RESUMEN
BACKGROUND: Early detection can prevent the initial stages of fibrosis from progressing to cirrhosis. PURPOSE: To evaluate an algorithm combining three echographic indicators and elastographic measurements to screen for hepatic fibrosis in an unselected population. MATERIAL AND METHODS: From May 2017 to June 2018, all patients with no history and no known chronic liver disease who were referred for an ultrasound (US) were prospectively included in eight hospitals. The indicators being sought were liver surface irregularity, demodulation of hepatic veins, and spleen length >110 mm. Patients presenting at least one of these underwent elastography measurements with virtual touch quantification (VTQ) or supersonic shear imaging (SSI). If elastography was positive, patients were referred to hepatologist for fibrosis evaluation. Reference standard was obtained by FibroMeterVCTE or biopsy. A FibroMeterVCTE result >0.384 indicated a "necessary referral" to a hepatologist. RESULTS: Of the 1501 patients included, 504 (33.6%) were positive for at least one US indicator. All of them underwent US elastography, with 85 being positive. Of the patients, 58 (3.6%) had a consultation with a liver specialist: 21 had positive FibroMeterVCTE and nine had an indication of biopsy for suspicion of fibrosis. This screening algorithm made it possible to diagnose 1.6% of patients in our population with unknown fibrosis. Of the patients, 50% referred to the liver specialist were "necessary referrals." CONCLUSION: Our study suggests that three simple US indicators with no systematic elastographic measurement could be applied in day-to-day practice to look for hepatic fibrosis in an unsuspected population allowing relevant referrals to a hepatologist.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/patología , Hígado/diagnóstico por imagen , Hígado/patología , Fibrosis , Algoritmos , Ultrasonografía DopplerRESUMEN
BACKGROUND & AIMS: Virtual Touch Quantification (VTQ) evaluates liver fibrosis in patients with chronic liver diseases by measuring shear wave speed in the liver. We aimed to determine the reliability criteria of VTQ examination. METHODS: We performed a prospective study of 1094 patients with chronic liver disease from November 2009 through October 2016 at Angers University Hospital, and between April 2010 and May 2015 at Bordeaux University Hospital, in France. All patients underwent liver biopsy analysis (reference standard), and VTQ examination was made by experienced operators on the same day, or no more than 3 months before or afterward. Advanced liver fibrosis was defined as fibrosis stage F ≥ 3 according to the scoring system of the Nonalcoholic Steatohepatitis Clinical Research Network, or fibrosis stage F ≥ 2 according to the Metavir scoring system. The diagnostic accuracy of VTQ in detection of advanced fibrosis or cirrhosis was assessed using the area under the receiver operating characteristic (AUROC) and the rate of correctly classiï¬ed patients. Reliability criteria were defined from the intrinsic characteristics of VTQ examination, which were shown to influence the diagnostic accuracy. RESULTS: VTQ identified patients with advanced fibrosis with an AUROC of 0.773 ± 0.014 and correctly classified 72.0% of patients using a diagnostic cut-off value of 1.37 m/s. VTQ identified patients with cirrhosis with an AUROC value of 0.839 ± 0.014 and correctly classified 78.4% of patients using a cut-off value of 1.87 m/s. The reliability of VTQ decreased with an increasing ratio of interquartile range/median (IQR/M) in patients with intermediate-high VTQ results. We defined 3 reliability categories for VTQ: unreliable (IQR/M ≥0.35 with VTQ result ≥1.37 m/s), reliable (IQR/M ≥0.35 with VTQ result <1.37 m/s or IQR/M 0.15-0.34), and very reliable (IQR/M <0.15). For advanced fibrosis, VTQ correctly classified 57.8% of patients in the unreliable group, 73.7% of patients in the reliable group, and 80.9% of patients in the very reliable group (P < .001); for cirrhosis, these values were 50.0%, 83.4%, and 92.6%, respectively (P < .001). Of the VTQ examinations made, 21.4% were unreliable, 55.0% were reliable, and 23.6% were very reliable. The skin-liver capsule distance was independently associated with an unreliable VTQ examination, which occurred in 52.7% of patients with a distance of 30 mm or more. CONCLUSIONS: In a study to determine the reliability of VTQ findings, compared with results from biopsy analysis, we assigned VTQ examinations to 3 categories (unreliable, reliable, and very reliable). VTQ examinations with IQR/M ≥0.35 and ≥1.37 m/s had very low diagnostic accuracy. Our reliability criteria for liver fibrosis assessment with VTQ will help physicians to accurately evaluate the severity of chronic liver diseases and monitor their progression.
Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROCRESUMEN
BACKGROUND & AIMS: The primary aim of this study was to compare the rate of global radiofrequency ablation (RFA) failure between monopolar RFA (MonoRFA) vs. no-touch multi-bipolar RFA (NTmbpRFA) for small hepatocellular carcinoma (HCC) ⩽5cm in cirrhotic patients. METHODS: A total of 362 cirrhotic patients were included retrospectively across four French centres (181 per treatment group). Global RFA failure (primary RFA failure or local tumour progression) was analysed using the Kaplan-Meier method after coarsened exact matching. Cox regression models were used to identify factors associated with global RFA failure and overall survival (OS). RESULTS: Patients were well matched according to tumour size (⩽30/>30mm); tumour number (one/several); tumour location (subcapsular and near large vessel); serum AFP (<10; 10-100; >100ng/ml); Child-Pugh score (A/B) and platelet count (⩾100G/L), p=1 for all. One case of perioperative mortality was observed in the NTmbpRFA group and the rate of major complications was 7.2% in both groups (p=1). The cumulative rates of global RFA failure at 1, 3 and 5years were respectively 13.3%, 31% and 36.7% for MonoRFA vs. 0.02%, 7.9% and 9.2% for NTmbpRFA, p<0.001. Monopolar RFA, tumour size >30mm and HCC near large vessel were independent factors associated with global RFA failure. Five-year OS was 37.2% following MonoRFA vs. 46.4% following NTmbpRFA p=0.378. CONCLUSIONS: This large multicentre case-matched study showed that NTmbpRFA provided better primary RFA success and sustained local tumour response without increasing severe complications rates, for HCC ⩽5cm. LAY SUMMARY: Using no-touch multi-bipolar radiofrequency ablation for hepatocellular carcinoma ⩽5cm provide a better sustained local tumour control compared to monopolar radiofrequency ablation.
Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Hepáticas , Adulto , Anciano , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Estudios de Casos y Controles , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Francia , Humanos , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Recurrencia Local de Neoplasia , Estadificación de Neoplasias , Evaluación de Resultado en la Atención de Salud , Carga TumoralRESUMEN
UNLABELLED: Nonalcoholic fatty liver disease (NAFLD) has become a major public health issue. The goal of this study was to assess the clinical use of liver stiffness measurement (LSM) evaluated by supersonic shear imaging (SSI), FibroScan, and acoustic radiation force impulse (ARFI) in a cohort of NAFLD patients who underwent liver biopsy. A total of 291 NAFLD patients were prospectively enrolled from November 2011 to February 2015 at 2 French university hospitals. LSM was assessed by SSI, FibroScan (M probe), and ARFI within two weeks prior to liver biopsy. Calculations of the area under the receiver operating curve (AUROC) were performed and compared for the staging of liver fibrosis. AUROC for SSI, FibroScan, and ARFI were 0.86, 0.82, and 0.77 for diagnoses of ≥F2; 0.89, 0.86, and 0.84 for ≥F3; and 0.88, 0.87, and 0.84 for F4, respectively. SSI had a higher accuracy than ARFI for diagnoses of significant fibrosis (≥F2) (P = 0.004). Clinical factors related to obesity such as body mass index ≥ 30 kg/m(2) , waist circumference ≥102 cm or increased parietal wall thickness were associated with LSM failures when using SSI or FibroScan and with unreliable results when using ARFI. In univariate analysis, FibroScan values were slightly correlated with NAFLD activity score and steatosis (R = 0.28 and 0.22, respectively), whereas SSI and ARFI were not; however, these components of NAFLD did not affect LSM results in multivariate analysis. The cutoff values for SSI and FibroScan for staging fibrosis with a sensitivity ≥90% were very close: 6.3/6.2 kPa for ≥F2, 8.3/8.2 kPa for ≥F3, and 10.5/9.5 kPa for F4. CONCLUSION: Although obesity is associated with an increase in LSM failure, the studied techniques and especially SSI provide high value for the diagnosis of liver fibrosis in NAFLD patients. (Hepatology 2016;63:1817-1827).
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/etiología , Cirrosis Hepática/patología , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Enfermedad del Hígado Graso no Alcohólico/patología , Estudios Prospectivos , Adulto JovenRESUMEN
BACKGROUND AND AIMS: Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. METHODS: A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). RESULTS: Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P < 0.001) and tumor size (P = 0.023) were independent predictors of radiofrequency failure. Failure rate was lower with the multipolar technique for tumors < 25 mm (P = 0.023) and for tumors between 25 and 45 mm (P = 0.082). There was no difference for tumors ≥ 45 mm (P = 0.552). CONCLUSIONS: Compared to monopolar radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence.
Asunto(s)
Carcinoma Hepatocelular/cirugía , Ablación por Catéter/métodos , Neoplasias Hepáticas/cirugía , Anciano , Carcinoma Hepatocelular/patología , Electrodos , Femenino , Estudios de Seguimiento , Predicción , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Análisis Multivariante , Recurrencia Local de Neoplasia/epidemiología , Recurrencia Local de Neoplasia/prevención & control , Insuficiencia del TratamientoRESUMEN
BACKGROUND: Liver resection is the curative treatment for patients with colorectal liver metastases (CRLMs), with five-year survival rates of 30-50%. Radiofrequency ablation (RFA) is a local and useful alternative for patients with non-resectable CRLMs to obtain complete tumor clearance. The aim of this study was to analyze survival rates with this local treatment. MATERIALS AND METHODS: All patients who underwent RFA and resection or RFA alone for unresectable CRLMs between 2001 and 2012 were included in a retrospective study. Descriptive and survival statistics were calculated. Morbidity, mortality, and recurrence were also analyzed. RESULTS: The study involved 72 patients and 179 lesions. RFA was performed in 109 procedures. Mortality was 2.7% and morbidity was 25.7%. Local recurrence concerned 25.7% of lesions. Independent risk factors for recurrence were more than one CRLM (p= 0.0427) and size of largest CRLM greater than 3 cm (p= 0.0139). The five-year overall survival rate was 45.5% and the five-year disease-free survival (DFS) was 9.9%. CONCLUSION: This study shows RFA has good oncological outcomes. The combination of RFA and resection is considered as a curative treatment for patients with unresectable CRLMs.
Asunto(s)
Ablación por Catéter , Neoplasias Colorrectales/patología , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/terapia , Hepatectomía , Humanos , Recurrencia Local de Neoplasia , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
OBJECTIVES: Advanced chronic liver disease is frequent yet largely underdiagnosed. Doppler-US is a common examination and we recently identified three simple Doppler-US signs associated with severe liver fibrosis. Recent Doppler-US devices include elastography modules, allowing for liver stiffness measurement (LSM). Our aim was to assess whether the use of elastography following positive simple Doppler-US signs improves the detection of severe liver fibrosis in a single Doppler-US examination. METHODS: 514 patients with chronic liver disease who consecutively underwent percutaneous liver biopsy were included in the study. All patients had a Doppler-US examination and LSM with Virtual Touch Quantification (VTQ) on the same day as a liver biopsy. A subset of 326 patients also had LSM with 2D shear wave elastography (SSI). Severe fibrosis was defined as Metavir F ≥ 3 on liver biopsy. RESULTS: Multivariate analysis confirmed our three simple Doppler-US signs (liver surface irregularity, splenomegaly ≥110 mm, and demodulation of hepatic veins) as independently associated with severe fibrosis. The presence of at least one of these three signs showed 85.6% sensitivity and 36.1% specificity for the diagnosis of severe liver fibrosis. Using VTQ (≥1.59 m/s) where there was a positive Doppler-US sign increased the specificity to 80.8%, at the cost of a decrease in sensitivity (73.7%). Similar results were obtained with SSI (≥9.5 kPa), with 73.3% specificity and 81.5% sensitivity. CONCLUSION: Elastography improves the accuracy of Doppler-US in the detection of severe fibrosis. This two-step procedure will help radiologists to accurately identify patients who need to be referred to specialist hepatologists during routine Doppler-US examinations.