Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Crit Care Med ; 51(5): e106-e114, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36877030

RESUMEN

OBJECTIVES: We performed a systemic review and meta-analysis to evaluate the diagnostic accuracy of monocyte distribution width (MDW) and to compare with procalcitonin and C-reactive protein (CRP), in adult patients with sepsis. DATA SOURCES: A systematic literature search was performed in PubMed, Embase, and the Cochrane Library to identify all relevant diagnostic accuracy studies published before October 1, 2022. STUDY SELECTION: Original articles reporting the diagnostic accuracy of MDW for sepsis detection with the Sepsis-2 or Sepsis-3 criteria were included. DATA EXTRACTION: Study data were abstracted by two independent reviewers using a standardized data extraction form. DATA SYNTHESIS: Eighteen studies were included in the meta-analysis. The pooled sensitivity and specificity of MDW were 84% (95% CI [79-88%]) and 68% (95% CI [60-75%]). The estimated diagnostic odds ratio and the area under the summary receiver operating characteristic curve (SROC) were 11.11 (95% CI [7.36-16.77]) and 0.85 (95% CI [0.81-0.89]). Significant heterogeneity was observed among the included studies. Eight studies compared the diagnostic accuracies of MDW and procalcitonin, and five studies compared the diagnostic accuracies of MDW and CRP. For MDW versus procalcitonin, the area under the SROC was similar (0.88, CI = 0.84-0.93 vs 0.82, CI = 0.76-0.88). For MDW versus CRP, the area under the SROC was similar (0.88, CI = 0.83-0.93 vs 0.86, CI = 0.78-0.95). CONCLUSIONS: The results of the meta-analysis indicate that MDW is a reliable diagnostic biomarker for sepsis as procalcitonin and CRP. Further studies investigating the combination of MDW and other biomarkers are advisable to increase the accuracy in sepsis detection.


Asunto(s)
Polipéptido alfa Relacionado con Calcitonina , Sepsis , Adulto , Humanos , Biomarcadores/análisis , Proteína C-Reactiva/análisis , Monocitos , Sepsis/diagnóstico
2.
Nanotechnology ; 34(24)2023 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-36917852

RESUMEN

This article addresses the synthesis of Fe3+doped TiO2nanoparticles with variations of molar concentrations of Fe3+and their adequate use as potential photocatalysts for Photocatalysis applications. Synthesized photocatalysts were characterized thoroughly by different analytical techniques in terms of morphological, chemical, structural, crystalline, optical, electronic structure, surface area etc properties. The occurrence of red shift phenomenon of the energy band gap attributes to the transfer of charges and transition between the d electrons of dopant and conduction band (CB) or valence band (VB) of TiO2. The doping of Fe3+ions generates more trap sites for charge carriers with the surface trap sites. Thorough experimental conclusions revealed that the Fe3+ions necessarily regulate the catalytic property of TiO2nanomaterial. The obtained total degradation efficiency rate of Methylene Blue (MB) was 93.3% in the presence of 0.1 M Fe3+in the host material and for Malachite Green Oxalate the efficiency was 100% in the presence of 0.05 M and 0.1 M Fe3+in the host material. In both the cases the total visible light irradiation time was 90 min. The adsorption properties of the photocatalysts have been also performed in a dark for 90 min in the presence of MB dye. However, till now there are hardly reported photocatalysts which shows complete degradation of these toxic organic dyes by visible light driven photocatalysis. of potential values of valence and conduction band shows the production of active oxidizing species for hydrogen yield and the possible mechanism of the Schottky barrier has been proposed. A schematic diagram of visible light driven Photocatalysis has been pictured showing degradation activity of Fe3+-TiO2catalysts sample.

3.
Sensors (Basel) ; 20(23)2020 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-33291519

RESUMEN

In recent years, with the rise of global diabetes, a growing number of subjects are suffering from pain and infections caused by the invasive nature of mainstream commercial glucose meters. Non-invasive blood glucose monitoring technology has become an international research topic and a new method which could bring relief to a vast number of patients. This paper reviews the research progress and major challenges of non-invasive blood glucose detection technology in recent years, and divides it into three categories: optics, microwave and electrochemistry, based on the detection principle. The technology covers medical, materials, optics, electromagnetic wave, chemistry, biology, computational science and other related fields. The advantages and limitations of non-invasive and invasive technologies as well as electrochemistry and optics in non-invasives are compared horizontally in this paper. In addition, the current research achievements and limitations of non-invasive electrochemical glucose sensing systems in continuous monitoring, point-of-care and clinical settings are highlighted, so as to discuss the development tendency in future research. With the rapid development of wearable technology and transdermal biosensors, non-invasive blood glucose monitoring will become more efficient, affordable, robust, and more competitive on the market.


Asunto(s)
Técnicas Biosensibles , Automonitorización de la Glucosa Sanguínea , Dispositivos Electrónicos Vestibles , Glucemia , Humanos , Monitoreo Fisiológico
4.
Molecules ; 24(10)2019 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-31100896

RESUMEN

The main causes of dysfunction after a spinal cord injury (SCI) include primary and secondary injuries that occur during the first minutes, hours, to days after injury. This treatable secondary cascade provides a window of opportunity for delivering therapeutic interventions. An S/B remedy (Scutellaria baicalensis Georgi and Bupleurum scorzonerifolfium Willd) has anti-inflammatory, cytoprotective, and anticarcinogenic effects in liver or neurodegenerative diseases. The present work examined the effect of S/B on injured spinal cord neurons in cultures and in vivo. S/B effectively reduced peroxide toxicity and lipopolysaccharide stimulation in both spinal cord neuron/glial and microglial cultures with the involvement of PKC and HSP70. The effect of S/B was further conducted in contusive SCI rats. Intraperitoneal injections of S/B to SCI rats preserved spinal cord tissues and effectively attenuated microglial activation. Consistently, S/B treatment significantly improved hindlimb functions of SCI rats. In the acute stage of injury, S/B treatment markedly reduced the levels of ED1 expression and lactate and had a tendency to decrease lipid peroxidation. Taken together, we demonstrated long-term hindlimb restoration alongside histological improvements with systemic S/B remedy treatment in a clinically relevant model of contusive SCI. Our findings highlight the potential of an S/B remedy for acute therapeutic intervention after SCI.


Asunto(s)
Bupleurum/química , Medicamentos Herbarios Chinos/farmacología , Fármacos Neuroprotectores/farmacología , Extractos Vegetales/farmacología , Scutellaria baicalensis/química , Traumatismos de la Médula Espinal/tratamiento farmacológico , Animales , Antiinflamatorios/química , Antiinflamatorios/farmacología , Antioxidantes/química , Antioxidantes/farmacología , Biomarcadores , Células Cultivadas , Modelos Animales de Enfermedad , Medicamentos Herbarios Chinos/química , Inmunohistoquímica , Microglía/efectos de los fármacos , Microglía/metabolismo , Neuronas/efectos de los fármacos , Neuronas/metabolismo , Estrés Oxidativo/efectos de los fármacos , Extractos Vegetales/química , Especies Reactivas de Oxígeno/metabolismo , Traumatismos de la Médula Espinal/etiología , Traumatismos de la Médula Espinal/metabolismo
5.
Sensors (Basel) ; 18(5)2018 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-29734708

RESUMEN

Skin penetration is related to efficiencies of drug delivery or ISF extraction. Normally, the macro-electrode is employed in skin permeability promotion and evaluation, which has the disadvantages of easily causing skin damage when using electroporation or reverse iontophoresis by alone; furthermore, it has large measurement error, low sensitivity, and difficulty in integration. To resolve these issues, this paper presents a flexible interdigital microelectrode for evaluating skin penetration by sensing impedance and a method of synergistical combination of electroporation and reverse iontophoresis to promote skin penetration. First, a flexible interdigital microelectrode was designed with a minimal configuration circuit of electroporation and reverse iontophoresis for future wearable application. Due to the variation of the skin impedance correlated with many factors, relative changes of it were recorded at the end of supply, different voltage, or constant current, times, and duration. It is found that the better results can be obtained by using electroporation for 5 min then reverse iontophoresis for 12 min. By synergistically using electroporation and reverse iontophoresis, the penetration of skin is promoted. The results tested in vivo suggest that the developed microelectrode can be applied to evaluate and promote the skin penetration and the designed method promises to leave the skin without damage. The electrode and the method may be beneficial for designing noninvasive glucose sensors.


Asunto(s)
Electroporación/métodos , Iontoforesis/métodos , Fenómenos Fisiológicos de la Piel , Diseño de Equipo , Glucosa/análisis , Humanos , Microelectrodos , Permeabilidad , Piel/metabolismo , Piel/patología , Dispositivos Electrónicos Vestibles
6.
Anal Biochem ; 534: 99-107, 2017 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-28709900

RESUMEN

In this study, we developed a screen-printed carbon-graphene-based electrochemical biosensor for EN2 protein detection. The engrailed-2 (EN2) protein, a biomarker for prostate cancer, is known to be a strong binder to a specific DNA sequence (5'-TAATTA-3') to regulate transcription. To take advantage of this intrinsic property, aptamer probes with TAATTA sequence was immobilized onto the screen-printed carbon-graphene electrode surface via EDC-NHS coupling approach. Cyclic voltammetry (CV) of the electrochemical measurement technique was employed for the quantitative detection of EN2 protein. The hindrance to the redox reaction of potassium ferricyanide on the biosensor surface due to the binding of the immobilized aptamer with its target EN2 protein quantified the protein concentration. Under optimum conditions, the aptamer biosensor can detect EN2 protein over a linear range from 35 to 185 nM with a detection limit of 38.5 nM.


Asunto(s)
Aptámeros de Nucleótidos/química , Técnicas Biosensibles , Carbono/química , Proteínas de Homeodominio/análisis , Proteínas del Tejido Nervioso/análisis , Técnicas Electroquímicas , Electrodos , Humanos
7.
Biosens Bioelectron ; 260: 116450, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38843770

RESUMEN

Continuous glucose monitoring (CGM) is of great importance to the treatment and prevention of diabetes. As a proven commercial technology, electrochemical glucose sensor based on interstitial fluid (ISF) sensing has high sensitivity and wide detection range. Therefore, it has good promotion prospects in noninvasive or minimally-invasive CGM system. However, since there are concentration differences and time lag between glucose in plasma and ISF, the accuracy of this type of sensors are still limited. Typical calibration algorithms rely on simple linear regression which do not account for the variability of the sensitivity of sensors. To enhance the accuracy and stability of CGM based on ISF, optimization of calibration algorithm for sensors is indispensable. While there have been considerable researches on improving calibration algorithms for CGM, they have still received less attention. This article reviews the problem of typical calibration and presents the outstanding calibration algorithms in recent years. Finally, combined with existing research and emerging sensing technologies, this paper makes an outlook on the future calibration algorithms for CGM sensors.


Asunto(s)
Algoritmos , Técnicas Biosensibles , Automonitorización de la Glucosa Sanguínea , Glucemia , Líquido Extracelular , Líquido Extracelular/química , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Calibración , Humanos , Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Diabetes Mellitus/sangre , Diabetes Mellitus/diagnóstico , Diseño de Equipo , Monitoreo Continuo de Glucosa
8.
Biosens Bioelectron ; 237: 115515, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37481866

RESUMEN

Interstitial fluid glucose sensors have promising prospects in noninvasive glucose monitoring. However, the commonly used method of extracting interstitial fluid, reverse iontophoresis (RI), still remains to be optimized to solve problems such as insufficient extraction flux and skin irritation. To find the optimal RI conditions, in this study we explored the effects of multiple factors such as current frequency, duration, duty cycle and their interactions on extraction with the design of experiments (DOE) method. A multifunctional extraction and detection device was designed to control extraction conditions and measure the surface water content of the extraction electrode in situ and real time. A micro glucose monitoring device (MicroTED) combined with a cheap and flexible paper-based electrode was developed under the determined optimal extraction conditions. In on-body continuous glucose monitoring tests carried out to verify the performance of the device, the optimized conditions can facilitate stable extraction of up to 1.0 mg without any skin discomfort. The mean Pearson correlation coefficient between the measurement results of MicroTED and commercial glucometer is above 0.9. In the Clarke error grid analysis, all data points fell within Clarke error grid areas A and B, demonstrating the feasibility of further clinical application of the device.


Asunto(s)
Técnicas Biosensibles , Glucemia , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Líquido Extracelular/química , Piel/química , Glucosa/análisis
9.
Carbohydr Polym ; 314: 120890, 2023 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-37173038

RESUMEN

Cartilage tissue engineering involves the invention of novel implantable cartilage replacement materials to help heal cartilage injuries that do not heal themselves, aiming to overcome the shortcomings of current clinical cartilage treatments. Chitosan has been widely used in cartilage tissue engineering because of its similar structure to glycine aminoglycan, which is widely distributed in connective tissues. The molecular weight, as an important structural parameter of chitosan, affects not only the method of chitosan composite scaffold preparation but also the effect on cartilage tissue healing. Thus, this review identifies methods for the preparation of chitosan composite scaffolds with low, medium and high molecular weights, as well as a range of chitosan molecular weights appropriate for cartilage tissue repair, by summarizing the application of different molecular weights of chitosan in cartilage repair in recent years.


Asunto(s)
Quitosano , Quitosano/química , Ingeniería de Tejidos , Peso Molecular , Andamios del Tejido/química , Cartílago
10.
Biomedicines ; 11(7)2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37509659

RESUMEN

BACKGROUND: The ossification of the posterior longitudinal ligament (OPLL) is one of the contributing factors leading to severe cervical spondylotic myelopathy (CSM). The mechanism causing ossification is still unclear. The current study was designed to analyze the specimens of patients with or without OPLL. METHODS: The study collected 51 patients with cervical spondylosis. There were six serum samples in both the non-OPLL (NOPLL) and OPLL groups. For tissue analysis, there were seven samples in the NOPLL group and five samples in the OPLL group. The specimens of serum and tissue were analyzed by using Human Cytokine Antibody Arrays to differentiate biomarkers between the OPLL and NOPLL groups, as well as between serum and OPLL tissue. Immunohistochemical staining of the ligament tissue was undertaken for both groups. RESULTS: For OPLL vs. NOPLL, the serum leptin levels are higher in the OPLL group, corroborating others' observations that it may serve as a disease marker. In the tissue, angiogenin (ANG), osteopontin (OPN), and osteopro-tegerin (OPG) are higher than they are in the OPLL group (p < 0.05). For serum vs. OPLL tissue, many chemotactic cytokines demonstrated elevated levels of MIP1 delta, MCP-1, and RANTES in the serum, while many cytokines promoting or regulating bone genesis were up-regulated in tissue (oncostatin M, FGF-9, LIF, osteopontin, osteoprotegerin, TGF-beta2), as well as the factor that inhibits osteoclastogenesis (IL-10), with very few cytokines responsible for osteoclastogenesis. Molecules promoting angiogenesis, including angiotensin, vEGF, and osteoprotegerin, are abundant in the OPLL tissue, which paves the way for robust bone growth.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA