Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Appl Radiat Isot ; 165: 109347, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32938536

RESUMEN

Radioguided surgery (RGS) is a medical practice which thanks to a radiopharmaceutical tracer and a probe allows the surgeon to identify tumor residuals up to a millimetric resolution in real-time. The employment of ß- emitters, instead of γ or ß+, reduces background from healthy tissues, administered activity to the patient, and medical exposure. In a previous work the possibility of using a CMOS Imager (Aptina MT9V011), initially designed for visible light imaging, to detect ß- from 90Y or 90Sr sources has been established. Because of its possible application as counting probe in RGS, the performances of MT9V011 in clinical-like conditions were studied.1 Through horizontal scans on a collimated 90Sr source of different sizes (1, 3, 5, 7 mm), we have determined relationships between scan fit parameters and the source dimension, namely A quadratic correlation and a linear dependency of, respectively, signal integrated over scan interval, and maximum signal against source diameter, are determined. Horizontal scan measurements on a source, interposing collimators of different size, aim to determine relationships or correlations between scan fit parameters and source dimension. A quadratic correlation and a linear dependency of, respectively, signal integrated over scan interval, and maximum signal against source diameter are determined. In order to get closer to clinical conditions, agar-agar phantoms containing 90Y with different dimensions and activities were prepared. A 90Y phantom is characterized by a central spot and a ring all around, for simulating both signal (tumor) and background (surrounding healthy tissue). The relationship found between scan maximum and 90Sr source diameter is then exploited to extract the concentration ratio between spot and external ring of the 90Y phantom. This observable, defined as the ratio between the tumor and the nearby healthy tissues uptake simulates the Tumor-to-Non-tumor Ratio (TNR). With the aim of evaluating the sensor's ability to discriminate signal from background relying on the significance parameter, a further 90Y phantom, featuring a well-known and clinical-like activity will mimic the signal only condition. This result is used to extrapolate to different source sizes, after having estimated the background for various TNR. The obtained significance values suggest that the MT9V011 sensor is capable of distinguishing a signal from an estimated background, depending on the interplay among TNR, acquisition time and tumor diameter.


Asunto(s)
Partículas beta , Neoplasias/cirugía , Radiofármacos/química , Cirugía Asistida por Computador/métodos , Estudios de Factibilidad , Humanos
2.
Sci Rep ; 4: 4401, 2014 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-24646766

RESUMEN

The background induced by the high penetration power of the radiation is the main limiting factor of the current radio-guided surgery (RGS). To partially mitigate it, a RGS with ß(+)-emitting radio-tracers has been suggested in literature. Here we propose the use of ß(-)-emitting radio-tracers and ß(-) probes and discuss the advantage of this method with respect to the previously explored ones: the electron low penetration power allows for simple and versatile probes and could extend RGS to tumours for which background originating from nearby healthy tissue makes probes less effective. We developed a ß(-) probe prototype and studied its performances on phantoms. By means of a detailed simulation we have also extrapolated the results to estimate the performances in a realistic case of meningioma, pathology which is going to be our first in-vivo test case. A good sensitivity to residuals down to 0.1 ml can be reached within 1 s with an administered activity smaller than those for PET-scans thus making the radiation exposure to medical personnel negligible.


Asunto(s)
Partículas beta , Electrones , Fantasmas de Imagen , Cirugía Asistida por Computador/instrumentación , Humanos , Neoplasias Meníngeas/patología , Neoplasias Meníngeas/cirugía , Meningioma/patología , Meningioma/cirugía , Sensibilidad y Especificidad , Cirugía Asistida por Computador/métodos , Microambiente Tumoral , Radioisótopos de Itrio
SELECCIÓN DE REFERENCIAS