Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Clin Med (Lond) ; 24(3): 100206, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38643826

RESUMEN

Obesity affects one in four people in the United Kingdom and costs the National Health Service (NHS) ∼£6.5 billion annually. The glucagon-like peptide-1 (GLP-1) receptor analogues, such as once-daily subcutaneous Liraglutide 3.0 mg (Saxenda®) and once-weekly subcutaneous Semaglutide 2.4 mg (Wegovy®), were approved by the National Institute of Health and Care Excellence (NICE) as a treatment for obesity and funded by the NHS for 2 years. Our local data shows that Saxenda is effective at reducing body weight and glycaemia in people with obesity and diabetes; however, the supply issues of GLP-1 receptor analogues have contributed to the unavailability of Saxenda and Wegovy in our service. Our patients are devastated that they cannot access NICE-approved GLP-1 receptor analogues for obesity. The 2-year GLP-1 receptor analogue treatment limit for obesity alongside a lack of funded NHS services and supply issues represent barriers to treatment for people living with obesity who have clear medical indications.


Asunto(s)
Obesidad , Medicina Estatal , Humanos , Obesidad/tratamiento farmacológico , Reino Unido , Receptor del Péptido 1 Similar al Glucagón/agonistas , Liraglutida/uso terapéutico , Péptidos Similares al Glucagón/uso terapéutico , Péptidos Similares al Glucagón/análogos & derivados , Péptidos Similares al Glucagón/administración & dosificación , Fármacos Antiobesidad/uso terapéutico
2.
Nat Commun ; 13(1): 907, 2022 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-35173150

RESUMEN

Population antibody surveillance helps track immune responses to COVID-19 vaccinations at scale, and identify host factors that may affect antibody production. We analyse data from 212,102 vaccinated individuals within the REACT-2 programme in England, which uses self-administered lateral flow antibody tests in sequential cross-sectional community samples; 71,923 (33.9%) received at least one dose of BNT162b2 vaccine and 139,067 (65.6%) received ChAdOx1. For both vaccines, antibody positivity peaks 4-5 weeks after first dose and then declines. At least 21 days after second dose of BNT162b2, close to 100% of respondents test positive, while for ChAdOx1, this is significantly reduced, particularly in the oldest age groups (72.7% [70.9-74.4] at ages 75 years and above). For both vaccines, antibody positivity decreases with age, and is higher in females and those with previous infection. Antibody positivity is lower in transplant recipients, obese individuals, smokers and those with specific comorbidities. These groups will benefit from additional vaccine doses.


Asunto(s)
Envejecimiento/inmunología , Anticuerpos Antivirales/sangre , Vacuna BNT162/inmunología , ChAdOx1 nCoV-19/inmunología , SARS-CoV-2/inmunología , Factores de Edad , Anciano , Formación de Anticuerpos/inmunología , COVID-19/epidemiología , COVID-19/prevención & control , Estudios Transversales , Inglaterra/epidemiología , Femenino , Humanos , Programas de Inmunización , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores Sexuales , Vacunación
3.
Wellcome Open Res ; 6: 358, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35673545

RESUMEN

Background: Lateral flow immunoassays (LFIAs) are able to achieve affordable, large scale antibody testing and provide rapid results without the support of central laboratories. As part of the development of the REACT programme extensive evaluation of LFIA performance was undertaken with individuals following natural infection. Here we assess the performance of the selected LFIA to detect antibody responses in individuals who have received at least one dose of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccine. Methods: This was a prospective diagnostic accuracy study. Sampling was carried out at renal outpatient clinic and healthcare worker testing sites at Imperial College London NHS Trust. Two cohorts of patients were recruited; the first was a cohort of 108 renal transplant patients attending clinic following two doses of SARS-CoV-2 vaccine, the second cohort comprised 40 healthcare workers attending for first SARS-CoV-2 vaccination and subsequent follow up. During the participants visit, finger-prick blood samples were analysed on LFIA device, while paired venous sampling was sent for serological assessment of antibodies to the spike protein (anti-S) antibodies. Anti-S IgG was detected using the Abbott Architect SARS-CoV-2 IgG Quant II CMIA. A total of 186 paired samples were collected. The accuracy of Fortress LFIA in detecting IgG antibodies to SARS-CoV-2 compared to anti-spike protein detection on Abbott Assay Results: The LFIA had an estimated sensitivity of 92.0% (114/124; 95% confidence interval [CI] 85.7% to 96.1%) and specificity of 93.6% (58/62; 95% CI 84.3% to 98.2%) using the Abbott assay as reference standard (using the threshold for positivity of 7.10 BAU/ml) Conclusions: Fortress LFIA performs well in the detection of antibody responses for intended purpose of population level surveillance but does not meet criteria for individual testing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA