Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Opt Express ; 28(26): 38813-38821, 2020 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-33379441

RESUMEN

A novel configuration of a Fourier domain mode locked (FDML) laser based on silicon photonics platform is presented in this work that exploits the narrowband reflection spectrum of a photonic crystal (PhC) cavity resonator. Configured as a linear Fabry-Perot laser, forward biasing of a p-n junction on the PhC cavity allowed for thermal tuning of the spectrum. The modulation frequency applied to the reflector equalled the inverse roundtrip time of the long cavity resulting in stable FDML operation over the swept wavelength range. An interferometric phase measurement measured the sweeping instantaneous frequency of the laser. The silicon photonics platform has potential for very compact implementation, and the electro-optic modulation method opens the possibility of modulation speeds far beyond those of mechanical filters.

2.
Nanophotonics ; 11(18): 4183-4196, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36147699

RESUMEN

In this paper we show a novel design of high Q-factor silicon nitride (SiN) 1D photonic crystal (PhC) cavities side-coupled to curved waveguides, operating with both silica and air cladding. The engineering of the etched 1D PhC cavity sidewalls angle allows for high Q-factors over a wide range of upper cladding compositions, and the achievement of the highest calculated Q-factor for non-suspended asymmetric SiN PhC structures. We show the employment of these type of SiN PhC cavities in hybrid external cavity laser (HECL) configuration, with mode-hop free single mode laser operation over a broad range of injected currents (from 25 mA to 65 mA), milliwatts of power output (up to 9 mW) and side-mode suppression ratios in the range of 40 dB. We demonstrate the operation of these devices as compact and energy efficient optical sensors that respond to refractive index changes in the surrounding medium the measurement of sodium chloride (from 0% to 25%) and sucrose (from 0% to 25%) in aqueous solution. In HECL configuration, the RI sensor exhibits a 2 orders of magnitude improvement in detection limit compared to the passive microcavity. We also discuss the possibility for applying these devices as novel transducers for refractive index changes that are induced by analyte specific absorption of infrared radiation by the target analytes present in gas or liquid phase.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA