , Aorta Torácica/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico por imagen , Femenino , Humanos , Masculino , Tomografía Computarizada Multidetector , Modelos de Riesgos Proporcionales , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico por imagen
16.
Eur Radiol ; 32(1): 442-447, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34327574

RESUMEN

OBJECTIVE: To assess the influence of breathing state on the accuracy of a 3D camera for body contour detection and patient positioning in thoracic CT. MATERIALS AND METHODS: Patients who underwent CT of the thorax with both an inspiratory and expiratory scan were prospectively included for analysis of differences in the ideal table height at different breathing states. For a subgroup, an ideal table height suggestion based on 3D camera images at both breathing states was available to assess their influence on patient positioning accuracy. Ideal patient positioning was defined as the table height at which the scanner isocenter coincides with the patient's isocenter. RESULTS: The mean (SD) difference of the ideal table height between the inspiratory and the expiratory breathing state among the 64 included patients was 10.6 mm (4.5) (p < 0.05). The mean (SD) positioning accuracy, i.e., absolute deviation from the ideal table height, within the subgroup (n = 43) was 4.6 mm (7.0) for inspiratory scans and 7.1 mm (7.7) for expiratory scans (p < 0.05) when using corresponding 3D camera images. The mean (SD) accuracy was 14.7 mm (7.4) (p < 0.05) when using inspiratory camera images on expiratory scans; vice versa, the accuracy was 3.1 mm (9.5) (p < 0.05). CONCLUSION: A 3D camera allows for accurate and precise patient positioning if the camera image and the subsequent CT scan are acquired in the same breathing state. It is recommended to perform an expiratory planning image when acquiring a thoracic CT scan in both the inspiratory and expiratory breathing state. KEY POINTS: • A 3D camera for body contour detection allows for accurate and precise patient positioning if the camera image and the subsequent CT scan are acquired in the same breathing state. • It is recommended to perform an expiratory planning image when acquiring a thoracic CT scan in both the inspiratory and expiratory breathing state.


Asunto(s)
Tórax , Tomografía Computarizada por Rayos X , Humanos , Imagenología Tridimensional , Posicionamiento del Paciente , Estudios Retrospectivos
17.
Eur Radiol ; 32(8): 5201-5209, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35230517

RESUMEN

OBJECTIVES: The aim of this study was to determine mono-energetic (monoE) level-specific photon-counting CT (PCCT) Agatston thresholds, to yield monoE level independent Agatston scores validated with a dynamic cardiac phantom. Also, we examined the potential of dose reduction for PCCT coronary artery calcium (CAC) studies, when reconstructed at low monoE levels. METHODS: Theoretical CAC monoE thresholds were calculated with data from the National Institute of Standards and Technology (NIST) database. Artificial CAC with three densities were moved in an anthropomorphic thorax phantom at 0 and 60-75 bpm, and scanned at full and 50% dose on a first-generation dual-source PCCT. For all densities, Agatston scores and maximum CT numbers were determined. Agatston scores were compared with the reference at full dose and 70 keV monoE level; deviations (95% confidence interval) < 10% were deemed to be clinically not-relevant. RESULTS: Averaged over all monoE levels, measured CT numbers deviated from theoretical CT numbers by 6%, 13%, and - 4% for low-, medium-, and high-density CAC, respectively. At 50% reduced dose and 60-75 bpm, Agatston score deviations were non-relevant for 60 to 100 keV and 60 to 120 keV for medium- and high-density CAC, respectively. CONCLUSION: MonoE level-specific Agatston score thresholds resulted in similar scores as in standard reconstructions at 70 keV. PCCT allows for a potential dose reduction of 50% for CAC scoring using low monoE reconstructions for medium- and high-density CAC. KEY POINTS: • Mono-energy level-specific Agatston thresholds allow for reproducible coronary artery calcium quantification on mono-energetic images. • Increased calcium contrast-to-noise ratio at reduced mono-energy levels allows for coronary artery calcium quantification at 50% reduced radiation dose for medium- and high-density calcifications.


Asunto(s)
Calcio , Enfermedad de la Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Reducción Gradual de Medicamentos , Humanos , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos
18.
Eur Radiol ; 32(3): 1843-1852, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34523009

RESUMEN

OBJECTIVES: Invasively measured fractional flow reserve (FFR) is associated with outcome in heart transplant (HTx) patients. Coronary computed tomography angiography (CCTA)-derived FFR (FFRct) provides additional functional information from anatomical CT images. We describe the first use of FFRct in HTx patients. METHODS: HTx patients underwent CCTA with FFRct to screen for cardiac allograft vasculopathy. FFRct was measured distal to each coronary stenosis > 30% and FFRct ≤ 0.8 indicated hemodynamically significant stenosis. FFRct was also measured at the most distal location of each vessel. Overall distal FFRct was calculated as the mean of the distal values in the left, right, and circumflex coronary artery in each patient. RESULTS: Seventy-three patients (age 56 (42-65) years, 63% males) at 11 (8-16) years after HTx were included. Eighteen (25%) patients had a focal hemodynamically significant stenosis (stenosis > 30% with FFRct ≤ 0.8). In the 55 patients without a hemodynamically significant focal FFRct stenosis (FFRct > 0.80), the distal left anterior descending artery FFRct was < 0.90 in 74% of the patients and 10 (18%) patients had ≥ 1 coronary artery with a distal FFRct ≤ 0.8, including 1 with a distal FFRct ≤ 0.8 in all coronaries. Overall distal FFRct in patients without focal stenosis was 0.88 (0.86-0.91), 0.87 (0.86-0.90), and 0.88 (0.86-0.91) (median with 25th-75th percentile) at 5-9, 10-14, or ≥ 15 years post-transplantation, respectively (p = 0.93). CONCLUSIONS: FFRct performed on CCTA scans of HTx patients demonstrated that 25% of patients had a focal coronary stenosis with FFRct ≤ 0.8. Even without a focal stenosis, FFRct values are often abnormal in HTx patients. KEY POINTS: • This is the first report describing the use of FFRct in in heart transplant patients. • FFRct identifies patients after heart transplantation with hemodynamically significant coronary stenosis. • Even without a focal stenosis, FFRct values are often abnormal in heart transplant patients.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Trasplante de Corazón , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X
19.
Eur Radiol ; 32(4): 2611-2619, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34783875

RESUMEN

OBJECTIVES: To evaluate if routine screening for aortic calcification using unenhanced CT lowers the risk of stroke and alters the surgical approach in patients undergoing general cardiac surgery compared with standard of care (SoC). METHODS: In this prospective, multicenter, randomized controlled trial, adult patients scheduled for cardiac surgery from September 2014 to October 2019 were randomized 1:1 into two groups: SoC alone, including chest radiography, vs. SoC plus preoperative noncontrast CT. The primary endpoint was in-hospital perioperative stroke. Secondary endpoints were preoperative change of the surgical approach, in-hospital mortality, and postoperative delirium. The trial was halted halfway for expected futility, as the conditional power analysis showed a chance < 1% of finding the hypothesized effect. RESULTS: A total of 862 patients were evaluated (SoC-group: 433 patients (66 ± 11 years; 74.1% male) vs. SoC + CT-group: 429 patients (66 ± 10 years; 69.9% male)). The perioperative stroke rate (SoC + CT: 2.1%, 9/429 vs. SoC: 1.2%, 5/433, p = 0.27) and rate of changed surgical approach (SoC + CT: 4.0% (17/429) vs. SoC: 2.8% (12/433, p = 0.35) did not differ between groups. In-hospital mortality and postoperative delirium were comparable between groups. In the SoC + CT group, aortic calcification was observed on CT in the ascending aorta in 28% (108/380) and in the aortic arch in 70% (265/379). CONCLUSIONS: Preoperative noncontrast CT in cardiac surgery candidates did not influence the surgical approach nor the incidence of perioperative stroke compared with standard of care. Aortic calcification is a frequent finding on the CT scan in these patients but results in major surgical alterations to prevent stroke in only few patients. KEY POINTS: • Aortic calcification is a frequent finding on noncontrast computed tomography prior to cardiac surgery. • Routine use of noncontrast computed tomography does not often lead to a change of the surgical approach, when compared to standard of care. • No effect was observed on perioperative stroke after cardiac surgery when using routine noncontrast computed tomography screening on top of standard of care.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Gryllidae , Accidente Cerebrovascular , Adulto , Animales , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Femenino , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Tomografía Computarizada por Rayos X/efectos adversos
20.
J Nucl Cardiol ; 29(6): 2938-2948, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-34708302

RESUMEN

BACKGROUND: To diagnose abnormal 18F-Fluorodeoxyglucose (18F-FDG) uptake in suspected endocarditis after aortic root and/or ascending aorta prosthesis (ARAP) implantation, it is important to first establish the normal periprosthetic uptake on positron emission tomography with computed tomography (PET/CT). METHODS: Patients with uncomplicated ARAP implantation were prospectively included and underwent 18F-FDG-PET/CT at either 12 (± 2) weeks (group 1) or 52 (± 8) weeks (group 2) after procedure. Uptake on three different locations of the prosthesis ("cranial anastomosis (CA)," "prosthetic heart valve (PHV)," "ascending aorta prosthesis (AAP)") was scored visually (none/low/intermediate/high) and quantitatively (maximum standardized uptake value (SUVmax) and target-to-background ratio (SUVratio). RESULTS: In total, 20 patients (group 1: n = 10, group 2: n = 10) (mean age 64±7 years, 70% male) were included. Both groups had similar visual uptake intensity for all measured areas (CA: mostly low-intermediate (16/20 (80%)), p = .17; PHV: low-intermediate (16/20 (80%)), p = .88; AAP: low-intermediate (19/20 (95%)), p = .48). SUVmax for CA was 5.6 [4.1-6.1] and 3.8 [3.1-5.9] (median [IQR], p = .19), and around PHV 5.0 [4.1-5.7] and 6.3 [4.6-7.1] (p = .11) for groups 1 and 2, respectively. SUVratio for CA was 2.8 [2.3-3.2] and 2.0 [1.7-2.6] (median [IQR], p = .07) and around PHV 2.5 [2.4-2.8] and 2.9 [2.3-3.5] (median [IQR], p = .26) for groups 1 and 2, respectively. CONCLUSION: No significant differences were observed between PET/CT findings at 3 months and 1 year after ARAP implantation, warranting caution in interpretation of PET/CT in the first year after implantation.


Asunto(s)
Fluorodesoxiglucosa F18 , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Aorta Torácica , Radiofármacos , Tomografía de Emisión de Positrones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA