Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Int J Mol Sci ; 24(21)2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37958857

RESUMEN

There is evidence that surgical site tissue (SSRT) released during orthopedic surgery has a strong mesenchymal regenerative potential. Some data also suggest that this tissue may activate synthetic or natural bone substitute materials and can thus upgrade its osteopromoting properties. In this comparative in vitro study, we investigate the composition of SSRT during total hip replacement (n = 20) harvested using a surgical suction handle. In addition, the osteopromoting effect of the cells isolated from SSRT is elucidated when incubated with porous beta-tricalcium phosphate (ß-TCP) or 80% medical-grade poly-ε-caprolactone (PCL)/20% TCP composite material. We identified multiple growth factors and cytokines with significantly higher levels of PDGF and VEGF in SSRT compared to peripheral blood. The overall number of MSC was 0.09 ± 0.12‱ per gram of SSRT. A three-lineage specific differentiation was possible in all cases. PCL-TCP cultures showed a higher cell density and cell viability compared to TCP after 6 weeks in vitro. Moreover, PCL-TCP cultures showed a higher osteocalcin expression but no significant differences in osteopontin and collagen I synthesis. We could demonstrate the high regenerative potential from SSRT harvested under vacuum in a PMMA filter device. The in vitro data suggest advantages in cytocompatibility for the PCL-TCP composite compared to TCP alone.


Asunto(s)
Sustitutos de Huesos , Andamios del Tejido , Poliésteres/farmacología , Huesos , Fosfatos de Calcio/farmacología , Colágeno Tipo I , Ingeniería de Tejidos
2.
BMC Musculoskelet Disord ; 23(1): 620, 2022 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-35764987

RESUMEN

BACKGROUND: In the past, radiographic imaging was of minor relevance in the diagnosis of periprosthetic joint infections (PJI). Since metal artefact reduction sequences (MARS) are available, magnetic resonance imaging (MRI) has become a promising diagnostic tool for the evaluation of hip arthroplasty implants. The purpose of the present study was to evaluate the efficacy of MARS-MRI in comparison to established diagnostic tools to distinguish between aseptic failure and PJI. METHODS: From July 2018 to September 2019, 33 patients classified as having an aseptic joint effusion were recruited into the study. The group included 22 women and 11 men with a mean age of 70.4 ± 13.7 (42-88) years. In the same period, 12 patients were classified as having a PJI. The group consisted of 9 women and 3 men with a mean age of 72.5 ± 10.6 (54-88) years. MARS-MRI was conducted using the optimized parameters at 1.5 T in a coronal and axial STIR (short-tau-inversion recovery), a non-fat-saturated T2 in coronal view and a non-fat-saturated T1 in transverse view in 45 patients with painful hip after total hip arthroplasty (THA). Normally distributed continuous data were shown as mean ± standard deviation (SD) and compared using student's t-test. Non-normally distributed continuous data were shown as mean and compared using the Mann-Whitney U test. RESULTS: Synovial layering and muscle edema were significant features of periprosthetic joint infection, with sensitivities of 100% and specifities of 63.0-75.0%. The combined specifity and sensitivity levels of synovial layering and muscular edema was 88.0% and 90.0%. Granulomatous synovitis was a significant feature for aseptic failure, with 90.0% sensitivity and 57.0% specifity. CONCLUSION: MARS-MRI is as suitable as standard diagnostic tools to distinguish between aseptic failure and PJI in patients with THA. Further studies with larger patient numbers have to prove whether MARS-MRI could be integral part of PJI diagnostic.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Anciano , Anciano de 80 o más Años , Artritis Infecciosa/diagnóstico , Artroplastia de Reemplazo de Cadera/efectos adversos , Artefactos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/etiología
3.
Int J Mol Sci ; 22(9)2021 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-33922517

RESUMEN

Bone substitutes have been applied to treat osseous defects for a long time. To prevent implant related infection (IRI) and enhance bone healing functionalized biomaterials, antibiotics and osteoinductive substances have been introduced. This study gives an overview of the current available surface-coated bone substitutes and provides an outlook for future perspectives.


Asunto(s)
Infecciones Bacterianas/tratamiento farmacológico , Sustitutos de Huesos/química , Sustitutos de Huesos/uso terapéutico , Huesos/efectos de los fármacos , Animales , Infecciones Bacterianas/microbiología , Materiales Biocompatibles/química , Materiales Biocompatibles/uso terapéutico , Humanos
4.
Arch Orthop Trauma Surg ; 141(6): 891-897, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32474699

RESUMEN

INTRODUCTION: Inaccurate stem implantation can cause unsatisfactory offset reconstruction and may result in insufficient gluteal muscle function or aseptic loosening. In this study, stem alignment of a collarless straight tapered HA-coated stem was retrospectively analyzed during the learning phase of the direct anterior approach (DAA) for primary total hip arthroplasty (THA). MATERIAL AND METHODS: From Jan 2013 to Jun 2015, a total of 93 cementless THA were implanted in patients with unilateral coxarthrosis via the DAA in a two surgeon setting using the Corail® or Trendhip® stem (DePuy Synthes or Aesculap). Varus(+)/Valgus(-) stem alignment was analyzed in postoperative anteroposterior pelvic radiographs. Effects on femoral offset reconstruction and correlation to patient's individual clinical and radiological parameters were evaluated. RESULTS: 55 stems were implanted in varus (59%), 32 in neutral (34%) and 6 in valgus alignment (7%). Mean stem alignment in varus position was + 2.2° (SD ± 1.4°). Varus alignment was associated with male gender and preoperative coxa vara deformity: low CCD, high femoral offset and long thigh neck (p ≤ 0.001). Alignment was not correlated to femoral offset restoration, BMI or leg length difference. Mean cup inclination was 44° (SD ± 4.7°) and 90% matched the coronal Lewinnek safe zone. CONCLUSION: In the learning curve, the DAA can be associated with a high incidence of varus stem alignment when using a straight tapered stem, especially in men with coxa vara deformity: low CCD, high femoral offset and long thigh neck. An insufficient capsule release makes femur exposure more difficult and might be an additional factor for this finding. We recommend intraoperative X-ray in the learning phase of the DAA to verify correct implant positioning and to adjust offset options.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Humanos , Masculino , Osteoartritis de la Cadera/cirugía , Falla de Prótesis , Estudios Retrospectivos
5.
Orthopade ; 50(3): 245-256, 2021 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-33543309

RESUMEN

Arthroplasty of the shoulder joint leads to excellent clinical results if the indications are valid and the implantation is technically correct. Taking anatomical requirements and mechanical functions as well as material properties and developments in surgical techniques into account, articulations and anchoring systems have been developed which, as modular systems enable successful restoration of the biomechanics and consider the importance of the surrounding soft tissues. Scientific data show promising medium-term and long-term results in terms of functionality and pain reduction. Nevertheless, due to the limited bone stock for implant anchoring, especially loosening of the prosthesis or instability of the glenoid joint component, revision arthroplasty remains challenging. This review article summarizes the relevant aspects of shoulder arthroplasty.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Articulación del Hombro , Prótesis de Hombro , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento
6.
BMC Musculoskelet Disord ; 21(1): 257, 2020 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-32312264

RESUMEN

BACKGROUND: Since a "gold-standard" is missing, diagnosing periprosthetic joint infection (PJI) remains a challenge in orthopedic surgery. The purpose of this study was to evaluate the accuracy of serum and synovial fluid Procalcitonin (S-PCT and SF-PCT) as a diagnostic parameter and to compare it to the biomarkers recommended in the 2018 Definition of periprosthetic hip and knee infection. METHODS: Between August 2018 and July 2019, a prospective cohort study was conducted in 70 patients with painful hip, shoulder and knee arthroplasty. Besides medical history, clinical and laboratory data was gathered. PJI was diagnosed based on the 2018 Definition of periprosthetic hip and knee infection. Preoperative blood and synovial joint fluid were taken for PCT measurement. S-PCT and SF-PCT levels were measured using standard quantitative PCT enzyme immunoassays. RESULTS: Twenty three patients (33%) were classified as the PJI group and fourty seven patient (67%) as the aseptic group. The mean levels of S-PCT were significantly (p <  0.001) higher in the PJI group than those in the aseptic group (PJI 0.05 ± 0.21 ng/mL (0.0-1.03) vs. aseptic 0.02 ± 0.03 ng/mL (0.0-0.18)). In synovial fluid, the mean PCT values in the aseptic group were significantly higher (p <  0.001) than those of PJI group (PJI 2.7 ± 1.4 ng/mL (0.53-9.7) vs. aseptic 8.7 ± 2.5 ng/mL (0.25-87.9)). S- PCT, with a cut-off level of 0.5 ng/mL, had a sensitivity of 13.0% and a specificity of 91.0%. SF-PCT, with a cut-off level of 5.0 ng/mL, had a sensitivity of 13.0% and a specificity of 52.0%. CONCLUSION: S-PCT and SF-PCT appeared to be no reliable biomarkers in the differential diagnosis of PJI from aseptic loosening in total joint arthroplasty.


Asunto(s)
Artritis Infecciosa/diagnóstico , Artritis Infecciosa/etiología , Artroplastia de Reemplazo/efectos adversos , Periodo Preoperatorio , Polipéptido alfa Relacionado con Calcitonina/sangre , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Adulto , Anciano , Anciano de 80 o más Años , Artritis Infecciosa/sangre , Artritis Infecciosa/cirugía , Biomarcadores/sangre , Femenino , Humanos , Prótesis Articulares/efectos adversos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/sangre , Infecciones Relacionadas con Prótesis/cirugía , Reoperación , Líquido Sinovial/química
7.
Int J Mol Sci ; 21(17)2020 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-32887518

RESUMEN

During total joint replacement, high concentrations of mesenchymal stromal cells (MSCs) are released at the implantation site. They can be found in cell-tissue composites (CTC) that are regularly removed by surgical suction. A surgical vacuum suction handle was filled with bone substitute granules, acting as a filter allowing us to harvest CTC. The purpose of this study was to investigate the osteopromotive potential of CTC trapped in the bone substitute filter material during surgical suction. In the course of 10 elective total hip and knee replacement surgeries, ß-tricalcium-phosphate (TCP) and cancellous allograft (Allo) were enriched with CTC by vacuum suction. Mononuclear cells (MNC) were isolated from the CTC and investigated towards cell proliferation and colony forming unit (CFU) formation. Furthermore, MSC surface markers, trilineage differentiation potential and the presence of defined cytokines were examined. Comparable amounts of MNC and CFUs were detected in both CTCs and characterized as MSC‱ of MNC with 9.8 ± 10.7‱ for the TCP and 12.8 ± 10.2‱ for the Allo (p = 0.550). CTCs in both filter materials contain cytokines for stimulation of cell proliferation and differentiation (EGF, PDGF-AA, angiogenin, osteopontin). CTC trapped in synthetic (TCP) and natural (Allo) bone substitute filters during surgical suction in the course of a joint replacement procedure include relevant numbers of MSCs and cytokines qualified for bone regeneration.


Asunto(s)
Regeneración Ósea , Diferenciación Celular , Proliferación Celular , Cerámica/química , Células Madre Mesenquimatosas/citología , Osteoartritis/cirugía , Andamios del Tejido/química , Anciano , Sustitutos de Huesos/química , Femenino , Humanos , Masculino , Osteoartritis/patología , Succión , Vacio
8.
Arch Orthop Trauma Surg ; 140(3): 331-341, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31501930

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) is a challenging option for the treatment of posttraumatic arthritis due to acetabular fractures. METHODS: The study aimed to determine the short- and mid-term clinical and radiographic results of THA following acetabular fracture. The fracture pattern, the extent of injury and the initial fracture treatment were considered to evaluate the influence of these factors on the clinical-radiographic outcome. RESULTS: 67 patients who received THA for the treatment of posttraumatic osteoarthritis after acetabular fracture between January 2007 and December 2012 were analyzed consecutively. The group consisted of 13 female (19%) and 54 male (81%) patients with a mean age of 59 (25-87) years at the time of THA. The time between acetabular injury and arthroplasty was 107 (1-504) months on average. The all-cause 8-year survival rate was 0.87% (0.76-0.93) and there were 8 revisions, half of them were due to aseptic loosening of the cup. The Harris Hip Score achieved was 75.7 ± 21.3 (26.9-100) points. Prior to THA, heterotopic ossifications were detected in 28% and after THA implantation in 42%. CONCLUSION: The decrease of the interval between injury and arthroplasty was associated with increasing patient age (p = 0.001) and surgical treatment of the acetabular fracture (p = 0.04). Complex fracture patterns were accompanied by acetabular bone defects more often than simple patterns (p = 0.03). Overall, arthroplasty due to posttraumatic osteoarthritis after acetabular fracture resulted in decreased overall survival rates and poorer clinical outcome as compared to primary arthroplasty.


Asunto(s)
Acetábulo , Artroplastia de Reemplazo de Cadera , Fracturas de Cadera , Acetábulo/diagnóstico por imagen , Acetábulo/lesiones , Acetábulo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/mortalidad , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Femenino , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/mortalidad , Fracturas de Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Osificación Heterotópica , Osteoartritis , Complicaciones Posoperatorias , Resultado del Tratamiento
9.
Arch Orthop Trauma Surg ; 140(12): 1859-1866, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32048017

RESUMEN

BACKGROUND: Progressive oxidation of highly cross-linked ultra-high molecular weight (UHMPWE-X) liners is considered to be a risk factor for material failure in THA. Antioxidants such as vitamin E (alpha-tocopherol) (UHMWPE-XE) were supplemented into the latest generation of polyethylene liners. To prevent inhomogenous vitamin E distribution within the polymer, blending was established as an alternative manufacturing process to diffusion. The purpose of the present study was to investigate the in vivo wear behavior of UHMWPE-XE in comparison with conventional UHMWPE-X liners using virtual CAD-based radiographs. METHODS: Until now, 94 patients from a prospective, randomized, controlled, multicenter study were reviewed at 5-year follow-up. Of these, 51 (54%) received UHMWPE-XE and 43 (46%) UHMWPE-X liners. Anteroposterior pelvic radiographs were made immediately after surgery and at 1 and 5 years postoperatively. The radiographs were analyzed using the observer-independent analysis software RayMatch® (Raylytic GmbH, Leipzig, Germany). RESULTS: The mean wear rate was measured to be 23.6 µm/year (SD 13.7; range 0.7-71.8 µm). There were no significant differences between the two cohorts (UHMWPE-X: 23.2 µm/year vs. UHMWPE-XE: 24.0 µm/year, p = 0.73). Cup anteversion significantly changed within the 1st year after implantation independent from the type of polyethylene liner [UHMWPE-X: 18.2-23.9° (p = 0.0001); UHMWPE-XE: 21.0-25.5° (p = 0.002)]. No further significant changes of cup anteversion in both groups were found between year 1 and 5 after implantation [UHMWPE-X (p = 0.46); UHMWPE-XE (p = 0.56)]. CONCLUSION: The present study demonstrates that the addition of vitamin E does not adversely affect the midterm wear behavior of UHMWPE-X. The antioxidative benefit of vitamin E is expected to become evident in long-term follow-up. Cup anteversion increment by 5° within the 1st year is likely a result of the released hip flexion contracture resulting in an enhanced posterior pelvic tilt. Therefore, a reassessment of target values in acetabular cup placement might be considered.


Asunto(s)
Antioxidantes , Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Polietilenos , Diseño de Prótesis , Vitamina E , Acetábulo/cirugía , Adulto , Anciano , Diseño Asistido por Computadora , Femenino , Estudios de Seguimiento , Alemania , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Falla de Prótesis , Radiografía
10.
Orthopade ; 49(6): 547-560, 2020 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-32399741

RESUMEN

Fractures and osteotomies are characterized by a structural discontinuity of the affected bone with formation of a gap. If bone healing does not lead to an osseous bridging of the fragments within a time period of 6 months a nonunion (pseudarthrosis) occurs. In this stage spontaneous bone healing is unlikely in the future without any intervention. Pseudarthrosis is classified into hypertrophic and atrophic types. Moreover, the differentiation between aseptic and septic conditions, the size of the defect, the local blood supply and the mechanical stability are crucial for treatment planning. The type of pseudarthrosis and the accompanying comorbidities can be classified in scoring systems and influence the selection of the treatment procedure. The operative principles aim at the vitalization of atrophic bone parts, achieving sufficient stabilization and cures the infection, whereas nonoperative measures are primarily supportive measures. The foundation of successful treatment is the minimization of individual risk profiles and sufficient patient compliance.


Asunto(s)
Fracturas Óseas/cirugía , Osteotomía , Seudoartrosis , Fijación Interna de Fracturas , Humanos , Cooperación del Paciente
11.
Orthopade ; 49(12): 1077-1085, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31696260

RESUMEN

BACKGROUND: Despite continuous technical improvements, polyethylene wear debris induced periprosthetic osteolysis remains the main cause for failure of hip arthroplasty. Progressive oxidation of polyethylene was identified as another risk factor for material failure. To overcome this problem, antioxidants such as vitamin E (alpha-tocopherol) were supplemented by diffusion into the latest generation of polyethylene liners. OBJECTIVE: The purpose of the present study was to investigate the clinical outcome of patients treated with vitamin E blended highly cross-linked ultra-high molecular weight polyethylene liners (UHMWPE-XE) in comparison with conventional UHMWPE­X liners by evaluating patient-reported outcome measures (PROM's) at 3­year follow-up. METHODS: A total of 143 patients were recruited into this prospective, randomized trial in our academic center. Three years after implantation, 101 patients were examined in the outpatient clinic for follow-up. Of these, 51 (50.5%) received UHMWPE-XE and 50 (49.5%) UHMWPE­X liners. Clinical outcome was evaluated using Harris-Hip-Score (HHS) UCLA-Score and Hip Disability and Osteoarthritis Outcome Score (HOOS). RESULTS: There was a significant improvement in all PROM's at one- and three-year follow-up compared to the status before implantation. PROM's did not differ significantly between the first and third year follow-up. Both liner groups showed an equal clinical outcome. CONCLUSION: The present study demonstrates that the supplementation of vitamin E to polyethylene liners is reliable and safe without showing higher complication rates compared with conventional polyethylene liners. The shortterm clinical outcome of vitamin E-blended (UHMWPE­XE) is equivalent to those of conventional highly cross-linked polyethylene liners.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Polietileno , Vitamina E , Estudios de Seguimiento , Humanos , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis
12.
BMC Evol Biol ; 19(1): 100, 2019 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-31077129

RESUMEN

BACKGROUND: Cellulose, a major polysaccharide of the plant cell wall, consists of ß-1,4-linked glucose moieties forming a molecular network recalcitrant to enzymatic breakdown. Although cellulose is potentially a rich source of energy, the ability to degrade it is rare in animals and was believed to be present only in cellulolytic microbes. Recently, it has become clear that some animals encode endogenous cellulases belonging to several glycoside hydrolase families (GHs), including GH45. GH45s are distributed patchily among the Metazoa and, in insects, are encoded only by the genomes of Phytophaga beetles. This study aims to understand both the enzymatic functions and the evolutionary history of GH45s in these beetles. RESULTS: To this end, we biochemically assessed the enzymatic activities of 37 GH45s derived from five species of Phytophaga beetles and discovered that beetle-derived GH45s degrade three different substrates: amorphous cellulose, xyloglucan and glucomannan. Our phylogenetic and gene structure analyses indicate that at least one gene encoding a putative cellulolytic GH45 was present in the last common ancestor of the Phytophaga, and that GH45 xyloglucanases evolved several times independently in these beetles. The most closely related clade to Phytophaga GH45s was composed of fungal sequences, suggesting this GH family was acquired by horizontal gene transfer from fungi. Besides the insects, other arthropod GH45s do not share a common origin and appear to have emerged at least three times independently. CONCLUSION: The rise of functional innovation from gene duplication events has been a fundamental process in the evolution of GH45s in Phytophaga beetles. Both, enzymatic activity and ancestral origin suggest that GH45s were likely an essential prerequisite for the adaptation allowing Phytophaga beetles to feed on plants.


Asunto(s)
Escarabajos/enzimología , Escarabajos/genética , Transferencia de Gen Horizontal , Glicósido Hidrolasas/genética , Familia de Multigenes , Secuencia de Aminoácidos , Animales , Biocatálisis , Evolución Molecular , Genes de Insecto , Glicósido Hidrolasas/química , Proteínas de Insectos/química , Proteínas de Insectos/genética , Filogenia
13.
Arch Orthop Trauma Surg ; 139(8): 1039-1044, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30725191

RESUMEN

INTRODUCTION: Latest trends in shoulder replacement aim at bone stock preservation. Long-term results of stemless anatomical total shoulder implants compare favourably with stemmed designs in terms of function and survivorship. The Total Evolutive Shoulder System (TESS) has been one of the first designs offering a stemless implant not only for anatomical but also for reverse total shoulder arthroplasty with optional short stem attachment in cases with poor bone quality. The aim of the present study was to evaluate long-term results of the reverse Total Evolutive Shoulder System (TESS). MATERIALS AND METHODS: Between 2006 and 2009, 49 shoulders in 47 patients were replaced using the Biomet reverse Total Evolutive Shoulder System (TESS). 29 shoulders in 27 patients who were aged 72.4 ± 6.7 (53-88) years were available for review at a mean follow-up of 101.6 ± 24.6 (75-142) months. RESULTS: The implant survival rate was 93.1% at 101 months (8.4 years). The overall revision rate of the TESS implant was 17.2%. No implant associated complications to the reverse corolla implant could be observed. All reverse corolla implants showed solid fixation at follow-up. Scapular notching was found in 72.3% of the shoulders. Clinical scores significantly improved at long-term follow-up (VAS from 7.5 ± 1.2 to 1.4 ± 1.5, p < 0.001; quick-DASH from 70.9 ± 12.0 to 28.9 ± 22.9, p < 0.001 and Constant score from 13.0 ± 3.7 to 60.5 ± 16.8, p < 0.001). CONCLUSIONS: In terms of clinical scores, radiographic loosening, complication rates and implant survivorship the reverse Total Evolutive Shoulder System provides results comparable to those of conventional stemmed reverse shoulder arthroplasty.


Asunto(s)
Artroplastía de Reemplazo de Hombro/instrumentación , Diseño de Prótesis , Articulación del Hombro/cirugía , Prótesis de Hombro , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/métodos , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Escala Visual Analógica
14.
Antibiotics (Basel) ; 13(4)2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38667022

RESUMEN

Implant loosening is a severe complication after total joint replacement. Here, differential diagnosis between septic and aseptic cases is crucial for further surgical treatment, but low-grade periprosthetic joint infections (PJIs) in particular remain a challenge. In this study, we analyzed the synovial fluid proteome of 21 patients undergoing revision surgery for septic (eight cases) or aseptic (thirteen cases) implant failure using LC-MS/MS to identify potential new biomarkers as future diagnostic tools. Staphylococci were found in four cases, Streptococci in two cases, Serratia marcescens and Cutibacterium acnes in one case. Proteomic analysis of the synovial fluid resulted in the identification of 515 different proteins based on at least two peptides. A statistical comparison revealed 37 differentially abundant proteins (p < 0.05), of which 17 proteins (46%) showed a higher abundance in the septic group. The proteins with the highest fold change included the known marker proteins c-reactive protein (7.57-fold) and the calprotectin components protein S100-A8 (4.41-fold) and protein S100-A9 (3.1-fold). However, the protein with the highest fold change was leucine-rich alpha-2-glycoprotein 1 (LRG1) (9.07-fold), a currently discussed new biomarker for inflammatory diseases. Elevated LRG1 levels could facilitate the diagnosis of PJI in the future, but their significance needs to be further investigated.

15.
Int J Sports Phys Ther ; V18(3): 746-757, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37425120

RESUMEN

Background: Return to sport testing is an established routine, especially for athletes who have ruptured their anterior cruciate ligament (ACL). Various tests are performed, often combined in test batteries, such as the Back-in-action (BIA) test battery. Unfortunately, pre-injury performance is often unknown, and only few athletes pass the high demands of these test batteries. Purpose: The aim of the study was to determine the performance of under 18 American football players on the BIA to establish pre-injury sport specific benchmarks for future RTS testing and to compare these values to data from an age-matched reference group. Methods: Fifty-three healthy male American football players underwent a functional assessment using the "Back-in-action" test battery evaluating agility, speed (Parkour-Jumps and Quick-Feet test), balance (using a PC based balance board), and power (Counter-Movement-Jump [CMJ]) as objective measures. Their results were compared with a previously tested reference group (RP) and within the american football players (AF) through three subgroups according to field playing position. Results: Overall, the American football (AF) athletes showed lower balance scores for both legs (AF: 3.71/3.57/3.61; RP: 3.4/3.2/3.2; p<0.002) compared to the reference population (RP). CMJ height and Quick-Feet results were not statistically different (p>0.05), Parkour-Jump times (AF: 8.18/ 8.13 sec.; RP: 5.9/5.9sec.; p<0.001) were significantly slower. Power output in all CMJ's (AF: 46.86/36.94/37.36 W/kg; RP: 43.2/29.5/29 W/kg; p<0.001) was significantly higher than the RP. Passing and running game involved players (G2 & G3) showed significantly better balance scores (G2+G3: 3.36/3.27/3.33; G1: 4.22/4.06/4.10; p<0.001), higher jump height (G2&G3: 38.87/24.02/24.96 cm; G1: 32.03/19.50/18.96 cm; p<0.001) and more watts/kg (G2&G3: 48.83/37.21/37.64 W/kg; G1: 43.95/36.88/36.53 W/kg; p<0.001) compared to blocking players like Linemen (G1) and to the age matched reference population (RP). Conclusion: Only 53% of the healthy athletes would have been cleared for sport using the BIA test criteria, which highlights the challenging passing criteria. Despite significantly greater power measurements, scores of balance and agility were poorer compared to the reference group, especially for linemen. These data may serve as sport and position specific reference for high school American football players, instead of using the non-specific reference group data. Study design: cross-sectional study. Level of evidence: IIb.

16.
Orthopadie (Heidelb) ; 51(12): 1023-1032, 2022 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-36307604

RESUMEN

Bone substitute materials have been successfully used for bone defects in orthopedics and trauma surgery for a long time; however, there are cases, especially in bone defects with a critical size, in which the treatment is complicated. Nowadays, multiple bone substitute materials are available. Autologous cancellous bone grafts remain the gold standard among the bone replacement materials; however, donor site morbidity and the limited availability of autologous cancellous bone represent restrictions for autologous bone grafting. Allogeneic cancellous bone grafts have also been successfully for years in the treatment of bone defects; however, infection rates of more than 10% have been described for the use of allogeneic cancellous bone. By introducing synthetic bone substitutes further alternatives are currently available to the user for the individual treatment of bone defects. The aim of this study is to demonstrate the advantages and disadvantages of various synthetic bone substitute materials.


Asunto(s)
Sustitutos de Huesos , Sustitutos de Huesos/uso terapéutico , Trasplante Óseo , Huesos , Trasplante Autólogo
17.
Sports Med Int Open ; 6(2): E60-E68, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36575730

RESUMEN

The return to sport after knee injury is challenging. This is burdensome for sports with a high incidence of injuries, such as team handball. Various tests guide decision making, but often the athlete's preinjury performance of these measures remains unknown. Moreover, objective return-to-sport criteria of a matching population are missing. The purpose of this study was to evaluate objective measures of knee capability in handball depending on players' age. Two hundred sixty-one handball players performed a functional test battery designed to evaluate knee capability after an anterior cruciate ligament injury: two- and one-legged stability analysis, jumps, speed tests, and agility assessments. For age-specific evaluation, athletes were divided into three age groups (16-19; 20-29;≥30 years). Male players showed differences in two and one-legged jumping height (p<0.02) as well as power per body weight (p<0.01) between age groups. Young female players reached better results in two-and one-legged stability. Besides the quick feet test, results of females did not differ between age groups. Functional knee stability in healthy handball players is partly influenced by age, and females show better results in stability and male athletes in power measurements. This aspect should be considered for return to sports testing and underlines the importance of performance measures in athletic testing.

18.
J Funct Biomater ; 13(2)2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-35466226

RESUMEN

Titanium implants are frequently applied to the bone in orthopedic and trauma surgery. Although these biomaterials are characterized by excellent implant survivorship and clinical outcomes, there are almost no data available on the initial protein layer binding to the implant surface in situ. This study aims to investigate the composition of the initial protein layer on endoprosthetic surfaces as a key initiating step in osseointegration. In patients qualified for total hip arthroplasty, the implants are inserted into the femoral canal, fixed and subsequently explanted after 2 and 5 min. The proteins adsorbed to the surface (the implant proteome) are analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). A statistical analysis of the proteins' alteration with longer incubation times reveals a slight change in their abundance according to the Vroman effect. The pathways involved in the extracellular matrix organization of bone, sterile inflammation and the beginning of an immunogenic response governed by neutrophils are significantly enriched based on the analysis of the implant proteome. Those are generally not changed with longer incubation times. In summary, proteins relevant for osseointegration are already adsorbed within 2 min in situ. A deeper understanding of the in situ protein-implant interactions in patients may contribute to optimizing implant surfaces in orthopedic and trauma surgery.

19.
Orthopadie (Heidelb) ; 51(12): 986-995, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36205756

RESUMEN

OBJECTIVE: Minimally invasive approaches are subject to controversy in orthopedic surgery. The aim of the current study was to compare the radiographic parameters between two minimally invasive approaches in total hip arthroplasty. MATERIAL AND METHODS: Between January 2018 and February 2019, the radiographic parameters of 80 patients undergoing total hip arthroplasty via minimally invasive approaches (DAA: n = 40; SuperPath® SP: n = 40) have been measured. The radiographic analysis was performed with digital software tool mediCad® (HECTEC™ GmbH, Landshut, Germany). RESULTS: Patients treated with DAA showed significantly higher inclination (SP: 39.7°â€¯± 7.3° vs. DAA: 44.7°â€¯± 5.3°) and significantly lower cup anteversion values (SP: 31.2°â€¯± 7.9° vs. DAA: 27. 5°â€¯± 5.3°, p < 0.001) than patients undergoing THA via SP postoperatively. The horizontal femoral offset was neither preoperatively nor postoperatively higher in DAA than in SP cohort (preoperative: p = 0.71, postoperative: p = 0.25) (preoperative: SP:37.2 mm ± 7.3 vs. DAA 38.2 mm ± 7.5; postoperative: SP: 38.0 mm ± 7.2 vs. DAA: 40.5 mm ± 7.0). At both times, the acetabular offset was significantly higher in DAA cohort than in SP cohort (preoperative: SP: 32.9 mm ± 5.9 vs. DAA: 36.8 mm ± 4.9; postoperative: SP: 28.9 mm ± 4.2 vs. DAA: 33.4 mm ± 3.8) (preoperative: 0.001; postoperative: p < 0.001). The vertical height was preoperatively and postoperatively not significantly higher in SP cohort than in DAA cohort (preoperative: SP: 16.1 mm ± 4.1 vs. DAA: 15.5 mm ± 4.9; postoperative: SP: 16.6 mm ± 4.6 vs. DAA: 16.1 mm ± 4.6) (preoperative: p = 0.77; postoperative: p = 0.58). The preoperatively existing leg length discrepancy of the affected leg could be compensated via surgery without showing significant differences between the two cohorts (preoperative: SP: -3.2 mm ± 5.4 vs. DAA: 1.9 mm ± 4.9; postoperative: SP: 1.5 mm ± 5.4 vs. DAA: 4.8 mm ± 5.6) (preoperative: p = 0.34; postoperative: p = 0.09). CONCLUSION: The current study demonstrates suitable cup positioning and stem alignment in the coronal plane using minimal-invasive approaches DAA and Superpath®.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios Retrospectivos , Radiografía , Acetábulo/cirugía
20.
Z Orthop Unfall ; 160(3): 299-306, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-33296945

RESUMEN

BACKGROUND: Due to the lack of specificity of conventional diagnostic tools, the prediction of periprosthetic joint infections (PJI) remains challenging. The purpose of this study was to evaluate the accuracy of synovial fluid neopterin, presepsin, and TNF-α as diagnostic parameters and to compare it to the biomarkers recommended in the 2018 definition of periprosthetic hip and knee infection. METHODS: Between August 2018 and July 2019, a prospective cohort study was conducted in 80 patients with painful hip, shoulder, and knee arthroplasty. In addition to medical history, clinical and laboratory data were gathered. PJI was diagnosed based on the 2018 definition of periprosthetic hip and knee infection. Synovial joint fluid was analyzed for biomarker measurement using standard quantitative enzyme immunoassay kits. RESULTS: Fifty-three patients (66%) were classified as the aseptic group and twenty-seven patients (34%) as the PJI group. The mean levels of synovial fluid neopterin were significantly higher (p < 0.01) in the PJI group than those in the aseptic group (aseptic 8.3 ± 6.9 vs. PJI 20.9 ± 21.4 nmol/L). The average values of synovial fluid TNF-α and presepsin were not significantly higher in the PJI group than those in the aseptic group (presepsin: aseptic 0.13 ± 0.19 vs. PJI 0.11 ± 0.32 ng/mL, p = 0.08; TNF-α: aseptic 6.6 ± 7.3 vs. PJI 46.3 ± 123.2 pg/mL, p = 0.17). Synovial fluid neopterin was 59% specific and 74% sensitive with a cut-off value of 7.2 nmol/L. The sensitivity and specificity of synovial fluid TNF-α were 63 and 51% with a cut-off value of 3.9 pg/mL. Synovial fluid presepsin was 51% specific and 29% sensitive with a cut-off value above 0.06 ng/mL. CONCLUSION: Synovial fluid neopterin appears to a reliable diagnostic marker for detection of PJI. In contrast, synovial fluid TNF-α and presepsin are not suitable to exclude or diagnose PJI.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Infecciones Relacionadas con Prótesis , Artritis Infecciosa/diagnóstico , Artritis Infecciosa/cirugía , Biomarcadores , Humanos , Receptores de Lipopolisacáridos , Neopterin , Fragmentos de Péptidos , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/cirugía , Sensibilidad y Especificidad , Líquido Sinovial , Factor de Necrosis Tumoral alfa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA