Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artif Organs ; 35(9): 867-74, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21726241

RESUMEN

The effects of the intra-aortic balloon pump (IABP) counterpulsation on the extent of myocardial infarction (MI), the no-reflow phenomenon (NRP), and coronary blood flow (CBF) during reperfusion in an ischemia-reperfusion experimental model have not been clarified. Eleven pigs underwent occlusion of the mid left anterior descending coronary artery for 1 h, followed by reperfusion for 2 h. CBF, distal to the occlusion site, was measured. In six experiments, IABP support began 10 min before, and continued throughout reperfusion (IABP Group). Five pigs without IABP support served as controls. At the end of each experiment, the myocardial area at risk (MAR) of infarction and the extent of MI and NRP were measured. Hemodynamic measurements at baseline and during coronary occlusion were similar in both groups. During reperfusion, systolic aortic blood pressure was significantly lower in the IABP Group than in controls. In the IABP Group, CBF reached a peak at 5 min of reperfusion, gradually decreased, but remained higher than at baseline, and significantly higher than in controls throughout the 2 h of reperfusion. In controls, CBF increased significantly above baseline immediately after the onset of reperfusion, then returned to baseline within 90 min. The extent of NRP (37 ± 25% vs. 68 ± 17%, P = 0.047) and MI (39 ± 23% vs. 67 ± 13%, P = 0.036), both expressed as percentage of MAR, was significantly less in the IABP group than in controls. After prolonged myocardial ischemia, IABP assistance started just 10 min before and throughout reperfusion increased CBF and limited infarct size and extent of NRP.


Asunto(s)
Circulación Coronaria/fisiología , Contrapulsador Intraaórtico/métodos , Reperfusión Miocárdica/métodos , Fenómeno de no Reflujo/fisiopatología , Animales , Corazón/fisiopatología , Hemodinámica , Daño por Reperfusión Miocárdica/fisiopatología , Daño por Reperfusión Miocárdica/terapia , Fenómeno de no Reflujo/terapia , Porcinos
2.
ASAIO J ; 51(1): 26-9, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15745130

RESUMEN

The aim of this study was to examine whether pulsatility by intraaortic balloon counterpulsation (IABP) is an important adjunct to the treatment of profound cardiogenic shock (CS) with a widely used, nonpulsatile centrifugal pump (CP). In each of 18 anesthetized, open chest pigs, the outflow cannula of the CP was inserted in the aortic arch through the right external carotid artery, and the inflow cannula of the CP was placed in the left atrium. A 40 cc IABP was subsequently placed in the descending aorta through the left external carotid artery. CS was induced by occlusion of coronary arteries and the infusion of propranolol and crystalloid fluid. Mean aortic pressure, pulse pressure, aortic end diastolic pressure, left ventricular end diastolic pressure, right atrial pressure, and heart rate were monitored. Cardiac output and left anterior descending artery flow were measured with a transit time ultrasound flowmeter. During profound CS, life sustaining hemodynamics were maintained only with the support of the assist devices. Hemodynamic support with the CP was associated with a nearly nonpulsatile flow and a pulse pressure of 7 +/- 4 mm Hg, which increased to 33 +/- 10 mm Hg (p = 0.000) after combining the CP with the IABP. Compared with the hemodynamic support offered by the CP alone, addition of the IABP increased mean aortic pressure from 40 +/- 15 to 50 +/- 16 mm Hg (p = 0.000), cardiac output from 810 +/- 194 to 1,200 +/- 234 ml/min (p = 0.003), and left anterior descending artery flow from 26 +/- 10 to 39 +/- 14 ml/min (p = 0.001). In profound CS, mechanical support provided by a continuous flow CP is enhanced by the added pulsatility of the IABP.


Asunto(s)
Contrapulsación , Corazón Auxiliar , Hemodinámica/fisiología , Contrapulsador Intraaórtico , Flujo Pulsátil/fisiología , Choque Cardiogénico/terapia , Animales , Aorta/fisiología , Presión Sanguínea , Cateterismo , Diástole , Modelos Animales de Enfermedad , Frecuencia Cardíaca , Modelos Cardiovasculares , Choque Cardiogénico/inducido químicamente , Sus scrofa
3.
Chest ; 125(4): 1492-9, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15078763

RESUMEN

STUDY OBJECTIVE: s: To examine the effects of low arterial BP (ABP) during reperfusion on the extent of myocardial infarction and on coronary blood flow (CBF) in an occlusion/reperfusion experimental model. DESIGN: Prospective, randomized animal study. SETTING: University hospital. PARTICIPANTS: Normal pigs that were anesthetized, intubated, and mechanically ventilated. INTERVENTIONS: Twenty-seven open-chest pigs underwent occlusion of the mid left anterior descending (LAD) coronary artery for 1 h followed by reperfusion for 2 h. During reperfusion, the animals were randomly assigned to either continuous infusion of nitroglycerin in therapeutic doses and fluid infusion at rates to maintain a mean ABP >or= 80 mm Hg (group 1, n = 13), or continuous nitroglycerin infusion at rates to maintain a mean ABP between 60 mm Hg and 75 mm Hg (group 2, n = 14). MEASUREMENTS AND RESULTS: The hemodynamics and the coronary ABP distal to the occlusion were recorded throughout the experiment. In addition, the LAD CBF and peak hyperemia CBF before occlusion and during reperfusion periods were measured by transit-time flowmetry. At the end of the experiment, the infarcted left ventricular myocardial size was measured. There were no significant hemodynamic differences, including the distal coronary arterial pressure, between the two groups before or during the LAD artery occlusion period. During reperfusion, mean ABP was 90 +/- 3 mm Hg in group 1 vs 69 +/- 3 mm Hg in group 2 (p < 0.001). In group 1, the infarcted myocardium represented 50.3 +/- 4.3% of the myocardium at risk, vs 69.4 +/- 7.2% in group 2 (p < 0.001). During reperfusion, CBF and peak hyperemia CBF were significantly higher in group 1 than in group 2. CONCLUSIONS: Low ABP during reperfusion increases the size of myocardial infarction and decreases CBF.


Asunto(s)
Circulación Coronaria/fisiología , Hipotensión Controlada , Infarto del Miocardio/patología , Reperfusión Miocárdica , Animales , Circulación Colateral , Estudios Prospectivos , Distribución Aleatoria , Porcinos
4.
Resuscitation ; 61(1): 83-9, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15081186

RESUMEN

UNLABELLED: Experimental studies have described an increase in ventricular fibrillation threshold (VFT) by intravenous amiodarone. The aim of this study was to examine the early time course of changes in VFT and defibrillation thresholds (DFT) after an intravenous bolus of amiodarone in an experimental pig model of transient myocardial ischemia. METHODS AND RESULTS: VFT and relative effective ventricular refractory period (ERP) were measured in 15 anaesthetized open-chest pigs after 3 min of regional coronary ischaemia before (time 0) and 2, 15, 30, 60, and 90 min after the intravenous injection of normal saline (group A, n = 5) or amiodarone, 5 mg/kg over 15 s (group B, n = 10). DFT was measured by increasing the strength of DC shocks until defibrillation was accomplished. Amiodarone caused an increase in VFT, starting at 2 min after the infusion (11.4 +/- 8.4 mA versus 9.2 +/- 4.6 mA, P = 0.03), became significant at 15 min (13.7 +/- 6.5 mA, P = 0.009), continued to rise at 30 min (34.2 +/- 28.7 mA, P = 0.03) and reached a plateau at 60 min (50.3 +/- 37.8 mA, P = 0.008). An increase was also observed in the ERP (204 +/- 25 ms at 2 min versus 197 +/- 26 ms at baseline, P = 0.074, 211 +/- 38 ms at 15 min, P = 0.084, 212 +/- 40 ms at 30 min, P = 0.037, 220 +/- 34 ms at 60 min, P = 0.002, and 227 +/- 32 ms at 90 min, P = 0.008). No change was observed in DFT after amiodarone administration. No significant change in VFT, ERP, or DFT occurred in the control group. CONCLUSION: In this porcine model, the intravenous administration of amiodarone increased VFT and ERP over 60 min after the injection, without effect on DFT.


Asunto(s)
Amiodarona/administración & dosificación , Antiarrítmicos/administración & dosificación , Cardioversión Eléctrica , Isquemia Miocárdica/complicaciones , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia , Animales , Presión Sanguínea , Umbral Diferencial , Inyecciones Intravenosas , Porcinos , Factores de Tiempo , Fibrilación Ventricular/fisiopatología , Función Ventricular Izquierda/efectos de los fármacos
5.
Int J Cardiol ; 138(3): 253-60, 2010 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-18805599

RESUMEN

BACKGROUND: Studies of the IABP have reported variable effects on coronary blood flow (CBF). The purpose of the present study was to measure the changes in coronary blood flow induced by intra-aortic balloon pump (IABP) counterpulsation in normal and reperfused porcine myocardium. METHODS: A 30-ml IABP was placed in the descending aorta of 6 open-chest pigs. Each pig underwent occlusion of the mid-left anterior descending (LAD) coronary artery for 1 h, followed by reperfusion for 2 h. The effects of IABP support on systolic aortic pressure (SAP) and aortic end-diastolic pressure were recorded. The mean CBF, distal to the LAD occlusion site was measured at baseline and during reperfusion, with and without IABP counterpulsation. RESULTS: The IABP decreased SAP and aortic end-diastolic pressure in normal and reperfused myocardium, and maintained a peak aortic diastolic augmentation at the level of SAP. In normal myocardium, the IABP decreased mean CBF by 8.4+/-2.2% (p<0.001). At 2, 15, 30, 60, 90 and 120 min of reperfusion, the IABP increased mean CBF by 11.5+/-6.8%, 8.0+/-7.0%, 11.2+/-6.9%, 12.4+/-12.9%, 23.5+/-9.9% and 8.9+/-6.9%, of the corresponding value without the assistance of the IABP (all p<0.05). CONCLUSIONS: In the normal heart, IABP counterpulsation decreased CBF, probably because of a decrease in myocardial oxygen demand from a decreased afterload. During reperfusion the IABP increased CBF, suggesting that it might effectively mitigate the no-reflow phenomenon.


Asunto(s)
Circulación Coronaria/fisiología , Contrapulsador Intraaórtico , Daño por Reperfusión Miocárdica/fisiopatología , Daño por Reperfusión Miocárdica/terapia , Reperfusión Miocárdica/métodos , Animales , Presión Sanguínea/fisiología , Diástole/fisiología , Modelos Animales de Enfermedad , Daño por Reperfusión Miocárdica/metabolismo , Miocardio , Consumo de Oxígeno/fisiología , Porcinos , Resistencia Vascular/fisiología , Presión Ventricular/fisiología
6.
J Card Surg ; 19(2): 134-5, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15016049

RESUMEN

A 44-year-old man presented with symptoms and signs of cardiac tamponade. Cytologic examination of the pericardial fluid was negative for malignancy and no manifestations of primary tumor were detected. Two weeks after pericardiocentesis the patient developed constrictive pericarditis. An emergency exploratory thoracotomy revealed a thick, fibrotic pericardium firmly adherent to the underlying myocardium. Histologic examination of the pericardium showed the presence of an adenocarcinoma, suspected to be a metastatic dissemination from a primary pulmonary source. The lymphatic spread of the tumor to the heart may explain the early development of pericardial effusion without malignant cells and the later development of pericardial and epicardial thickening. Cardiac tamponade of unknown origin should prompt a search for metastatic carcinoma, including in presence of a negative cytology.


Asunto(s)
Adenocarcinoma/diagnóstico , Taponamiento Cardíaco/diagnóstico , Taponamiento Cardíaco/etiología , Neoplasias Cardíacas/diagnóstico , Pericarditis Constrictiva/diagnóstico , Pericarditis Constrictiva/etiología , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Adenocarcinoma/secundario , Adenocarcinoma/cirugía , Adulto , Taponamiento Cardíaco/cirugía , Ecocardiografía , Neoplasias Cardíacas/secundario , Neoplasias Cardíacas/cirugía , Humanos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Masculino , Miocardio/patología , Derrame Pericárdico/patología , Derrame Pericárdico/cirugía , Pericarditis Constrictiva/cirugía , Pericardio/patología , Pericardio/cirugía , Radiografía Torácica , Choque Cardiogénico/cirugía , Toracotomía
7.
World J Surg ; 27(12): 1311-6, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-14586569

RESUMEN

The purpose of this study was to compare the hemodynamic effectiveness of a 30-ml stroke volume paraaortic counterpulsation device (PACD), presenting the advantages of ease of implantation and driving by a standard intraaortic balloon pump (IABP) console (Datascope 96, Datascope Corp., Montvale, NJ, USA) to that of a 40-ml IABP, in the setting of experimental heart failure. In an acute heart failure model, the IABP was placed in the descending aorta and the PACD in the ascending aorta of eight pigs. Both devices were driven by the same system, and hemodynamic measurements were obtained with and without mechanical assistance. The two pumps significantly reduced the systolic and end-diastolic aortic pressures, but the PACD reduced the latter more effectively (42.6 +/- 18.1% vs 11.0 +/- 9.9%, p = 0.0001). Both pumps provided significant aortic diastolic augmentation, but the counterpulsation wave of the PACD was significantly greater (augmentation of 44.8 +/- 22.2% vs 37.6 +/- 15.6%, p = 0.031). Both lowered the end-diastolic left ventricular pressure with a trend toward PACD superiority (24.2 +/- 13.7% vs 19.7 +/- 13.5%, p = 0.064). It is concluded that the PACD, even with smaller stroke volume, is more effective than the IABP. The simplicity of its implantation, together with the ability of the standard IABP consoles to control its function, make it a promising device for mechanical assistance of the failing heart.


Asunto(s)
Contrapulsación/instrumentación , Insuficiencia Cardíaca/terapia , Animales , Modelos Animales de Enfermedad , Diseño de Equipo , Insuficiencia Cardíaca/fisiopatología , Hemodinámica , Contrapulsador Intraaórtico/instrumentación , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA