Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
AJR Am J Roentgenol ; 223(1): e2431042, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38717239

RESUMEN

BACKGROUND. Concern may exist that pulmonary lesions associated with cystic airspaces are at risk of increased biopsy complications or lower biopsy accuracy given challenges in targeting tissue abutting or intermingled with the cystic airspaces. OBJECTIVE. The purpose of this study was to evaluate the safety and diagnostic performance of CT-guided core needle biopsy (CNB) of pulmonary lesions associated with cystic airspaces. METHODS. This retrospective study included 90 patients (median age, 69.5 years; 28 women, 62 men) who underwent CT-guided CNB of pulmonary lesions associated with cystic airspaces (based on review of procedural images) from February 2010 to December 2022 and a matched control group (2:1 ratio) of 180 patients (median age, 68.0 years; 56 women, 124 men) who underwent CNB of noncystic noncavitary lesions during the same period. The groups were compared in terms of complications, nondiagnostic biopsies (i.e., nonspecific benignities, atypical cells, or insufficient specimens), and CNB diagnostic performance for detecting malignancy using as reference the final diagnosis from a joint review of all available records. For lesions associated with cystic airspaces that underwent surgical resection after CNB, histologic slides were reviewed to explore the nature of the cystic airspace. RESULTS. The final diagnosis was malignant in 90% (81/90) of lesions associated with cystic airspaces and 92% (165/180) of noncystic noncavitary lesions. Patients with lesions associated with cystic airspaces and patients with noncystic noncavitary lesions showed no significant difference in frequency of complications (overall: 40% [36/90] vs 38% [68/180], p = .79; major: 4% [4/90] vs 6% [10/180], p = .78; minor: 36% [32/90] vs 32% [58/180], p = .59), frequency of nondiagnostic biopsies (12% [11/90] vs 9% [16/180], p = .40), or diagnostic performance (accuracy: 94% [85/90] vs 97% [175/180], p = .50; sensitivity: 94% [76/81] vs 97% [160/165], p = .50; specificity: 100% [9/9] vs 100% [15/15]; p > .99), respectively. All false-negative results for malignancy in both groups occurred in patients with nondiagnostic CNB results. Among lesions associated with cystic airspaces that were resected after CNB (all malignant), the cystic airspaces most commonly represented tumor degeneration (22/31 [71%]). CONCLUSION. CT-guided CNB is safe and accurate for assessing pulmonary lesions associated with cystic airspaces. CLINICAL IMPACT. CNB may help avoid a missed or delayed cancer diagnosis in pulmonary lesions with cystic airspaces.


Asunto(s)
Biopsia Guiada por Imagen , Neoplasias Pulmonares , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Anciano , Biopsia Guiada por Imagen/métodos , Biopsia Guiada por Imagen/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Estudios de Casos y Controles , Biopsia con Aguja Gruesa/métodos , Biopsia con Aguja Gruesa/efectos adversos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/diagnóstico por imagen , Persona de Mediana Edad , Quistes/diagnóstico por imagen , Quistes/patología , Enfermedades Pulmonares/patología , Enfermedades Pulmonares/diagnóstico por imagen , Radiografía Intervencional/métodos , Anciano de 80 o más Años , Adulto , Pulmón/patología , Pulmón/diagnóstico por imagen
2.
Eur Radiol ; 33(9): 6009-6019, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37017703

RESUMEN

OBJECTIVES: Beyond total kidney and cyst volume (TCV), non-cystic tissue plays an important role in autosomal dominant polycystic kidney disease (ADPKD) progression. This study aims at presenting and preliminarily validating a diffusion MRI (DWI)-based TCV quantification method and providing evidence of DWI potential in characterising non-cystic tissue microstructure. METHODS: T2-weighted MRI and DWI scans (b = 0, 15, 50, 100, 200, 350, 500, 700, 1000; 3 directions) were acquired from 35 ADPKD patients with CKD stage 1 to 3a and 15 healthy volunteers on a 1.5 T scanner. ADPKD classification was performed using the Mayo model. DWI scans were processed by mono- and segmented bi-exponential models. TCV was quantified on T2-weighted MRI by the reference semi-automatic method and automatically computed by thresholding the pure diffusivity (D) histogram. The agreement between reference and DWI-based TCV values and the differences in DWI-based parameters between healthy and ADPKD tissue components were assessed. RESULTS: There was strong correlation between DWI-based and reference TCV (rho = 0.994, p < 0.001). Non-cystic ADPKD tissue had significantly higher D, and lower pseudo-diffusion and flowing fraction than healthy tissue (p < 0.001). Moreover, apparent diffusion coefficient and D values significantly differed by Mayo imaging class, both in the whole kidney (Wilcoxon p = 0.007 and p = 0.004) and non-cystic tissue (p = 0.024 and p = 0.007). CONCLUSIONS: DWI shows potential in ADPKD to quantify TCV and characterise non-cystic kidney tissue microstructure, indicating the presence of microcysts and peritubular interstitial fibrosis. DWI could complement existing biomarkers for non-invasively staging, monitoring, and predicting ADPKD progression and evaluating the impact of novel therapies, possibly targeting damaged non-cystic tissue besides cyst expansion. CLINICAL RELEVANCE STATEMENT: This study shows diffusion-weighted MRI (DWI) potential to quantify total cyst volume and characterise non-cystic kidney tissue microstructure in ADPKD. DWI could complement existing biomarkers for non-invasively staging, monitoring, and predicting ADPKD progression and evaluating the impact of novel therapies, possibly targeting damaged non-cystic tissue besides cyst expansion. KEY POINTS: • Diffusion magnetic resonance imaging shows potential to quantify total cyst volume in ADPKD. • Diffusion magnetic resonance imaging might allow to non-invasively characterise non-cystic kidney tissue microstructure. • Diffusion magnetic resonance imaging-based biomarkers significantly differ by Mayo imaging class, suggesting their possible prognostic value.


Asunto(s)
Quistes , Riñón Poliquístico Autosómico Dominante , Humanos , Riñón Poliquístico Autosómico Dominante/diagnóstico por imagen , Riñón Poliquístico Autosómico Dominante/patología , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Riñón/diagnóstico por imagen , Riñón/patología , Biomarcadores , Quistes/diagnóstico por imagen , Quistes/patología
3.
J Magn Reson Imaging ; 55(2): 323-335, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33140551

RESUMEN

BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE: Systematic consensus process using a modified Delphi method. POPULATION: Not applicable. SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts. RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Riñón , Imagen por Resonancia Magnética , Consenso , Técnica Delphi , Humanos , Estudios Multicéntricos como Asunto , Circulación Renal
4.
Kidney Int ; 100(5): 1001-1011, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33984338

RESUMEN

Over the past few years, clinical renal imaging has seen great advances, allowing assessments of kidney structure and morphology, perfusion, function and metabolism, and oxygenation, as well as microstructure and the interstitium. Medical imaging is becoming increasingly important in the evaluation of kidney physiology and pathophysiology, showing promise in management of patients with renal disease, in particular with regard to diagnosis, classification, and prediction of disease development and progression, monitoring response to therapy, detection of drug toxicity, and patient selection for clinical trials. A variety of imaging modalities, ranging from routine to advanced tools, are currently available to probe the kidney both spatially and temporally, particularly ultrasonography, computed tomography, positron emission tomography, renal scintigraphy, and multiparametric magnetic resonance imaging. Given that the range is broad and varied, kidney imaging techniques should be chosen based on the clinical question and the specific underlying pathologic mechanism, taking into account contraindications and possible adverse effects. Integration of various modalities providing complementary information will likely provide the greatest insight into renal pathophysiology. This review aims to highlight major recent advances in key tools that are currently available or potentially relevant for clinical kidney imaging, with a focus on non-oncological applications. The review also outlines the context of use, limitations, and advantages of various techniques, and highlights gaps to be filled with future development and clinical adoption.


Asunto(s)
Riñón , Imagen por Resonancia Magnética , Humanos , Riñón/diagnóstico por imagen , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Ultrasonografía
5.
Eur Radiol ; 31(4): 1999-2012, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33033861

RESUMEN

OBJECTIVES: To evaluate the inter-rater agreement of chest X-ray (CXR) findings in coronavirus disease 2019 (COVID-19) and to determine the value of initial CXR along with demographic, clinical, and laboratory data at emergency department (ED) presentation for predicting mortality and the need for ventilatory support. METHODS: A total of 340 COVID-19 patients who underwent CXR in the ED setting (March 1-13, 2020) were retrospectively included. Two reviewers independently assessed CXR abnormalities, including ground-glass opacities (GGOs) and consolidation. Two scoring systems (Brixia score and percentage of lung involvement) were applied. Inter-rater agreement was assessed by weighted Cohen's kappa (κ) or intraclass correlation coefficient (ICC). Predictors of death and respiratory support were identified by logistic or Poisson regression. RESULTS: GGO admixed with consolidation (n = 235, 69%) was the most common CXR finding. The inter-rater agreement was almost perfect for type of parenchymal opacity (κ = 0.90), Brixia score (ICC = 0.91), and percentage of lung involvement (ICC = 0.95). The Brixia score (OR: 1.19; 95% CI: 1.06, 1.34; p = 0.003), age (OR: 1.16; 95% CI: 1.11, 1.22; p < 0.001), PaO2/FiO2 ratio (OR: 0.99; 95% CI: 0.98, 1; p = 0.002), and cardiovascular diseases (OR: 3.21; 95% CI: 1.28, 8.39; p = 0.014) predicted death. Percentage of lung involvement (OR: 1.02; 95% CI: 1.01, 1.03; p = 0.001) and PaO2/FiO2 ratio (OR: 0.99; 95% CI: 0.99, 1.00; p < 0.001) were significant predictors of the need for ventilatory support. CONCLUSIONS: CXR is a reproducible tool for assessing COVID-19 and integrates with patient history, PaO2/FiO2 ratio, and SpO2 values to early predict mortality and the need for ventilatory support. KEY POINTS: • Chest X-ray is a reproducible tool for assessing COVID-19 pneumonia. • The Brixia score and percentage of lung involvement on chest X-ray integrate with patient history, PaO2/FIO2 ratio, and SpO2 values to early predict mortality and the need for ventilatory support in COVID-19 patients presenting to the emergency department.


Asunto(s)
COVID-19 , Servicio de Urgencia en Hospital , Humanos , Pulmón , Radiografía Torácica , Estudios Retrospectivos , SARS-CoV-2 , Rayos X
6.
Eur Radiol ; 31(8): 6001-6012, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33492473

RESUMEN

Existing quantitative imaging biomarkers (QIBs) are associated with known biological tissue characteristics and follow a well-understood path of technical, biological and clinical validation before incorporation into clinical trials. In radiomics, novel data-driven processes extract numerous visually imperceptible statistical features from the imaging data with no a priori assumptions on their correlation with biological processes. The selection of relevant features (radiomic signature) and incorporation into clinical trials therefore requires additional considerations to ensure meaningful imaging endpoints. Also, the number of radiomic features tested means that power calculations would result in sample sizes impossible to achieve within clinical trials. This article examines how the process of standardising and validating data-driven imaging biomarkers differs from those based on biological associations. Radiomic signatures are best developed initially on datasets that represent diversity of acquisition protocols as well as diversity of disease and of normal findings, rather than within clinical trials with standardised and optimised protocols as this would risk the selection of radiomic features being linked to the imaging process rather than the pathology. Normalisation through discretisation and feature harmonisation are essential pre-processing steps. Biological correlation may be performed after the technical and clinical validity of a radiomic signature is established, but is not mandatory. Feature selection may be part of discovery within a radiomics-specific trial or represent exploratory endpoints within an established trial; a previously validated radiomic signature may even be used as a primary/secondary endpoint, particularly if associations are demonstrated with specific biological processes and pathways being targeted within clinical trials. KEY POINTS: • Data-driven processes like radiomics risk false discoveries due to high-dimensionality of the dataset compared to sample size, making adequate diversity of the data, cross-validation and external validation essential to mitigate the risks of spurious associations and overfitting. • Use of radiomic signatures within clinical trials requires multistep standardisation of image acquisition, image analysis and data mining processes. • Biological correlation may be established after clinical validation but is not mandatory.


Asunto(s)
Radiología , Tomografía Computarizada por Rayos X , Biomarcadores , Consenso , Humanos , Procesamiento de Imagen Asistido por Computador
7.
Headache ; 60(9): 1920-1929, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32654136

RESUMEN

OBJECTIVE: To examine the factor structure of the Headache Triggers Sensitivity and Avoidance Questionnaire (HTSAQ) and its German version (HTSAQ-G), in order to identify potential different types of triggers. Furthermore, a short form of the questionnaire was developed. BACKGROUND: The HTSAQ includes 24 of the most commonly reported headache triggers (eg, stress, odors, lack of sleep). Both the HTSAQ and HTSAQ-G appeared to be reliable and valid measures of sensitivity to and avoidance of headache triggers. METHODS: In a cross-country collaboration, data from 2 cross-sectional studies including N = 391 individuals diagnosed with migraine from Australia (n = 222) and Germany (n = 169) were analyzed. The factor structure of the questionnaire was examined using exploratory and confirmatory factor analysis. Finally, a short form of the HTSAQ was constructed and evaluated regarding psychometric properties. RESULTS: Factor analytic results showed a differentiation between internal and external headache triggers, and different patterns of strategies in coping with triggers. The scales of both the original questionnaire as well as the developed short form showed good reliability (Cronbach's α = 0.76 to 0.96). As expected, negative correlations (r = -0.10 to -0.30, P = .006 to .044) with acceptance of pain were observed. Participants with chronic migraine showed significantly higher triggers sensitivity and avoidance of triggers than those with episodic migraine (t(389) = -9.12, P < .001, Cohens d = 0.93). CONCLUSIONS: Both the long and short forms of the questionnaire appear to be reliable and valid measures. The development of the short form of the questionnaire simplifies the use of the HTSAQ in clinical practice. Further research should focus on other primary headache disorders, such as tension-type headache or cluster headache.


Asunto(s)
Trastornos Migrañosos/etiología , Psicometría/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Australia , Estudios Transversales , Análisis Factorial , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Psicometría/métodos , Psicometría/normas , Adulto Joven
8.
MAGMA ; 33(1): 3-21, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31422518

RESUMEN

OBJECTIVE: Phase-contrast magnetic resonance imaging (PC-MRI) is a non-invasive method used to compute blood flow velocity and volume. This systematic review aims to discuss the current status of renal PC-MRI and provide practical recommendations which could inform future clinical studies and its adoption in clinical practice. METHODOLOGY: A comprehensive search of all the PC-MRI studies in human healthy subjects or patients related to the kidneys was performed. RESULTS: A total of 39 studies were included in which PC-MRI was used to measure renal blood flow (RBF) alongside other derivative hemodynamic parameters. PC-MRI generally showed good correlation with gold standard methods of RBF measurement, both in vitro and in vivo, and good reproducibility. Despite PC-MRI not being routinely used in clinical practice, there are several clinical studies showing its potential to support diagnosis and monitoring of renal diseases, in particular renovascular disease, chronic kidney disease and autosomal dominant polycystic kidney disease. DISCUSSION: Renal PC-MRI shows promise as a non-invasive technique to reliably measure RBF, both in healthy volunteers and in patients with renal disease. Future multicentric studies are needed to provide definitive normative ranges and to demonstrate the clinical potential of PC-MRI, likely as part of a multi-parametric renal MRI protocol.


Asunto(s)
Riñón/irrigación sanguínea , Riñón/diagnóstico por imagen , Riñón/patología , Imagen por Resonancia Magnética , Adulto , Anciano , Velocidad del Flujo Sanguíneo , Medios de Contraste , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Perfusión , Enfermedades Renales Poliquísticas/diagnóstico por imagen , Enfermedades Renales Poliquísticas/patología , Obstrucción de la Arteria Renal , Circulación Renal , Reproducibilidad de los Resultados
9.
MAGMA ; 33(5): 747, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32529448

RESUMEN

The article Phase­contrast magnetic resonance imaging to assess renal perfusion: a systematic review and statement paper, written by Giulia Villa, Steffen Ringgaard, Ingo Hermann, Rebecca Noble, Paolo Brambilla, Dinah S. Khatir, Frank G. Zöllner, Susan T. Francis, Nicholas M. Selby, Andrea Remuzzi and Anna Caroli, was originally published electronically on the publisher's internet portal on 17 August 2019 without open access.

10.
MAGMA ; 33(1): 131-140, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31628564

RESUMEN

PURPOSE: The potential of renal MRI biomarkers has been increasingly recognised, but clinical translation requires more standardisation. The PARENCHIMA consensus project aims to develop and apply a process for generating technical recommendations on renal MRI. METHODS: A task force was formed in July 2018 focused on five methods. A draft process for attaining consensus was distributed publicly for consultation and finalised at an open meeting (Prague, October 2018). Four expert panels completed surveys between October 2018 and March 2019, discussed results and refined the surveys at a face-to-face meeting (Aarhus, March 2019) and completed a second round (May 2019). RESULTS: A seven-stage process was defined: (1) formation of expert panels; (2) definition of the context of use; (3) literature review; (4) collection and comparison of MRI protocols; (5) consensus generation by an approximate Delphi method; (6) reporting of results in vendor-neutral and vendor-specific terms; (7) ongoing review and updating. Application of the process resulted in 166 consensus statements. CONCLUSION: The process generated meaningful technical recommendations across very different MRI methods, while allowing for improvement and refinement as open issues are resolved. The results are likely to be widely supported by the renal MRI community and thereby promote more harmonisation.


Asunto(s)
Riñón/diagnóstico por imagen , Imagen por Resonancia Magnética/normas , Nefrología/normas , Investigación Biomédica Traslacional/normas , Biomarcadores/metabolismo , Consenso , Técnica Delphi , Europa (Continente) , Testimonio de Experto , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/tendencias , Nefrología/tendencias , Estándares de Referencia , Encuestas y Cuestionarios , Investigación Biomédica Traslacional/tendencias , Estados Unidos
11.
MAGMA ; 33(1): 177-195, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31676990

RESUMEN

OBJECTIVES: Standardization is an important milestone in the validation of DWI-based parameters as imaging biomarkers for renal disease. Here, we propose technical recommendations on three variants of renal DWI, monoexponential DWI, IVIM and DTI, as well as associated MRI biomarkers (ADC, D, D*, f, FA and MD) to aid ongoing international efforts on methodological harmonization. MATERIALS AND METHODS: Reported DWI biomarkers from 194 prior renal DWI studies were extracted and Pearson correlations between diffusion biomarkers and protocol parameters were computed. Based on the literature review, surveys were designed for the consensus building. Survey data were collected via Delphi consensus process on renal DWI preparation, acquisition, analysis, and reporting. Consensus was defined as ≥ 75% agreement. RESULTS: Correlations were observed between reported diffusion biomarkers and protocol parameters. Out of 87 survey questions, 57 achieved consensus resolution, while many of the remaining questions were resolved by preference (65-74% agreement). Summary of the literature and survey data as well as recommendations for the preparation, acquisition, processing and reporting of renal DWI were provided. DISCUSSION: The consensus-based technical recommendations for renal DWI aim to facilitate inter-site harmonization and increase clinical impact of the technique on a larger scale by setting a framework for acquisition protocols for future renal DWI studies. We anticipate an iterative process with continuous updating of the recommendations according to progress in the field.


Asunto(s)
Biomarcadores/metabolismo , Imagen de Difusión por Resonancia Magnética , Riñón/diagnóstico por imagen , Investigación Biomédica Traslacional , Algoritmos , Consenso , Técnica Delphi , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Riñón/metabolismo , Modelos Estadísticos , Movimiento (Física) , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
13.
Med Lav ; 111(3): 195-202, 2020 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-32624561

RESUMEN

BACKGROUND: A growing literature has revealed a relationship between shift-work, including night-shift, and the disturbance of sleep-wake cycle, leading to insomnia and/or increased daytime sleepiness in shift nurses; recent findings showed an association between shift work sleep disorders and distress, work accidents, decreased job performance and, consequently, lower quality of health service provision and lower standards of care. OBJECTIVES: To analyze across the gender how shift nurses experience shift work sleep disorders and job stress. METHODS: A cross-sectional study was performed following the STROBE Statement. The Italian version of the Job Content Questionnaire, the Bergen Insomnia Scale and the Epworth Sleepiness Scale were administered to the registered nurses employed in three Departments of General Practice and Elderly Care Medicine. RESULTS: No significant association was found between high job strain and insomnia and daytime sleepiness. Significantly more women than men experienced high job strain, insomnia and daytime sleepiness; among women the level of social support was significantly and negatively associated with insomnia and daytime sleepiness. CONCLUSIONS: The findings of this study suggest that interventions aimed to prevent shift work sleep disorder and job stress in shift-nurses should incorporate the assessment of social support across the gender. Moreover, longitudinal studies are required to evaluate the effectiveness of interventions targeted on social support to minimize the occurrence of insomnia and daytime sleepiness in shift nurses.


Asunto(s)
Enfermeras y Enfermeros , Estrés Laboral , Trastornos del Sueño del Ritmo Circadiano , Estrés Psicológico , Tolerancia al Trabajo Programado , Adulto , Estudios Transversales , Femenino , Humanos , Italia , Masculino , Enfermeras y Enfermeros/psicología , Encuestas y Cuestionarios
14.
PLoS Med ; 16(4): e1002777, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30951521

RESUMEN

BACKGROUND: Autosomal dominant polycystic kidney disease (ADPKD) is the most frequent genetically determined renal disease. In affected patients, renal function may progressively decline up to end-stage renal disease (ESRD), and approximately 10% of those with ESRD are affected by ADPKD. The somatostatin analog octreotide long-acting release (octreotide-LAR) slows renal function deterioration in patients in early stages of the disease. We evaluated the renoprotective effect of octreotide-LAR in ADPKD patients at high risk of ESRD because of later-stage ADPKD. METHODS AND FINDINGS: We did an internally funded, parallel-group, double-blind, placebo-controlled phase III trial to assess octreotide-LAR in adults with ADPKD with glomerular filtration rate (GFR) 15-40 ml/min/1.73 m2. Participants were randomized to receive 2 intramuscular injections of 20 mg octreotide-LAR (n = 51) or 0.9% sodium chloride solution (placebo; n = 49) every 28 days for 3 years. Central randomization was 1:1 using a computerized list stratified by center and presence or absence of diabetes or proteinuria. Co-primary short- and long-term outcomes were 1-year total kidney volume (TKV) (computed tomography scan) growth and 3-year GFR (iohexol plasma clearance) decline. Analyses were by modified intention-to-treat. Patients were recruited from 4 Italian nephrology units between October 11, 2011, and March 20, 2014, and followed up to April 14, 2017. Baseline characteristics were similar between groups. Compared to placebo, octreotide-LAR reduced median (95% CI) TKV growth from baseline by 96.8 (10.8 to 182.7) ml at 1 year (p = 0.027) and 422.6 (150.3 to 695.0) ml at 3 years (p = 0.002). Reduction in the median (95% CI) rate of GFR decline (0.56 [-0.63 to 1.75] ml/min/1.73 m2 per year) was not significant (p = 0.295). TKV analyses were adjusted for age, sex, and baseline TKV. Over a median (IQR) 36 (24 to 37) months of follow-up, 9 patients on octreotide-LAR and 21 patients on placebo progressed to a doubling of serum creatinine or ESRD (composite endpoint) (hazard ratio [HR] [95% CI] adjusted for age, sex, baseline serum creatinine, and baseline TKV: 0.307 [0.127 to 0.742], p = 0.009). One composite endpoint was prevented for every 4 treated patients. Among 63 patients with chronic kidney disease (CKD) stage 4, 3 on octreotide-LAR and 8 on placebo progressed to ESRD (adjusted HR [95% CI]: 0.121 [0.017 to 0.866], p = 0.036). Three patients on placebo had a serious renal cyst rupture/infection and 1 patient had a serious urinary tract infection/obstruction, versus 1 patient on octreotide-LAR with a serious renal cyst infection. The main study limitation was the small sample size. CONCLUSIONS: In this study we observed that in later-stage ADPKD, octreotide-LAR slowed kidney growth and delayed progression to ESRD, in particular in CKD stage 4. TRIAL REGISTRATION: ClinicalTrials.gov NCT01377246; EudraCT: 2011-000138-12.


Asunto(s)
Fallo Renal Crónico/tratamiento farmacológico , Octreótido/administración & dosificación , Riñón Poliquístico Autosómico Dominante/tratamiento farmacológico , Adulto , Preparaciones de Acción Retardada , Progresión de la Enfermedad , Método Doble Ciego , Femenino , Tasa de Filtración Glomerular/efectos de los fármacos , Humanos , Inyecciones Intramusculares , Riñón/efectos de los fármacos , Riñón/patología , Fallo Renal Crónico/etiología , Fallo Renal Crónico/patología , Masculino , Persona de Mediana Edad , Octreótido/efectos adversos , Riñón Poliquístico Autosómico Dominante/complicaciones , Riñón Poliquístico Autosómico Dominante/patología , Resultado del Tratamiento
15.
Radiology ; 290(3): 769-782, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30599104

RESUMEN

Kidney cysts can manifest as focal disease (simple and complex kidney cysts), affect a whole kidney (eg, multicystic dysplastic kidney or cystic dysplasia), or manifest as bilateral cystic disease (eg, autosomal recessive polycystic kidney disease [ARPKD] or autosomal dominant polycystic kidney disease [ADPKD]). In children, as opposed to adults, a larger proportion of kidney cysts are due to genetic diseases (eg, HNF1B nephropathy, various ciliopathies, and tuberous sclerosis complex), and fewer patients have simple cysts or acquired cystic kidney disease. The purpose of this consensus statement is to provide clinical guidance on standardization of imaging tests to evaluate kidney cysts in children. A committee of international experts in pediatric nephrology, pediatric radiology, pediatric US, and adult nephrology prepared systematic literature reviews and formulated recommendations at a consensus meeting. The final statement was endorsed by the European Society of Pediatric Radiology, the European Federation of Societies for Ultrasound in Medicine and Biology, the European Society of Pediatric Nephrology, and reviewed by the European Reference Network for Rare Kidney Diseases. Main recommendations are as follows: US is the method of choice when assessing pediatric kidney cysts, with selected indications for MRI and contrast-enhanced US. CT should be avoided whenever possible because of ionizing radiation. Renal US yields essential diagnostic information in many cases. In patients with ARPKD or other ciliopathies, abdominal US is needed for diagnosis and screening of portal hypertension. US is usually sufficient for follow-up kidney imaging, but MRI can be valuable for clinical trials in patients with ADPKD or in older children with tuberous sclerosis complex to evaluate both kidney cysts and angiomyolipomas.


Asunto(s)
Diagnóstico por Imagen/normas , Enfermedades Renales Quísticas/diagnóstico por imagen , Niño , Consenso , Europa (Continente) , Humanos
16.
Avian Pathol ; 48(sup1): S35-S43, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31362523

RESUMEN

Dermanyssus gallinae (De Geer, 1778) is a major problem for the poultry industry worldwide, as it negatively affects virtually all kinds of rearing systems. Therefore, the control of infestation has become a routine process, and its economic cost is constantly increasing. Until now, most of the control strategies have relied on the use of synthetic chemical drugs, but their efficacy is often questioned by the emergence and diffusion of resistant mite populations. With this in mind, the efficacy of λ-cyhalothrin, amitraz, and phoxim has been verified by testing them against 86 mite populations collected from the same number of poultry farms in Italy from 2008 to 2015. Assays were performed according to the filter paper method using the recommended, half, quarter, double and quadruple doses. The results showed that phoxim and amitraz were the most effective acaricides (median efficacies 80.35% and 80.83%, respectively), but amitraz exhibited a sharp fall in its efficacy during 2011 and 2012, while phoxim maintained its high effectiveness up to 2015, when it dropped. The overall median efficacy of λ-cyhalothrin was 58.33%. The data also highlighted the importance of the use of the right concentration, as an increase in dosage was not always useful against resistant populations, while its reduction also diminished efficacy, simultaneously increasing the risk for the development of resistance.


Asunto(s)
Acaricidas/farmacología , Infestaciones por Ácaros/veterinaria , Ácaros/efectos de los fármacos , Enfermedades de las Aves de Corral/tratamiento farmacológico , Animales , Italia , Infestaciones por Ácaros/tratamiento farmacológico , Infestaciones por Ácaros/parasitología , Nitrilos/farmacología , Compuestos Organotiofosforados/farmacología , Aves de Corral , Enfermedades de las Aves de Corral/parasitología , Piretrinas/farmacología , Encuestas y Cuestionarios , Toluidinas/farmacología
17.
Med Lav ; 110(4): 285-292, 2019 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-31475690

RESUMEN

BACKGROUND: Shift work including night shifts is generally associated with chronic misalignment between the endogenous circadian timing system and behavior cycles, leading to metabolic disorders including metabolic syndrome (MS). OBJECTIVES: The purpose of this research was to analyze the latest developments in assessing and managing the occupational risk of MS in shift-healthcare workers (HCWs). METHODS: According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement, the authors used MEDLINE/Pubmed to perform a systematic review of literature from January 2008 to December 2018.  Results: Six studies were selected; the topics, discussed in order of frequency from highest to lowest, were: risk assessment, occurrence rates, and risk management. The main occupational determinants for MS were the cumulative shift work including night shifts and the number of nights worked per month per worker. With regard to cumulative lifetime exposure to shift work, the findings of our review suggest a dose-response relationship between increasing years of shift work history and MS in shift-HCWs. CONCLUSIONS: The findings suggest the need to better investigate the impact of sleep deprivation in the assessment of MS risk in shift-HCWs and clarify the role of such variables as confounders, mediators, or effect modifiers. Moreover, to date the data regarding management interventions focused on the risk of MS are inconsistent and therefore a special effort is required to detect strategic ways to minimize the likelihood of MS occurring in shift-HCWs.


Asunto(s)
Ritmo Circadiano , Personal de Salud , Síndrome Metabólico , Tolerancia al Trabajo Programado , Humanos , Medición de Riesgo
19.
Nephrol Dial Transplant ; 33(suppl_2): ii22-ii28, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-30137579

RESUMEN

Tissue hypoxia plays a key role in the development and progression of many kidney diseases. Blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) is the most promising imaging technique to monitor renal tissue oxygenation in humans. BOLD-MRI measures renal tissue deoxyhaemoglobin levels voxel by voxel. Increases in its outcome measure R2* (transverse relaxation rate expressed as per second) correspond to higher deoxyhaemoglobin concentrations and suggest lower oxygenation, whereas decreases in R2* indicate higher oxygenation. BOLD-MRI has been validated against micropuncture techniques in animals. Its reproducibility has been demonstrated in humans, provided that physiological and technical conditions are standardized. BOLD-MRI has shown that patients suffering from chronic kidney disease (CKD) or kidneys with severe renal artery stenosis have lower tissue oxygenation than controls. Additionally, CKD patients with the lowest cortical oxygenation have the worst renal outcome. Finally, BOLD-MRI has been used to assess the influence of drugs on renal tissue oxygenation, and may offer the possibility to identify drugs with nephroprotective or nephrotoxic effects at an early stage. Unfortunately, different methods are used to prepare patients, acquire MRI data and analyse the BOLD images. International efforts such as the European Cooperation in Science and Technology (COST) action 'Magnetic Resonance Imaging Biomarkers for Chronic Kidney Disease' (PARENCHIMA) are aiming to harmonize this process, to facilitate the introduction of this technique in clinical practice in the near future. This article represents an extensive overview of the studies performed in this field, summarizes the strengths and weaknesses of the technique, provides recommendations about patient preparation, image acquisition and analysis, and suggests clinical applications and future developments.


Asunto(s)
Biomarcadores/sangre , Riñón/fisiología , Oxígeno/metabolismo , Guías de Práctica Clínica como Asunto/normas , Insuficiencia Renal Crónica/fisiopatología , Humanos , Hipoxia , Riñón/irrigación sanguínea , Imagen por Resonancia Magnética/métodos , Consumo de Oxígeno
20.
Nephrol Dial Transplant ; 33(suppl_2): ii41-ii50, 2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-30137583

RESUMEN

This systematic review, initiated by the European Cooperation in Science and Technology Action Magnetic Resonance Imaging Biomarkers for Chronic Kidney Disease (PARENCHIMA), focuses on potential clinical applications of magnetic resonance imaging in renal non-tumour disease using magnetic resonance relaxometry (MRR), specifically, the measurement of the independent quantitative magnetic resonance relaxation times T1 and T2 at 1.5 and 3Tesla (T), respectively. Healthy subjects show a distinguishable cortico-medullary differentiation (CMD) in T1 and a slight CMD in T2. Increased cortical T1 values, that is, reduced T1 CMD, were reported in acute allograft rejection (AAR) and diminished T1 CMD in chronic allograft rejection. However, ambiguous findings were reported and AAR could not be sufficiently differentiated from acute tubular necrosis and cyclosporine nephrotoxicity. Despite this, one recent quantitative study showed in renal transplants a direct correlation between fibrosis and T1 CMD. Additionally, various renal diseases, including renal transplants, showed a moderate to strong correlation between T1 CMD and renal function. Recent T2 studies observed increased values in renal transplants compared with healthy subjects and in early-stage autosomal dominant polycystic kidney disease (ADPKD), which could improve diagnosis and progression assessment compared with total kidney volume alone in early-stage ADPKD. Renal MRR is suggested to be sensitive to renal perfusion, ischaemia/oxygenation, oedema, fibrosis, hydration and comorbidities, which reduce specificity. Due to the lack of standardization in patient preparation, acquisition protocols and adequate patient selection, no widely accepted reference values are currently available. Therefore this review encourages efforts to optimize and standardize (multi-parametric) protocols to increase specificity and to tap the full potential of renal MRR in future research.


Asunto(s)
Biomarcadores/análisis , Enfermedades Renales/patología , Riñón/fisiopatología , Imagen por Resonancia Magnética/métodos , Guías de Práctica Clínica como Asunto/normas , Progresión de la Enfermedad , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA