Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Biomed Biotechnol ; 2004(3): 143-149, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15292580

RESUMEN

Human growth hormone (hGH) signal transduction initiates with a receptor dimerization in which one molecule binds to the receptor through sites 1 and 2. A sandwich enzyme-linked immunosorbent assay was developed for quantifying hGH molecules that present helix 4 from binding site 1. For this, horse anti-rhGH antibodies were eluted by an immunoaffinity column constituted by sepharose-rhGH. These antibodies were purified through a second column with synthetic peptide correspondent to hGH helix 4, immobilized to sepharose, and used as capture antibodies. Those that did not recognize synthetic peptide were used as a marker antibody. The working range was of 1.95 to 31.25 ng/mL of hGH. The intra-assay coefficient of variation (CV) was between 4.53% and 6.33%, while the interassay CV was between 6.00% and 8.27%. The recovery range was between 96.0% to 103.8%. There was no cross-reactivity with human prolactin. These features show that our assay is an efficient method for the determination of hGH.

2.
J Biomed Biotechnol ; 2006(5): 56087, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17489017

RESUMEN

Human placental (hPLAP) and germ cell (PLAP-like) alkaline phosphatases are polymorphic and heat-stable enzymes. This study was designed to develop specific immunoassays for quantifying hPLAP and PLAP-like enzyme activity (EA) in sera of cancer patients, pregnant women, or smokers. Polyclonal sheep anti-hPLAP antibodies were purified by affinity chromatography with whole hPLAP protein (ICA-PLAP assay) or a synthetic peptide (aa 57-71) of hPLAP (ICA-PEP assay); the working range was 0.1-11 U/L and cutoff value was 0.2 U/L EA for nonsmokers. The intra- and interassay coefficients of variation were 3.7%-6.5% (ICA-PLAP assay) and 9.0%-9.9% (ICA-PEP assay). An insignificant cross-reactivity was noted for high levels of unheated intestinal alkaline phosphatase in ICA-PEP assay. A positive correlation between the regression of tumor size and EA was noted in a child with embryonal carcinoma. It can be concluded that ICA-PEP assay is more specific than ICA-PLAP, which is still useful to detect other PLAP/PLAP-like phenotypes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA