1.
Curr Cardiol Rep ; 26(3): 97-112, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38324216

RESUMEN

PURPOSE OF REVIEW: Coronavirus disease-2019 (COVID-19) vaccines have been related to rare cases of acute myocarditis, occurring between 1 in 10,000 and 1 in 100,000 individuals, approximately. Incidence of COVID-19 vaccine-associated myocarditis varies with age, sex, and type of vaccine. Although most patients with acute myocarditis temporally associated with COVID-19 vaccines have an uneventful course, a small subpopulation presents with cardiogenic shock (termed fulminant myocarditis [FM]). This review explored the prevalence, clinical presentation, management, and prognosis of COVID-19 vaccine-associated acute myocarditis, specifically focusing on FM and comparing patients with fulminant versus non-fulminant myocarditis. RECENT FINDINGS: Cases of FM represent about 2-4% (0 to 7.5%) of COVID-19 vaccine-associated acute myocarditis cases, and mortality is around 1%, ranging between 0 and 4.4%. First, we identified 40 cases of FM up to February 2023 with sufficient granular data from case reports and case series of COVID-19 vaccine-associated acute myocarditis that occurred within 30 days from the last vaccine injection. This population was compared with 294 cases of non-fulminant acute myocarditis identified in the literature during a similar time. Patients with FM were older (48 vs. 27 years), had a larger proportion of women (58% vs. 9%), and mainly occurred after the first shot compared with non-fulminant cases (58% vs. 16%). The reported mortality was 27% (11 out of 40), in line with non-vaccine-associated fulminant myocarditis. These data were in agreement with 36 cases of FM from a large Korean registry. Herein, we reviewed the clinical features, imaging results, and histological findings of COVID-19 vaccine-associated fulminant myocarditis. In conclusion, COVID-19 vaccine-associated FM differs from non-fulminant forms, suggesting potential specific mechanisms in these rare and severe forms. Mortality in vaccine-associated FM remains high, in line with other forms of FM.


Asunto(s)
COVID-19 , Miocarditis , Femenino , Humanos , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Miocarditis/inducido químicamente , Sistema de Registros , Vacunación/efectos adversos , Masculino , Adulto , Persona de Mediana Edad
2.
Eur Radiol ; 33(11): 7756-7768, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37166497

RESUMEN

OBJECTIVE: To assess the value of opportunistic biomarkers derived from chest CT performed at hospital admission of COVID-19 patients for the phenotypization of high-risk patients. METHODS: In this multicentre retrospective study, 1845 consecutive COVID-19 patients with chest CT performed within 72 h from hospital admission were analysed. Clinical and outcome data were collected by each center 30 and 80 days after hospital admission. Patients with unknown outcomes were excluded. Chest CT was analysed in a single core lab and behind pneumonia CT scores were extracted opportunistic data about atherosclerotic profile (calcium score according to Agatston method), liver steatosis (≤ 40 HU), myosteatosis (paraspinal muscle F < 31.3 HU, M < 37.5 HU), and osteoporosis (D12 bone attenuation < 134 HU). Differences according to treatment and outcome were assessed with ANOVA. Prediction models were obtained using multivariate binary logistic regression and their AUCs were compared with the DeLong test. RESULTS: The final cohort included 1669 patients (age 67.5 [58.5-77.4] yo) mainly men 1105/1669, 66.2%) and with reduced oxygen saturation (92% [88-95%]). Pneumonia severity, high Agatston score, myosteatosis, liver steatosis, and osteoporosis derived from CT were more prevalent in patients with more aggressive treatment, access to ICU, and in-hospital death (always p < 0.05). A multivariable model including clinical and CT variables improved the capability to predict non-critical pneumonia compared to a model including only clinical variables (AUC 0.801 vs 0.789; p = 0.0198) to predict patient death (AUC 0.815 vs 0.800; p = 0.001). CONCLUSION: Opportunistic biomarkers derived from chest CT can improve the characterization of COVID-19 high-risk patients. CLINICAL RELEVANCE STATEMENT: In COVID-19 patients, opportunistic biomarkers of cardiometabolic risk extracted from chest CT improve patient risk stratification. KEY POINTS: • In COVID-19 patients, several information about patient comorbidities can be quantitatively extracted from chest CT, resulting associated with the severity of oxygen treatment, access to ICU, and death. • A prediction model based on multiparametric opportunistic biomarkers derived from chest CT resulted superior to a model including only clinical variables in a large cohort of 1669 patients suffering from SARS- CoV2 infection. • Opportunistic biomarkers of cardiometabolic comorbidities derived from chest CT may improve COVID-19 patients' risk stratification also in absence of detailed clinical data and laboratory tests identifying subclinical and previously unknown conditions.


Asunto(s)
COVID-19 , Enfermedades Cardiovasculares , Hígado Graso , Osteoporosis , Masculino , Humanos , Anciano , Femenino , Estudios Retrospectivos , SARS-CoV-2 , Mortalidad Hospitalaria , Tomografía Computarizada por Rayos X/métodos , Biomarcadores
3.
Catheter Cardiovasc Interv ; 100 Suppl 1: S25-S35, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36661369

RESUMEN

BACKGROUND: Uncovered struts are a determinant of stent failure. The impact of plaque composition and procedural factors on the occurrence, evolution, and outcomes of uncovered struts in a high-risk setting has not been investigated. OBJECTIVE: To investigate the determinants and long-term clinical impact of largely uncovered struts (LUS) in thin-struts drug-eluting stents (DES) implanted in complex lesions by intracoronary optical coherence tomography (OCT). METHODS: Ninety patients with multivessel disease undergoing staged complete revascularization were randomly assigned to bioabsorbable or durable polymer DES. OCT were serially performed during the index procedure, at 3- and 18-month follow-up, and analyzed by an independent core lab. Struts were defined uncovered by OCT if no tissue was visible above the struts. LUS were defined as ≥30% of uncovered struts at 3-month follow-up. Clinical outcomes were the occurrence of target vessel failure (TVF) and major adverse cardiac and cerebrovascular events (MACCE) at 5-year follow-up. RESULTS: LUS occurred in 31 patients (34.4%) regardless of stent platform. At 5 years, no differences were observed in the rate of TVF (12.7% vs. 13.4%; p = 0.91) and MACCE (23.9% vs. 24.9%; p = 0.88) between the two groups. At multivariate logistic regression, plaque rupture, mean lumen diameter, proximal reference vessel area, and maximum stent deployment pressure were independent predictors of LUS. CONCLUSIONS: LUS are a frequent finding in complex coronary lesions treated with thin-struts DES, especially in the presence of plaque rupture. However, in this study, no significant safety signal related to LUS emerged in long-term follow-up.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Placa Aterosclerótica , Humanos , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento , Diseño de Prótesis , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos
4.
Clin Med Res ; 20(4): 219-230, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36581397

RESUMEN

Objective: To assess the effectiveness of multidisciplinary integrated care in the clinical outcomes of atrial fibrillation patients.Methods: Medline, EMBASE, and the CENTRAL trials registry of the Cochrane Collaboration were searched for articles on multidisciplinary integrated care in atrial fibrillation patients. The systematic review and meta-analysis included six and five articles, respectively, that compared the outcomes between the integrated care group and control group.Results: Multidisciplinary integrated care was concomitant with a decrease in all-cause mortality (OR 0.52, 95%CI 0.36-0.74, P=0.0003) and cardiovascular hospitalization (OR 0.66, 95%CI 0.49-0.89, P=0.007). Multidisciplinary integrated care had no significant impact on major adverse cardiovascular event (MACE) (OR 0.76, 95%CI 0.37-1.53, P=0.44), cardiovascular deaths (OR 0.49, 95% CI 0.21-1.17, P=0.11), atrial fibrillation (AF)-related hospitalization (OR 0.76, 95%CI 0.53-1.09, P=0.14), major bleeding (OR 1.02, 95%CI 0.59-1.75, P=0.94), minor bleeding (OR 1.12, 95%CI 0.55-2.26, P=0.76), and cerebrovascular events (OR 0.72, 95%CI 0.45-1.18, P=0.19).Conclusion: In comparison to usual care, a multidisciplinary integrated care approach (i.e., nurse-led care along with usual specialist care) in AF patients is associated with reduced all-cause mortality and cardiovascular hospitalization.


Asunto(s)
Fibrilación Atrial , Prestación Integrada de Atención de Salud , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Hemorragia/complicaciones , Corazón
5.
Radiol Med ; 127(9): 960-972, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36038790

RESUMEN

PURPOSE: To develop and validate an effective and user-friendly AI platform based on a few unbiased clinical variables integrated with advanced CT automatic analysis for COVID-19 patients' risk stratification. MATERIAL AND METHODS: In total, 1575 consecutive COVID-19 adults admitted to 16 hospitals during wave 1 (February 16-April 29, 2020), submitted to chest CT within 72 h from admission, were retrospectively enrolled. In total, 107 variables were initially collected; 64 extracted from CT. The outcome was survival. A rigorous AI model selection framework was adopted for models selection and automatic CT data extraction. Model performances were compared in terms of AUC. A web-mobile interface was developed using Microsoft PowerApps environment. The platform was externally validated on 213 COVID-19 adults prospectively enrolled during wave 2 (October 14-December 31, 2020). RESULTS: The final cohort included 1125 patients (292 non-survivors, 26%) and 24 variables. Logistic showed the best performance on the complete set of variables (AUC = 0.839 ± 0.009) as in models including a limited set of 13 and 5 variables (AUC = 0.840 ± 0.0093 and AUC = 0.834 ± 0.007). For non-inferior performance, the 5 variables model (age, sex, saturation, well-aerated lung parenchyma and cardiothoracic vascular calcium) was selected as the final model and the extraction of CT-derived parameters was fully automatized. The fully automatic model showed AUC = 0.842 (95% CI: 0.816-0.867) on wave 1 and was used to build a 0-100 scale risk score (AI-SCoRE). The predictive performance was confirmed on wave 2 (AUC 0.808; 95% CI: 0.7402-0.8766). CONCLUSIONS: AI-SCoRE is an effective and reliable platform for automatic risk stratification of COVID-19 patients based on a few unbiased clinical data and CT automatic analysis.


Asunto(s)
COVID-19 , Adulto , Inteligencia Artificial , Calcio , Humanos , Estudios Retrospectivos , SARS-CoV-2
6.
Catheter Cardiovasc Interv ; 97(7): E900-E910, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33201611

RESUMEN

OBJECTIVES AND BACKGROUND: Iatrogenic aorto-coronary dissection (ICD) is one of the most feared complications of interventional cardiology. Although rare, it is characterized by anterograde coronary ischemia and a concomitant aortic dissection, with potentially fatal consequences. METHODS: We present an example case of IACD and an accurate case-series review of the literature including 125 published cases. RESULTS: There were no significant predisposing factors and the IACD occurred equally in elective and urgent procedures. A significant number of IACDs were associated with CTO procedures. The factors associated with a worse outcome were hemodynamic instability, the presence of anterograde ischemia, and the extent of dissection according to the Dunning classification. Bail-out stenting was the most used strategy and its failure was associated with mortality. CONCLUSION: The main features of IACD are anterograde ischemia, retrograde dissection, and hemodynamic instability, each of them should be addressed with no time delay, possibly with bailout stenting, the most employed exit-strategy. According to our proposed algorithm, a shock team approach is required to coordinate the interdisciplinary skills and enabled patients to receive the best treatment.


Asunto(s)
Disección Aórtica , Vasos Coronarios , Humanos , Aorta , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Disección Aórtica/cirugía , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Disección , Enfermedad Iatrogénica , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 98(3): 595-604, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33586278

RESUMEN

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is an emerging alternative to re-do surgery. However, the challenge of coronary access (CA) following ViV-TAVR is a potential limitation as TAVR expands to younger lower-risk populations. OBJECTIVES: Using post-implantation computed tomography (CT) scans to evaluate the geometrical relationship between coronary ostia and valve frame in patients undergoing ViV-TAVR with the ACURATE neo valve. METHODS: Post-implant CT scans of 18 out of 20 consecutive patients treated with the ACURATE neo valve were analyzed. Coronary ostia location in relation to the highest plane (HP) (highest point of the ACURATE neo or surgical valve) was determined. Ostia located below the highest plan were further subclassified according to the gap available between the transcatheter heart valve frame and ostium (transcatheter-to-coronary [TTC] distance). The impact implantation depth has on these geometrical relationships was evaluated. RESULTS: A total of 21 out of 36 coronary ostia (58%) were located below the level of the HP with the left coronary artery (36%) more likely to be affected than the right (22%). Further sub-classification of these ostia revealed a large (>6 mm), moderate (4-6 mm), and small (<4 mm) TTC distance in 57% (12/21), 38% (8/21), and in 6% (1/18) of cases, respectively. At an implantation depth <4 mm compared to >4 mm, all ostia were located below the HP with no difference in post-procedural mean gradients (14.5 mmHg ± 4.7 vs. 12.6 mmHg ± 5.8; p = .5, 95%CI 3.8-7.5). CONCLUSIONS: CA following ACURATE neo implantation for ViV-TAVR could potentially be challenging in a significant proportion of patients and specific consideration should be given to the implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Tomografía , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
Eur Radiol ; 31(6): 4031-4041, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33355697

RESUMEN

OBJECTIVES: Enlarged main pulmonary artery diameter (MPAD) resulted to be associated with pulmonary hypertension and mortality in a non-COVID-19 setting. The aim was to investigate and validate the association between MPAD enlargement and overall survival in COVID-19 patients. METHODS: This is a cohort study on 1469 consecutive COVID-19 patients submitted to chest CT within 72 h from admission in seven tertiary level hospitals in Northern Italy, between March 1 and April 20, 2020. Derivation cohort (n = 761) included patients from the first three participating hospitals; validation cohort (n = 633) included patients from the remaining hospitals. CT images were centrally analyzed in a core-lab blinded to clinical data. The prognostic value of MPAD on overall survival was evaluated at adjusted and multivariable Cox's regression analysis on the derivation cohort. The final multivariable model was tested on the validation cohort. RESULTS: In the derivation cohort, the median age was 69 (IQR, 58-77) years and 537 (70.6%) were males. In the validation cohort, the median age was 69 (IQR, 59-77) years with 421 (66.5%) males. Enlarged MPAD (≥ 31 mm) was a predictor of mortality at adjusted (hazard ratio, HR [95%CI]: 1.741 [1.253-2.418], p < 0.001) and multivariable regression analysis (HR [95%CI]: 1.592 [1.154-2.196], p = 0.005), together with male gender, old age, high creatinine, low well-aerated lung volume, and high pneumonia extension (c-index [95%CI] = 0.826 [0.796-0.851]). Model discrimination was confirmed on the validation cohort (c-index [95%CI] = 0.789 [0.758-0.823]), also using CT measurements from a second reader (c-index [95%CI] = 0.790 [0.753;0.825]). CONCLUSION: Enlarged MPAD (≥ 31 mm) at admitting chest CT is an independent predictor of mortality in COVID-19. KEY POINTS: • Enlargement of main pulmonary artery diameter at chest CT performed within 72 h from the admission was associated with a higher rate of in-hospital mortality in COVID-19 patients. • Enlargement of main pulmonary artery diameter (≥ 31 mm) was an independent predictor of death in COVID-19 patients at adjusted and multivariable regression analysis. • The combined evaluation of clinical findings, lung CT features, and main pulmonary artery diameter may be useful for risk stratification in COVID-19 patients.


Asunto(s)
COVID-19 , Arteria Pulmonar , Anciano , Estudios de Cohortes , Femenino , Humanos , Italia/epidemiología , Masculino , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , SARS-CoV-2 , Tomografía Computarizada por Rayos X
9.
Curr Cardiol Rep ; 23(10): 137, 2021 08 19.
Artículo en Inglés | MEDLINE | ID: mdl-34410511

RESUMEN

PURPOSE OF THE REVIEW: Annular-based strategies for treating tricuspid valve (TV) regurgitation do not always have satisfactory long-term outcomes. Management of failed TV annuloplasty can be challenging and requires a dedicated heart team approach. This review explores the treatment options available for failed TV annuloplasty. RECENT FINDINGS: Recent developments and novel percutaneous treatment options have emerged as promising alternatives for patients with failed TV annuloplasty. Leaflet-based interventions, valve-in-valve procedures, transcatheter tricuspid valves and new-generation trans-caval valves are all feasible options, which can assure good results whilst minimizing risks for the patient. Failure of tricuspid annuloplasty is not uncommon amongst patients treated with either a tricuspid ring or suture-based device. The complex anatomy, physiology and clinical risk profile should be carefully evaluated on an individual patient-by-patient basis in order to select the most appropriate clinical and percutaneous treatment strategy. Different transcatheter tricuspid valve repair or replacement techniques may provide an attractive alternative treatment option for managing this challenging patient cohort.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Aórtica , Humanos , Válvula Mitral/cirugía , Recurrencia , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
10.
Catheter Cardiovasc Interv ; 95(1): E30-E36, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31141311

RESUMEN

OBJECTIVES: Left atrial dissection (LatD) is a rare and heterogeneous condition affecting many cardiovascular areas. The present article, by the means of personal case report illustration and systemic review of different clinical management, is aimed to give to clinicians further knowledge on this controversial topic. BACKGROUND: LatD is an exceedingly rare but potentially fatal complication of cardiac surgery or catheter-based interventional procedures. Most of the cases are iatrogenic and its incidence is expected to grow due to an increase in the number of percutaneous coronary intervention and structural heart disease procedures. The management of this complication is controversial, and it may depend on related etiologies. METHODS: We have reported our single-case experience and review of the scientific literature, focusing on the decision-making process and the strategical approach by multimodality imaging techniques. RESULTS: Our case of LatD with initial hemodynamic instability was surgically treated. Conservative approach is often employed in literature despite the fact that conservative versus surgical approach is debatable, depending on clinical presentation, hemodynamic stability, multimodal imaging findings, and personal experience of the center. CONCLUSIONS: According to systematic literature review, a watchful-waiting strategy supported by multimodality imaging could be a safe and effective management in stable LatD.


Asunto(s)
Atrios Cardíacos/cirugía , Lesiones Cardíacas/cirugía , Hematoma/cirugía , Enfermedad Iatrogénica , Intervención Coronaria Percutánea/efectos adversos , Anciano , Función del Atrio Izquierdo , Toma de Decisiones Clínicas , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/lesiones , Atrios Cardíacos/fisiopatología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/fisiopatología , Hematoma/diagnóstico por imagen , Hematoma/etiología , Hematoma/fisiopatología , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Selección de Paciente , Recuperación de la Función , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 93(7): E394-E399, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30536530

RESUMEN

BACKGROUND: Trans-catheter closure of coronary artery fistulae (CAF) has become a successful alternative to cardiac surgery with excellent results and acceptable low rate of complications. Different techniques and devices are available to treat the extreme anatomical variability of CAF. AIM: We retrospectively describe our case series of five patients trans-radially treated using an Amplatzer vascular plug IV (AVP-IV) with telescoping catheter technique. RESULTS: Trans-radial closure of CAF using the "Child in Mother" technique with dedicated catheters to deliver the vascular plugs AVP-IV was successfully performed in all patients, in one case for a complex CAF, an hybrid step approach using coils and plugs was needed. CONCLUSIONS: Trans-radial closure of CAF using AVP-IV and a telescoping catheter appeared to be safe and feasible in our case series. A persistent closure of CAF was achieved in all patients at 2 year coronary angiography follow-up.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Cateterismo Periférico , Anomalías de los Vasos Coronarios/terapia , Embolización Terapéutica/instrumentación , Arteria Radial , Fístula Vascular/terapia , Adulto , Anciano , Aleaciones , Cateterismo Cardíaco/efectos adversos , Catéteres Cardíacos , Cateterismo Periférico/efectos adversos , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/fisiopatología , Embolización Terapéutica/efectos adversos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Punciones , Estudios Retrospectivos , Resultado del Tratamiento , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/fisiopatología
12.
Catheter Cardiovasc Interv ; 93(1): E56-E62, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30244510

RESUMEN

BACKGROUND: Iatrogenic hemorrhagic pericardial tamponade (IHPT) represents a life-threating condition requiring emergency pericardiocentesis. In this clinical context, reinfusion of pericardial blood can stabilize the patient and sustain hemodynamic conditions. AIMS AND METHODS: We reviewed all cases of IHPT occurred at our hospital over a 10 years span. In all patient autologous blood reinfusion through a femoral vein was performed. RESULTS: In our clinical experience of 30 consecutive patients with hemorrhagic cardiac tamponade, this technique was successful to limit blood transfusions, to prevent further clinical worsening and bridge patients with intractable bleeding, to cardiac surgery. No major adverse reactions were directly related to blood autotransfusion. CONCLUSION: In the complex clinical scenario of acute tamponade occurring during catheter-based cardiac procedures, autotransfusion of pericardial blood through a femoral vein is safe and effective. It can be a useful trick up the sleeve of the interventional cardiologist.


Asunto(s)
Transfusión de Sangre Autóloga , Cateterismo Cardíaco/efectos adversos , Taponamiento Cardíaco/terapia , Vena Femoral , Hemorragia/terapia , Enfermedad Iatrogénica , Pericardiocentesis , Anciano , Anciano de 80 o más Años , Transfusión de Sangre Autóloga/efectos adversos , Taponamiento Cardíaco/diagnóstico por imagen , Taponamiento Cardíaco/etiología , Estudios de Factibilidad , Femenino , Hemorragia/diagnóstico por imagen , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Pericardiocentesis/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
13.
Eur Heart J ; 39(26): 2448-2456, 2018 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-29788263

RESUMEN

Aims: Delayed healing and endothelial dysfunction may occur with drug-eluting stents (DES), promoting accelerated infiltration of lipids in the neointima and development of neoatherosclerosis (NA). Pathology data suggest durable polymer (DP) of DES to play a major role in this process. Whether biodegradable polymer (BP) may address these issues is uncertain. We compared in vivo vessel healing and NA of current generation BP- or DP-DES using serial optical coherence tomography (OCT) assessments. Methods and results: Ninety patients with multivessel coronary artery disease were randomized 1:1 to BP everolimus-eluting stents (EES, Synergy) or DP zotarolimus-eluting stents (ZES, Resolute Integrity). Co-primary endpoints were the maximum length of uncovered struts at 3 months (powered for non-inferiority) and the percentage of patients presenting with frames of NA at 18 months (powered for superiority) as measured by OCT. The maximum length of uncovered struts at 3 months was 10 ± 8 mm in the BP-EES group and 11 ± 7 mm in the DP-ZES group (mean difference -1 mm; upper 97.5% confidence interval +2 mm; P = 0.05 for non-inferiority; P = 0.45 for superiority). The percentage of patients presenting with frames of NA at 18 months was low and similar between BP-EES and DP-ZES groups (11.6% vs. 15.9%; P = 0.56). There was no stent thrombosis in both groups at 24 months. Conclusion: BP-EES and DP-ZES showed a similar healing response at 3 months and a low incidence of NA at 18 months. Biocompatible polymers, regardless of whether they are durable or biodegradable, may favourably impact the long-term vascular response to current-generation DES.


Asunto(s)
Implantes Absorbibles , Aterosclerosis/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Neointima/diagnóstico por imagen , Intervención Coronaria Percutánea , Anciano , Materiales Biocompatibles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Everolimus/administración & dosificación , Femenino , Humanos , Inmunosupresores/administración & dosificación , Masculino , Persona de Mediana Edad , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Factores de Tiempo , Tomografía de Coherencia Óptica , Cicatrización de Heridas
16.
Minerva Cardiol Angiol ; 71(1): 35-43, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35332744

RESUMEN

BACKGROUND: The distal radial represents an evolution of the standard radial approach. Distal radial arterial access (DRA) in the so-called "anatomical snuffbox" is technically more difficult but offers potential advantages for patients. Moreover, the use of the distal radial would preserve the proximal radial from the risk of arterial occlusion after interventional procedures performed through the radial artery. METHODS: We enrolled 100 consecutive elective patients undergoing cardiac catheterization (diagnostic or procedural). Arterial access to the distal radial was entirely managed by nursing staff supervised by the interventional cardiologist. In this single-centre single-operator experienced study, the same nurse operator performed puncture, wiring, and sheath advancement. RESULTS: The technical feasibility was 89% and the failure rate occurred in the first 50 cases as evidenced by the learning curve. There were no major complications and the rate of minor complications is in line with that of the radial literature. BMI (OR 1.19; 95% CI: 1.03-1.38), non-radial dominance (OR 3.5; 95% CI: 1.04-12.3) and operator's experience (OR 0.59; 95% CI: 0.35-0.99 for every 20 consecutive cases performed) were associated with DRA failures. CONCLUSIONS: The experience is encouraging and beneficial for all staff and patients with a high percentage of technical success and few mild complications.


Asunto(s)
Curva de Aprendizaje , Intervención Coronaria Percutánea , Humanos , Rol de la Enfermera , Arteria Radial/cirugía , Muñeca , Intervención Coronaria Percutánea/efectos adversos
17.
Front Cardiovasc Med ; 10: 1045702, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36818332

RESUMEN

Background: Heart failure with preserved ejection fraction (HFpEF) is very frequently associated to sleep breathing disorders (SDB). Red blood cell distribution width (RDW) has been shown to be a potential inflammatory index linked to the degree of hypoxia and oxidative stress. Aim: To identify the existence of a possible relationship between sleep apnea, oxygen saturation (SaO2) and RDW in a population of subjects affected by acute HFpEF (AHFpEF). Methods: AHFpEF patients with known history of SDB were enrolled and performed blood chemistry, echocardiography, and 24-h polysomnography (PSG). Results: A total of 34 acute HFpEF patients (mean age 72.8 +/-8.63) were enrolled in the study. A control group of 24 non-HF patients were considered. Compared to controls, HFpEF patients showed a higher mean apnea hypopnea index (AHI), with prevalence of central apneas. A moderate to severe desaturation pattern was observed in AHFpEF vs. controls. RDW was significantly higher in AHFpEF patients vs. controls (mean value 14.7 +/-2.6 % vs. 9.1 +/-2.2, p < 0.05). In AHFpEF, RDW showed a positive correlation with time of SaO2 < 90% (r = 0.35, p = 0.04), and with mean length of apneic events (60 +/-28 s, r = 0.29, p = 0.03). Conclusion: In patients with AHFpEF and SDB, a dependence relationship between RDW and duration of oxygen desaturation was observed, as if oxidative stress and inflammation related to RDW increase could also be linked to severity of sleep disorders in this population.

18.
J Clin Med ; 12(20)2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37892697

RESUMEN

A relationship between malignancy and impaired hemostasis has been proven, and balancing clotting and bleeding risks can be challenging. Half of cancer patients with atrial fibrillation (AF) do not receive any oral anticoagulation (OAC). Using PubMed on the relationship between cancer and AF and their association with hemostasis, targeting studies comparing vitamin K antagonists (VKAs) and direct OAC (DOAC) strategies in AF cancer patients, three RCTs (>3000 patients) and eight observational studies (>250,000 patients) comparing different OACs were retrieved. The VKA prescribed was always warfarin. Dabigatran was the only DOAC not analyzed in the RCTs but the most used in non-randomized studies, whereas edoxaban-treated patients were the majority in the RCTs. Overall, the DOAC patients showed similar or lower rates of efficacy (thromboembolic) and safety (bleeding) outcomes compared to the VKA patients. DOACs are subject to fewer interactions with antineoplastic agents. DOACs may be preferable to VKAs as a thromboembolic prophylaxis in cancer patients with non-valvular AF.

19.
Cancers (Basel) ; 15(9)2023 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-37174043

RESUMEN

(1) Introduction: Cancer and atrial fibrillation (AF) are increasingly coexisting medical challenges. These two conditions share an increased thrombotic and bleeding risk. Although optimal regimens of the most suitable anti-thrombotic therapy are now affirmed in the general population, cancer patients are still particularly understudied on the matter; (2) Aims And Methodology: This metanalysis (11 studies (incl. 266,865 patients)) aims at evaluating the ischemic-hemorrhagic risk profile of oncologic patients with AF treated with oral anticoagulants (vitamin K antagonists vs. direct oral anticoagulants); (3) Results: In the oncological population, DOACs confer a benefit in terms of the reduction in ischemic, hemorrhagic and venous thromboembolic events. However, ischemic prevention has a non-insignificant bleeding risk, lower than Warfarin but significant and higher than the non-oncological patients; (4) Conclusions: Anticoagulation with DOACs provides a higher safety profile with respect to VKAs in terms of stroke reduction and a relative bleeding reduction risk. Further studies are needed to better assess the optimal anticoagulation strategy in cancer patients with AF.

20.
J Clin Med ; 13(1)2023 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-38202217

RESUMEN

BACKGROUND: Stent implantation represents the standard of care in coronary intervention. While a short stent implanted on a focal lesion located on the left anterior descending artery (LAD) seems a reasonable alternative to an internal mammary implant, the same for long stents is still debated. METHODS: We reported the long-term data of 531 consecutive patients who underwent Percutaneous Coronary Intervention (PCI) with long stents in two highly specialized centres. The main inclusion criteria were the implantation of stents longer than 30 mm on the LAD and a minimum follow-up (FU) of five years. The primary endpoint was mortality, and the secondary endpoints were any myocardial infarction (MI), target vessel and lesion revascularization (TVR and TLR, respectively), and stent thrombosis (ST) observed as definite, probable, or possible. RESULTS: In this selected population with characteristics of complex PCI (99.1%), the long-term follow-up (mean 92.18 ± 35.5 months) estimates of all-cause death, cardiovascular death, and any myocardial infarction were 18.3%, 10.5%, and 9.3%, respectively. Both all-cause and cardiovascular deaths are significantly associated with three-vessel disease (HR 6.8; confidence of interval (CI) 95% 3.844-11.934; p < 0.001, and HR 4.7; CI 95% 2.265-9.835; p < 0.001, respectively). Target lesion (TLR) and target vessel revascularization (TVR) are associated with the presence of three-lesion disease on the LAD (HR 3.4; CI 95% 1.984-5.781; p < 0.001; HR 3.9 CI 95% 2.323-6.442; p < 0.001, respectively). Re-PCI for any cause occurred in 31.5% of patients and shows an increased risk for three-lesion stenting (HR 4.3; CI 95% 2.873-6.376; p < 0.001) and the treatment of bifurcation with two stents (HR 1.6; 95% CI 1.051-2.414; p = 0.028). Stent thrombosis rate at the 5-year FU was 4.4% (1.3% definite; 0.9% probable; 2.1% possible), including a 1.7% rate of very-late thrombosis. The stent length superior to 40 mm was not associated with poor outcomes (all-cause death p = 0.349; cardiovascular death p = 0.855; MI p = 0.691; re-PCI p = 0.234; TLR p = 0.805; TVR p = 0.087; ST p = 0.189). CONCLUSION: At an FU of longer than five years, patients treated with stents longer than 30 mm in their LAD showed acceptable procedural results but poor outcomes.

SELECCIÓN DE REFERENCIAS