Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 177
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Annu Rev Biochem ; 88: 35-58, 2019 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-30601681

RESUMEN

X-ray free-electron lasers provide femtosecond-duration pulses of hard X-rays with a peak brightness approximately one billion times greater than is available at synchrotron radiation facilities. One motivation for the development of such X-ray sources was the proposal to obtain structures of macromolecules, macromolecular complexes, and virus particles, without the need for crystallization, through diffraction measurements of single noncrystalline objects. Initial explorations of this idea and of outrunning radiation damage with femtosecond pulses led to the development of serial crystallography and the ability to obtain high-resolution structures of small crystals without the need for cryogenic cooling. This technique allows the understanding of conformational dynamics and enzymatics and the resolution of intermediate states in reactions over timescales of 100 fs to minutes. The promise of more photons per atom recorded in a diffraction pattern than electrons per atom contributing to an electron micrograph may enable diffraction measurements of single molecules, although challenges remain.


Asunto(s)
Electrones , Sustancias Macromoleculares/ultraestructura , Fotones , Virión/ultraestructura , Difracción de Rayos X/métodos , Cristalización/instrumentación , Cristalización/métodos , Cristalografía por Rayos X/historia , Cristalografía por Rayos X/instrumentación , Cristalografía por Rayos X/métodos , Historia del Siglo XX , Historia del Siglo XXI , Rayos Láser/historia , Sincrotrones/instrumentación , Difracción de Rayos X/historia , Difracción de Rayos X/instrumentación , Rayos X
2.
Cell ; 170(3): 457-469.e13, 2017 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-28753425

RESUMEN

G protein-coupled receptors (GPCRs) mediate diverse signaling in part through interaction with arrestins, whose binding promotes receptor internalization and signaling through G protein-independent pathways. High-affinity arrestin binding requires receptor phosphorylation, often at the receptor's C-terminal tail. Here, we report an X-ray free electron laser (XFEL) crystal structure of the rhodopsin-arrestin complex, in which the phosphorylated C terminus of rhodopsin forms an extended intermolecular ß sheet with the N-terminal ß strands of arrestin. Phosphorylation was detected at rhodopsin C-terminal tail residues T336 and S338. These two phospho-residues, together with E341, form an extensive network of electrostatic interactions with three positively charged pockets in arrestin in a mode that resembles binding of the phosphorylated vasopressin-2 receptor tail to ß-arrestin-1. Based on these observations, we derived and validated a set of phosphorylation codes that serve as a common mechanism for phosphorylation-dependent recruitment of arrestins by GPCRs.


Asunto(s)
Arrestinas/química , Rodopsina/química , Secuencia de Aminoácidos , Animales , Arrestinas/metabolismo , Cromatografía Liquida , Humanos , Ratones , Modelos Moleculares , Fosforilación , Ratas , Rodopsina/metabolismo , Alineación de Secuencia , Espectrometría de Masas en Tándem , Rayos X
3.
Proc Natl Acad Sci U S A ; 120(49): e2203241120, 2023 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-38015839

RESUMEN

The Lysinibacillus sphaericus proteins Tpp49Aa1 and Cry48Aa1 can together act as a toxin toward the mosquito Culex quinquefasciatus and have potential use in biocontrol. Given that proteins with sequence homology to the individual proteins can have activity alone against other insect species, the structure of Tpp49Aa1 was solved in order to understand this protein more fully and inform the design of improved biopesticides. Tpp49Aa1 is naturally expressed as a crystalline inclusion within the host bacterium, and MHz serial femtosecond crystallography using the novel nanofocus option at an X-ray free electron laser allowed rapid and high-quality data collection to determine the structure of Tpp49Aa1 at 1.62 Å resolution. This revealed the packing of Tpp49Aa1 within these natural nanocrystals as a homodimer with a large intermolecular interface. Complementary experiments conducted at varied pH also enabled investigation of the early structural events leading up to the dissolution of natural Tpp49Aa1 crystals-a crucial step in its mechanism of action. To better understand the cooperation between the two proteins, assays were performed on a range of different mosquito cell lines using both individual proteins and mixtures of the two. Finally, bioassays demonstrated Tpp49Aa1/Cry48Aa1 susceptibility of Anopheles stephensi, Aedes albopictus, and Culex tarsalis larvae-substantially increasing the potential use of this binary toxin in mosquito control.


Asunto(s)
Bacillaceae , Bacillus , Culex , Plaguicidas , Animales , Bacillaceae/química , Bacillaceae/metabolismo , Control de Mosquitos , Larva/metabolismo
4.
Opt Express ; 32(9): 16004-16015, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38859238

RESUMEN

Multilayer Laue lenses are volume diffractive optical elements for hard X-rays with the potential to focus beams to sizes as small as 1 nm. This ability is limited by the precision of the manufacturing process, whereby systematic errors that arise during fabrication contribute to wavefront aberrations even after calibration of the deposition process based on wavefront metrology. Such aberrations can be compensated by using a phase plate. However, current high numerical aperture lenses for nanometer resolution exhibit errors that exceed those that can be corrected by a single phase plate. To address this, we accumulate a large wavefront correction by propagation through a linear array of 3D-printed phase correcting elements. With such a compound refractive corrector, we report on a point spread function with a full-width at half maximum area of 2.9 × 2.8 nm2 at a photon energy of 17.5 keV.

5.
Nat Methods ; 17(1): 73-78, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31740816

RESUMEN

The European XFEL (EuXFEL) is a 3.4-km long X-ray source, which produces femtosecond, ultrabrilliant and spatially coherent X-ray pulses at megahertz (MHz) repetition rates. This X-ray source has been designed to enable the observation of ultrafast processes with near-atomic spatial resolution. Time-resolved crystallographic investigations on biological macromolecules belong to an important class of experiments that explore fundamental and functional structural displacements in these molecules. Due to the unusual MHz X-ray pulse structure at the EuXFEL, these experiments are challenging. Here, we demonstrate how a biological reaction can be followed on ultrafast timescales at the EuXFEL. We investigate the picosecond time range in the photocycle of photoactive yellow protein (PYP) with MHz X-ray pulse rates. We show that difference electron density maps of excellent quality can be obtained. The results connect the previously explored femtosecond PYP dynamics to timescales accessible at synchrotrons. This opens the door to a wide range of time-resolved studies at the EuXFEL.


Asunto(s)
Proteínas Bacterianas/química , Cristalografía por Rayos X/instrumentación , Cristalografía por Rayos X/métodos , Fotorreceptores Microbianos/química , Conformación Proteica , Luz , Modelos Moleculares , Factores de Tiempo
6.
J Synchrotron Radiat ; 30(Pt 1): 11-23, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36601922

RESUMEN

With the development of X-ray free-electron lasers (XFELs), producing pulses of femtosecond durations comparable with the coherence times of X-ray fluorescence, it has become possible to observe intensity-intensity correlations due to the interference of emission from independent atoms. This has been used to compare durations of X-ray pulses and to measure the size of a focusedX-ray beam, for example. Here it is shown that it is also possible to observe the interference of fluorescence photons through the measurement of the speckle contrast of angle-resolved fluorescence patterns. Speckle contrast is often used as a measure of the degree of coherence of the incident beam or the fluctuations of the illuminated sample as determined from X-ray diffraction patterns formed by elastic scattering, rather than from fluorescence patterns as addressed here. Commonly used approaches to estimate speckle contrast were found to suffer when applied to XFEL-generated fluorescence patterns due to low photon counts and a significant variation of the excitation pulse energy from shot to shot. A new method to reliably estimate speckle contrast under such conditions, using a weighting scheme, is introduced. The method is demonstrated by comparing the speckle contrast of fluorescence observed with pulses of 3 fs to 15 fs duration.

7.
J Synchrotron Radiat ; 30(Pt 6): 1030-1037, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37729072

RESUMEN

The high pulse intensity and repetition rate of the European X-ray Free-Electron Laser (EuXFEL) provide superior temporal resolution compared with other X-ray sources. In combination with MHz X-ray microscopy techniques, it offers a unique opportunity to achieve superior contrast and spatial resolution in applications demanding high temporal resolution. In both live visualization and offline data analysis for microscopy experiments, baseline normalization is essential for further processing steps such as phase retrieval and modal decomposition. In addition, access to normalized projections during data acquisition can play an important role in decision-making and improve the quality of the data. However, the stochastic nature of X-ray free-electron laser sources hinders the use of standard flat-field normalization methods during MHz X-ray microscopy experiments. Here, an online (i.e. near real-time) dynamic flat-field correction method based on principal component analysis of dynamically evolving flat-field images is presented. The method is used for the normalization of individual X-ray projections and has been implemented as a near real-time analysis tool at the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument of EuXFEL.

8.
Opt Express ; 31(15): 25082-25092, 2023 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-37475321

RESUMEN

Second-order intensity correlations from incoherent emitters can reveal the Fourier transform modulus of their spatial distribution, but retrieving the phase to enable completely general Fourier inversion to real space remains challenging. Phase retrieval via the third-order intensity correlations has relied on special emitter configurations which simplified an unaddressed sign problem in the computation. Without a complete treatment of this sign problem, the general case of retrieving the Fourier phase from a truly arbitrary configuration of emitters is not possible. In this paper, a general method for ab initio phase retrieval via the intensity triple correlations is described. Simulations demonstrate accurate phase retrieval for clusters of incoherent emitters which could be applied to imaging stars or fluorescent atoms and molecules. With this work, it is now finally tractable to perform Fourier inversion directly and reconstruct images of arbitrary arrays of independent emitters via far-field intensity correlations alone.

9.
Opt Express ; 31(11): 18399-18406, 2023 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-37381551

RESUMEN

The characterisation of fast phenomena at the microscopic scale is required for the understanding of catastrophic responses of materials to loads and shocks, the processing of materials by optical or mechanical means, the processes involved in many key technologies such as additive manufacturing and microfluidics, and the mixing of fuels in combustion. Such processes are usually stochastic in nature and occur within the opaque interior volumes of materials or samples, with complex dynamics that evolve in all three dimensions at speeds exceeding many meters per second. There is therefore a need for the ability to record three-dimensional X-ray movies of irreversible processes with resolutions of micrometers and frame rates of microseconds. Here we demonstrate a method to achieve this by recording a stereo phase-contrast image pair in a single exposure. The two images are combined computationally to reconstruct a 3D model of the object. The method is extendable to more than two simultaneous views. When combined with megahertz pulse trains of X-ray free-electron lasers (XFELs) it will be possible to create movies able to resolve 3D trajectories with velocities of kilometers per second.

10.
Phys Rev Lett ; 130(17): 173201, 2023 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-37172237

RESUMEN

We demonstrate that x-ray fluorescence emission, which cannot maintain a stationary interference pattern, can be used to obtain images of structures by recording photon-photon correlations in the manner of the stellar intensity interferometry of Hanbury Brown and Twiss. This is achieved utilizing femtosecond-duration pulses of a hard x-ray free-electron laser to generate the emission in exposures comparable to the coherence time of the fluorescence. Iterative phasing of the photon correlation map generated a model-free real-space image of the structure of the emitters. Since fluorescence can dominate coherent scattering, this may enable imaging uncrystallised macromolecules.

11.
Opt Express ; 30(14): 25450-25473, 2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-36237075

RESUMEN

In recent years, X-ray speckle tracking techniques have emerged as viable tools for wavefront metrology and sample imaging applications, and have been actively developed for use at synchrotron light sources. Speckle techniques can recover an image free of aberrations and can be used to measure wavefronts with a high angular sensitivity. Since they are compatible with low-coherence sources they can be also used with laboratory X-ray sources. A new implementation of the ptychographic X-ray speckle tracking method, suitable for the metrology of highly divergent wavefields, such as those created by multilayer Laue lenses, is presented here. This new program incorporates machine learning techniques such as Huber and non-parametric regression and enables robust and quick wavefield measurements and data evaluation even for low brilliance X-ray beams, and the imaging of low-contrast samples. To realize this, a software suite was written in Python 3, with a C back-end capable of concurrent calculations for high performance. It is accessible as a Python module and is available as source code under Version 3 or later of the GNU General Public License.

12.
Nature ; 530(7589): 202-6, 2016 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-26863980

RESUMEN

The three-dimensional structures of macromolecules and their complexes are mainly elucidated by X-ray protein crystallography. A major limitation of this method is access to high-quality crystals, which is necessary to ensure X-ray diffraction extends to sufficiently large scattering angles and hence yields information of sufficiently high resolution with which to solve the crystal structure. The observation that crystals with reduced unit-cell volumes and tighter macromolecular packing often produce higher-resolution Bragg peaks suggests that crystallographic resolution for some macromolecules may be limited not by their heterogeneity, but by a deviation of strict positional ordering of the crystalline lattice. Such displacements of molecules from the ideal lattice give rise to a continuous diffraction pattern that is equal to the incoherent sum of diffraction from rigid individual molecular complexes aligned along several discrete crystallographic orientations and that, consequently, contains more information than Bragg peaks alone. Although such continuous diffraction patterns have long been observed--and are of interest as a source of information about the dynamics of proteins--they have not been used for structure determination. Here we show for crystals of the integral membrane protein complex photosystem II that lattice disorder increases the information content and the resolution of the diffraction pattern well beyond the 4.5-ångström limit of measurable Bragg peaks, which allows us to phase the pattern directly. Using the molecular envelope conventionally determined at 4.5 ångströms as a constraint, we obtain a static image of the photosystem II dimer at a resolution of 3.5 ångströms. This result shows that continuous diffraction can be used to overcome what have long been supposed to be the resolution limits of macromolecular crystallography, using a method that exploits commonly encountered imperfect crystals and enables model-free phasing.


Asunto(s)
Cristalografía por Rayos X/métodos , Complejo de Proteína del Fotosistema II/química , Cristalización , Modelos Moleculares
13.
Opt Express ; 29(3): 3097-3113, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-33770916

RESUMEN

Multilayer Laue lenses are diffractive optics for hard X-rays. To achieve high numerical aperture and resolution, diffracting structures of nanometer periods are required in such lenses, and a thickness (in the direction of propagation) of several micrometers is needed for high diffracting efficiency. Such structures must be oriented to satisfy Bragg's law, which can only be achieved consistently over the entire lens if the layers vary in their tilt relative to the incident beam. The correct tilt, for a particular wavelength, can be achieved with a very simple technique of using a straight-edge mask to give the necessary gradient of the layers. An analysis of the properties of lenses cut from such a shaded profile is presented and it is shown how to design, prepare, and characterize matched pairs of lenses that operate at a particular wavelength and focal length. It is also shown how to manufacture lenses with ideal curved layers for optimal efficiency.

14.
Opt Express ; 29(21): 34394-34410, 2021 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-34809231

RESUMEN

High-speed liquid micro-jets are used to rapidly and repeatedly deliver protein microcrystals to focused and pulsed X-ray beams in the method of serial femtosecond crystallography. However, the current continuous flow of crystals is mismatched to the arrival of X-ray pulses, wasting vast amounts of an often rare and precious sample. Here, we introduce a method to address this problem by periodically trapping and releasing crystals in the liquid flow, creating locally concentrated crystal bunches, using an optical trap integrated in the microfluidic supply line. We experimentally demonstrate a 30-fold increase of particle concentration into 10 Hz bunches of 6.4 µm diameter polystyrene particles. Furthermore, using particle trajectory simulations, a comprehensive description of the optical bunching process and parameter space is presented. Adding this compact optofluidics device to existing injection systems would thereby dramatically reduce sample consumption and extend the application of serial crystallography to a greater range of protein crystal systems that cannot be produced in high abundance. Our approach is suitable for other microfluidic systems that require synchronous measurements of flowing objects.

15.
Proc Natl Acad Sci U S A ; 115(22): 5652-5657, 2018 05 29.
Artículo en Inglés | MEDLINE | ID: mdl-29760050

RESUMEN

The bright ultrafast pulses of X-ray Free-Electron Lasers allow investigation into the structure of matter under extreme conditions. We have used single pulses to ionize and probe water as it undergoes a phase transition from liquid to plasma. We report changes in the structure of liquid water on a femtosecond time scale when irradiated by single 6.86 keV X-ray pulses of more than 106 J/cm2 These observations are supported by simulations based on molecular dynamics and plasma dynamics of a water system that is rapidly ionized and driven out of equilibrium. This exotic ionic and disordered state with the density of a liquid is suggested to be structurally different from a neutral thermally disordered state.


Asunto(s)
Electrones , Calor , Rayos Láser , Agua/química , Cristalografía , Simulación de Dinámica Molecular , Factores de Tiempo
16.
J Chem Phys ; 152(8): 084307, 2020 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-32113333

RESUMEN

We report experimental results on the diffractive imaging of three-dimensionally aligned 2,5-diiodothiophene molecules. The molecules were aligned by chirped near-infrared laser pulses, and their structure was probed at a photon energy of 9.5 keV (λ ≈ 130 pm) provided by the Linac Coherent Light Source. Diffracted photons were recorded on the Cornell-SLAC pixel array detector, and a two-dimensional diffraction pattern of the equilibrium structure of 2,5-diiodothiophene was recorded. The retrieved distance between the two iodine atoms agrees with the quantum-chemically calculated molecular structure to be within 5%. The experimental approach allows for the imaging of intrinsic molecular dynamics in the molecular frame, albeit this requires more experimental data, which should be readily available at upcoming high-repetition-rate facilities.

17.
Proc Natl Acad Sci U S A ; 114(9): 2247-2252, 2017 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-28202732

RESUMEN

To understand how molecules function in biological systems, new methods are required to obtain atomic resolution structures from biological material under physiological conditions. Intense femtosecond-duration pulses from X-ray free-electron lasers (XFELs) can outrun most damage processes, vastly increasing the tolerable dose before the specimen is destroyed. This in turn allows structure determination from crystals much smaller and more radiation sensitive than previously considered possible, allowing data collection from room temperature structures and avoiding structural changes due to cooling. Regardless, high-resolution structures obtained from XFEL data mostly use crystals far larger than 1 µm3 in volume, whereas the X-ray beam is often attenuated to protect the detector from damage caused by intense Bragg spots. Here, we describe the 2 Å resolution structure of native nanocrystalline granulovirus occlusion bodies (OBs) that are less than 0.016 µm3 in volume using the full power of the Linac Coherent Light Source (LCLS) and a dose up to 1.3 GGy per crystal. The crystalline shell of granulovirus OBs consists, on average, of about 9,000 unit cells, representing the smallest protein crystals to yield a high-resolution structure by X-ray crystallography to date. The XFEL structure shows little to no evidence of radiation damage and is more complete than a model determined using synchrotron data from recombinantly produced, much larger, cryocooled granulovirus granulin microcrystals. Our measurements suggest that it should be possible, under ideal experimental conditions, to obtain data from protein crystals with only 100 unit cells in volume using currently available XFELs and suggest that single-molecule imaging of individual biomolecules could almost be within reach.


Asunto(s)
Cristalografía/métodos , Electrones , Granulovirus/ultraestructura , Péptidos y Proteínas de Señalización Intercelular/química , Rayos Láser , Cristalografía/instrumentación , Granulovirus/química , Modelos Moleculares , Progranulinas , Estructura Secundaria de Proteína , Sincrotrones
18.
J Synchrotron Radiat ; 26(Pt 4): 1115-1126, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31274435

RESUMEN

Here a direct comparison is made between various X-ray wavefront sensing methods with application to optics alignment and focus characterization at X-ray free-electron lasers (XFELs). Focus optimization at XFEL beamlines presents unique challenges due to high peak powers as well as beam pointing instability, meaning that techniques capable of single-shot measurement and that probe the wavefront at an out-of-focus location are desirable. The techniques chosen for the comparison include single-phase-grating Talbot interferometry (shearing interferometry), dual-grating Talbot interferometry (moiré deflectometry) and speckle tracking. All three methods were implemented during a single beam time at the Linac Coherent Light Source, at the X-ray Pump Probe beamline, in order to make a direct comparison. Each method was used to characterize the wavefront resulting from a stack of beryllium compound refractive lenses followed by a corrective phase plate. In addition, difference wavefront measurements with and without the phase plate agreed with its design to within λ/20, which enabled a direct quantitative comparison between methods. Finally, a path toward automated alignment at XFEL beamlines using a wavefront sensor to close the loop is presented.

19.
Opt Express ; 27(26): 37816-37833, 2019 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-31878556

RESUMEN

An outstanding question in X-ray single particle imaging experiments has been the feasibility of imaging sub 10-nm-sized biomolecules under realistic experimental conditions where very few photons are expected to be measured in a single snapshot and instrument background may be significant relative to particle scattering. While analyses of simulated data have shown that the determination of an average image should be feasible using Bayesian methods such as the EMC algorithm, this has yet to be demonstrated using experimental data containing realistic non-isotropic instrument background, sample variability and other experimental factors. In this work, we show that the orientation and phase retrieval steps work at photon counts diluted to the signal levels one expects from smaller molecules or with weaker pulses, using data from experimental measurements of 60-nm PR772 viruses. Even when the signal is reduced to a fraction as little as 1/256, the virus electron density determined using ab initio phasing is of almost the same quality as the high-signal data. However, we are still limited by the total number of patterns collected, which may soon be mitigated by the advent of high repetition-rate sources like the European XFEL and LCLS-II.

20.
Opt Express ; 27(5): 7120-7138, 2019 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-30876283

RESUMEN

X-ray microscopy at photon energies above 15 keV is very attractive for the investigation of atomic and nanoscale properties of technologically relevant structural and bio materials. This method is limited by the quality of X-ray optics. Multilayer Laue lenses (MLLs) have the potential to make a major impact in this field because, as compared to other X-ray optics, they become more efficient and effective with increasing photon energy. In this work, MLLs were utilized with hard X-rays at photon energies up to 34.5 keV. The design, fabrication, and performance of these lenses are presented, and their application in several imaging configurations is described. In particular, two "full field" modes of imaging were explored, which provide various contrast modalities that are useful for materials characterisation. These include point projection imaging (or Gabor holography) for phase contrast imaging and direct imaging with both bright-field and dark-field illumination. With high-efficiency MLLs, such modes offer rapid data collection as compared with scanning methods as well as a large field of views.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA