Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Spine J ; 30(12): 3763-3770, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34562177

RESUMEN

PURPOSE: Sacropelvic fixation is frequently used in combination with thoracolumbar instrumentation for the correction of severe spinal deformities. The purpose of this study was to explore the effects of the triangular titanium implants on the iliac screw fixation. Our hypothesis was that the use of triangular titanium implants can increase the stability of the iliac screw fixation. METHODS: Three T10-pelvis instrumented models were created: pedicle screws and rods in T10-S1, and bilateral iliac screws (IL); posterior fixation and bilateral iliac screws and triangular implants inserted bilaterally in a sacro-alar-iliac trajectory (IL-Tri-SAI); posterior fixation and bilateral iliac screws and two bilateral triangular titanium implants inserted in a lateral trajectory (IL-Tri-Lat). Outputs of these models, such as hardware stresses, were compared against a model with pedicle screws and rods in T10-S1 (PED). RESULTS: Sacropelvic fixation decreased the L5-S1 motion by 75-90%. The motion of the SIJ was reduced by 55-80% after iliac fixation; the addition of triangular titanium implants further reduced it. IL, IL-Tri-SAI and IL-Tri-Lat demonstrated lower S1 pedicle stresses with respect to PED. Triangular implants had a protective effect on the iliac screw stresses. CONCLUSION: Sacropelvic fixation decreased L5-S1 range of motion suggesting increased stability of the joint. The combination of triangular titanium implants and iliac screws reduced the residual flexibility of the sacroiliac joint, and resulted in a protective effect on the S1 pedicle screws and iliac screws themselves. Clinical studies may be performed to demonstrate applicability of these FEA results to patient outcomes.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Humanos , Ilion/cirugía , Vértebras Lumbares , Sacro , Titanio
2.
J Biomech Eng ; 139(9)2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28633164

RESUMEN

Computational models of diarthrodial joints serve to inform the biomechanical function of these structures, and as such, must be supplied appropriate inputs for performance that is representative of actual joint function. Inputs for these models are sourced from both imaging modalities as well as literature. The latter is often the source of mechanical properties for soft tissues, like ligament stiffnesses; however, such data are not always available for all the soft tissues nor is it known for patient-specific work. In the current research, a method to improve the ligament stiffness definition for a computational foot/ankle model was sought with the greater goal of improving the predictive ability of the computational model. Specifically, the stiffness values were optimized using artificial neural networks (ANNs); both feedforward and radial basis function networks (RBFNs) were considered. Optimal networks of each type were determined and subsequently used to predict stiffnesses for the foot/ankle model. Ultimately, the predicted stiffnesses were considered reasonable and resulted in enhanced performance of the computational model, suggesting that artificial neural networks can be used to optimize stiffness inputs.


Asunto(s)
Tobillo , Pie , Ligamentos , Fenómenos Mecánicos , Redes Neurales de la Computación , Modelación Específica para el Paciente , Fenómenos Biomecánicos , Humanos
3.
Foot Ankle Int ; 34(3): 426-33, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23520301

RESUMEN

BACKGROUND: Displaced medial malleolus fractures require surgical repair because of the critical role the structure plays in normal joint function. Various approaches exist, but options are limited for small fragment fractures. This study compared repair with the Medial Malleolar Sled fixation system (Trimed, Inc, Valencia, CA) to lag screws in 2 modes of biomechanical loading in a cadaveric model. METHODS: A Müller type B medial malleolus fracture was simulated on matched pairs of cadaveric lower extremities and repaired with the sled or 2 cancellous lag screws. Tibial distraction (tension, n = 10) or internal rotation (torsion, n = 11) was applied. Fragment movement was measured in the sagittal (tension and torsion) and transverse (torsion-only) planes. Fragment movement at 1 mm and 2 mm (clinical malunion) of gapping during tension and at 2, 4, 6, and 8 N-m during torsion was analyzed via paired t tests. RESULTS: In tension, the load at the 2-mm gap was statistically lower for screws (P = .026). Opening angle was statistically larger for the sled at the 1-mm (P = .0004) and 2-mm (P = .008) gap. In torsion, gapping was statistically lower for the sled (ranging from P = .0013 at 4 N-m to P = .0187 at 8 N-m). No differences were detected for opening angle or transverse plane movement. CONCLUSION: The sled appeared stronger in tension and as effective as lag screws in torsion. The sled may be a viable option for fractures too small for 4.0- or 3.5-mm lag screws. CLINICAL RELEVANCE: The sled may be suitable in applications where a tension band would normally be considered and may provide stronger fixation in osteoporotic bone compared with lag screw fixation.


Asunto(s)
Traumatismos del Tobillo/cirugía , Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Fracturas de la Tibia/cirugía , Adulto , Anciano , Fenómenos Biomecánicos , Densidad Ósea , Hilos Ortopédicos , Cadáver , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Torque
4.
Int J Spine Surg ; 17(1): 122-131, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36574987

RESUMEN

BACKGROUND: The sacroiliac joint (SIJ) transfers the load of the upper body to the lower extremities while allowing a variable physiological movement among individuals. The axis of rotation (AoR) and center of rotation (CoR) of the SIJ can be evaluated to analyze the stability of the SIJ, including when the sacrum is fixed. The purpose of this study was to determine how load intensity affects the SIJ for the intact model and to characterize how sacropelvic fixation performed with different techniques affects this joint. METHODS: Five T10-pelvis models were used: (1) intact model; (2) pedicle screws and rods in T10-S1; (3)pedicle screws and rods in T10-S1, and bilateral S2 alar-iliac screws (S2AI); (4) pedicle screws and rods in T10-S1, bilateral S2AI screws, and triangular implants inserted bilaterally in a sacral alar-iliac trajectory ; and (5) pedicle screws and rods in T10-S1, bilateral S2AI screws, and 2 bilateral triangular implants inserted in a lateral trajectory. Outputs of these models under flexion-extension were compared: AoR and CoR of the SIJ at incremental steps from 0 to 7.5 Nm for the intact model and AoR and CoR of the SIJ for the instrumented models at 7.5 Nm. RESULTS: The intact model was validated against an in vivo study by comparing range of motion and displacement of the sacrum. Increasing the load intensity for the intact model led to an increase of the rotation of the sacrum but did not change the CoR. Comparison among the instrumented models showed that sacropelvic fixation techniques reduced the rotation of the sacrum and stabilized the SIJ, in particular with triangular implants. CONCLUSION: The study outcomes suggest that increasing load intensity increases the rotation of the sacrum but does not influence the CoR, and use of sacropelvic fixation increases the stability of the SIJ, especially when triangular implants are employed. CLINICAL RELEVANCE: The choice of the instrumentation strategy for sacropelvic fixation affects the stability of the construct in terms of both range of motion and axes of rotation, with direct consequences on the risk of failure and mobilization. Clinical studies should be performed to confirm these biomechanical findings.

5.
Int J Spine Surg ; 17(4): 598-606, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37460239

RESUMEN

BACKGROUND: Sacropelvic fixation is frequently combined with thoracolumbar instrumentation for correcting spinal deformities. This study aimed to characterize sacropelvic fixation techniques using novel porous fusion/fixation implants (PFFI). METHODS: Three T10-pelvis finite element models were created: (1) pedicle screws and rods in T10-S1, PFFI bilaterally in S2 alar-iliac (S2AI) trajectory; (2) fixation in T10-S1, PFFI bilaterally in S2AI trajectory, triangular implants bilaterally above the PFFI in a sacro-alar-iliac trajectory (PFFI-IFSAI); and (3) fixation in T10-S1, PFFI bilaterally in S2AI trajectory, PFFI in sacro-alar-iliac trajectory stacked cephalad to those in S2AI position (2-PFFI). Models were loaded with pure moments of 7.5 Nm in flexion-extension, lateral bending, and axial rotation. Outputs were compared against 2 baseline models: (1) pedicle screws and rods in T10-S1 (PED), and (2) pedicle screws and rods in T10-S1, and S2AI screws. RESULTS: PFFI and S2AI resulted in similar L5-S1 motion; adding another PFFI per side (2-PFFI) further reduced this motion. Sacroiliac joint (SIJ) motion was also similar between PFFI and S2AI; PFFI-IFSAI and 2-PFFI demonstrated a further reduction in SIJ motion. Additionally, PFFI reduced max stresses on S1 pedicle screws and on implants in the S2AI position. CONCLUSION: The study shows that supplementing a long construct with PFFI increases the stability of the L5-S1 and SIJ and reduces stresses on the S1 pedicle screws and implants in the S2AI position. CLINICAL RELEVANCE: The findings suggest a reduced risk of pseudarthrosis at L5-S1 and screw breakage. Clinical studies may be performed to demonstrate applicability to patient outcomes. LEVEL OF EVIDENCE: Not applicable (basic science study).

6.
Global Spine J ; : 21925682221141874, 2022 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-36421053

RESUMEN

STUDY DESIGN: Basic science (finite element analysis). OBJECTIVES: Pedicle subtraction osteotomy (PSO) at L5 is an effective treatment for sagittal imbalance, especially in select cases of patients showing kyphosis with the apex at L4-L5 but has been scarcely investigated. The aim of this study was to simulate various "high-demand" instrumentation approaches, including varying numbers of rods and sacropelvic implants, for the stabilization of a PSO at L5. METHODS: A finite element model of T10-pelvis was modified to simulate posterior fixation with pedicle screws and rods from T10 to S1, alone or in combination with an L5 PSO. Five additional configurations were then created by employing rods and novel porous fusion/fixation implants across the sacroiliac joints, in varying numbers. All models were loaded using pure moments of 7.5 Nm in flexion-extension, lateral bending, and axial rotation. RESULTS: The osteotomy resulted in a general increase in motion and stresses in posterior rods and S1 pedicle screws. When the number of rods was varied, three- and four-rod configurations were effective in limiting the maximal rod stresses; values approached those of posterior fixation with no osteotomy. Maximum stresses in the accessory rods were similar to or less than those observed in the primary rods. Multiple sacropelvic implants were effective in reducing range of motion, particularly of the SIJ. CONCLUSIONS: Multi-rod constructs and sacropelvic fixation generally reduced maximal implant stresses and motion in comparison with standard posterior fixation, suggesting a reduced risk of rod breakage and increased joint stability, respectively, when a high-demand construct is utilized for the correction of sagittal imbalance.

7.
Spine J ; 20(10): 1717-1724, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32502655

RESUMEN

BACKGROUND CONTEXT: Long thoracolumbar fixation and fusion have become a consolidated treatment for severe spinal disorders. Concomitant sacropelvic fixation with S2 alar-iliac (S2AI) screws is frequently performed to limit instrumentation failure and pseudarthrosis at the lumbosacral junction. PURPOSE: This study explored the use of triangular titanium implants in different configurations in which the implants supplemented standard sacropelvic fixation with S2AI screws in order to further increase the stability of S2AI fixation. STUDY DESIGN: Finite element study. METHODS: Four T10-pelvis instrumented models were built: pedicle screws and rods in T10-S1 (PED); pedicle screws and rods in T10-S1, and bilateral S2 alar-iliac screws (S2AI); pedicle screws and rods in T10-S1, bilateral S2AI screws, and triangular implants inserted bilaterally in a sacral alar-iliac trajectory (Tri-SAI); pedicle screws and rods in T10-S1, bilateral S2AI screws and two bilateral triangular titanium implants inserted in a lateral trajectory (Tri-Lat). The models were tested under pure moments of 7.5 Nm in flexion-extension, lateral bending and axial rotation. RESULTS: SIJ motion was reduced by 50% to 66% after S2AI fixation; the addition of triangular titanium implants in either a SAI or a lateral trajectory further reduced it. S2AI, Tri-SAI, and Tri-Lat resulted in significantly lower stresses in S1 pedicle screws when compared to PED. Triangular implants had a protective effect on the maximal stresses in S2AI screws, especially when placed in the SAI trajectory. Sacropelvic fixation did not have any protective effect on the posterior rods. CONCLUSIONS: Supplementing S2AI screws with triangular implants had a protective effect on the S2AI screws themselves, as well as the S1 pedicle screws, in the tested model. CLINICAL SIGNIFICANCE: Triangular implants can substantially reduce the residual flexibility of the SIJ with respect to S2AI fixation alone, suggesting a possible role in patients needing reinforced fixation. In vivo investigation is needed to determine if these in vitro effects translate into clinically important differences.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Análisis de Elementos Finitos , Humanos , Ilion , Sacro/cirugía
8.
JOR Spine ; 2(4): e1067, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31891117

RESUMEN

For those patients who suffer from low back pain generated by the sacroiliac (SI) joint, fusion of the SI joint has proven to be an effective means of stabilizing it and reducing pain. Though it has shown promise, SI joint fusion raises clinical questions regarding its effect on neighboring joints such as the hip. As such, the purpose of this study was to determine the effects of SI joint fixation on the hip. A finite element spine-sacroiliac-hip (SSIH) model was developed and its functionality was verified against SI joint range of motion (ROM) and hip contact stress, respectively. The intact model was fixed in double leg stance at the distal femora, and loading was applied at the lumbar spine to simulate stance, flexion, extension, right and left lateral bending, and right and left axial rotation. Functionality was confirmed by measuring and comparing SI joint ROM and contact stress and area at the hip with data from the literature. Following verification of the intact SSIH model, both unilateral and bilateral SI joint fixation were modeled; hip contact stress and area were compared to the intact state. Average hip contact stress was ~2 MPa, with most motions resulting in changes less than 5% relative to intact; contact area changed less than 10% for any motion. Clinical significance: these results demonstrated that SI joint fixation with triangular titanium implants imparted little change in stress at the hip, which suggests that the risk of developing adjacent segment disease is likely low. Future clinical studies may be executed to confirm the results of this computational study.

9.
Comput Math Methods Med ; 2017: 3602928, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28250804

RESUMEN

Computational models are useful tools to study the biomechanics of human joints. Their predictive performance is heavily dependent on bony anatomy and soft tissue properties. Imaging data provides anatomical requirements while approximate tissue properties are implemented from literature data, when available. We sought to improve the predictive capability of a computational foot/ankle model by optimizing its ligament stiffness inputs using feedforward and radial basis function neural networks. While the former demonstrated better performance than the latter per mean square error, both networks provided reasonable stiffness predictions for implementation into the computational model.


Asunto(s)
Articulación del Tobillo/anatomía & histología , Pie/anatomía & histología , Ligamentos/anatomía & histología , Modelos Anatómicos , Redes Neurales de la Computación , Algoritmos , Fenómenos Biomecánicos , Simulación por Computador , Humanos , Neuronas/patología , Distribución Normal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA