Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Appl Ergon ; 117: 104223, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38219376

RESUMEN

Postpartum haemorrhage (PPH) is an obstetric emergency causing nearly one-quarter of maternal deaths worldwide, 99% of these in low-resource settings (LRSs). Uterine balloon tamponade (UBT) devices are a non-surgical treatment to stop PPH. In LRSs, low-cost versions of UBT devices are based on the condom balloon tamponade (CBT) technique, but their effectiveness is limited. This paper discusses the experimental study to assess the usability and performance of a medical device, BAMBI, designed as an alternative to current CBT devices. The testing phase involved medical and non-medical personnel and was focused on testing BAMBI's usability and effectiveness compared to a standard CBT solution. We collected measures of the execution time and the procedure outcome. Different training procedures were also compared. Results show a significant preference for the BAMBI device. Besides, medical and non-medical subjects reached comparable outcomes. This aspect is highly relevant in LRSs where the availability of medical personnel could be limited.


Asunto(s)
Muerte Materna , Hemorragia Posparto , Taponamiento Uterino con Balón , Embarazo , Femenino , Humanos , Hemorragia Posparto/prevención & control , Condones , Taponamiento Uterino con Balón/métodos , Personal de Salud
2.
Sci Rep ; 14(1): 10004, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693193

RESUMEN

The 3.1 target of the Sustainable Development Goals of the United Nations aims to reduce the global maternal mortality ratio to less than 70 maternal deaths per 100,000 live births by 2030. The last updates on this target show a significant stagnation in the data, thus reducing the chance of meeting it. What makes this negative result even more serious is that these maternal deaths could be avoided through prevention and the wider use of pharmacological strategies and devices to stop postpartum haemorrhage (PPH). PPH is the leading obstetric cause of maternal mortality in low- and middle-income countries (LMICs). Despite low-cost devices based on the uterine balloon tamponade (UBT) technique are already available, they are not safe enough to guarantee the complete stop of the bleeding. When effective, they are too expensive, especially for LMICs. To address this issue, this study presents the design, mechanical characterisation and technology assessment performed to validate a novel low-cost UBT kit, particularly a novel component, i.e., the connector, which guarantees the kit's effectiveness and represents the main novelty. Results proved the device's effectiveness in stopping PPH in a simulated scenario. Moreover, economic and manufacturing evaluations demonstrated its potential to be adopted in LMICs.


Asunto(s)
Países en Desarrollo , Mortalidad Materna , Hemorragia Posparto , Taponamiento Uterino con Balón , Humanos , Femenino , Taponamiento Uterino con Balón/economía , Taponamiento Uterino con Balón/métodos , Taponamiento Uterino con Balón/instrumentación , Hemorragia Posparto/terapia , Hemorragia Posparto/mortalidad , Hemorragia Posparto/prevención & control , Hemorragia Posparto/economía , Embarazo
3.
Sci Rep ; 12(1): 13509, 2022 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-35931722

RESUMEN

Each year 65% of young athletes and 25% of physically active adults suffer from at least one musculoskeletal injury that prevents them from continuing with physical activity, negatively influencing their physical and mental well-being. The treatment of musculoskeletal injuries with the adhesive elastic kinesiology tape (KT) decreases the recovery time. Patients can thus recommence physical exercise earlier. Here, a novel KT based on auxetic structures is proposed to simplify the application procedure and allow personalization. This novel KT exploits the form-fitting property of auxetics as well as their ability to simultaneously expand in two perpendicular directions when stretched. The auxetic contribution is tuned by optimizing the structure design using analytical equations and experimental measurements. A reentrant honeycomb topology is selected to demonstrate the validity of the proposed approach. Prototypes of auxetic KT to treat general elbow pains and muscle tenseness in the forearm are developed.


Asunto(s)
Atletas , Traumatismos en Atletas/psicología , Traumatismos en Atletas/terapia , Cinta Atlética , Quinesiología Aplicada/métodos , Sistema Musculoesquelético/lesiones , Adulto , Atletas/psicología , Traumatismos en Atletas/fisiopatología , Ejercicio Físico/fisiología , Antebrazo/fisiopatología , Humanos , Quinesiología Aplicada/educación , Heridas y Lesiones/fisiopatología , Heridas y Lesiones/psicología , Heridas y Lesiones/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA