Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Environ Sci Technol ; 55(21): 14968-14978, 2021 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-34644501

RESUMEN

We report a new, autonomous Lab-on-Chip (LOC) microfluidic pH sensor with a 6000 m depth capability, ten times the depth capability of the state of the art autonomous spectrophotometric sensor. The pH is determined spectrophotometrically using purified meta-Cresol Purple indicator dye offering high precision (<0.001 pH unit measurement reproducibility), high frequency (every 8 min) measurements on the total proton scale from the surface to the deep ocean (to 600 bar). The sensor requires low power (3 W during continuous operation or ∼1300 J per measurement) and low reagent volume (∼3 µL per measurement) and generates small waste volume (∼2 mL per measurement) which can be retained during deployments. The performance of the LOC pH sensor was demonstrated on fixed and moving platforms over varying environmental salinity, temperature, and pressure conditions. Measurement accuracy was +0.003 ± 0.022 pH units (n = 47) by comparison with validation seawater sample measurements in coastal waters. The combined standard uncertainty of the sensor in situ pHT measurements was estimated to be ≤0.009 pH units at pH 8.5, ≤ 0.010 pH units at pH 8.0, and ≤0.014 pH units at pH 7.5. Integrated on autonomous platforms, this novel sensor opens new frontiers for pH observations, especially within the largest and most understudied ecosystem on the planet, the deep ocean.


Asunto(s)
Ecosistema , Agua de Mar , Concentración de Iones de Hidrógeno , Reproducibilidad de los Resultados , Espectrofotometría
2.
Environ Sci Technol ; 51(17): 9989-9995, 2017 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-28771345

RESUMEN

Here, we present a new in situ microfluidic phosphate sensor that features an improved "phosphate blue" assay which includes polyvinylpyrrolidone in place of traditional surfactants-improving sensitivity and reducing temperature effects. The sensor features greater power economy and analytical performance relative to commercially available alternatives, with a mean power consumption of 1.8 W, a detection limit of 40 nM, a dynamic range of 0.14-10 µM, and an infield accuracy of 4 ± 4.5%. During field testing, the sensor was continuously deployed for 9 weeks in a chalk stream, revealing complex relations between flow rates and phosphate concentration that suggest changing dominance in phosphate sources. A distinct diel phosphorus signal was observed under low flow conditions, highlighting the ability of the sensor to decouple geochemical and biotic effects on phosphate dynamics in fluvial environments. This paper highlights the importance of high resolution in situ sensors in addressing the current gross under-sampling of aquatic environments.


Asunto(s)
Dispositivos Laboratorio en un Chip , Fosfatos/análisis , Bioensayo , Monitoreo del Ambiente , Límite de Detección , Microfluídica , Fósforo
3.
Philos Trans A Math Phys Eng Sci ; 374(2059)2016 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-26667920

RESUMEN

It is 4 years since the subglacial lake community published its plans for accessing, sampling, measuring and studying the pristine, and hitherto enigmatic and very different, Antarctic subglacial lakes, Vostok, Whillans and Ellsworth. This paper summarizes the contrasting probe technologies designed for each of these subglacial environments and briefly updates how these designs changed or were used differently when compared to previously published plans. A detailed update on the final engineering design and technical aspects of the probe for Subglacial Lake Ellsworth is presented. This probe is designed for clean access, is negatively buoyant (350 kg), 5.2 m long, 200 mm in diameter, approximately cylindrical and consists of five major units: (i) an upper power and communications unit attached to an optical and electrical conducting tether, (ii)-(iv) three water and particle samplers, and (v) a sensors, imaging and instrumentation pack tipped with a miniature sediment corer. To date, only in Subglacial Lake Whillans have instruments been successfully deployed. Probe technologies for Subglacial Lake Vostok (2014/15) and Lake Ellsworth (2012/13) were not deployed for technical reasons, in the case of Lake Ellsworth because hot-water drilling was unable to access the lake during the field season window. Lessons learned and opportunities for probe technologies in future subglacial access missions are discussed.

4.
Environ Sci Technol ; 46(17): 9548-56, 2012 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-22835223

RESUMEN

Microfluidic technology permits the miniaturization of chemical analytical methods that are traditionally undertaken using benchtop equipment in the laboratory environment. When applied to environmental monitoring, these "lab-on-chip" systems could allow high-performance chemical analysis methods to be performed in situ over distributed sensor networks with large numbers of measurement nodes. Here we present the first of a new generation of microfluidic chemical analysis systems with sufficient analytical performance and robustness for deployment in natural waters. The system detects nitrate and nitrite (up to 350 µM, 21.7 mg/L as NO(3)(-)) with a limit of detection (LOD) of 0.025 µM for nitrate (0.0016 mg/L as NO(3)(-)) and 0.02 µM for nitrite (0.00092 mg/L as NO(2)(-)). This performance is suitable for almost all natural waters (apart from the oligotrophic open ocean), and the device was deployed in an estuarine environment (Southampton Water) to monitor nitrate+nitrite concentrations in waters of varying salinity. The system was able to track changes in the nitrate-salinity relationship of estuarine waters due to increased river flow after a period of high rainfall. Laboratory characterization and deployment data are presented, demonstrating the ability of the system to acquire data with high temporal resolution.


Asunto(s)
Monitoreo del Ambiente/instrumentación , Dispositivos Laboratorio en un Chip , Nitratos/análisis , Nitritos/análisis , Ríos/química , Contaminantes Químicos del Agua/análisis , Diseño de Equipo , Límite de Detección
5.
ACS Sens ; 7(1): 89-98, 2022 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-35020365

RESUMEN

Microfluidic reagent-based nutrient sensors offer a promising technology to address the global undersampling of ocean chemistry but have so far not been shown to operate in the deep sea (>200 m). We report a new family of miniaturized lab-on-chip (LOC) colorimetric analyzers making in situ nitrate and phosphate measurements from the surface ocean to the deep sea (>4800 m). This new technology gives users a new low-cost, high-performance tool for measuring chemistry in hyperbaric environments. Using a combination of laboratory verification and field-based tests, we demonstrate that the analyzers are capable of in situ measurements during profiling that are comparable to laboratory-based analyses. The sensors feature a novel and efficient inertial-flow mixer that increases the mixing efficiency and reduces the back pressure and flushing time compared to a previously used serpentine mixing channel. Four separate replicate units of the nitrate and phosphate sensor were calibrated in the laboratory and showed an average limit of detection of 0.03 µM for nitrate and 0.016 µM for phosphate. Three on-chip optical absorption cell lengths provide a large linear range (to >750 µM (10.5 mg/L-N) for nitrate and >15 µM (0.47 mg/L-P) for phosphate), making the instruments suitable for typical concentrations in both ocean and freshwater aquatic environments. The LOC systems automatically collected a series of deep-sea nitrate and phosphate profiles in the northeast Atlantic while attached to a conductivity temperature depth (CTD) rosette, and the LOC nitrate sensor was attached to a PROVOR profiling float to conduct automated nitrate profiles in the Mediterranean Sea.


Asunto(s)
Microfluídica , Nitratos , Nitratos/análisis , Nutrientes , Fosfatos/análisis , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA