Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Curr Microbiol ; 81(7): 196, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38816509

RESUMEN

Antimicrobial susceptibility testing (AST) by disk diffusion provides an accurate image of bacterial growth, enabling the detection of culture purity, heterogeneous growth, and antibiotic interactions. However, this manual method is time-consuming and visual interpretation is prone to errors. To overcome these disadvantages, the Radian® In-Line Carousel (Copan, Brescia, Italy) was launched, which is a WASPLab® module dedicated to full automation of (pre)-analytical steps as well as interpretation of disk diffusion AST. However, until now, no evaluation of Radian® against manual disk diffusion has been performed. We assessed the categorical agreement (CA) between standardized disk diffusion (reference method) and Radian® using EUCAST 2021 breakpoints. We tested 135 non-duplicate strains, selected from the National EUCAST challenge panel, clinical strains, and external quality controls. The strains included Enterobacterales (n = 63), Enterococcus faecalis (n = 3), Enterococcus faecium (n = 10), Pseudomonas aeruginosa (n = 16), Staphylococcus aureus (n = 19), coagulase-negative staphylococci (n = 4), and Streptococcus spp. (n = 20). Furthermore, we explored antibiotic disk thermolability in the WASP Radian® carousel by testing 10 ATCC® strains up to 7 days. The observed CA was 95.3%, 96.3%, 93.8%, 97.3% and 98.0% for Enterobacterales, Enterococcus spp., P. aeruginosa, Staphylococcus spp. and Streptococcus spp., respectively, resulting in an acceptable overall CA for all groups. (Very) major error rates were ≤ 5% for all antibiotics. Antibiotic disk thermostability was confirmed up to 4 days in the WASP Radian® In-Line Carousel. The Radian® In-Line Carousel provides a fully automated solution for accurate disk diffusion AST, reducing workload and improving standardization and traceability. In addition, our study demonstrated the thermostability of antibiotic disks up to 4 days in the WASP Radian® In-Line Carousel.


Asunto(s)
Antibacterianos , Bacterias , Pruebas Antimicrobianas de Difusión por Disco , Antibacterianos/farmacología , Pruebas Antimicrobianas de Difusión por Disco/métodos , Pruebas Antimicrobianas de Difusión por Disco/normas , Bacterias/efectos de los fármacos , Humanos , Pruebas de Sensibilidad Microbiana/métodos , Automatización de Laboratorios
2.
Int J Lab Hematol ; 46(4): 657-664, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38421076

RESUMEN

OBJECTIVES: Hematopoietic stem cell transplantation (HSCT) is a potentially curative treatment for various diseases. The measurement of CD34+ cells is crucial to schedule the peripheral blood stem cell collection and assess the engraftment potential of the apheresis product. The AQUIOS STEM system has been introduced as a novel application on the AQUIOS CL, a fully automated flow cytometer, for the enumeration of CD34+ hematopoietic progenitor cells (HPCs) in accordance with the The International Society for Hematotherapy and Graft Engineering guidelines. This study aimed to assess the potential of the novel AQUIOS STEM system versus currently used systems including the FACSCanto-II and the FACS Lyric flow cytometer in a multicenter study. METHODS: A total of 91 samples were used for the validation of the AQUOIS STEM system, including an analytical performance evaluation by means of assessing precision, sample stability, intersample carryover, and linearity and a method comparison with the present FACS systems in use to assess analytical and clinical decision agreement. RESULTS: Results showed excellent precision, with coefficient of variations <15% for dedicated quality control material and patient samples. There was no significant carry over. The fresh apheresis samples were stable when stored overnight at room temperature and at 4°C. Analytical comparison with the current systems demonstrated good correlation in peripheral blood, and minimal, clinically neglectable systematic and proportional bias in fresh apheresis products but a low correlation coefficient in cryopreserved products. CONCLUSIONS: The STEM system on AQUIOS CL allows automated enumeration of CD34+ stem cells, demonstrating good analytical performance and promising overall outcomes in peripheral blood and fresh apheresis products.


Asunto(s)
Antígenos CD34 , Citometría de Flujo , Células Madre Hematopoyéticas , Humanos , Antígenos CD34/análisis , Citometría de Flujo/métodos , Células Madre Hematopoyéticas/citología , Trasplante de Células Madre Hematopoyéticas , Reproducibilidad de los Resultados , Eliminación de Componentes Sanguíneos/métodos
3.
Viruses ; 14(9)2022 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-36146659

RESUMEN

This case report describes a 60-year-old female patient suffering from systemic sclerosis, for which she received immunomodulatory drugs. Her first SARS-CoV-2-positive nasopharyngeal sample was obtained in the emergency department, on 31 January 2022. Whole genome sequencing confirmed infection with Omicron BA.1.1. Her hospital stay was long and punctuated by many complications, including admission to the intensive care unit. At the beginning of April 2022, she started complaining of increased coughing, for which another SARS-CoV-2 RT-qPCR test was performed. The latter nasopharyngeal swab showed a strongly positive result. To support the theory of healthcare-associated reinfection, whole genome sequencing was performed and confirmed reinfection with Omicron BA.2. Since this patient was one of ten positive cases in this particular ward, a hospital outbreak investigation was performed. Whole genome sequencing data were available for five of these ten patients and showed a cluster of four patients with ≤2 small nucleotide polymorphisms difference.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Atención a la Salud , Femenino , Humanos , Persona de Mediana Edad , Nucleótidos , Reinfección , SARS-CoV-2/genética
4.
Viruses ; 14(6)2022 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-35746728

RESUMEN

To mitigate the massive COVID-19 burden caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), several vaccination campaigns were initiated. We performed a single-center observational trial to monitor the mid- (3 months) and long-term (10 months) adaptive immune response and to document breakthrough infections (BTI) in healthcare workers (n = 84) upon BNT162b2 vaccination in a real-world setting. Firstly, serology was determined through immunoassays. Secondly, antibody functionality was analyzed via in vitro binding inhibition and pseudovirus neutralization and circulating receptor-binding domain (RBD)-specific B cells were assessed. Moreover, the induction of SARS-CoV-2-specific T cells was investigated by an interferon-γ release assay combined with flowcytometric profiling of activated CD4+ and CD8+ T cells. Within individuals that did not experience BTI (n = 62), vaccine-induced humoral and cellular immune responses were not correlated. Interestingly, waning over time was more pronounced within humoral compared to cellular immunity. In particular, 45 of these 62 subjects no longer displayed functional neutralization against the delta variant of concern (VoC) at long-term follow-up. Noteworthily, we reported a high incidence of symptomatic BTI cases (17.11%) caused by alpha and delta VoCs, although vaccine-induced immunity was only slightly reduced compared to subjects without BTI at mid-term follow-up.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Vacuna BNT162 , Bélgica , Linfocitos T CD8-positivos , COVID-19/epidemiología , COVID-19/prevención & control , Progresión de la Enfermedad , Estudios de Seguimiento , Personal de Salud , Humanos , Inmunidad Celular , Inmunidad Humoral , Incidencia , SARS-CoV-2/genética , Vacunación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA