Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 92(7): 5311-5318, 2020 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-32142258

RESUMEN

Automated genotyping of drug-resistant Mycobacterium tuberculosis (MTB) directly from sputum is challenging for three primary reasons. First, the sample matrix, sputum, is highly viscous and heterogeneous, posing a challenge for sample processing. Second, acid-fast MTB bacilli are difficult to lyse. And third, there are hundreds of MTB mutations that confer drug resistance. An additional constraint is that MTB is most prevalent where test affordability is paramount. We address the challenge of sample homogenization and cell lysis using magnetic rotation of an external magnet, at high (5000) rpm, to induce the rotation of a disposable stir disc that causes chaotic mixing of glass beads ("MagVor"). Nucleic acid is purified using a pipet tip with an embedded matrix that isolates nucleic acid ("TruTip"). We address the challenge of cost and genotyping multiple mutations using 203 porous three-dimensional gel elements printed on a film substrate and enclosed in a microfluidic laminate assembly ("Lab-on-a-Film"). This Lab-on-a-Film assembly (LFA) serves as a platform for amplification, hybridization, washing, and fluorescent imaging, while maintaining a closed format to prevent amplicon contamination of the workspace. We integrated and automated MagVor homogenization, TruTip purification, and LFA amplification in a multisample, sputum-to-genotype system. Using this system, we report detection down to 43 cfu/mL of MTB bacilli from raw sputum.


Asunto(s)
Automatización , Dispositivos Laboratorio en un Chip , Mycobacterium tuberculosis/genética , Imagen Óptica , Esputo/microbiología , Tuberculosis Resistente a Múltiples Medicamentos/diagnóstico por imagen , Genotipo , Humanos , Imagen Óptica/instrumentación
2.
J Clin Microbiol ; 56(3)2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29305543

RESUMEN

There is a growing awareness that molecular diagnostics for detect-to-treat applications will soon need a highly multiplexed mutation detection and identification capability. In this study, we converted an open-amplicon microarray hybridization test for multidrug-resistant (MDR) Mycobacterium tuberculosis into an entirely closed-amplicon consumable (an amplification microarray) and evaluated its performance with matched sputum and sediment extracts. Reproducible genotyping (the limit of detection) was achieved with ∼25 M. tuberculosis genomes (100 fg of M. tuberculosis DNA) per reaction; the estimated shelf life of the test was at least 18 months when it was stored at 4°C. The test detected M. tuberculosis in 99.1% of sputum extracts and 100% of sediment extracts and showed 100% concordance with the results of real-time PCR. The levels of concordance between M. tuberculosis and resistance-associated gene detection were 99.1% and 98.4% for sputum and sediment extracts, respectively. Genotyping results were 100% concordant between sputum and sediment extracts. Relative to the results of culture-based drug susceptibility testing, the test was 97.1% specific and 75.0% sensitive for the detection of rifampin resistance in both sputum and sediment extracts. The specificity for the detection of isoniazid (INH) resistance was 98.4% and 96.8% for sputum and sediment extracts, respectively, and the sensitivity for the detection of INH resistance was 63.6%. The amplification microarray reported the correct genotype for all discordant phenotype/genotype results. On the basis of these data, primary sputum may be considered a preferred specimen for the test. The amplification microarray design, shelf life, and analytical performance metrics are well aligned with consensus product profiles for next-generation drug-resistant M. tuberculosis diagnostics and represent a significant ease-of-use advantage over other hybridization-based tests for diagnosing MDR tuberculosis.


Asunto(s)
Técnicas de Genotipaje/métodos , Sedimentos Geológicos/microbiología , Mycobacterium tuberculosis/genética , Análisis de Secuencia por Matrices de Oligonucleótidos , Esputo/microbiología , Tuberculosis Resistente a Múltiples Medicamentos/diagnóstico , Antituberculosos/farmacología , Farmacorresistencia Bacteriana Múltiple/genética , Genes MDR/genética , Genotipo , Humanos , Isoniazida/farmacología , Pruebas de Sensibilidad Microbiana , Técnicas Analíticas Microfluídicas , Mycobacterium tuberculosis/efectos de los fármacos , Mycobacterium tuberculosis/aislamiento & purificación , Rifampin/farmacología , Sensibilidad y Especificidad
3.
J Clin Microbiol ; 52(6): 2100-7, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24719444

RESUMEN

We developed a simplified microarray test for detecting and identifying mutations in rpoB, katG, inhA, embB, and rpsL and compared the analytical performance of the test to that of phenotypic drug susceptibility testing (DST). The analytical sensitivity was estimated to be at least 110 genome copies per amplification reaction. The microarray test correctly detected 95.2% of mutations for which there was a sequence-specific probe on the microarray and 100% of 96 wild-type sequences. In a blinded analysis of 153 clinical isolates, microarray sensitivity for first-line drugs relative to phenotypic DST (true resistance) was 100% for rifampin (RIF) (14/14), 90.0% for isoniazid (INH) (36/40), 70% for ethambutol (EMB) (7/10), and 89.1% (57/64) combined. Microarray specificity (true susceptibility) for first-line agents was 95.0% for RIF (132/139), 98.2% for INH (111/113), and 98.6% for EMB (141/143). Overall microarray specificity for RIF, INH, and EMB combined was 97.2% (384/395). The overall positive and negative predictive values for RIF, INH, and EMB combined were 84.9% and 98.3%, respectively. For the second-line drug streptomycin (STR), overall concordance between the agar proportion method and microarray analysis was 89.5% (137/153). Sensitivity was 34.8% (8/23) because of limited microarray coverage for STR-conferring mutations, and specificity was 99.2% (129/130). All false-susceptible discrepant results were a consequence of DNA mutations that are not represented by a specific microarray probe. There were zero invalid results from 220 total tests. The simplified microarray system is suitable for detecting resistance-conferring mutations in clinical M. tuberculosis isolates and can now be used for prospective trials or integrated into an all-in-one, closed-amplicon consumable.


Asunto(s)
Antituberculosos/farmacología , Farmacorresistencia Bacteriana , Técnicas de Genotipaje/métodos , Análisis por Micromatrices/métodos , Mycobacterium tuberculosis/efectos de los fármacos , Mycobacterium tuberculosis/genética , Tuberculosis Resistente a Múltiples Medicamentos/diagnóstico , Genes Bacterianos , Humanos , Pruebas de Sensibilidad Microbiana/métodos , Mutación , Sensibilidad y Especificidad
4.
bioRxiv ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38798454

RESUMEN

Despite decades of research, acute myeloid leukemia (AML) remains a remarkably lethal malignancy. While pediatric AML (pAML) carries a more favorable prognosis than adult AML, the past 25 years of large clinical trials have produced few improvements in pAML survival. Nowhere is this more evident than in patients carrying a t(16;21)(p11;q22) translocation, which yields the FUS::ERG fusion transcript. Patients with FUS::ERG-positive AML are often primary refractory, and most responders quickly relapse. In COG clinical trials, allogeneic stem cell transplantation was of no benefit to FUS::ERG pAML patients; 100% of transplanted patients succumbed to their disease. Expression of major histocompatibility complex (MHC) class I & II and costimulatory molecules is absent at diagnosis in FUS::ERG AML, mirroring the epigenetic mechanism of post-transplant relapse seen in adult AML and its associated dismal outcomes. Here we show that this class-defining immune-repressive phenotype is driven by overexpression of the EZH2 histone lysine methyltransferase in vitro and in multiple clinical cohorts. We show that treatment with the FDA-approved EZH2 inhibitor tazemetostat along with IFN-γ reverses this phenotype, re-establishes MHC presentation, and severely impairs the viability of FUS::ERG AML cells. EZH2 inhibitors may thus provide the first targeted therapeutic option for patients with this high-risk subtype of pAML, with particular benefit as a bridge to successful allogeneic stem cell transplantation.

5.
Appl Environ Microbiol ; 79(3): 799-807, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23160129

RESUMEN

The objectives of this study were to unify amplification, labeling, and microarray hybridization chemistries within a single, closed microfluidic chamber (an amplification microarray) and verify technology performance on a series of groundwater samples from an in situ field experiment designed to compare U(VI) mobility under conditions of various alkalinities (as HCO(3)(-)) during stimulated microbial activity accompanying acetate amendment. Analytical limits of detection were between 2 and 200 cell equivalents of purified DNA. Amplification microarray signatures were well correlated with 16S rRNA-targeted quantitative PCR results and hybridization microarray signatures. The succession of the microbial community was evident with and consistent between the two microarray platforms. Amplification microarray analysis of acetate-treated groundwater showed elevated levels of iron-reducing bacteria (Flexibacter, Geobacter, Rhodoferax, and Shewanella) relative to the average background profile, as expected. Identical molecular signatures were evident in the transect treated with acetate plus NaHCO(3), but at much lower signal intensities and with a much more rapid decline (to nondetection). Azoarcus, Thaurea, and Methylobacterium were responsive in the acetate-only transect but not in the presence of bicarbonate. Observed differences in microbial community composition or response to bicarbonate amendment likely had an effect on measured rates of U reduction, with higher rates probable in the part of the field experiment that was amended with bicarbonate. The simplification in microarray-based work flow is a significant technological advance toward entirely closed-amplicon microarray-based tests and is generally extensible to any number of environmental monitoring applications.


Asunto(s)
Bacterias/clasificación , Bacterias/genética , Biota , Agua Subterránea/microbiología , Metagenómica/métodos , Análisis por Micromatrices/métodos , Acetatos/metabolismo , ADN Bacteriano/genética , ARN Ribosómico 16S/genética , Sensibilidad y Especificidad , Bicarbonato de Sodio/metabolismo
6.
Anal Biochem ; 421(2): 526-33, 2012 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-22033291

RESUMEN

By modifying polymer compositions and cross-linking reagents, we have developed a simple yet effective manufacturing strategy for copolymerized three-dimensional gel element arrays. A new gel-forming monomer, 2-(hydroxyethyl) methacrylamide (HEMAA), was used. HEMAA possesses low volatility and improves the stability of copolymerized gel element arrays to on-chip thermal cycling procedures relative to previously used monomers. Probe immobilization efficiency within the new polymer was 55%, equivalent to that obtained with acrylamide (AA) and methacrylamide (MA) monomers. Nonspecific binding of single-stranded targets was equivalent for all monomers. Increasing cross-linker chain length improved hybridization kinetics and end-point signal intensities relative to N,N-methylenebisacrylamide (Bis). The new copolymer formulation was successfully applied to a model orthopox array. Because HEMAA greatly simplifies gel element array manufacture, we expect it (in combination with new cross-linkers described here) to find widespread application in microarray science.


Asunto(s)
Geles , Metacrilatos/química , Análisis de Secuencia por Matrices de Oligonucleótidos , Secuencia de Bases , Cinética , Sondas de Oligonucleótidos , Reacción en Cadena de la Polimerasa , Volatilización
7.
Nat Metab ; 4(9): 1150-1165, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36097183

RESUMEN

Studies in genetically 'identical' individuals indicate that as much as 50% of complex trait variation cannot be traced to genetics or to the environment. The mechanisms that generate this 'unexplained' phenotypic variation (UPV) remain largely unknown. Here, we identify neuronatin (NNAT) as a conserved factor that buffers against UPV. We find that Nnat deficiency in isogenic mice triggers the emergence of a bi-stable polyphenism, where littermates emerge into adulthood either 'normal' or 'overgrown'. Mechanistically, this is mediated by an insulin-dependent overgrowth that arises from histone deacetylase (HDAC)-dependent ß-cell hyperproliferation. A multi-dimensional analysis of monozygotic twin discordance reveals the existence of two patterns of human UPV, one of which (Type B) phenocopies the NNAT-buffered polyphenism identified in mice. Specifically, Type-B monozygotic co-twins exhibit coordinated increases in fat and lean mass across the body; decreased NNAT expression; increased HDAC-responsive gene signatures; and clinical outcomes linked to insulinemia. Critically, the Type-B UPV signature stratifies both childhood and adult cohorts into four metabolic states, including two phenotypically and molecularly distinct types of obesity.


Asunto(s)
Proteínas de la Membrana , Proteínas del Tejido Nervioso , Adaptación Fisiológica , Adulto , Animales , Niño , Histona Desacetilasas , Humanos , Insulina , Proteínas de la Membrana/metabolismo , Ratones , Proteínas del Tejido Nervioso/genética , Obesidad/genética , Obesidad/metabolismo
8.
Lab Chip ; 19(7): 1217-1225, 2019 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-30801596

RESUMEN

We describe a Lab-on-a-Film disposable that detects multidrug-resistant tuberculosis (MDR-TB) from sputum extracts. The Lab-on-a-Film disposable consists of 203 gel elements that include DNA sequences (probes) for 37 mutations, deletions, or insertion elements across 5 genes (including an internal control). These gel elements are printed on a flexible film, which costs approximately 500 times less than microarray glass. The film with printed gel elements is then laminated to additional rollable materials (films) to form a microfluidic flow cell. We combined multiplex amplification and hybridization steps in a single microfluidic chamber, without buffer exchanges or other manipulations up to and throughout hybridization. This flow cell also incorporates post hybridization wash steps while retaining an entirely closed-amplicon system, thus minimizing the potential for sample or amplicon cross-contamination. We report analytical sensitivity of 32 cfu mL-1 across all MDR-TB markers and detection of MDR-TB positive clinical specimens using an automated TruTip workstation for extraction and the Lab-on-a-Film disposable for amplification and detection of the extracts.


Asunto(s)
Equipos Desechables , Resistencia a Múltiples Medicamentos/genética , Técnicas de Genotipaje/instrumentación , Mycobacterium tuberculosis/efectos de los fármacos , Mycobacterium tuberculosis/genética , Esputo/microbiología , Humanos
9.
J Microbiol Methods ; 148: 174-180, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29678500

RESUMEN

Systems that automate extraction of nucleic acid from cells or viruses in complex clinical matrices have tremendous value even in the absence of an integrated downstream detector. We describe our bench-top automated workstation that integrates our previously-reported extraction method - TruTip - with our newly-developed mechanical lysis method. This is the first report of this method for homogenizing viscous and heterogeneous samples and lysing difficult-to-disrupt cells using "MagVor": a rotating magnet that rotates a miniature stir disk amidst glass beads confined inside of a disposable tube. Using this system, we demonstrate automated nucleic acid extraction from methicillin-resistant Staphylococcus aureus (MRSA) in nasopharyngeal aspirate (NPA), influenza A in nasopharyngeal swabs (NPS), human genomic DNA from whole blood, and Mycobacterium tuberculosis in NPA. The automated workstation yields nucleic acid with comparable extraction efficiency to manual protocols, which include commercially-available Qiagen spin column kits, across each of these sample types. This work expands the scope of applications beyond previous reports of TruTip to include difficult-to-disrupt cell types and automates the process, including a method for removal of organics, inside a compact bench-top workstation.


Asunto(s)
Automatización de Laboratorios/instrumentación , Automatización de Laboratorios/métodos , Técnicas de Diagnóstico Molecular/instrumentación , Técnicas de Diagnóstico Molecular/métodos , Ácidos Nucleicos/aislamiento & purificación , Manejo de Especímenes/instrumentación , Manejo de Especímenes/métodos , Células Sanguíneas/química , Mezclas Complejas/aislamiento & purificación , Humanos , Virus de la Influenza A/química , Staphylococcus aureus Resistente a Meticilina/química , Mycobacterium tuberculosis/química
10.
PLoS One ; 13(7): e0199869, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29975759

RESUMEN

Automated nucleic acid extraction from primary (raw) sputum continues to be a significant technical challenge for molecular diagnostics. In this work, we developed a prototype open-architecture, automated nucleic acid workstation that includes a mechanical homogenization and lysis function integrated with heating and TruTip purification; optimized an extraction protocol for raw sputum; and evaluated system performance on primary clinical specimens. Eight samples could be processed within 70 min. The system efficiently homogenized primary sputa and doubled nucleic acid recovery relative to an automated protocol that did not incorporate sample homogenization. Nucleic acid recovery was at least five times higher from raw sputum as compared to that of matched sediments regardless of smear or culture grade, and the automated workstation reproducibly recovered PCR-detectable DNA to at least 80 CFU mL-1 raw sputum. M. tuberculosis DNA was recovered and detected from 122/123 (99.2%) and 124/124 (100%) primary sputum and sediment extracts, respectively. There was no detectable cross-contamination across 53 automated system runs and amplification or fluorescent inhibitors (if present) were not detectable. The open fluidic architecture of the prototype automated workstation yields purified sputum DNA that can be used for any molecular diagnostic test. The ability to transfer TruTip protocols between personalized, on-demand pipetting tools and the fully automated workstation also affords public health agencies an opportunity to standardize sputum nucleic acid sample preparation procedures, reagents, and quality control across multiple levels of the health care system.


Asunto(s)
ADN Bacteriano/genética , ADN Bacteriano/aislamiento & purificación , Mycobacterium tuberculosis/genética , Manejo de Especímenes/métodos , Esputo/microbiología , Tuberculosis/diagnóstico , Tuberculosis/microbiología , Automatización de Laboratorios , Humanos , Mycobacterium tuberculosis/aislamiento & purificación , Técnicas de Amplificación de Ácido Nucleico
11.
Stat Appl Genet Mol Biol ; 4: Article19, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16646836

RESUMEN

Epidemiologic and forensic investigations often require assays to detect subtle genetic differences between closely related microorganisms. Typically, gel electrophoresis is used to compare randomly amplified DNA fragments between microbial samples, where the patterns of DNA fragment sizes are viewed as genotype 'fingerprints'. The limited genomic sample captured on a gel, however, is not always sufficient to discriminate closely related strains. This paper examines the application of microarray technology to DNA fingerprinting as a high-resolution alternative to gel-based methods. The so-called universal microarray, which uses short oligonucleotide probes that do not target specific genes or species, is intended to be applicable to all microorganisms because it does not require prior knowledge of genomic sequence. In principle, closely related strains can be distinguished if enough independent oligonucleotide probes are used on the microarray, i.e., if the genome is sufficiently sampled. In practice, we confront noisy data, imperfectly matched hybridizations, and a high-dimensional inference problem. We describe the statistical problems of microarray fingerprinting, outline similarities with and differences from more conventional microarray applications, and illustrate a statistical measurement error model to fingerprint 10 closely related strains from three Bacillus species, and 3 strains from non-Bacillus species.

12.
Nucleic Acids Res ; 32(5): 1848-56, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15037662

RESUMEN

We report on a genome-independent microbial fingerprinting method using nucleic acid microarrays for microbial forensics and epidemiology applications and demonstrate that the microarray method provides high resolution differentiation between closely related microorganisms, using Salmonella enterica strains as the test case. In replicate trials we used a simple 192 probe nonamer array to construct a fingerprint library of 25 closely related Salmonella isolates. Controlling false discovery rate for multiple testing at alpha = 0.05, at least 295 of 300 pairs of S.enterica isolate fingerprints were found to be statistically distinct using a modified Hotelling T2 test. Although most pairs of Salmonella fingerprints are found to be distinct, forensic applications will also require a protocol for library construction and reliable microbial classification against a fingerprint library. We outline additional steps required to produce such a protocol.


Asunto(s)
Dermatoglifia del ADN/métodos , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Salmonella enterica/aislamiento & purificación , Teorema de Bayes , Interpretación Estadística de Datos , Humanos , Salmonella enterica/clasificación , Salmonella enterica/genética
13.
BMC Oral Health ; 6 Suppl 1: S10, 2006 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-16934111

RESUMEN

The human oral cavity contains a complex microbial community that, until recently, has not been well characterized. Studies using molecular tools have begun to enumerate and quantify the species residing in various niches of the oral cavity; yet, virtually every study has revealed additional new species, and little is known about the structural dynamics of the oral microbial community or how it changes with disease. Current estimates of bacterial diversity in the oral cavity range up to 700 species, although in any single individual this number is much lower. Oral microbes are responsible for common chronic diseases and are suggested to be sentinels of systemic human diseases. Microarrays are now being used to study oral microbiota in a systematic and robust manner. Although this technology is still relatively young, improvements have been made in all aspects of the technology, including advances that provide better discrimination between perfect-match hybridizations from non-specific (and closely-related) hybridizations. This review addresses a core technology using gel-based microarrays and the initial integration of this technology into a single device needed for system-wide studies of complex microbial community structure and for the development of oral diagnostic devices.

14.
Biotechniques ; 38(4): 591-600, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15884677

RESUMEN

With the rapid pace of nucleic acid microarray technology development and a renewed national emphasis on detecting and characterizing microorganisms in environmental samples, there is a rush to operationalize existing microarray technologies and apply them to uncharacterized environmental backgrounds. The purpose of this article is to pause and ask a basic question: what do microarray data actually mean in the face of uncharacterized sample backgrounds? In attempting to answer this question, we draw a clear distinction between hypothesis-driven fundamental science and operational uses of microarray technology; assess microarray technology assumptions in the face of uncharacterized environments; offer an environmental microbiologist's perspective on technology needs and requirements for quantitatively analyzing microbial communities; and hopefully stimulate a scientific and technical dialogue around the concept of analytical environmental microbiology and future technology development.


Asunto(s)
ADN Bacteriano/análisis , Microbiología Ambiental , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Bacterias/genética , Hibridación de Ácido Nucleico , Análisis de Secuencia por Matrices de Oligonucleótidos/tendencias , Sondas de Oligonucleótidos , Sensibilidad y Especificidad
15.
Biotechniques ; 39(1): 99-107, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16060374

RESUMEN

Protein profiling and characterization of protein interactions in biological samples ultimately require indicator-free methods of signal detection, which likewise offer an opportunity to distinguish specific interactions from nonspecific protein binding. Here we describe a new 3-dimensional protein microchip for detecting biomolecular interactions with matrix-assisted laser desorption-ionization mass spectrometry (MALDI-MS); the microchip comprises a high-density array of methacrylate polymer elements containing immobilized proteins as capture molecules and directly interfaces with a commercially available mass spectrometer. We demonstrated the performance of the chip in three types of experiments by detecting antibody-antigen interactions, enzymatic activity, and enzyme-inhibitor interactions. MALDI-MS biochip-based tumor necrosisfactor alpha (TNF-alpha) immunoassays demonstrated the feasibility of detecting antigens in complex biological samples by identifying molecular masses of bound proteins even at high nonspecific protein binding. By detecting model interactions of trypsin with trypsin inhibitors, we showed that the protein binding capacity of methacrylate polymer elements and the sensitivity of MALDI-MS detection of proteins bound to these elements surpassed that of other 2- and 3-dimensional substrates tested Immobilized trypsin retained functional (enzymatic) activity within the protein microchip and the specificity of macromolecular interactions even in complex biological samples. We believe that the underlying technology should therefore be extensible to whole-proteome protein expression profiling and interaction mapping.


Asunto(s)
Inmunoensayo/instrumentación , Análisis por Matrices de Proteínas/instrumentación , Mapeo de Interacción de Proteínas/instrumentación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Inmunoensayo/métodos , Análisis por Matrices de Proteínas/métodos , Mapeo de Interacción de Proteínas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
16.
J Microbiol Methods ; 53(2): 185-97, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12654490

RESUMEN

Currently, there is no single method to collect, process, and analyze a water sample for all pathogenic microorganisms of interest. Some of the difficulties in developing a universal method include the physical differences between the major pathogen groups (viruses, bacteria, protozoa), efficiently concentrating large volume water samples to detect low target concentrations of certain pathogen groups, removing co-concentrated inhibitors from the sample, and standardizing a culture-independent endpoint detection method. Integrating the disparate technologies into a single, universal, simple method and detection system would represent a significant advance in public health and microbiological water quality analysis. Recent advances in sample collection, on-line sample processing and purification, and DNA microarray technologies may form the basis of a universal method to detect known and emerging waterborne pathogens. This review discusses some of the challenges in developing a universal pathogen detection method, current technology that may be employed to overcome these challenges, and the remaining needs for developing an integrated pathogen detection and monitoring system for source or finished water.


Asunto(s)
Monitoreo del Ambiente/métodos , Microbiología del Agua , Agua/parasitología , Animales , Bacterias/genética , Bacterias/aislamiento & purificación , Control de Enfermedades Transmisibles , Eucariontes/genética , Eucariontes/aislamiento & purificación , Helmintos/genética , Helmintos/aislamiento & purificación , Humanos , Infecciones/etiología , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Virus/genética , Virus/aislamiento & purificación , Abastecimiento de Agua/normas
17.
J Vis Exp ; (86)2014 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-24796567

RESUMEN

Simplifying microarray workflow is a necessary first step for creating MDR-TB microarray-based diagnostics that can be routinely used in lower-resource environments. An amplification microarray combines asymmetric PCR amplification, target size selection, target labeling, and microarray hybridization within a single solution and into a single microfluidic chamber. A batch processing method is demonstrated with a 9-plex asymmetric master mix and low-density gel element microarray for genotyping multi-drug resistant Mycobacterium tuberculosis (MDR-TB). The protocol described here can be completed in 6 hr and provide correct genotyping with at least 1,000 cell equivalents of genomic DNA. Incorporating on-chip wash steps is feasible, which will result in an entirely closed amplicon method and system. The extent of multiplexing with an amplification microarray is ultimately constrained by the number of primer pairs that can be combined into a single master mix and still achieve desired sensitivity and specificity performance metrics, rather than the number of probes that are immobilized on the array. Likewise, the total analysis time can be shortened or lengthened depending on the specific intended use, research question, and desired limits of detection. Nevertheless, the general approach significantly streamlines microarray workflow for the end user by reducing the number of manually intensive and time-consuming processing steps, and provides a simplified biochemical and microfluidic path for translating microarray-based diagnostics into routine clinical practice.


Asunto(s)
Mycobacterium tuberculosis/efectos de los fármacos , Mycobacterium tuberculosis/genética , Reacción en Cadena de la Polimerasa/métodos , Farmacorresistencia Bacteriana Múltiple , Tuberculosis/microbiología
19.
J Virol Methods ; 208: 152-9, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25066276

RESUMEN

The objectives of this study were to develop a user-friendly, gel element microarray test for influenza virus detection, subtyping, and neuraminidase inhibitor resistance detection, assess the performance characteristics of the assay, and perform a clinical evaluation on retrospective nasopharyngeal swab specimens. A streamlined microarray workflow enabled a single user to run up to 24 tests in an 8h shift. The most sensitive components of the test were the primers and probes targeting the A/H1 pdm09 HA gene with an analytical limit of detection (LoD) <100 gene copies (gc) per reaction. LoDs for all targets in nasopharyngeal swab samples were ≤1000 gc, with the exception of one target in the seasonal A/H1N1 subtype. Seasonal H275Y variants were detectable in a mixed population when present at >5% with wild type virus, while the 2009 pandemic H1N1 H275Y variant was detectable at ≤1% in a mixture with pandemic wild type virus. Influenza typing and subtyping results concurred with those obtained with real-time RT-PCR assays on more than 97% of the samples tested. The results demonstrate that a large panel of single-plex, real-time RT-PCR tests can be translated to an easy-to-use, sensitive, and specific microarray test for potential diagnostic use.


Asunto(s)
Farmacorresistencia Viral , Subtipo H1N1 del Virus de la Influenza A/clasificación , Subtipo H1N1 del Virus de la Influenza A/aislamiento & purificación , Análisis por Micromatrices/métodos , Técnicas de Diagnóstico Molecular/métodos , Neuraminidasa/genética , Proteínas Virales/genética , Antivirales/farmacología , Humanos , Subtipo H1N1 del Virus de la Influenza A/efectos de los fármacos , Subtipo H1N1 del Virus de la Influenza A/genética , Laboratorios , Tipificación Molecular/métodos , Proteínas Mutantes/genética , Nasofaringe/virología , Oseltamivir/farmacología , Estudios Retrospectivos , Sensibilidad y Especificidad , Factores de Tiempo , Recursos Humanos
20.
J Clin Virol ; 58(1): 138-43, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23880159

RESUMEN

BACKGROUND: Rapid, simple and efficient influenza RNA purification from clinical samples is essential for sensitive molecular detection of influenza infection. Automation of the TruTip extraction method can increase sample throughput while maintaining performance. OBJECTIVES: To automate TruTip influenza RNA extraction using an Eppendorf epMotion robotic liquid handler, and to compare its performance to the bioMerieux easyMAG and Qiagen QIAcube instruments. STUDY DESIGN: Extraction efficacy and reproducibility of the automated TruTip/epMotion protocol was assessed from influenza-negative respiratory samples spiked with influenza A and B viruses. Clinical extraction performance from 170 influenza A and B-positive respiratory swabs was also evaluated and compared using influenza A and B real-time RT-PCR assays. RESULTS: TruTip/epMotion extraction efficacy was 100% in influenza virus-spiked samples with at least 745 influenza A and 370 influenza B input gene copies per extraction, and exhibited high reproducibility over four log10 concentrations of virus (<1% CV). RNA yields between the three automated methods differed by less than 0.5 log10 gene copies. 99% of clinical specimens that were PCR-positive after easyMAG or QIAcube extraction were also positive following TruTip extraction. Overall Ct value differences obtained between TruTip/epMotion and easyMAG/QIAcube clinical extracts ranged from 1.24 to 1.91. Pairwise comparisons of Ct values showed a high correlation of the TruTip/epMotion protocol to the other methods (R2>0.90). CONCLUSION: The automated TruTip/epMotion protocol is a simple and rapid extraction method that reproducibly purifies influenza RNA from respiratory swabs, with comparable efficacy and efficiency to both the easyMAG and QIAcube instruments.


Asunto(s)
Automatización de Laboratorios/métodos , Gripe Humana/diagnóstico , Orthomyxoviridae/genética , ARN Viral/aislamiento & purificación , Sistema Respiratorio/virología , Manejo de Especímenes/métodos , Humanos , Orthomyxoviridae/aislamiento & purificación , ARN Viral/genética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA