Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Small ; : e2401465, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750613

RESUMEN

Lithium (Li) metal batteries have attracted considerable research attention due to their exceptionally high theoretical capacity. However, the commercialization of Li metal batteries faces challenges, primarily attributed to uncontrolled growth of Li dendrites, which raises safety concerns and lowers coulombic efficiency. To mitigate Li dendrites growth and attain dense Li deposition, the hybrid SiO2-Cu2O lithiophilic film applied to a 3D copper foam current collector is developed to regulate the interfacial properties for achieving even and dense Li deposition. The SiO2-Cu2O possesses strong Li+ trapping capability through strong lithiophilicity from Cu2O. Additionally, the SiO2-Cu2O enables uniform ion diffusion through the domain-limiting effect of the holes in the SiO2 layer, inducing an even and dense Li plating/stripping behavior at a large capacity. Furthermore, the SiO2 layer promotes the formation of an initial high inorganic content Solid Electrolyte Interphase (SEI) through selective preferential binding with anion and solvent molecules. When the SiO2-Cu2O@Li anode is coupled with a LiFePO4 (LFP) cathode, the resulting full cell exhibits superior cycling stability and rate performance. These results provide a facile approach to construct a lithiophilic current collector for practical Li metal anodes.

2.
Langenbecks Arch Surg ; 409(1): 154, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714551

RESUMEN

BACKGROUND: In recent years, there has been an increasing prevalence of patients with papillary thyroid microcarcinoma (PTMC) without lymph node involvement in medical centers worldwide. For patients who are unable to undergo active surveillance (AS) and are afraid of postoperative complications, conformal thyroidectomy may be a suitable option to ensure both preservation of function and complete removal of the tumor. METHODS: The patients in the cohort during 2010 to 2015 were retrospectively enrolled strictly following the inclusion and exclusion criteria. The observation and control groups were defined based on the surgical approach, with patients in the observation group undergoing conformal thyroidectomy and patients in the control group undergoing lobectomy. Event-free survival (EFS), the interval from initial surgery to the detection of recurrent or metastatic disease, was defined as the primary observation endpoint. RESULTS: A total of 319 patients were included in the study, with 124 patients undergoing conformal thyroidectomy and 195 patients undergoing lobectomy. When compared to lobectomy, conformal thyroidectomy demonstrated reduced hospital stays, shorter operative times, and lower rates of vocal cord paralysis and hypoparathyroidism. Furthermore, the mean bleeding volume during the operation and the rate of permanent hypothyroidism were also lower in the conformal thyroidectomy group than in the lobectomy group. However, there was no statistically significant difference observed in the 5- and 10-year EFS between the two groups. CONCLUSIONS: Conformal thyroidectomy had advantages in perioperative management and short-term complication rates, with an EFS that was not inferior to that of lobectomy. Thus, conformal thyroidectomy is a feasible option for low-risk PTMC patients.


Asunto(s)
Carcinoma Papilar , Neoplasias de la Tiroides , Tiroidectomía , Humanos , Tiroidectomía/métodos , Tiroidectomía/efectos adversos , Femenino , Masculino , Neoplasias de la Tiroides/cirugía , Neoplasias de la Tiroides/patología , Neoplasias de la Tiroides/mortalidad , Estudios Retrospectivos , Persona de Mediana Edad , Carcinoma Papilar/cirugía , Carcinoma Papilar/patología , Carcinoma Papilar/mortalidad , Adulto , Estudios de Seguimiento , Estudios de Factibilidad , Estudios de Cohortes , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento , Tempo Operativo
3.
Materials (Basel) ; 17(1)2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38203874

RESUMEN

Al2O3-forming austenitic steel (AFA steel) is an important candidate material for advanced reactor core components due to its excellent corrosion resistance and high temperature strength. Al is a strong ferrite-forming element. Therefore, it is necessary to increase the Ni content to stabilize austenite. Ni is expensive and highly active, and so increasing the Ni content not only increases the costs but also damages the radiation resistance. Mn is a low-cost austenitic stable element. Its substitution for Ni will not only help to improve the irradiation resistance of austenitic steel, but also reduce the cost. In order to explore the feasibility of Mn-substituted Ni-stabilized austenite in AFA steel, this paper summarized the research progress of Mn-added AFA steels, whilst the research status of traditional Mn-added austenitic steels are also referred to and compared herein. The effect of the addition of Mn on the microstructure and properties of AFA steel was analyzed. The results show that Mn can promote the precipitation of the M23C6 phase and inhibit the precipitation of the B2-NiAl phase and secondary NbC phase. With the increase in Mn content, the strength of AFA steel at room temperature and high temperature decreased slightly, the room temperature elongation increased slightly, while the high temperature elongation and creep resistance decreased obviously. In addition, for austenitic steel free of Al, the addition of Mn will destroy the oxide layer of Cr2O3, which will decrease the oxidation resistance of the steel. But the preliminary study shows that Mn has little effect on the Al2O3 oxide layer. It is worth studying the effect of Mn-substituted Ni on the oxidation resistance of AFA steel. In summary, more efforts are necessary to investigate the optimal Mn content to balance the advantages and disadvantages of introducing Mn instead of Ni.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA