Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Nutr Metab Cardiovasc Dis ; 34(3): 799-806, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38218711

RESUMEN

BACKGROUND AND AIMS: Body fat distribution, i.e., visceral (VAT), subcutaneous adipose tissue (SAT) and intramuscular fat, is important for disease prevention, but sex and ethnic differences are not well understood. Our aim was to identify anthropometric, demographic, and lifestyle predictors for these outcomes. METHODS AND RESULTS: The cross-sectional ShapeUp!Kids study was conducted among five ethnic groups aged 5-18 years. All participants completed questionnaires, anthropometric measurements, and abdominal MRI scans. VAT and SAT areas at four lumbar levels and muscle density were assessed manually. General linear models were applied to estimate coefficients of determination (R2) and to compare the fit of VAT and SAT prediction models. After exclusions, the study population had 133 male and 170 female participants. Girls had higher BMI-z scores, waist circumference (WC), and SAT than boys but lower VAT/SAT and muscle density. SAT, VAT, and VAT/SAT but not muscle density differed significantly by ethnicity. R2 values were higher for SAT than VAT across groups and improved slightly after adding WC. For SAT, R2 increased from 0.85 to 0.88 (girls) and 0.62 to 0.71 (boys) when WC was added while VAT models improved from 0.62 to 0.65 (girls) and 0.57 to 0.62 (boys). VAT values were significantly lower among Blacks than Whites with little difference for the other groups. CONCLUSION: This analysis in a multiethnic population identified BMI-z scores and WC as the major predictors of MRI-derived SAT and VAT and highlights the important ethnic differences that need to be considered in diverse populations.


Asunto(s)
Músculos , Grasa Subcutánea , Humanos , Masculino , Femenino , Estudios Transversales , Grasa Subcutánea/diagnóstico por imagen , Antropometría/métodos , Circunferencia de la Cintura
2.
J Nutr ; 152(9): 2048-2059, 2022 09 06.
Artículo en Inglés | MEDLINE | ID: mdl-35665820

RESUMEN

BACKGROUND: Deuterium oxide (D2O) dilution is the criterion method for total body water (TBW) measurement, but results may vary depending on the specimen type, analysis method, and analyzing laboratory. Bioelectrical impedance (BIA) estimates TBW, but results may vary by device make and model. OBJECTIVES: We investigated the accuracy and precision of TBW estimates and how measurement conditions affected the accuracy of body composition using multicompartment body composition models. METHODS: Eighty collegiate athletes received duplicate TBW measures acquired from 3 BIA devices (S10, SFB7, and SOZO) and from unique D2O combinations of specimen type (saliva, urine), analysis methodology [Fourier transform infrared spectrophotometry (FTIR), isotope-ratio mass spectrometry (IRMS)], and 3 different laboratories. TBW measures were substituted into 2-compartment (2C) and 5-compartment (5C) body composition models. Criterion measures were compared using Lin's concordance correlation coefficient cutoff of poor (<0.90), moderate (0.90-0.95), substantial (0.95-0.99), and almost perfect (>0.99). RESULTS: Fifty-one participants (26 female) completed the protocol. Using IRMS saliva as the criterion TBW, all other measures produced a substantial or almost perfect agreement, except for SFB7 (poor) and SOZO (moderate). The 2C body composition measures using D2O and BIA produced poor agreement except for moderate agreement for lab 3 FTIR saliva. The 5C body composition measures using D2O produced a substantial agreement, whereas the BIA device S10 and SOZO had a moderate agreement, while the SFB7 had a poor agreement to the criterion. Test-retest precision varied between techniques from 0.3% to 1.2% for TBW. CONCLUSIONS: Small differences in TBW measurement led to significant differences in 2C models. The 5C models partially mitigate differences seen in 2C models when different TBW measures are used. Interchanging TBW measures in multicompartment models can be problematic and should be performed with these considerations.


Asunto(s)
Composición Corporal , Agua Corporal , Atletas , Deuterio , Óxido de Deuterio , Impedancia Eléctrica , Femenino , Humanos , Técnicas de Dilución del Indicador
3.
Clin Nutr ; 43(2): 346-356, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38142479

RESUMEN

BACKGROUND & AIMS: The multicompartment approach to body composition modeling provides a more precise quantification of body compartments in healthy and clinical populations. We sought to develop and validate a simplified and accessible multicompartment body composition model using 3-dimensional optical (3DO) imaging and bioelectrical impedance analysis (BIA). METHODS: Samples of adults and collegiate-aged student-athletes were recruited for model calibration. For the criterion multicompartment model (Wang-5C), participants received measures of scale weight, body volume (BV) via air displacement, total body water (TBW) via deuterium dilution, and bone mineral content (BMC) via dual energy x-ray absorptiometry. The candidate model (3DO-5C) used stepwise linear regression to derive surrogate measures of BV using 3DO, TBW using BIA, and BMC using demographics. Test-retest precision of the candidate model was assessed via root mean square error (RMSE). The 3DO-5C model was compared to criterion via mean difference, concordance correlation coefficient (CCC), and Bland-Altman analysis. This model was then validated using a separate dataset of 20 adults. RESULTS: 67 (31 female) participants were used to build the 3DO-5C model. Fat-free mass (FFM) estimates from Wang-5C (60.1 ± 13.4 kg) and 3DO-5C (60.3 ± 13.4 kg) showed no significant mean difference (-0.2 ± 2.0 kg; 95 % limits of agreement [LOA] -4.3 to +3.8) and the CCC was 0.99 with a similar effect in fat mass that reflected the difference in FFM measures. In the validation dataset, the 3DO-5C model showed no significant mean difference (0.0 ± 2.5 kg; 95 % LOA -3.6 to +3.7) for FFM with almost perfect equivalence (CCC = 0.99) compared to the criterion Wang-5C. Test-retest precision (RMSE = 0.73 kg FFM) supports the use of this model for more frequent testing in order to monitor body composition change over time. CONCLUSIONS: Body composition estimates provided by the 3DO-5C model are precise and accurate to criterion methods when correcting for field calibrations. The 3DO-5C approach offers a rapid, cost-effective, and accessible method of body composition assessment that can be used broadly to guide nutrition and exercise recommendations in athletic settings and clinical practice.


Asunto(s)
Composición Corporal , Densidad Ósea , Adulto , Humanos , Femenino , Anciano , Impedancia Eléctrica , Absorciometría de Fotón/métodos , Imagen Óptica , Reproducibilidad de los Resultados
4.
Clin Nutr ; 43(1): 284-294, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38104490

RESUMEN

BACKGROUND: Athletes vary in hydration status due to ongoing training regimes, diet demands, and extreme exertion. With water being one of the largest body composition compartments, its variation can cause misinterpretation of body composition assessments meant to monitor strength and training progress. In this study, we asked what accessible body composition approach could best quantify body composition in athletes with a variety of hydration levels. METHODS: The Da Kine Study recruited collegiate and intramural athletes to undergo a variety of body composition assessments including air-displacement plethysmography (ADP), deuterium-oxide dilution (D2O), dual-energy X-ray absorptiometry (DXA), underwater-weighing (UWW), 3D-optical (3DO) imaging, and bioelectrical impedance (BIA). Each of these methods generated 2- or 3-compartment body composition estimates of fat mass (FM) and fat-free mass (FFM) and was compared to equivalent measures of the criterion 6-compartment model (6CM) that accounts for variance in hydration. Body composition by each method was used to predict abdominal and thigh strength, assessed by isokinetic/isometric dynamometry. RESULTS: In total, 70 (35 female) athletes with a mean age of 21.8 ± 4.2 years were recruited. Percent hydration (Body Water6CM/FFM6CM) had substantial variation in both males (63-73 %) and females (58-78 %). ADP and DXA FM and FF M had moderate to substantial agreement with the 6C model (Lin's Concordance Coefficient [CCC] = 0.90-0.95) whereas the other measures had lesser agreement (CCC <0.90) with one exception of 3DO FFM in females (CCC = 0.91). All measures of FFM produced excellent precision with %CV < 1.0 %. However, FM measures in general had worse precision (% CV < 2.0 %). Increasing quartiles (significant p < 0.001 trend) of 6CM FFM resulted in increasing strength measures in males and females. Moreover, the stronger the agreement between the alternative methods to the 6CM, the more robust their correlation with strength, irrespective of hydration status. CONCLUSION: The criterion 6CM showed the best association to strength regardless of the hydration status of the athletes for both males and females. Simpler methods showed high precision for both FM and FFM and those with the strongest agreement to the 6CM had the highest strength associations. SUMMARY BOX: This study compared various body composition analysis methods in 70 athletes with varying states of hydration to the criterion 6-compartment model and assessed their relationship to muscle strength. The results showed that accurate and precise estimates of body composition can be determined in athletes, and a more accurate body composition measurement produces better strength estimates. The best laboratory-based techniques were air displacement plethysmography and dual-energy x-ray absorptiometry, while the commercial methods had moderate-poor agreement. Prioritizing accurate body composition assessment ensures better strength estimates in athletes.


Asunto(s)
Composición Corporal , Agua Corporal , Masculino , Humanos , Femenino , Adolescente , Adulto Joven , Adulto , Composición Corporal/fisiología , Atletas , Absorciometría de Fotón/métodos , Impedancia Eléctrica , Fuerza Muscular , Reproducibilidad de los Resultados
5.
Commun Med (Lond) ; 4(1): 13, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38287144

RESUMEN

BACKGROUND: Body shape, an intuitive health indicator, is deterministically driven by body composition. We developed and validated a deep learning model that generates accurate dual-energy X-ray absorptiometry (DXA) scans from three-dimensional optical body scans (3DO), enabling compositional analysis of the whole body and specified subregions. Previous works on generative medical imaging models lack quantitative validation and only report quality metrics. METHODS: Our model was self-supervised pretrained on two large clinical DXA datasets and fine-tuned using the Shape Up! Adults study dataset. Model-predicted scans from a holdout test set were evaluated using clinical commercial DXA software for compositional accuracy. RESULTS: Predicted DXA scans achieve R2 of 0.73, 0.89, and 0.99 and RMSEs of 5.32, 6.56, and 4.15 kg for total fat mass (FM), fat-free mass (FFM), and total mass, respectively. Custom subregion analysis results in R2s of 0.70-0.89 for left and right thigh composition. We demonstrate the ability of models to produce quantitatively accurate visualizations of soft tissue and bone, confirming a strong relationship between body shape and composition. CONCLUSIONS: This work highlights the potential of generative models in medical imaging and reinforces the importance of quantitative validation for assessing their clinical utility.


Body composition, measured quantities of muscle, fat, and bone, is typically assessed through dual energy X-ray absorptiometry (DXA) scans, which requires specialized equipment, trained technicians and involves exposure to radiation. Exterior body shape is dependent on body composition and recent technological advances have made three-dimensional (3D) scanning for body shape accessible and virtually ubiquitous. We developed a model which uses 3D body surface scan inputs to generate DXA scans. When analyzed with commercial software that is used clinically, our model generated images yielded accurate quantities of fat, lean, and bone. Our work highlights the strong relationship between exterior body shape and interior composition. Moreover, it suggests that with enhanced accuracy, such medical imaging models could be more widely adopted in clinical care, making the analysis of body composition more accessible and easier to obtain.

6.
J Cachexia Sarcopenia Muscle ; 13(6): 2595-2607, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36059250

RESUMEN

The French chemist Michel Eugène Chevreul discovered creatine in meat two centuries ago. Extensive biochemical and physiological studies of this organic molecule followed with confirmation that creatine is found within the cytoplasm and mitochondria of human skeletal muscles. Two groups of investigators exploited these relationships five decades ago by first estimating the creatine pool size in vivo with 14 C and 15 N labelled isotopes. Skeletal muscle mass (kg) was then calculated by dividing the creatine pool size (g) by muscle creatine concentration (g/kg) measured on a single muscle biopsy or estimated from the literature. This approach for quantifying skeletal muscle mass is generating renewed interest with the recent introduction of a practical stable isotope (creatine-(methyl-d3 )) dilution method for estimating the creatine pool size across the full human lifespan. The need for a muscle biopsy has been eliminated by assuming a constant value for whole-body skeletal muscle creatine concentration of 4.3 g/kg wet weight. The current single compartment model of estimating creatine pool size and skeletal muscle mass rests on four main assumptions: tracer absorption is complete; tracer is all retained; tracer is distributed solely in skeletal muscle; and skeletal muscle creatine concentration is known and constant. Three of these assumptions are false to varying degrees. Not all tracer is retained with urinary isotope losses ranging from 0% to 9%; an empirical equation requiring further validation is used to correct for spillage. Not all tracer is distributed in skeletal muscle with non-muscle creatine sources ranging from 2% to 10% with a definitive value lacking. Lastly, skeletal muscle creatine concentration is not constant and varies between muscles (e.g. 3.89-4.62 g/kg), with diets (e.g. vegetarian and omnivore), across age groups (e.g. middle-age, ~4.5 g/kg; old-age, 4.0 g/kg), activity levels (e.g. athletes, ~5 g/kg) and in disease states (e.g. muscular dystrophies, <3 g/kg). Some of the variability in skeletal muscle creatine concentrations can be attributed to heterogeneity in the proportions of wet skeletal muscle as myofibres, connective tissues, and fat. These observations raise serious concerns regarding the accuracy of the deuterated-creatine dilution method for estimating total body skeletal muscle mass as now defined by cadaver analyses of whole wet tissues and in vivo approaches such as magnetic resonance imaging. A new framework is needed in thinking about how this potentially valuable method for measuring the creatine pool size in vivo can be used in the future to study skeletal muscle biology in health and disease.


Asunto(s)
Creatina , Músculo Esquelético , Persona de Mediana Edad , Humanos , Preescolar , Técnicas de Dilución del Indicador , Músculo Esquelético/patología , Atletas , Imagen por Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA