Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Mikrochim Acta ; 191(3): 134, 2024 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-38353778

RESUMEN

Salivary pH serves as a valuable and useful diagnostic marker for periodontal disease, as it not only plays a critical role in disease prevention but also in its development. Typically, saliva sampling is collected by draining and spitting it into collection tubes or using swabs. In this study, we have developed a Point-of-Care (POC) device for in situ determination of oral pH without the need for complex instruments, relying solely on a smartphone as the detection device. Our system utilizes a non-toxic vegetable colourimetric indicator, immobilized on a chitosan membrane located on a disposable stick, enabling direct sampling within the buccal cavity. An ad hoc designed 3D-printed attachment is used to ensure accurate positioning and alignment of the stick, as well as isolation from external lighting conditions. A custom-developed smartphone application captures and automatically processes the image of the sensing membrane, providing the salivary pH results. After optimizing the cocktail composition, the developed sensors demonstrated the capacity to determine pH within a range of 5.4 to 8.1 with a remarkable precision of 0.6%, achieving a very short analysis time of just 1 min. A stability study conducted on the sensing membranes revealed a lifetime of 50 days. To validate the performance of our analytical device, we compared its results against those obtained from a calibrated pH-meter, using a group of individuals. The device exhibited an average error of 2.4% when compared with the pH-meter results, confirming its reliability and accuracy.


Asunto(s)
Quitosano , Teléfono Inteligente , Humanos , Sistemas de Atención de Punto , Reproducibilidad de los Resultados , Concentración de Iones de Hidrógeno
2.
Mikrochim Acta ; 187(7): 421, 2020 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-32617684

RESUMEN

A microfluidic paper-based analytical device integrating carbon dot (CDs) is fabricated and used for a fluorometric off-on assay of biothiols. Vinyl sulfone (VS) click immobilization of carbon dots (CDs) on paper was accomplished by a one-pot simplified protocol that uses divinyl sulfone (DVS) as a homobifunctional reagent. This reagent mediated both the click oxa-Michael addition to the hydroxyl groups of cellulose and ulterior covalent grafting of the resulting VS paper to NH2-functionalized CDs by means of click aza-Michael addition. The resulting cellulose nanocomposite was used to engineer an inexpensive and robust microfluidic paper-based analytical device (µPAD) that is used for a reaction-based off-on fluorometric assay of biothiols (GSH, Cys, and Hcy). The intrinsic blue fluorescence of CDs (with excitation/emission maxima at 365/450 nm) is turned off via the heavy atom effect of an introduced iodo group. Fluorescence is turned on again due to the displacement of iodine by reaction with a biothiol. The increase in fluorescence is related to the concentration over a wide range (1 to 200 µM for GSH and 5-200 µM for Cys and Hcy, respectively), and the assay exhibits a low detection limit (0.3 µM for GSH and Cys and 0.4 µM for Hcy). The method allows for rapid screening and can also be used in combination with a digital camera readout. Graphical abstract Schematic representation of a µPAD based on click immobilized carbon dots and used for a reaction-based fluorometric off-on assay of biothiols. The intrinsic blue fluorescence of carbon dots is turned off via the heavy atom effect of an introduced iodo group and turned on by the displacement of this atom by reaction with a biothiol.


Asunto(s)
Cisteína/orina , Glutatión/orina , Homocisteína/orina , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/métodos , Puntos Cuánticos/química , Carbono/química , Química Clic , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Papel , Espectrometría de Fluorescencia/métodos , Sulfonas/química
3.
Mikrochim Acta ; 185(1): 47, 2017 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-29594561

RESUMEN

This work presents a microfluidic paper-based analytical device (µPAD) for glucose determination using a supported metal-organic framework (MOF) acting as a peroxidase mimic. The catalytic action of glucose oxidase (GOx) on glucose causes the formation of H2O2, and the MOF causes the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H2O2 to form a blue-green product with an absorption peak at 650 nm in the detection zone. A digital camera and the iOS feature of a smartphone are used for the quantitation of glucose with the S coordinate of the HSV color space as the analytical parameter. Different factors such as the concentration of TMB, GOx and MOF, pH and buffer, sample volume, reaction time and reagent position in the µPAD were optimized. Under optimal conditions, the value for the S coordinate increases linearly up to 150 µmol·L-1 glucose concentrations, with a 2.5 µmol·L-1 detection limit. The µPAD remains stable for 21 days under conventional storage conditions. Such an enzyme mimetic-based assay to glucose determination using Fe-MIL-101 MOF implemented in a microfluidic paper-based device possesses advantages over enzyme-based assays in terms of costs, durability and stability compared to other existing glucose determination methods. The procedure was applied to the determination of glucose in (spiked) serum and urine. Graphical abstract Schematic representation of microfluidic paper-based analytical device using metal-organic framework as a peroxidase mimic for colorimetric glucose detection with digital camera or smartphone and iOS app readout.

4.
Anal Chem ; 88(10): 5331-7, 2016 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-27077212

RESUMEN

This paper presents a thread-based microfluidic device (µTAD) that includes ionophore extraction chemistry for the optical recognition of potassium. The device is 1.5 cm × 1.0 cm and includes a cotton thread to transport the aqueous sample via capillary wicking to a 5 mm-long detection area, where the recognition chemistry is deposited that reaches equilibrium in 60 s, changing its color between blue and magenta. A complete characterization of the cotton thread used as well as the sensing element has been carried out. The imaging of the µTAD with a digital camera and the extraction of the H coordinate of the HSV color space used as the analytical parameter make it possible to determine K(I) between 2.4 × 10(-5) and 0.95 M with a precision better than 1.3%.

5.
Anal Bioanal Chem ; 408(11): 3013-20, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26869344

RESUMEN

A portable reconfigurable platform for copper (Cu(II)) determination based on luminescent carbon dot (Cdots) quenching is described. The electronic setup consists of a light-emitting diode (LED) as the carbon dot optical exciter and a photodiode as a light-to-current converter integrated in the same instrument. Moreover, the overall analog conditioning is simply performed with one integrated solution, a field-programmable analog array (FPAA), which makes it possible to reconfigure the filter and gain stages in real time. This feature provides adaptability to use the platform as an analytical probe for carbon dots coming from different batches with some variations in luminescence characteristics. The calibration functions obtained that fit a modified Stern-Volmer equation were obtained using luminescence signals from Cdots quenching by Cu(II). The analytical applicability of the reconfigurable portable instrument for Cu(II) using Cdots has been successfully demonstrated in tap water analysis.


Asunto(s)
Carbono/química , Cobre/análisis , Luminiscencia , Estándares de Referencia , Difracción de Rayos X
6.
Sensors (Basel) ; 15(10): 26769-82, 2015 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-26506353

RESUMEN

This work presents the design, fabrication, and characterization of a printed radio frequency identification tag in the ultra-high frequency band with multiple sensing capabilities. This passive tag is directly screen printed on a cardboard box with the aim of monitoring the packaging conditions during the different stages of the supply chain. This tag includes a commercial force sensor and a printed opening detector. Hence, the force applied to the package can be measured as well as the opening of the box can be detected. The architecture presented is a passive single-chip RFID tag. An electronic switch has been implemented to be able to measure both sensor magnitudes in the same access without including a microcontroller or battery. Moreover, the chip used here integrates a temperature sensor and, therefore, this tag provides three different parameters in every reading.

7.
Biosensors (Basel) ; 13(2)2023 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-36832033

RESUMEN

Here, we propose a microfluidic paper-based analytical device (µPAD) implemented with a near-field communication (NFC) tag as a portable, simple and fast colorimetric method for glutathione (GSH) determination. The proposed method was based on the fact that Ag+ could oxidize 3,3',5,5'-tetramethylbenzidine (TMB) into oxidized blue TMB. Thus, the presence of GSH could cause the reduction of oxidized TMB, which resulted in a blue color fading. Based on this finding, we developed a method for the colorimetric determination of GSH using a smartphone. A µPAD implemented with the NFC tag allowed the harvesting of energy from a smartphone to activate the LED that allows the capture of a photograph of the µPAD by the smartphone. The integration between electronic interfaces into the hardware of digital image capture served as a means for quantitation. Importantly, this new method shows a low detection limit of 1.0 µM. Therefore, the most important features of this non-enzymatic method are high sensitivity and a simple, fast, portable and low-cost determination of GSH in just 20 min using a colorimetric signal.


Asunto(s)
Colorimetría , Glutatión , Colorimetría/métodos , Bencidinas , Teléfono Inteligente , Límite de Detección
8.
Anal Methods ; 15(42): 5683-5691, 2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37861715

RESUMEN

In the present work, we report the development of a novel cotton thread-based colorimetric sensor modified by carboxymethylcellulose (CMC) and cuprizone (CPZ) with smartphone detection and its application for the quantitative determination of cupric ions in water and cachaça. The cotton thread/smartphone detection-based colorimetric method is an easily affordable, low-cost technique which allows one to perform real-time and on-field determination analyses, especially with limited financial resources. The method involves the complexation of Cu(II) with CPZ, which causes a change in the coloration of the cotton thread from a shade of white to blue in the detection zone of the colorimetric sensor. The immobilization of CPZ on CMC in the cotton thread leads to the pre-concentration of Cu(II) via a complexation mechanism with colorimetric reaction. The application of the colorimetric sensor allows the quantification of copper in the range from 1 to 12 mg L-1, with a low limit of detection of 0.21 mg L-1. In addition, the recovery assays conducted in samples of water and cachaça resulted in recovery percentages ranging from 84.9% to 107%, which is indicative of a precise method. To validate the precision of the proposed colorimetric method, the values obtained from the quantification analysis were compared with those of the flame atomic absorption spectrometry and a good agreement at the 95% confidence level was obtained.

9.
Anal Methods ; 15(19): 2300-2308, 2023 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-37089039

RESUMEN

The present study reports, for the first time, the development and application of a highly efficient method based on digital imaging analysis for the simultaneous determination of Cu2+ and furfural in cachaça samples using a two-phase system and chemometrics tools. Furfural reacts with aniline in an acidic medium to form a Schiff base, which exhibits a pink color. On the other hand, Cu2+ reacts with cuprizone in a basic medium to form a blue complex. The two reactions were performed on a porcelain plate, and a smartphone was used to capture the colorimetric images. Partial least squares (PLS) regression was used to construct the prediction models for Cu2+ and furfural contents in cachaça samples. After finding the best PLS models, the ordered predictor selection (OPS) analysis was performed in order to select the most predictive variables. The method developed was found to be effective in estimating the amounts of Cu2+ and furfural in cachaça samples, with a mean absolute error of 0.2 mg L-1 for the Cu2+ model, and 0.3 mg per 100 mL of anhydrous alcohol for the furfural model. The method proposed in this study is simple and straightforward; it does not require complex technical knowledge and can be used by the producers themselves in the cachaça manufacturing process.

10.
Biosens Bioelectron ; 230: 115268, 2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37030262

RESUMEN

The COVID-19 pandemic has highlighted the need for innovative approaches to its diagnosis. Here we present CoVradar, a novel and simple colorimetric method that combines nucleic acid analysis with dynamic chemical labeling (DCL) technology and the Spin-Tube device to detect SARS-CoV-2 RNA in saliva samples. The assay includes a fragmentation step to increase the number of RNA templates for analysis, using abasic peptide nucleic acid probes (DGL probes) immobilized to nylon membranes in a specific dot pattern to capture RNA fragments. Duplexes are formed by labeling complementary RNA fragments with biotinylated SMART bases, which act as templates for DCL. Signals are generated by recognizing biotin with streptavidin alkaline phosphatase and incubating with a chromogenic substrate to produce a blue precipitate. CoVradar results are analysed by CoVreader, a smartphone-based image processing system that can display and interpret the blotch pattern. CoVradar and CoVreader provide a unique molecular assay capable of detecting SARS-CoV-2 viral RNA without the need for extraction, preamplification, or pre-labeling steps, offering advantages in terms of time (∼3 h/test), cost (∼€1/test manufacturing cost) and simplicity (does not require large equipment). This solution is also promising for developing assays for other infectious diseases.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Aplicaciones Móviles , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , ARN Viral/genética , ARN Viral/análisis , Pandemias , Técnicas Biosensibles/métodos , Teléfono Inteligente , Técnicas de Amplificación de Ácido Nucleico/métodos
11.
Sensors (Basel) ; 12(5): 6746-63, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22778668

RESUMEN

The aim of this work was the determination of pH with a sensor array-based optical portable instrument. This sensor array consists of eleven membranes with selective colour changes at different pH intervals. The method for the pH calculation is based on the implementation of artificial neural networks that use the responses of the membranes to generate a final pH value. A multi-objective algorithm was used to select the minimum number of sensing elements required to achieve an accurate pH determination from the neural network, and also to minimise the network size. This helps to minimise instrument and array development costs and save on microprocessor energy consumption. A set of artificial neural networks that fulfils these requirements is proposed using different combinations of the membranes in the sensor array, and is evaluated in terms of accuracy and reliability. In the end, the network including the response of the eleven membranes in the sensor was selected for validation in the instrument prototype because of its high accuracy. The performance of the instrument was evaluated by measuring the pH of a large set of real samples, showing that high precision can be obtained in the full range.

12.
ACS Sens ; 7(1): 37-43, 2022 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-35020353

RESUMEN

Here we present a new approach for the development of fluoride chemosensors taking advantage of aggregation induced emission (AIE) properties. Although AIE-based chemosensors have been described, they rely primarily on the analyte causing aggregation and hence fluorescence. We propose a new concept in the use of AIE for the development of fluorescent sensors. Our hypothesis is based on the fact that a turn-off chemosensor in solution can be transformed into turn-on in the solid state if the properties of ACQ and AIE are properly combined between the fluorescent molecules involved. To demonstrate this hypothesis, we have selected a fluorescent chemosensor for the fluoride anion with a conjugated structure of bis(styryl)pyrimidine that, while showing turn-off behavior in solution, becomes turn-on when it is brought to the solid state. We have also combined it with the advantages of a detection system based on the microfluidic paper-based analytical devices (µPAD). The system is fully characterized spectroscopically both in solution and in the solid state, and quantum mechanical calculations were performed to explain how the sensor works. The prepared device presents a high sensitivity, with no interference and with an LoD and LoQ that allow determination of fluoride concentrations in water 2 orders of magnitude below the maximum allowed by WHO.


Asunto(s)
Colorantes Fluorescentes , Fluoruros , Aniones , Colorantes Fluorescentes/química , Agua/química
13.
Analyst ; 136(19): 3917-26, 2011 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-21818486

RESUMEN

The feasibility and performance of a procedure to evaluate previously developed one-shot optical sensors as single and selective analyte sensors for potassium, magnesium and hardness are presented. The procedure uses a conventional colour digital photographic camera as the detection system for simultaneous multianalyte detection. A 6.0 megapixel camera was used, and the procedure describes how it is possible to quantify potassium, magnesium and hardness simultaneously from the images captured, using multianalyte one-shot sensors based on ionophore-chromoionophore chemistry, employing the colour information computed from a defined region of interest on the sensing membrane. One of the colour channels in the red, green, blue (RGB) colour space is used to build the analytical parameter, the effective degree of protonation (1-α(eff)), in good agreement with the theoretical model. The linearization of the sigmoidal response function increases the limit of detection (LOD) and analytical range in all cases studied. The increases were from 5.4 × 10(-6) to 2.7 × 10(-7) M for potassium, from 1.4 × 10(-4) to 2.0 × 10(-6) M for magnesium and from 1.7 to 2.0 × 10(-2) mg L(-1) of CaCO(3) for hardness. The method's precision was determined in terms of the relative standard deviation (RSD%) which was from 2.4 to 7.6 for potassium, from 6.8 to 7.8 for magnesium and from 4.3 to 7.8 for hardness. The procedure was applied to the simultaneous determination of potassium, magnesium and hardness using multianalyte one-shot sensors in different types of waters and beverages in order to cover the entire application range, statistically validating the results against atomic absorption spectrometry as the reference procedure. Accordingly, this paper is an attempt to demonstrate the possibility of using a conventional digital camera as an analytical device to measure this type of one-shot sensor based on ionophore-chromoionophore chemistry instead of using conventional lab instrumentation.

14.
Sci Rep ; 11(1): 3947, 2021 02 17.
Artículo en Inglés | MEDLINE | ID: mdl-33597607

RESUMEN

Encapsulation of magnetic nanoparticles (MNPs) of iron (II, III) oxide (Fe3O4) with a thermopolymeric shell of a crosslinked poly(2-(2-methoxyethoxy)ethyl methacrylate) P(MEO2MA) is successfully developed. Magnetic aggregates of large size, around 150-200 nm are obtained during the functionalization of the iron oxide NPs with vinyl groups by using 3-butenoic acid in the presence of a water soluble azo-initiator and a surfactant, at 70 °C. These polymerizable groups provide a covalent attachment of the P(MEO2MA) shell on the surface of the MNPs while a crosslinked network is achieved by including tetraethylene glycol dimethacrylate in the precipitation polymerization synthesis. Temperature control is used to modulate the swelling-to-collapse transition volume until a maximum of around 21:1 ratio between the expanded: shrunk states (from 364 to 144 nm in diameter) between 9 and 49 °C. The hybrid Fe3O4@P(MEO2MA) microgel exhibits a lower critical solution temperature of 21.9 °C below the corresponding value for P(MEO2MA) (bulk, 26 °C). The MEO2MA coating performance in the hybrid microgel is characterized by dynamic light scattering and transmission electron microscopy. The content of preformed MNPs [up to 30.2 (wt%) vs. microgel] was established by thermogravimetric analysis while magnetic properties by vibrating sample magnetometry.

15.
Spectrochim Acta A Mol Biomol Spectrosc ; 253: 119580, 2021 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-33618261

RESUMEN

In this work we propose for the first time, a paper-based test strip to analyse Cu2+ content in sugar cane spirits, which, due to its simplicity, high portability and fast analytical response (3 min), can be easily applied to in situ analyses by producers. The test strip was developed aiming: i) identify qualitatively the Cu2+ content in sugar cane spirits, and, ii) determine quantitatively the Cu2+ content using a digital image method employing a smartphone. The paper-based test strip was functionalized with cuprizone and optimized through a Box-Behnken, an experimental design for obtaining the best reaction conditions. Based on qualitative method with naked eyes approach performed by six volunteers analyst untrained, the method present a percentage of accuracy of 93%. For the quantitative analysis, it was determined the metal content at a level of statistical agreement with the reference method, as well as it was obtained the dynamic linear range from 2 to 13 mg L-1 with limits of detection and quantification of 0.034 and 0.103 mg L-1, respectively. Furthermore, the quantitative method showed a reliable precision with an RSD of 4.3% (n = 10) and the recovery of Cu2+ ranged from 80 to 103.8%.


Asunto(s)
Saccharum , Bebidas Alcohólicas/análisis , Cuprizona , Grano Comestible , Humanos , Teléfono Inteligente
16.
Talanta ; 216: 120985, 2020 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-32456894

RESUMEN

In this work, a freshness colorimetric sensor has been integrated with pork meat packages. The sensor tracks rising CO2 levels in the package associated with meat spoilage, as CO2 levels increase with bacterial population. The color of the sensor changes depending on the quantity of bacteria present, therefore it can be correlated with the freshness of meat, in this case pork loin. Detection is achieved by a simple photograph using a smartphone, and analyzing the grey scale from the RGB space color with a custom made app. Only 2 µL of the cocktail (all components are nontoxic) is needed to prepare the sensor, which have been integrated inside meat packages using a variety of support materials prior to sealing. The Smartphone measurements have been validated using a reference method (Checkpoint Analyzer) and the results suggest it can provide the basis for a quick test of the quality of the packaged pork.


Asunto(s)
Colorimetría , Carne/análisis , Teléfono Inteligente , Animales , Embalaje de Alimentos , Carne/microbiología , Porcinos
17.
Nanomaterials (Basel) ; 10(12)2020 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-33297413

RESUMEN

This work presents an innovative application of carbon dots (Cdots) nanoparticles as sensing layer for relative humidity detection. The developed sensor is based on interdigitated capacitive electrodes screen printed on a flexible transparent polyethylene terephthalate (PET) film. Cdots are deposited on top of these electrodes. An exhaustive characterization of the nanoparticles has been conducted along with the fabrication of the sensor structure. The accompanied experiments give all the sensibility to the Cdots, showing its dependence with temperature and exciting frequency. To the best of our knowledge, this work paves the path to the use of these kind of nanoparticles in printed flexible capacitive sensors aimed to be employed in the continuously expanding Internet of Things ecosystem.

18.
Nanomaterials (Basel) ; 10(5)2020 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-32357422

RESUMEN

A portable reconfigurable platform for hemoglobin determination based on inner filter quenching of room-temperature phosphorescent carbon dots (CDs) in the presence of H2O2 is described. The electronic setup consists of a light-emitting diode (LED) as the carbon dot optical exciter and a photodiode as a light-to-current converter integrated in the same instrument. The reconfigurable feature provides adaptability to use the platform as an analytical probe for CDs coming from different batches with some variations in luminescence characteristics. The variables of the reaction were optimized, such as pH, concentration of reagents, and response time; as well as the variables of the portable device, such as LED voltage, photodiode sensitivity, and adjustment of the measuring range by a reconfigurable electronic system. The portable device allowed the determination of hemoglobin with good sensitivity, with a detection limit of 6.2 nM and range up to 125 nM.

19.
Nanoscale ; 12(16): 9178-9185, 2020 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-32297891

RESUMEN

Chromophore-appended cyclodextrins combine the supramolecular loading capabilities of cyclodextrins (CDs) with the optical properties of the affixed chromophores. Among fluorescent materials, carbon dots (CNDs) are attractive and the feasibility of CND-appended CDs as sensors has been demonstrated by different authors. However, CNDs are intrinsically heterogeneous materials and their ulterior functionalization yields hybrid composites that are not well defined in terms of structure and composition. Inspired by the fluorescence properties of 5-oxo-1,2,3,5-tetrahydroimidazo[1,2-a]pyridine-7-carboxylic acid (IPCA), the most paradigmatic of the molecular fluorophores detected in CNDs, herein we report two highly efficient synthetic chemical strategies for the preparation of IPCA-appended CDs that behave as CND-based CD "turn off-on" biosensors suitable for the analysis of cholesterol and ß-galactosidase activity. We have deconstructed the CND-CD systems to demonstrate that (i) the role of CNDs is limited to acting as a support for the molecular fluorophores produced during their synthesis and (ii) the molecular fluorophores suffice for the determination of the enzymatic activity based on the quenching by p-nitrophenol as a sacrificial quencher.


Asunto(s)
Técnicas Biosensibles , Carbono/química , Ciclodextrinas/química , Puntos Cuánticos , Colesterol/sangre , Fluorescencia , Colorantes Fluorescentes/química , Humanos , Nitrofenoles/química , beta-Galactosidasa/análisis
20.
Sensors (Basel) ; 9(10): 7694-710, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-22408475

RESUMEN

A hand-held luminometer for measuring electrochemiluminescence (ECL) for lactate determination and based on one-shot biosensors fabricated using screen-printed electrodes is described. The lactate recognition system is based on lactate oxidase and the transduction system consists of electro-oxidation of luminol, with all the reagents immobilized in a Methocel membrane. The membrane composition and reaction conditions have been optimized to obtain adequate sensitivity. The luminometer is based on a large silicon photodiode as detector and includes a programmable potentiostat to initialize the chemical reaction and signal processing circuitry, designed to acquire a low level photocurrent with offset cancelation, low pass filtering for noise attenuation and adjustable gain up to 10(12) V/A. The one-shot biosensor responds to lactate rapidly, with an acquisition time of 2.5 min, obtaining a linear dependence from 8 × 10(-6) to 2 × 10(-4) M, a detection limit of 2.4 × 10(-6) M and a sensor-to-sensor reproducibility (relative standard deviation, RSD) of around 7-10 % at the medium level of the range.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA