Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Dermatol Ther ; 33(6): e14193, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32790189

RESUMEN

Bone is the fourth most common site of melanoma metastasis after lung, liver, and brain. Melanoma bone metastases typically occur in patients who already have widespread metastases in other organs. Current available approaches for bone metastases from melanoma include chemotherapy, radiotherapy, biological therapy, combination therapy, and surgery. In this narrative review, we describe the management of patients affected by melanoma bone metastases, discussing the diagnostic and treatment approaches as well as their impact on survival and quality of life. Despite the fact that clinical and surgical trials will be required to determine the most appropriate treatment, we do expect a newer and more important role of multidisciplinary approach in the management of melanoma patients with bone metastases in the next future.


Asunto(s)
Neoplasias Encefálicas , Melanoma , Terapia Combinada , Humanos , Melanoma/terapia , Calidad de Vida
2.
Acta Biomed ; 93(S1): e2022206, 2022 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-36129744

RESUMEN

Intraprosthetic dislocation (IPD) is a specific implant-related complication of dual mobility (DM) implants, which is defined as a dissociation of polyethylene (PE) liner from the femoral head. We report a unique case of  late IPD of a monoblock DM cup cemented into a well-fixed cementless acetabular shell for recurrent dislocation of total hip arthroplasty (THA). A 77-year-old woman was admitted to our department for acute right hip pain, functional impairment and inability to bear weight without any trauma. Three years earlier, she underwent revision THA for recurrent dislocation with a monoblock DM cup cemented into a well-fixed cementless acetabular shell according to the "double-socket" technique. Three months after that revision the patient experienced an anterior THA dislocation, which was managed by closed reduction under sedation in the emergency room. No additional episodes of prosthesis instability occurred. Upon admission, radiographic evaluation showed  right THA dislocation. X-rays performed  after closed reduction revealed eccentric positioning of the head inside the cup, and a direct contact between the metal head and the cup was revealed by subsequent CT scan, confirming the suspicion of IPD. The patient underwent revision surgery, during which the PE liner was found lodged within the cup in a subluxated position, disassembled from the inner head. Both the acetabular cup and modular femoral stem proved well-fixed and impossible to remove, therefore they were retained. The explanted DM components were replaced with new ones of the same size and, thanks to the femoral neck's modular nature, it was substituted with a longer one, which resulted in improved stability against intraoperative stress maneuvers. The postoperative course was uncomplicated. At 1-year follow-up, the patient had a good functional recovery.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Acetábulo/cirugía , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Estudios de Seguimiento , Humanos , Luxaciones Articulares/cirugía , Polietileno , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA