Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Obstet Gynaecol Res ; 49(7): 1717-1722, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37150848

RESUMEN

AIM: The aim of this study was to investigate whether there is a new factor in the etiology of recurrent loss of pregnancy. For this purpose, serum malondialdehyde (MDA) and nitric oxide (NO) levels as indicators of oxidative stress, and endocan levels, a marker of vascular dysfunction, were investigated in patients diagnosed with habitual abortion. MATERIALS AND METHODS: The research was conducted as a prospective case-control study. Patients aged 18-40 years with two or more consecutive pregnancy losses revealed by ultrasonographic or histopathological examination, and with no pathology capable of causing habitual abortion were included in the study group. Patients with no history of abortion, with at least one healthy pregnancy, who were planning pregnancies, and who presented to the outpatient clinic for routine prepregnancy tests were selected as the control group. Two groups were established-habitual abortion (n = 30) and control (n = 29). At the end of the menstrual cycle, blood samples were collected and centrifuged. Serum NO, MDA, and endocan levels were studied. RESULTS: Serum endocan, NO, and MDA levels were higher in women with habitual abortion compared to healthy controls. Pearson's correlation analysis revealed a positive correlation between serum endocan levels and NO and MDA levels. A positive correlation was also observed between serum MDA and NO levels. Multiple regression was run to predict serum endocan levels from MDA and NO levels. These variables emerged as statistically significant predictors of endocan. CONCLUSION: These findings suggest the presence of vascular endothelial dysfunction in patients with habitual abortion.


Asunto(s)
Aborto Habitual , Aborto Inducido , Embarazo , Humanos , Femenino , Estudios de Casos y Controles , Proteínas de Neoplasias , Proteoglicanos , Biomarcadores
2.
Clin Chem Lab Med ; 54(5): 857-63, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26466167

RESUMEN

BACKGROUND: Most of the factors causing preanalytical and analytical variation in ammonia measurement have been identified. Biological variation data for ammonia is still lacking. We therefore estimated the components of biological variation (within-subject=CVI and between-subject=CVG), reference change value (RCV) and quality specifications for ammonia in a group of healthy individuals using fresh and frozen plasma samples. METHODS: Blood samples from 20 healthy subjects were collected in K2EDTA tubes daily over a period of 4 consecutive days from each subject. Each plasma sample was split into two aliquots; one was immediately analyzed as the samples were collected and the other was stored -80 °C until testing at the end of the collection period and analyzed at once in one analytical run. All samples were analyzed in duplicate. Estimations were calculated according to Fraser and Harris methods. RESULTS: CVI value for fresh samples (13.78%) was significantly lower than that in frozen samples (18.91%) (p<0.001). However, there was no statistically significant difference in CVG values between fresh (16.91%) and frozen (18.43%) samples (p=0.570). The index of individuality did not exceed 1.4 for fresh and frozen samples. The estimated RCVs were high for both fresh and frozen samples (43.37% and 56.85%, respectively). Quality specifications were established. CONCLUSIONS: The present study for the first time described the components of biological variation for ammonia in healthy individuals. These data regarding biological variation of ammonia could be useful for a better evaluation of ammonia test results in clinical interpretation and for determining quality specifications based on biological variation.


Asunto(s)
Amoníaco/sangre , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
3.
J Med Biochem ; 35(1): 1-6, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28356858

RESUMEN

BACKGROUND: Sample classification and registration have been recognized as important and time-consuming processes in laboratories. There is increasing pressure on laboratories to automate processes due to intense workload and reduce manual procedures and errors. The aim of the present study was to evaluate the positive effects of an automatic tube registration and sorting system on specimen processing. METHODS: An automatic tube registration and sorting system (HCTS2000 MK2, m-u-t AG, Wedel, Germany) was evaluated. Turnaround time (TAT), rate of sample rejection and unrealized tests were examined 12 months pre- and post-implementation of the automatic tube sorting and registration system. RESULTS: The mean TAT of routine chemistry immunoassay, complete blood cell count (CBC) and coagulation samples were significantly improved (P<0.001). The number of rejected samples and unrealized tests was insignificantly decreased post-implementation of the system (0.4% to 0.2% and 4.5% to 1.4%, respectively) (P>0.05). CONCLUSIONS: By reducing delays and errors in the preanalytical processing and sorting of samples, significant improvements in specimen processing were observed after implementation of the system. These results suggest that an automatic tube registration and sorting system may also be used to improve specimen processing in a higher-volume core laboratory.

4.
Clin Biochem ; 49(6): 486-491, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26655254

RESUMEN

OBJECTIVES: We assessed the analytical performance of newly developed Access 25(OH) Vitamin D Total assay with Beckman Coulter Unicel DXI 800 and evaluated the agreement between a reference method liquid chromatography/tandem mass spectrometry (LC-MS/MS) and a chemiluminescence method (LIAISON, DiaSorin). DESIGN AND METHODS: 160 serum samples were included. Deming Regression analysis and Bland-Altman plots were used. The concordance correlation coefficient (CCC) was used to assess the degree of agreement between assays and the reference method. RESULTS: The CV% values of Unicel DXI 800 for within-run, between-run and between-day were lower than 6%. When compared to LC-MS/MS, the Access 25(OH) Vitamin D Total assay demonstrated an R value of 0.9444 (intercept -0.089, slope 0.951), with an average bias of -2.9%, and the LIAISON 25(OH) Vitamin D Total assay an R value of 0.9405 (intercept -0605, slope 0.924), with an average bias of -13.6%. In comparison with the LIAISON 25(OH) Vitamin D Total assay, the Access 25(OH) Vitamin D Total assay demonstrated an R value of 0.9498 (intercept 0.528, slope 1.029), with an average bias of 1.2%. The agreement with the LC-MS/MS method, based on values of the CCC, was moderate for the Unicel DXI 800 and LIAISON method (0.95, 0.94 respectively). CONCLUSIONS: The new, automated Access 25(OH) Vitamin D Total assay showed an acceptable correlation with LC-MS/MS and LIAISON. Both methods moderately achieved to classify the patients according to their vitamin D status. However, we need further standardization of vitamin D assays to enhance the accuracy and comparability.


Asunto(s)
Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Vitamina D/análogos & derivados , Humanos , Reproducibilidad de los Resultados , Vitamina D/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA