Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Am J Dermatopathol ; 46(7): 452-454, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38457692

RESUMEN

ABSTRACT: Hydrophilic polymer embolism from vascular medical devices is an underrecognized clinical entity that can cause deleterious end-organ ischemia and culminate in mortality. This is concerning as we are in the era where minimally invasive procedures are commonplace. Diagnosis is often made retrospectively after obtaining histopathological tissue samples showing endoluminal, cerebriform, amorphous, anucleate, basophilic, nonrefractile, nonpolarizable foreign body material. We detail 2 more cases of cutaneous hydrophilic polymer embolism to underscore its salient clinicopathological features and increase awareness of this important iatrogenic entity.


Asunto(s)
Embolia , Humanos , Embolia/patología , Embolia/etiología , Femenino , Masculino , Polímeros/efectos adversos , Polímeros/química , Anciano , Interacciones Hidrofóbicas e Hidrofílicas , Persona de Mediana Edad , Cuerpos Extraños/patología , Cuerpos Extraños/complicaciones
2.
Am J Otolaryngol ; 45(4): 104297, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38692072

RESUMEN

IMPORTANCE: The symptoms of primary hyperparathyroidism are often subtle, such as fatigue, mood changes, and sleep disturbances. After parathyroidectomy, patients often report improvement in sleep and mood; however, objective data supporting these improvements is lacking. OBJECTIVE: This prospective study uses standard measures to objectively and subjectively assess sleep in patients with primary hyperparathyroidism before and after parathyroidectomy. DESIGN: A longitudinal prospective study was conducted over three one-week-long periods: pre-parathyroidectomy, 1-week post-parathyroidectomy, and three months post-parathyroidectomy. During each time point, patients wore an actigraphy device, recorded a sleep diary, and completed the Pittsburgh Sleep Quality Index (PSQI), Insomnia Severity Index (ISI), and Depression Anxiety Stress Scale (DASS). Statistical analysis was performed using repeated measures models to compare the average measures among the three time points and test for trends over time. SETTING: Single institution, tertiary care center. PARTICIPANTS: Patients with primary hyperparathyroidism from ages 18 to 89 years old. EXPOSURE: Parathyroidectomy between September 2020 and January 2024. MAIN OUTCOMES AND MEASURES: Actigraphy data, consensus sleep diary, Pittsburgh Sleep Quality Index (PSQI), Insomnia Severity Index (ISI), Depression Anxiety Stress Scales - 21 Items (DASS). RESULTS: Thirty-six patients were enrolled, and 34 patients completed the study. Actigraphy data showed a significant negative trend in average sleep latency (p = 0.045) and average time in bed (p = 0.046). Sleep diary data showed additional differences in the number of awakenings (p = 0.002), wake after sleep onset (p < 0.001), sleep quality (p < 0.001), and sleep efficiency (p = 0.02) among the three time points and/or as a significant negative trend. PSQI and ISI scores were significantly different among the three time points (p = 0.002 and p < 0.001, respectively) and also declined significantly over time (p = 0.008 and p = 0.007, respectively). DASS depression, anxiety, and stress scores were significantly different among the three time points (p < 0.001, p = 0.01, and p < 0.001, respectively), and stress also declined significantly over time (p = 0.005). CONCLUSION AND RELEVANCE: This study represents the most extensive prospective study demonstrating objective and subjective sleep and mood improvement in patients with primary hyperparathyroidism after parathyroidectomy.


Asunto(s)
Actigrafía , Hiperparatiroidismo Primario , Paratiroidectomía , Humanos , Hiperparatiroidismo Primario/cirugía , Hiperparatiroidismo Primario/complicaciones , Hiperparatiroidismo Primario/psicología , Persona de Mediana Edad , Masculino , Femenino , Estudios Prospectivos , Anciano , Adulto , Estudios Longitudinales , Anciano de 80 o más Años , Calidad del Sueño , Adulto Joven , Adolescente , Depresión/etiología , Resultado del Tratamiento , Sueño/fisiología , Índice de Severidad de la Enfermedad , Trastornos del Inicio y del Mantenimiento del Sueño/etiología
3.
J Neurosci ; 42(31): 6121-6130, 2022 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-35764380

RESUMEN

Experiences of physical exertion guide our assessments of effort. While these assessments critically influence our decisions to engage in daily activities, little is known about how they are generated. We had female and male human participants exert grip force and assess how effortful these exertions felt; and used magnetic resonance spectroscopy to measure their brain GABA concentration. We found that variability in exertion (i.e., the coefficient of variation in their force exertion profile) was associated with increases in assessments of effort, making participants judge efforts as more costly. GABA levels in the sensorimotor cortex (SM1) moderated the influence of exertion variability on overassessments of effort. In individuals with higher sensorimotor GABA, exertion variability had a diminished influence on overassessments of effort. Essentially, sensorimotor GABA had a protective effect on the influence of exertion variability on inflations of effort assessment. Our findings provide a neurobiological account of how the brain's GABAergic system integrates features of physical exertion into judgments of effort, and how basic sensorimotor properties may influence higher-order judgments of effort.SIGNIFICANCE STATEMENT Feelings of effort critically shape our decisions to partake in activities of daily living. It remains unclear how the brain translates physical activity into judgments about effort (i.e., "How effortful did that activity feel?"). Using modeling of behavior and neuroimaging, we show how the nervous system uses information about physical exertion to generate assessments of effort. We found that higher variability in exertion was associated with increases in assessments of effort, making participants judge efforts as more costly. GABA, the brain's main inhibitory neurotransmitter, moderated the influence of exertion variability on overassessments of effort. These findings illustrate how low-level features of motor performance and sensorimotor neurochemistry influence higher-order cognitive processes related to feelings of effort.


Asunto(s)
Esfuerzo Físico , Corteza Sensoriomotora , Actividades Cotidianas , Mapeo Encefálico , Femenino , Humanos , Masculino , Esfuerzo Físico/fisiología , Corteza Sensoriomotora/fisiología , Ácido gamma-Aminobutírico
4.
Psychooncology ; 32(8): 1147-1162, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37226331

RESUMEN

OBJECTIVES: Continued smoking after cancer diagnosis is associated with worse outcomes, however, many persons diagnosed with cancer who smoke are unable to quit successfully. Effective interventions are needed to promote quitting in this population. The purpose of this systematic review is to understand the most effective interventions for smoking cessation among persons with cancer and to identify gaps in knowledge and methodology to suggest directions for future research. METHODS: Three electronic databases (The Cochrane Central Register of Controlled trials, MEDLINE, and EMBASE) were searched for studies of smoking cessation interventions among persons with cancer, published up to 1 July 2021. Title and abstract screening, full-text review, and data extraction was completed by two independent reviewers, via Covalence software, with any discordance resolved by a third reviewer. A quality assessment was completed using the Cochrane Risk of Bias Tool Version 2. RESULTS: Thirty-six articles were included in the review, including 17 randomized-controlled trials (RCTs) and 19 non-RCT studies. Of the 36 studies, 28 (77.8%) utilized an intervention that included both counseling and medication, with 24 (85.7%) providing medication to participants at no cost. Abstinence rates in the RCT intervention groups (n = 17) ranged from 5.2% to 75%, while the non-RCTs found abstinence rates ranging from 15% to 46%. Overall, studies met a mean of 2.28 out of seven quality items, ranging from 0 to 6. CONCLUSIONS: Our study highlights the importance of utilizing intensive combined behavioral and pharmacological interventions for persons with cancer. While combined therapy interventions seem to be the most effective, more research is needed, as current studies have several quality issues, including the lack of biochemical verification for abstinence.


Asunto(s)
Neoplasias , Cese del Hábito de Fumar , Humanos , Cese del Hábito de Fumar/psicología , Terapia Conductista , Consejo
5.
Magn Reson Med ; 88(4): 1500-1515, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35657035

RESUMEN

PURPOSE: To further develop MultiNet GRAPPA, a neural-network-based reconstruction, for lower SNR proton MRSI (1 H MRSI) data using adapted undersampling schemes and improved training sets. METHODS: 1 H FID-MRSI data and an anatomical image for GRAPPA reconstruction were acquired in two slices in the human brain (n = 6) at 7T. MRSI data were retrospectively undersampled for a 4×, 6×, and 7× acceleration rate. Signal-to-noise, relative error (RE) between accelerated and fully sampled metabolic maps, RMS of the lipid artifacts, and fitting reliability were compared across acceleration rates, to the fully sampled data, and with different kinds and amounts of training images. RESULTS: Training with semi-synthetic images resulted in higher SNR and lower lipid RMS relative to training with acquired images from one or several subjects. SNR increased with the number of semi-synthetic training images and the 4× accelerated data retains ∼30% more SNR than other accelerated data. Spectra reconstructed with 20 semi-synthetic averages retained ∼100% more SNR and had ∼5% lower lipid RMS than those reconstructed with the center k-space points of one image as was originally proposed for very high SNR MRSI data and had higher fitting reliability. The metabolite RE was lowest when training with 20-semi-synthetic training images and highest when training with the center k-space points of one image. CONCLUSION: MultiNet GRAPPA is feasible with lower SNR 1 H MRSI data if 20-semi-synthetic training images are used at a 4× acceleration rate. This acceleration rate provided the best trade-off between scan time and spectral SNR.


Asunto(s)
Encéfalo , Protones , Algoritmos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Calibración , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Lípidos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido
6.
Neuroimage ; 237: 118158, 2021 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-33991699

RESUMEN

While it is widely accepted that motor sequence learning (MSL) is supported by a prefrontal-mediated interaction between hippocampal and striatal networks, it remains unknown whether the functional responses of these networks can be modulated in humans with targeted experimental interventions. The present proof-of-concept study employed a multimodal neuroimaging approach, including functional magnetic resonance (MR) imaging and MR spectroscopy, to investigate whether individually-tailored theta-burst stimulation of the dorsolateral prefrontal cortex can modulate responses in the hippocampus and the basal ganglia during motor learning. Our results indicate that while stimulation did not modulate motor performance nor task-related brain activity, it influenced connectivity patterns within hippocampo-frontal and striatal networks. Stimulation also altered the relationship between the levels of gamma-aminobutyric acid (GABA) in the stimulated prefrontal cortex and learning-related changes in both activity and connectivity in fronto-striato-hippocampal networks. This study provides the first experimental evidence, to the best of our knowledge, that brain stimulation can alter motor learning-related functional responses in the striatum and hippocampus.


Asunto(s)
Núcleo Caudado/fisiología , Conectoma , Potenciales Evocados Motores/fisiología , Hipocampo/fisiología , Actividad Motora/fisiología , Corteza Prefrontal/fisiología , Desempeño Psicomotor/fisiología , Aprendizaje Seriado/fisiología , Estimulación Magnética Transcraneal , Ácido gamma-Aminobutírico/metabolismo , Adulto , Núcleo Caudado/diagnóstico por imagen , Núcleo Caudado/metabolismo , Hipocampo/diagnóstico por imagen , Hipocampo/metabolismo , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Corteza Prefrontal/diagnóstico por imagen , Corteza Prefrontal/metabolismo , Prueba de Estudio Conceptual , Adulto Joven
7.
Magn Reson Med ; 86(6): 2945-2956, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34431549

RESUMEN

PURPOSE: To combine metabolite cycling with J-difference editing (MC MEGA) to allow for prospective frequency correction at each transient without additional acquisitions and compare it to water-suppressed MEGA-PRESS (WS MEGA) editing with intermittent prospective frequency correction. METHODS: Macromolecule-suppressed gamma aminobutyric acid (GABA)-edited experiments were performed in a phantom and in the occipital lobe (OCC) (n = 12) and medial prefrontal cortex (mPFC) (n = 8) of the human brain. Water frequency consistency and average offset over acquisition time were compared. GABA multiplet patterns, signal intensities, and choline subtraction artifacts were evaluated. In vivo GABA concentrations were compared and related to frequency offset in the OCC. RESULTS: MC MEGA was more stable with 21% and 32% smaller water frequency SDs in the OCC and mPFC, respectively. MC MEGA also had 39% and 40% smaller average frequency offsets in the OCC and mPFC, respectively. Phantom GABA multiplet patterns and signal intensities were similar. In vivo GABA concentrations were smaller in MC MEGA than in WS MEGA, with median (interquartile range) of 2.52 (0.27) and 2.29 (0.19) institutional units (i.u.), respectively in the OCC scans without prior DTI, and 0.99 (0.3) and 1.72 (0.5), respectively in the mPFC. OCC WS MEGA GABA concentrations, but not MC MEGA GABA concentrations were moderately correlated with frequency offset. mPFC WS MEGA spectra contained significantly more subtraction artifacts than MC MEGA spectra. CONCLUSION: MC MEGA is feasible and allows for prospective frequency correction at every transient. MC MEGA GABA concentrations were not biased by frequency offsets and contained less subtraction artifacts compared to WS MEGA.


Asunto(s)
Artefactos , Ácido gamma-Aminobutírico , Humanos , Sustancias Macromoleculares , Espectroscopía de Resonancia Magnética , Estudios Prospectivos
8.
Radiology ; 295(1): 171-180, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32043950

RESUMEN

Background The hardware and software differences between MR vendors and individual sites influence the quantification of MR spectroscopy data. An analysis of a large data set may help to better understand sources of the total variance in quantified metabolite levels. Purpose To compare multisite quantitative brain MR spectroscopy data acquired in healthy participants at 26 sites by using the vendor-supplied single-voxel point-resolved spectroscopy (PRESS) sequence. Materials and Methods An MR spectroscopy protocol to acquire short-echo-time PRESS data from the midparietal region of the brain was disseminated to 26 research sites operating 3.0-T MR scanners from three different vendors. In this prospective study, healthy participants were scanned between July 2016 and December 2017. Data were analyzed by using software with simulated basis sets customized for each vendor implementation. The proportion of total variance attributed to vendor-, site-, and participant-related effects was estimated by using a linear mixed-effects model. P values were derived through parametric bootstrapping of the linear mixed-effects models (denoted Pboot). Results In total, 296 participants (mean age, 26 years ± 4.6; 155 women and 141 men) were scanned. Good-quality data were recorded from all sites, as evidenced by a consistent linewidth of N-acetylaspartate (range, 4.4-5.0 Hz), signal-to-noise ratio (range, 174-289), and low Cramér-Rao lower bounds (≤5%) for all of the major metabolites. Among the major metabolites, no vendor effects were found for levels of myo-inositol (Pboot > .90), N-acetylaspartate and N-acetylaspartylglutamate (Pboot = .13), or glutamate and glutamine (Pboot = .11). Among the smaller resonances, no vendor effects were found for ascorbate (Pboot = .08), aspartate (Pboot > .90), glutathione (Pboot > .90), or lactate (Pboot = .28). Conclusion Multisite multivendor single-voxel MR spectroscopy studies performed at 3.0 T can yield results that are coherent across vendors, provided that vendor differences in pulse sequence implementation are accounted for in data analysis. However, the site-related effects on variability were more profound and suggest the need for further standardization of spectroscopic protocols. © RSNA, 2020 Online supplemental material is available for this article.


Asunto(s)
Encéfalo/metabolismo , Comercio , Espectroscopía de Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Masculino , Estudios Prospectivos , Adulto Joven
9.
Neuroimage ; 202: 116141, 2019 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-31479753

RESUMEN

Edited magnetic resonance spectroscopic imaging (MRSI) is capable of mapping the distribution of low concentration metabolites such as gamma-aminobutyric acid (GABA) or and glutathione (GSH), but is prone to subtraction artifacts due to head motion or other instabilities. In this study, a retrospective motion compensation algorithm for edited MRSI is proposed. The algorithm identifies movement-affected signals by comparing residual water and lipid peaks between different transients recorded at the same point in k-space, and either phase corrects, replaces or removes affected spectra prior to spatial Fourier transformation. The method was tested on macromolecule-unsuppressed GABA-edited spin-echo MR spectroscopic imaging data acquired from 8 healthy adults scanned at 3T. Relative to non-motion compensated data sets, the motion compensated data had significantly less subtraction artifacts across subjects. The residual choline (Cho) peak in the spectrum (which is well resolved from as a different chemical shift from GABA and is completely absent in a spectrum without subtraction artifact) was used as a metric of motion artifact severity. The normalized Cho area was 5.14 times lower with motion compensation than without motion compensation. A 'removal-only' version of the technique is also shown to be promising in removing motion-corrupted artifacts in a GSH-edited MRSI acquisition acquired in 1 healthy subject. This study introduces a motion compensation technique and demonstrates that retrospective compensation in k-space is possible and significantly reduces the amount of subtraction artifacts in the resulting edited spectra.


Asunto(s)
Encéfalo/metabolismo , Procesamiento de Imagen Asistido por Computador/métodos , Espectroscopía de Resonancia Magnética/métodos , Adulto , Algoritmos , Artefactos , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Ácido gamma-Aminobutírico/metabolismo
10.
Neuroimage ; 185: 181-190, 2019 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-30296560

RESUMEN

PURPOSE: To demonstrate the framework of a novel Hadamard-encoded spectral editing approach for simultaneously detecting multiple low-concentration brain metabolites in vivo at 3T. METHODS: HERCULES (Hadamard Editing Resolves Chemicals Using Linear-combination Estimation of Spectra) is a four-step Hadamard-encoded editing scheme. 20-ms editing pulses are applied at: (A) 4.58 and 1.9 ppm; (B) 4.18 and 1.9 ppm; (C) 4.58 ppm; and (D) 4.18 ppm. Edited signals from γ-aminobutyric acid (GABA), glutathione (GSH), ascorbate (Asc), N-acetylaspartate (NAA), N-acetylaspartylglutamate (NAAG), aspartate (Asp), lactate (Lac), and likely 2-hydroxyglutarate (2-HG) are separated with reduced signal overlap into distinct Hadamard combinations: (A+B+C+D); (A+B-C-D); and (A-B+C-D). HERCULES uses a novel multiplexed linear-combination modeling approach, fitting all three Hadamard combinations at the same time, maximizing the amount of information used for model parameter estimation, in order to quantify the levels of these compounds. Fitting also allows estimation of the levels of total choline (tCho), myo-inositol (Ins), glutamate (Glu), and glutamine (Gln). Quantitative HERCULES results were compared between two grey- and white-matter-rich brain regions (11 min acquisition time each) in 10 healthy volunteers. Coefficients of variation (CV) of quantified measurements from the HERCULES fitting approach were compared against those from a single-spectrum fitting approach, and against estimates from short-TE PRESS data. RESULTS: HERCULES successfully segregates overlapping resonances into separate Hadamard combinations, allowing for the estimation of levels of seven coupled metabolites that would usually require a single 11-min editing experiment each. Metabolite levels and CVs agree well with published values. CVs of quantified measurements from the multiplexed HERCULES fitting approach outperform single-spectrum fitting and short-TE PRESS for most of the edited metabolites, performing only slightly to moderately worse than the fitting method that gives the lowest CVs for tCho, NAA, NAAG, and Asp. CONCLUSION: HERCULES is a new experimental approach with the potential for simultaneous editing and multiplexed fitting of up to seven coupled low-concentration and six high-concentration metabolites within a single 11-min acquisition at 3T.


Asunto(s)
Encéfalo/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Humanos
11.
Neuroimage ; 191: 537-548, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30840905

RESUMEN

Accurate and reliable quantification of brain metabolites measured in vivo using 1H magnetic resonance spectroscopy (MRS) is a topic of continued interest. Aside from differences in the basic approach to quantification, the quantification of metabolite data acquired at different sites and on different platforms poses an additional methodological challenge. In this study, spectrally edited γ-aminobutyric acid (GABA) MRS data were analyzed and GABA levels were quantified relative to an internal tissue water reference. Data from 284 volunteers scanned across 25 research sites were collected using GABA+ (GABA + co-edited macromolecules (MM)) and MM-suppressed GABA editing. The unsuppressed water signal from the volume of interest was acquired for concentration referencing. Whole-brain T1-weighted structural images were acquired and segmented to determine gray matter, white matter and cerebrospinal fluid voxel tissue fractions. Water-referenced GABA measurements were fully corrected for tissue-dependent signal relaxation and water visibility effects. The cohort-wide coefficient of variation was 17% for the GABA + data and 29% for the MM-suppressed GABA data. The mean within-site coefficient of variation was 10% for the GABA + data and 19% for the MM-suppressed GABA data. Vendor differences contributed 53% to the total variance in the GABA + data, while the remaining variance was attributed to site- (11%) and participant-level (36%) effects. For the MM-suppressed data, 54% of the variance was attributed to site differences, while the remaining 46% was attributed to participant differences. Results from an exploratory analysis suggested that the vendor differences were related to the unsuppressed water signal acquisition. Discounting the observed vendor-specific effects, water-referenced GABA measurements exhibit similar levels of variance to creatine-referenced GABA measurements. It is concluded that quantification using internal tissue water referencing is a viable and reliable method for the quantification of in vivo GABA levels.


Asunto(s)
Encéfalo/metabolismo , Espectroscopía de Resonancia Magnética/normas , Ácido gamma-Aminobutírico/análisis , Adolescente , Adulto , Conjuntos de Datos como Asunto , Femenino , Humanos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Valores de Referencia , Agua , Adulto Joven
12.
Magn Reson Med ; 82(1): 21-32, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30793803

RESUMEN

PURPOSE: To evaluate the feasibility of simultaneous MR spectroscopic imaging (MRSI) of gamma-aminobutyric acid (GABA) and glutathione (GSH) in the human brain using Hadamard Encoding and Reconstruction of MEGA-Edited Spectroscopy (HERMES). METHODS: Point RESolved Spectroscopy (PRESS)-localized MRSI was performed in GABA and GSH phantoms and in the human brain (n = 3) using HERMES editing and compared to conventional MEGA editing of each metabolite. Multiplet patterns, signal intensities, and metabolite crosstalk were compared between methods. GABA+ and GSH levels were compared between methods for bias and variability. Linear regression of HERMES-MRSI GABA+/H2 O and GSH/H2 O versus gray matter (GM) fraction were performed to assess differences between GM and white matter (WM). RESULTS: Phantom HERMES-MRSI scans gave comparable GABA+ and GSH signals to MEGA-MRSI across the PRESS-localized volume. In vivo, HERMES-reconstructed GABA+ and GSH values had minimal measurement bias and variability relative to MEGA-MRSI. Intersubject coefficients of variation (CV) from two regions within the PRESS-localized volume for HERMES and MEGA were 6-12% for GABA+ and 6-19% for GSH. Interregion CVs were 5-15% for GABA+ and 3-17% for GSH. The GABA+/H2 O and GSH/H2 O ratios were ~1.8 times higher and ~1.9 times higher, respectively, in GM than in WM. CONCLUSION: HERMES-MRSI of GABA+ and GSH was found to be practical in the human brain with minimal measurement bias and comparable variability to separate MEGA-edited acquisitions of each metabolite performed in double the scan time. The HERMES-MRSI is a promising method for simultaneously mapping the distribution of multiple low-concentration metabolites.


Asunto(s)
Glutatión , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Ácido gamma-Aminobutírico , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Química Encefálica , Femenino , Glutatión/análisis , Glutatión/química , Glutatión/metabolismo , Humanos , Masculino , Fantasmas de Imagen , Ácido gamma-Aminobutírico/análisis , Ácido gamma-Aminobutírico/química , Ácido gamma-Aminobutírico/metabolismo
13.
Magn Reson Med ; 80(4): 1298-1306, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29446118

RESUMEN

PURPOSE: To develop and investigate a novel water suppression sequence with hypergeometric pulses at 3 T. METHODS: Simulations were used to optimize the delays and amplitudes of 5 hypergeometric prepulses, to minimize the residual water over a range of T1 and B1 values. Single-voxel data with hypergeometric water suppression (HGWS) prepulses were acquired in the centrum semiovale, 2 parietal regions, and insula of 7 subjects, and compared with VAPOR water suppression. Magnetic resonance spectroscopic imaging (MRSI) data using both VAPOR and HGWS prepulses were also collected and compared. Water suppression performance was calculated as the residual water peak height relative to the unsuppressed water peak. MRSI voxel-by-voxel comparison was performed by calculating the ratio between HGWS and VAPOR residual water peaks. RESULTS: In simulations, HGWS and VAPOR are insensitive to B1 and water T1 variations, but with no B1 variation, HGWS has a lower average residual water fraction (0.0033) than that of VAPOR (0.0091). In single-voxel acquisitions, HGWS performs better than VAPOR in all regions with a 2.3-fold to 5.7-fold lower residual water. In MRSI acquisitions, HGWS performs on average 2.3-fold better than VAPOR in 98.9% of the voxels. CONCLUSION: HGWS provides better water suppression than VAPOR in both single-voxel and multivoxel acquisitions with a shorter sequence duration.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Femenino , Humanos , Masculino , Ondas de Radio , Agua/química
14.
Magn Reson Med ; 80(2): 474-479, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29285783

RESUMEN

PURPOSE: To demonstrate simultaneous editing of the two most commonly edited and overlapping signals, γ-aminobutyric acid (GABA), and glutathione (GSH), with Hadamard encoding and reconstruction of MEGA-edited spectroscopy (HERMES) using sLASER localization at 7T. METHODS: Density matrix simulations of HERMES at 7T were carried out and compared with phantom experiments. Additional phantom experiments were performed to characterize the echo time (TE) -dependent modulation of GABA- and GSH-edited HERMES spectra at TE of 80-160 ms. In vivo experiments were performed in 10 healthy volunteers, comparing HERMES (11 min) to sequentially acquired MEGA-sLASER detection of GABA and GSH (2 × 11 min). RESULTS: Simulations of HERMES show GABA- and GSH-edited spectra with negligible levels of crosstalk, and give modest agreement with phantom spectra. The TE series of GABA- and GSH-edited HERMES spectra modulate as a result of T2 relaxation and coupling evolution, with GABA showing a stronger TE-dependence. In vivo HERMES experiments show well-edited GABA and GSH signals. Measured concentrations are not statistically different between HERMES and MEGA-sLASER for GABA (1. 051 ± 0.254 i.u. and 1.053 ± 0.248 i.u; P > 0.985) or GSH (0.300 ± 0.091 i.u. and 0.302 ± 0.093 i.u; P > 0.940). CONCLUSION: Simulated, phantom and in vivo measurements of HERMES show excellent segregation of GABA- and GSH-edited signals, and excellent agreement with separately acquired MEGA-sLASER data. HERMES allows two-fold acceleration of editing while maintaining spectral quality compared with sequentially acquired MEGA-sLASER measurements. Magn Reson Med 80:474-479, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Glutatión/química , Procesamiento de Imagen Asistido por Computador/métodos , Espectroscopía de Protones por Resonancia Magnética/métodos , Ácido gamma-Aminobutírico/química , Adulto , Simulación por Computador , Femenino , Humanos , Masculino , Fantasmas de Imagen
15.
Magn Reson Med ; 80(1): 21-28, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29215137

RESUMEN

PURPOSE: Detection of endogenous metabolites using multiplexed editing substantially improves the efficiency of edited magnetic resonance spectroscopy. Multiplexed editing (i.e., performing more than one edited experiment in a single acquisition) requires a tailored, robust approach for correction of frequency and phase offsets. Here, a novel method for frequency and phase correction (FPC) based on spectral registration is presented and compared against previously presented approaches. METHODS: One simulated dataset and 40 γ-aminobutyric acid-/glutathione-edited HERMES datasets acquired in vivo at three imaging centers were used to test four FPC approaches: no correction; spectral registration; spectral registration with post hoc choline-creatine alignment; and multistep FPC. The performance of each routine for the simulated dataset was assessed by comparing the estimated frequency/phase offsets against the known values, whereas the performance for the in vivo data was assessed quantitatively by calculation of an alignment quality metric based on choline subtraction artifacts. RESULTS: The multistep FPC approach returned corrections that were closest to the true values for the simulated dataset. Alignment quality scores were on average worst for no correction, and best for multistep FPC in both the γ-aminobutyric acid- and glutathione-edited spectra in the in vivo data. CONCLUSIONS: Multistep FPC results in improved correction of frequency/phase errors in multiplexed γ-aminobutyric acid-/glutathione-edited magnetic resonance spectroscopy experiments. The optimal FPC strategy is experiment-specific, and may even be dataset-specific. Magn Reson Med 80:21-28, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Encéfalo/diagnóstico por imagen , Glutatión/química , Espectroscopía de Resonancia Magnética , Ácido gamma-Aminobutírico/química , Algoritmos , Artefactos , Simulación por Computador , Bases de Datos Factuales , Humanos , Procesamiento de Imagen Asistido por Computador , Funciones de Verosimilitud , Neuroimagen , Fantasmas de Imagen , Reproducibilidad de los Resultados , Relación Señal-Ruido
16.
NMR Biomed ; 31(1)2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29073732

RESUMEN

The primary inhibitory neurotransmitter γ-aminobutyric acid (GABA) and the major antioxidant glutathione (GSH) are compounds of high importance for the function and integrity of the human brain. In this study, a method for simultaneous J-difference spectral-edited magnetic resonance spectroscopy (MRS) of GSH and GABA with suppression of macromolecular (MM) signals at 3 T is proposed. MM-suppressed Hadamard encoding and reconstruction of MEGA (Mescher-Garwood)-edited spectroscopy (HERMES) consists of four sub-experiments (TE = 80 ms), with 20-ms editing pulses applied at: (A) 4.56 and 1.9 ppm; (B) 4.56 and 1.5 ppm; (C) 1.9 ppm; and (D) 1.5 ppm. One Hadamard combination (A + B - C - D) yields GSH-edited spectra, and another (A - B + C - D) yields GABA-edited spectra, with symmetric suppression of the co-edited MM signal. MM-suppressed HERMES, conventional HERMES and separate Mescher-Garwood point-resolved spectroscopy (MEGA-PRESS) data were successfully acquired from a (33 mm)3 voxel in the parietal lobe in 10 healthy subjects. GSH- and GABA-edited MM-suppressed HERMES spectra were in close agreement with the respective MEGA-PRESS spectra. Mean GABA (and GSH) estimates were 1.10 ± 0.15 i.u. (0.59 ± 0.12 i.u.) for MM-suppressed HERMES, and 1.13 ± 0.09 i.u. (0.66 ± 0.09 i.u.) for MEGA-PRESS. Mean GABA (and GSH) differences between MM-suppressed HERMES and MEGA-PRESS were -0.03 ± 0.11 i.u. (-0.07 ± 0.11 i.u.). The mean signal-to-noise ratio (SNR) improvement of MM-suppressed HERMES over MEGA-PRESS was 1.45 ± 0.25 for GABA and 1.32 ± 0.24 for GSH. These results indicate that symmetric suppression of the MM signal can be accommodated into the Hadamard editing framework. Compared with sequential single-metabolite MEGA-PRESS experiments, MM-suppressed HERMES allows for simultaneous edited measurements of GSH and GABA without MM contamination in only half the scan time, and SNR is maintained.


Asunto(s)
Glutatión/metabolismo , Sustancias Macromoleculares/metabolismo , Espectroscopía de Resonancia Magnética , Ácido gamma-Aminobutírico/metabolismo , Adulto , Humanos , Masculino , Metaboloma
17.
Neuroimage ; 155: 587-593, 2017 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-28438664

RESUMEN

It has previously been shown that the HERMES method ('Hadamard Encoding and Reconstruction of MEGA-Edited Spectroscopy') can be used to simultaneously edit pairs of metabolites (such as N-acetyl-aspartate (NAA) and N-acetyl aspartyl glutamate (NAAG), or glutathione and GABA). In this study, HERMES is extended for the simultaneous editing of three overlapping signals, and illustrated for the example of NAA, NAAG and Aspartate (Asp). Density-matrix simulations were performed in order to optimize the HERMES sequence. The method was tested in NAA and Asp phantoms, and applied to the centrum semiovale of the nine healthy control subjects that were scanned at 3T. Both simulations and phantom experiments showed similar metabolite multiplet patterns with good segregation of all three metabolites. In vivo measurements show consistent relative signal intensities and multiplet patterns with concentrations in agreement with literature values. Simulations indicate co-editing of glutathione, glutamine, and glutamate, but their signals do not significantly overlap with the detected aspartyl resonances. This study demonstrates that a four-step Hadamard-encoded editing scheme can be used to simultaneously edit three otherwise overlapping metabolites, and can measure NAA, NAAG, and Asp in vivo in the brain at 3T with minimal crosstalk.


Asunto(s)
Ácido Aspártico/análisis , Ácido Aspártico/metabolismo , Dipéptidos/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/metabolismo , Adulto , Ácido Aspártico/análogos & derivados , Simulación por Computador , Femenino , Humanos , Masculino , Fantasmas de Imagen , Adulto Joven
18.
Neuroimage ; 159: 32-45, 2017 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-28716717

RESUMEN

Magnetic resonance spectroscopy (MRS) is the only biomedical imaging method that can noninvasively detect endogenous signals from the neurotransmitter γ-aminobutyric acid (GABA) in the human brain. Its increasing popularity has been aided by improvements in scanner hardware and acquisition methodology, as well as by broader access to pulse sequences that can selectively detect GABA, in particular J-difference spectral editing sequences. Nevertheless, implementations of GABA-edited MRS remain diverse across research sites, making comparisons between studies challenging. This large-scale multi-vendor, multi-site study seeks to better understand the factors that impact measurement outcomes of GABA-edited MRS. An international consortium of 24 research sites was formed. Data from 272 healthy adults were acquired on scanners from the three major MRI vendors and analyzed using the Gannet processing pipeline. MRS data were acquired in the medial parietal lobe with standard GABA+ and macromolecule- (MM-) suppressed GABA editing. The coefficient of variation across the entire cohort was 12% for GABA+ measurements and 28% for MM-suppressed GABA measurements. A multilevel analysis revealed that most of the variance (72%) in the GABA+ data was accounted for by differences between participants within-site, while site-level differences accounted for comparatively more variance (20%) than vendor-level differences (8%). For MM-suppressed GABA data, the variance was distributed equally between site- (50%) and participant-level (50%) differences. The findings show that GABA+ measurements exhibit strong agreement when implemented with a standard protocol. There is, however, increased variability for MM-suppressed GABA measurements that is attributed in part to differences in site-to-site data acquisition. This study's protocol establishes a framework for future methodological standardization of GABA-edited MRS, while the results provide valuable benchmarks for the MRS community.


Asunto(s)
Encéfalo/metabolismo , Espectroscopía de Resonancia Magnética/normas , Ácido gamma-Aminobutírico/análisis , Adulto , Conjuntos de Datos como Asunto , Femenino , Humanos , Espectroscopía de Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/métodos , Masculino , Adulto Joven
19.
Magn Reson Med ; 77(2): 498-504, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-26918659

RESUMEN

PURPOSE: To investigate the echo time (TE) dependence of J-difference editing of glutathione and to determine the optimal TE for in vivo measurements at 3T. METHODS: Spatially resolved density-matrix simulations and phantom experiments were performed at a range of TEs to establish the spatial and TE modulation of glutathione signals in editing-on, editing-off, and difference spectra at 3T. In vivo data were acquired in five healthy subjects to compare a TE of 68 ms and a TE of 120 ms. At the longer TE, high-bandwidth, frequency-modulated, slice-selective refocusing pulses were also compared with conventional amplitude-modulated pulses. RESULTS: Simulations and relaxation-corrected phantom experiments suggest that the maximum edited signal occurs at TE 160 ms, ignoring transverse relaxation. Considering in vivo T2 relaxation times of 67-89 ms, the optimal in vivo TE is estimated to be 120 ms. In vivo measurements showed that this TE yielded 15% more signal than TE 68 ms. A further gain of 57% resulted from using improved slice-selective refocusing pulses. CONCLUSION: J-difference editing of glutathione using TE 120 ms delivers increased signal due to improved editing efficiency that more than offsets T2 losses. The additional TE also allows for use of improved slice-selective refocusing pulses, which results in additional signal gains. Magn Reson Med 77:498-504, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Algoritmos , Química Encefálica , Glutatión/análisis , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Imagen Molecular/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Femenino , Humanos , Masculino , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
Magn Reson Med ; 77(1): 16-22, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27851878

RESUMEN

PURPOSE: To develop J-difference editing with parallel reconstruction in accelerated multivoxel (PRIAM) for simultaneous measurement in two separate brain regions of γ-aminobutyric acid (GABA) or glutathione. METHODS: PRIAM separates signals from two simultaneously excited voxels using receiver-coil sensitivity profiles. PRIAM was implemented into Mescher-Garwood (MEGA) edited experiments at 3 Tesla (T), and validated by acquiring dual-voxel MEGA-PRIAM (and compared with conventional single-voxel MEGA-PRESS) spectra from a GABA/glutathione phantom, and 11 healthy participants. RESULTS: MEGA-PRIAM effectively separated phantom spectra with ∼3-4% between-voxel contamination. GABA and glutathione measurements agreed well with those obtained using single-voxel MEGA-PRESS (mean difference was below 2% in GABA levels, and below 7% in glutathione levels). In vivo, GABA- and glutathione-edited spectra were successfully reconstructed with a mean in vivo g-factor of 1.025 (typical voxel-center separation: 7-8 cm). MEGA-PRIAM experiments showed higher signal-to-noise ratio than sequential single-voxel experiments of the same total duration (mean improvement 1.38 ± 0.24). CONCLUSIONS: Simultaneous acquisition of J-difference-edited GABA or glutathione spectra from two voxels is feasible at 3 T. MEGA-PRIAM increases data acquisition rates compared with MEGA-PRESS by a factor of 2. Magn Reson Med, 2016. © 2016 International Society for Magnetic Resonance in Medicine.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA