Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Idioma
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Zhonghua Yi Xue Za Zhi ; 101(41): 3411-3416, 2021 Nov 09.
Artículo en Zh | MEDLINE | ID: mdl-34758545

RESUMEN

Objective: To compare and evaluate the diagnostic performance of visual evaluation and CT maximal density relative enhancement value in the diagnosis of intestinal ischemia complication in patients with closed loop obstruction and to explore the feasibility of CT maximal density relative enhancement value in quantifying the degrees of intestinal ischemia. Methods: The clinical and CT imaging data of 82 patients, 46 males and 36 females, aged from 19 to 78(52±18) years, with closed loop obstruction were retrospectively analyzed in the First Affiliated Hospital of Zhengzhou University from July 2017 to July 2019. All patients were classified into three groups: necrosis group (28 cases), ischemia group (22 cases), non-ischemia group(32 cases) using clinicopathologic results as reference standard. CT visual evaluation was performed by two experienced radiologists. The sensitivity, specificity, positive and negative predictive values and accuracy of the two observers were calculated respectively. The inter-observer agreement was analyzed by kappa analysis. Maximal density relative enhancement value was defined as the difference CT value of an ROI at dilated obstructed loops between contrast-enhanced and unenhanced CT images. The differences among groups were compared by one-way analysis of variance. Diagnostic performances were evaluated by receiver operating characteristic (ROC) curve analysis. Results: The sensitivity, specificity, positive and negative predictive values and accuracy of observer1 were 62.0%, 87.5%, 88.6%, 59.6%, 72.0%, and 58.0%, 93.8%, 93.5%, 58.8%, 72.0%for observer2, respectively. The kappa value of inter-observer agreement was 0.747. The unenhanced CT value of necrosis group, ischemia group and non-ischemia group was (53.7±9.7), (45.7±7.2) and (44.7±7.0) HU, enhanced CT value was (60.5±10.1), (65.0±11.6) and (87.0±15.8) HU, relative enhancement value was(6.8±8.4), (19.2±12.4) and(44.7±16.2)HU, respectively. All had a statistical difference among three groups (all P<0.05). The unenhanced CT value of necrosis group was higher than that of ischemia group and un-ischemia group (both P<0.05). The enhanced CT value of non-ischemia group was higher than that of ischemia group and necrosis (both P<0.05). The relative enhancement value all had a significant difference between groups (all P<0.05). Taking maximal density relative enhancement value below 19.5 HU as diagnosis threshold, the sensitivity, specificity and area under curve(AUC) were 96.9%, 74.0% and 0.947, respectively. Taking enhanced CT value below 66.5 HU as diagnosis threshold, the sensitivity, specificity and AUC were 93.8%, 60.0% and 0.903, respectively; the sensitivity was higher than that of objective visual evaluation. Conclusion: Maximal density relative enhancement value can quantize the bowel wall enhancement, and is a more reliable way in the diagnosis of intestinal ischemia than visual evaluation.


Asunto(s)
Obstrucción Intestinal , Isquemia Mesentérica , Medios de Contraste , Femenino , Humanos , Obstrucción Intestinal/diagnóstico por imagen , Intestino Delgado , Isquemia/diagnóstico por imagen , Masculino , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
2.
Zhonghua Yi Xue Za Zhi ; 98(9): 696-700, 2018 Mar 06.
Artículo en Zh | MEDLINE | ID: mdl-29534407

RESUMEN

Objective: To analyze the effect of preset adaptive statistical iterative reconstruction-V (ASIR-V) on image quality and radiation dose in dual-enhanced abdominal CT and to investigate the optimal ASIR-V in clinic use. Methods: From February 13 to April 30 in 2017, one hundred and eighty patients who received up abdominal CT scan in the First Affiliated Hospital of Zhengzhou University were collected prospectively. All patients underwent arterial phase (AP) and portal venous phase (PVP) enhanced abdominal CT(120 kVp, noise index 10) and were randomly divided into 6 groups according to random number table (A-F, 30 cases in each group). In group A-F, 0-50% preset ASIR-V (an interval of 10%) was applied, respectively. Qualitative parameters (subjective image quality, diagnosis confidence and radiation dose) and quantitative parameters[image noise, CT number and contrast to noise ratio (CNR)]were measured and compared among the groups by using one-way analysis of variance or Kruskal-Wallis H test. Results: The CT dose index volume (CTDIvol) decreased with the increasing of preset ASIR-V. The effective radiation dose (ED) was significant different among groups (F=27.598, P<0.05), and the ED of group B-F dropped by 10.8%, 21.7%, 31.2%, 44.9% and 61.9% respectively when compared with that in group A. Group E showed the optimal image quality (Z=18.675, 27.548, 19.761, all P<0.05) and diagnosis confidence(Z=21.387, 17.693, 22.459, all P<0.05) in plain scan, AP and PVP phases. There was no significant differences in image noise and CT value of liver, pancreas and muscle among groups (F=1.468, 0.337, 0.592, 0.284, all P>0.05). There were significant differences in CNRs in liver and portal vein in PVP phase among the groups (F=3.980, 4.681, both P<0.05). Conclusion: In abdominal CT, 40% preset ASIR-V can provides the best image quality and it can reduce radiation dose for 44.9%.


Asunto(s)
Tomografía Computarizada por Rayos X , Abdomen , Humanos , Vena Porta , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA