Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 85(1): 152-167, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32697891

RESUMEN

PURPOSE: To propose a novel combined parallel imaging and deep learning-based reconstruction framework for robust reconstruction of highly accelerated 2D cardiac cine MRI data. METHODS: We propose DL-ESPIRiT, an unrolled neural network architecture that utilizes an extended coil sensitivity model to address SENSE-related field-of-view (FOV) limitations in previously proposed deep learning-based reconstruction frameworks. Additionally, we propose a novel neural network design based on (2+1)D spatiotemporal convolutions to produce more accurate dynamic MRI reconstructions than conventional 3D convolutions. The network is trained on fully sampled 2D cardiac cine datasets collected from 11 healthy volunteers with IRB approval. DL-ESPIRiT is compared against a state-of-the-art parallel imaging and compressed sensing method known as l1 -ESPIRiT. The reconstruction accuracy of both methods is evaluated on retrospectively undersampled datasets (R = 12) with respect to standard image quality metrics as well as automatic deep learning-based segmentations of left ventricular volumes. Feasibility of DL-ESPIRiT is demonstrated on two prospectively undersampled datasets acquired in a single heartbeat per slice. RESULTS: The (2+1)D DL-ESPIRiT method produces higher fidelity image reconstructions when compared to l1 -ESPIRiT reconstructions with respect to standard image quality metrics (P < .001). As a result of improved image quality, segmentations made from (2+1)D DL-ESPIRiT images are also more accurate than segmentations from l1 -ESPIRiT images. CONCLUSIONS: DL-ESPIRiT synergistically combines a robust parallel imaging model and deep learning-based priors to produce high-fidelity reconstructions of retrospectively undersampled 2D cardiac cine data acquired with reduced FOV. Although a proof-of-concept is shown, further experiments are necessary to determine the efficacy of DL-ESPIRiT in prospectively undersampled data.


Asunto(s)
Aprendizaje Profundo , Corazón , Imagen por Resonancia Cinemagnética , Corazón/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Estudios Retrospectivos
2.
Magn Reson Med ; 85(5): 2608-2621, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33432613

RESUMEN

PURPOSE: To enable motion-robust, ungated, free-breathing R2∗ mapping of hepatic iron overload in children with 3D multi-echo UTE cones MRI. METHODS: A golden-ratio re-ordered 3D multi-echo UTE cones acquisition was developed with chemical-shift encoding (CSE). Multi-echo complex-valued source images were reconstructed via gridding and coil combination, followed by confounder-corrected R2∗ (=1/ T2∗ ) mapping. A phantom containing 15 different concentrations of gadolinium solution (0-300 mM) was imaged at 3T. 3D multi-echo UTE cones with an initial TE of 0.036 ms and Cartesian CSE-MRI (IDEAL-IQ) sequences were performed. With institutional review board approval, 85 subjects (81 pediatric patients with iron overload + 4 healthy volunteers) were imaged at 3T using 3D multi-echo UTE cones with free breathing (FB cones), IDEAL-IQ with breath holding (BH Cartesian), and free breathing (FB Cartesian). Overall image quality of R2∗ maps was scored by 2 blinded experts and compared by a Wilcoxon rank-sum test. For each pediatric subject, the paired R2∗ maps were assessed to determine if a corresponding artifact-free 15 mm region-of-interest (ROI) could be identified at a mid-liver level on both images. Agreement between resulting R2∗ quantification from FB cones and BH/FB Cartesian was assessed with Bland-Altman and linear correlation analyses. RESULTS: ROI-based regression analysis showed a linear relationship between gadolinium concentration and R2∗ in IDEAL-IQ (y = 8.83x - 52.10, R2 = 0.995) as well as in cones (y = 9.19x - 64.16, R2 = 0.992). ROI-based Bland-Altman analysis showed that the mean difference (MD) was 0.15% and the SD was 5.78%. However, IDEAL-IQ R2∗ measurements beyond 200 mM substantially deviated from a linear relationship for IDEAL-IQ (y = 5.85x + 127.61, R2 = 0.827), as opposed to cones (y = 10.87x - 166.96, R2 = 0.984). In vivo, FB cones R2∗ had similar image quality with BH and FB Cartesian in 15 and 42 cases, respectively. FB cones R2∗ had better image quality scores than BH and FB Cartesian in 3 and 21 cases, respectively, where BH/FB Cartesian exhibited severe ghosting artifacts. ROI-based Bland-Altman analyses were 2.23% (MD) and 6.59% (SD) between FB cones and BH Cartesian and were 0.21% (MD) and 7.02% (SD) between FB cones and FB Cartesian, suggesting a good agreement between FB cones and BH (FB) Cartesian R2∗ . Strong linear relationships were observed between BH Cartesian and FB cones (y = 1.00x + 1.07, R2 = 0.996) and FB Cartesian and FB cones (y = 0.98x + 1.68, R2 = 0.999). CONCLUSION: Golden-ratio re-ordered 3D multi-echo UTE Cones MRI enabled motion-robust, ungated, and free-breathing R2∗ mapping of hepatic iron overload, with comparable R2∗ measurements and image quality to BH Cartesian, and better image quality than FB Cartesian.


Asunto(s)
Aumento de la Imagen , Sobrecarga de Hierro , Niño , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Sobrecarga de Hierro/diagnóstico por imagen , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Respiración
3.
J Magn Reson Imaging ; 53(5): 1594-1605, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33382171

RESUMEN

The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Neoplasias de la Mama , Imagen de Difusión por Resonancia Magnética , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Imagen Eco-Planar , Femenino , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos
4.
Magn Reson Med ; 84(4): 1763-1780, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32270547

RESUMEN

PURPOSE: To develop a framework to reconstruct large-scale volumetric dynamic MRI from rapid continuous and non-gated acquisitions, with applications to pulmonary and dynamic contrast-enhanced (DCE) imaging. THEORY AND METHODS: The problem considered here requires recovering 100 gigabytes of dynamic volumetric image data from a few gigabytes of k-space data, acquired continuously over several minutes. This reconstruction is vastly under-determined, heavily stressing computing resources as well as memory management and storage. To overcome these challenges, we leverage intrinsic three-dimensional (3D) trajectories, such as 3D radial and 3D cones, with ordering that incoherently cover time and k-space over the entire acquisition. We then propose two innovations: (a) A compressed representation using multiscale low-rank matrix factorization that constrains the reconstruction problem, and reduces its memory footprint. (b) Stochastic optimization to reduce computation, improve memory locality, and minimize communications between threads and processors. We demonstrate the feasibility of the proposed method on DCE imaging acquired with a golden-angle ordered 3D cones trajectory and pulmonary imaging acquired with a bit-reversed ordered 3D radial trajectory. We compare it with "soft-gated" dynamic reconstruction for DCE and respiratory-resolved reconstruction for pulmonary imaging. RESULTS: The proposed technique shows transient dynamics that are not seen in gating-based methods. When applied to datasets with irregular, or non-repetitive motions, the proposed method displays sharper image features. CONCLUSIONS: We demonstrated a method that can reconstruct massive 3D dynamic image series in the extreme undersampling and extreme computation setting.


Asunto(s)
Medios de Contraste , Interpretación de Imagen Asistida por Computador , Algoritmos , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética
5.
Magn Reson Med ; 84(2): 800-812, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32011021

RESUMEN

PURPOSE: To rapidly reconstruct undersampled 3D non-Cartesian image-based navigators (iNAVs) using an unrolled deep learning (DL) model, enabling nonrigid motion correction in coronary magnetic resonance angiography (CMRA). METHODS: An end-to-end unrolled network is trained to reconstruct beat-to-beat 3D iNAVs acquired during a CMRA sequence. The unrolled model incorporates a nonuniform FFT operator in TensorFlow to perform the data-consistency operation, and the regularization term is learned by a convolutional neural network (CNN) based on the proximal gradient descent algorithm. The training set includes 6,000 3D iNAVs acquired from 7 different subjects and 11 scans using a variable-density (VD) cones trajectory. For testing, 3D iNAVs from 4 additional subjects are reconstructed using the unrolled model. To validate reconstruction accuracy, global and localized motion estimates from DL model-based 3D iNAVs are compared with those extracted from 3D iNAVs reconstructed with l1 -ESPIRiT. Then, the high-resolution coronary MRA images motion corrected with autofocusing using the l1 -ESPIRiT and DL model-based 3D iNAVs are assessed for differences. RESULTS: 3D iNAVs reconstructed using the DL model-based approach and conventional l1 -ESPIRiT generate similar global and localized motion estimates and provide equivalent coronary image quality. Reconstruction with the unrolled network completes in a fraction of the time compared to CPU and GPU implementations of l1 -ESPIRiT (20× and 3× speed increases, respectively). CONCLUSIONS: We have developed a deep neural network architecture to reconstruct undersampled 3D non-Cartesian VD cones iNAVs. Our approach decreases reconstruction time for 3D iNAVs, while preserving the accuracy of nonrigid motion information offered by them for correction.


Asunto(s)
Aprendizaje Profundo , Angiografía por Resonancia Magnética , Angiografía Coronaria , Corazón , Humanos , Imagenología Tridimensional
6.
J Magn Reson Imaging ; 51(3): 841-853, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31322799

RESUMEN

BACKGROUND: Current self-calibration and reconstruction methods for wave-encoded single-shot fast spin echo imaging (SSFSE) requires long computational time, especially when high accuracy is needed. PURPOSE: To develop and investigate the clinical feasibility of data-driven self-calibration and reconstruction of wave-encoded SSFSE imaging for computation time reduction and quality improvement. STUDY TYPE: Prospective controlled clinical trial. SUBJECTS: With Institutional Review Board approval, the proposed method was assessed on 29 consecutive adult patients (18 males, 11 females, range, 24-77 years). FIELD STRENGTH/SEQUENCE: A wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable 3.5× acceleration with full-Fourier acquisitions. Data-driven calibration of wave-encoding point-spread function (PSF) was developed using a trained deep neural network. Data-driven reconstruction was developed with another set of neural networks based on the calibrated wave-encoding PSF. Training of the calibration and reconstruction networks was performed on 15,783 2D wave-encoded SSFSE abdominal images. ASSESSMENT: Image quality of the proposed data-driven approach was compared independently and blindly with a conventional approach using iterative self-calibration and reconstruction with parallel imaging and compressed sensing by three radiologists on a scale from -2 to 2 for noise, contrast, sharpness, artifacts, and confidence. Computation time of these two approaches was also compared. STATISTICAL TESTS: Wilcoxon signed-rank tests were used to compare image quality and two-tailed t-tests were used to compare computation time with P values of under 0.05 considered statistically significant. RESULTS: An average 2.1-fold speedup in computation was achieved using the proposed method. The proposed data-driven self-calibration and reconstruction approach significantly reduced the perceived noise level (mean scores 0.82, P < 0.0001). DATA CONCLUSION: The proposed data-driven calibration and reconstruction achieved twice faster computation with reduced perceived noise, providing a fast and robust self-calibration and reconstruction for clinical abdominal SSFSE imaging. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:841-853.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Magnética , Adulto , Anciano , Artefactos , Calibración , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
7.
J Cardiovasc Magn Reson ; 22(1): 33, 2020 05 14.
Artículo en Inglés | MEDLINE | ID: mdl-32404159

RESUMEN

BACKGROUND: 3D-time resolved flow (4DF) cardiovascular magnetic resonance (CMR) with retrospective analysis of atrioventricular valve regurgitation (AVVR) allows for internal validation by multiple direct and indirect methods. Limited data exist on direct measurement of AVVR by 4DF CMR in pediatric congenital heart disease (CHD). We aimed to validate direct measurement of the AVVR jet as accurate and reliable compared to the volumetric method (clinical standard by 2D CMR) and as a superior method of internal validation than the annular inflow method. METHODS: We identified 44 consecutive patients with diverse CHD referred for evaluation of AVVR by CMR. 1.5 T or 3 T scanners, intravenous contrast, and a combination of parallel imaging and compressed sensing were used. Four methods of measuring AVVR volume (RVol) were used: volumetric method (VOL; the clinical standard) = stroke volume by 2D balanced steady-state free precession - semilunar valve forward flow (SLFF); annular inflow method (AIM) = atrioventricular valve forward flow [AVFF] - semilunar valve net flow (SLNF); and direct measurement (JET). AVFF was measured using static and retrospective valve tracking planes. SLFF, SLNF, AVFF, and JET were measured by 4DF phase contrast. Regurgitant fraction was calculated as [RVol/(RVol+SLNF)]× 100. Statistical methods included Spearman, Wilcoxon rank sum test/Student paired t-test, Bland Altman analysis, and intra-class coefficient (ICC), where appropriate. RESULTS: Regurgitant fraction by JET strongly correlated with the indirect methods (VOL and AIM) (ρ = 0.73-0.80, p < 0.001) and was similar to VOL with a median difference (interquartile range) of - 1.5% (- 8.3-7.2%; p = 0.624). VOL had weaker correlations with AIM and JET (ρ = 0.69-0.73, p < 0.001). AIM underestimated RF by 3.6-6.9% compared to VOL and JET, p < 0.03. Intra- and inter- observer reliability were excellent for all methods (ICC 0.94-0.99). The mean (±standard deviation) inter-observer difference for VOL was 2.4% (±5.1%), p < 0.05. CONCLUSIONS: In a diverse cohort of pediatric CHD, measurement of AVVR using JET is accurate and reliable to VOL and is a superior method of internal validation compared to AIM. This study supports use of 4DF CMR for measurement of AVVR, obviating need for expert prospective prescription during image acquisition by 2D CMR.


Asunto(s)
Cardiopatías Congénitas/diagnóstico por imagen , Hemodinámica , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Adolescente , Factores de Edad , Niño , Preescolar , Femenino , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/cirugía , Humanos , Masculino , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/fisiopatología , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/fisiopatología , Adulto Joven
8.
IEEE Signal Process Mag ; 37(1): 111-127, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33192036

RESUMEN

Compressed sensing (CS) reconstruction methods leverage sparse structure in underlying signals to recover high-resolution images from highly undersampled measurements. When applied to magnetic resonance imaging (MRI), CS has the potential to dramatically shorten MRI scan times, increase diagnostic value, and improve overall patient experience. However, CS has several shortcomings which limit its clinical translation such as: 1) artifacts arising from inaccurate sparse modelling assumptions, 2) extensive parameter tuning required for each clinical application, and 3) clinically infeasible reconstruction times. Recently, CS has been extended to incorporate deep neural networks as a way of learning complex image priors from historical exam data. Commonly referred to as unrolled neural networks, these techniques have proven to be a compelling and practical approach to address the challenges of sparse CS. In this tutorial, we will review the classical compressed sensing formulation and outline steps needed to transform this formulation into a deep learning-based reconstruction framework. Supplementary open source code in Python will be used to demonstrate this approach with open databases. Further, we will discuss considerations in applying unrolled neural networks in the clinical setting.

9.
Magn Reson Med ; 81(2): 1092-1103, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30370941

RESUMEN

PURPOSE: To develop a 3D cones steady-state free precession sequence with improved robustness to respiratory motion while mitigating eddy current artifacts for free-breathing whole-heart coronary magnetic resonance angiography. METHOD: The proposed sequence collects cone interleaves using a phyllotaxis pattern, which allows for more distributed k-space sampling for each heartbeat compared to a typical sequential collection pattern. A Fibonacci number of segments is chosen to minimize eddy current effects with the trade-off of an increased number of acquisition heartbeats. For verification, phyllotaxis-cones is compared to sequential-cones through simulations, phantom studies, and in vivo coronary scans with 8 subjects using 2D image-based navigators for retrospective motion correction. RESULTS: Simulated point spread functions and moving phantom results show less coherent motion artifacts for phyllotaxis-cones compared to sequential-cones. Assessment of the right and left coronary arteries using reader scores and the image edge profile acutance vessel sharpness metric indicate superior image quality and sharpness for phyllotaxis-cones. CONCLUSION: Phyllotaxis 3D cones results in improved qualitative image scores and coronary vessel sharpness for free-breathing whole-heart coronary magnetic resonance angiography compared to standard sequential ordering when using a steady-state free precession sequence.


Asunto(s)
Angiografía Coronaria , Corazón/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética , Algoritmos , Artefactos , Simulación por Computador , Vasos Coronarios , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Movimiento (Física) , Fantasmas de Imagen , Respiración , Estudios Retrospectivos
10.
Magn Reson Med ; 82(4): 1398-1411, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31115936

RESUMEN

PURPOSE: To enable rapid imaging with a scan time-efficient 3D cones trajectory with a deep-learning off-resonance artifact correction technique. METHODS: A residual convolutional neural network to correct off-resonance artifacts (Off-ResNet) was trained with a prospective study of pediatric MRA exams. Each exam acquired a short readout scan (1.18 ms ± 0.38) and a long readout scan (3.35 ms ± 0.74) at 3 T. Short readout scans, with longer scan times but negligible off-resonance blurring, were used as reference images and augmented with additional off-resonance for supervised training examples. Long readout scans, with greater off-resonance artifacts but shorter scan time, were corrected by autofocus and Off-ResNet and compared with short readout scans by normalized RMS error, structural similarity index, and peak SNR. Scans were also compared by scoring on 8 anatomical features by two radiologists, using analysis of variance with post hoc Tukey's test and two one-sided t-tests. Reader agreement was determined with intraclass correlation. RESULTS: The total scan time for long readout scans was on average 59.3% shorter than short readout scans. Images from Off-ResNet had superior normalized RMS error, structural similarity index, and peak SNR compared with uncorrected images across ±1 kHz off-resonance (P < .01). The proposed method had superior normalized RMS error over -677 Hz to +1 kHz and superior structural similarity index and peak SNR over ±1 kHz compared with autofocus (P < .01). Radiologic scoring demonstrated that long readout scans corrected with Off-ResNet were noninferior to short readout scans (P < .05). CONCLUSION: The proposed method can correct off-resonance artifacts from rapid long-readout 3D cones scans to a noninferior image quality compared with diagnostically standard short readout scans.


Asunto(s)
Aprendizaje Profundo , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Artefactos , Niño , Preescolar , Femenino , Humanos , Masculino , Fantasmas de Imagen , Venas Pulmonares/diagnóstico por imagen
11.
Radiology ; 289(2): 366-373, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30040039

RESUMEN

Purpose To develop a deep learning reconstruction approach to improve the reconstruction speed and quality of highly undersampled variable-density single-shot fast spin-echo imaging by using a variational network (VN), and to clinically evaluate the feasibility of this approach. Materials and Methods Imaging was performed with a 3.0-T imager with a coronal variable-density single-shot fast spin-echo sequence at 3.25 times acceleration in 157 patients referred for abdominal imaging (mean age, 11 years; range, 1-34 years; 72 males [mean age, 10 years; range, 1-26 years] and 85 females [mean age, 12 years; range, 1-34 years]) between March 2016 and April 2017. A VN was trained based on the parallel imaging and compressed sensing (PICS) reconstruction of 130 patients. The remaining 27 patients were used for evaluation. Image quality was evaluated in an independent blinded fashion by three radiologists in terms of overall image quality, perceived signal-to-noise ratio, image contrast, sharpness, and residual artifacts with scores ranging from 1 (nondiagnostic) to 5 (excellent). Wilcoxon tests were performed to test the hypothesis that there was no significant difference between VN and PICS. Results VN achieved improved perceived signal-to-noise ratio (P = .01) and improved sharpness (P < .001), with no difference in image contrast (P = .24) and residual artifacts (P = .07). In terms of overall image quality, VN performed better than did PICS (P = .02). Average reconstruction time ± standard deviation was 5.60 seconds ± 1.30 per section for PICS and 0.19 second ± 0.04 per section for VN. Conclusion Compared with the conventional parallel imaging and compressed sensing reconstruction (PICS), the variational network (VN) approach accelerates the reconstruction of variable-density single-shot fast spin-echo sequences and achieves improved overall image quality with higher perceived signal-to-noise ratio and sharpness. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Abdomen/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Artefactos , Niño , Preescolar , Aprendizaje Profundo , Imagen Eco-Planar , Estudios de Factibilidad , Femenino , Humanos , Lactante , Masculino , Relación Señal-Ruido , Adulto Joven
12.
Magn Reson Med ; 80(1): 112-125, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29159989

RESUMEN

PURPOSE: To develop a general phase regularized image reconstruction method, with applications to partial Fourier imaging, water-fat imaging and flow imaging. THEORY AND METHODS: The problem of enforcing phase constraints in reconstruction was studied under a regularized inverse problem framework. A general phase regularized reconstruction algorithm was proposed to enable various joint reconstruction of partial Fourier imaging, water-fat imaging and flow imaging, along with parallel imaging (PI) and compressed sensing (CS). Since phase regularized reconstruction is inherently non-convex and sensitive to phase wraps in the initial solution, a reconstruction technique, named phase cycling, was proposed to render the overall algorithm invariant to phase wraps. The proposed method was applied to retrospectively under-sampled in vivo datasets and compared with state of the art reconstruction methods. RESULTS: Phase cycling reconstructions showed reduction of artifacts compared to reconstructions without phase cycling and achieved similar performances as state of the art results in partial Fourier, water-fat and divergence-free regularized flow reconstruction. Joint reconstruction of partial Fourier + water-fat imaging + PI + CS, and partial Fourier + divergence-free regularized flow imaging + PI + CS were demonstrated. CONCLUSION: The proposed phase cycling reconstruction provides an alternative way to perform phase regularized reconstruction, without the need to perform phase unwrapping. It is robust to the choice of initial solutions and encourages the joint reconstruction of phase imaging applications. Magn Reson Med 80:112-125, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Tejido Adiposo/patología , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Algoritmos , Artefactos , Compresión de Datos , Bases de Datos Factuales , Análisis de Fourier , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Neuroimagen/métodos , Distribución Normal , Reproducibilidad de los Resultados , Estudios Retrospectivos , Grabación en Video , Agua
13.
Magn Reson Med ; 79(6): 2944-2953, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-28994486

RESUMEN

PURPOSE: To mitigate artifacts from through-plane flow at the locations of steady-state stopbands in balanced steady-state free precession (SSFP) using partial dephasing. METHODS: A 60° range in the phase accrual during a TR was created over the voxel by slightly unbalancing the slice-select dephaser. The spectral profiles of SSFP with partial dephasing for various constant flow rates and during pulsatile flow were simulated to determine if partial dephasing decreases through-plane flow artifacts originating near SSFP dark bands while maintaining on-resonant signal. Simulations were then validated in a flow phantom. Lastly, phase-cycled SSFP cardiac cine images were acquired with and without partial dephasing in six subjects. RESULTS: Partial dephasing decreased the strength and non-linearity of the dependence of the signal at the stopbands on the through-plane flow rate. It thus mitigated hyper-enhancement from out-of-slice signal contributions and transient-related artifacts caused by variable flow both in the phantom and in vivo. In six volunteers, partial dephasing noticeably decreased artifacts in all of the phase-cycled cardiac cine datasets. CONCLUSION: Partial dephasing can mitigate the flow artifacts seen at the stopbands in balanced SSFP while maintaining the sequence's desired signal. By mitigating hyper-enhancement and transient-related artifacts originating from the stopbands, partial dephasing facilitates robust multiple-acquisition phase-cycled SSFP in the heart. Magn Reson Med 79:2944-2953, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Cinemagnética , Algoritmos , Artefactos , Simulación por Computador , Voluntarios Sanos , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Fantasmas de Imagen , Flujo Pulsátil , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Relación Señal-Ruido
14.
J Magn Reson Imaging ; 47(1): 200-209, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28570032

RESUMEN

PURPOSE: To assess the feasibility and performance of conical k-space trajectory free-breathing ultrashort echo time (UTE) chest magnetic resonance imaging (MRI) versus four-dimensional (4D) flow and effects of 50% data subsampling and soft-gated motion correction. MATERIALS AND METHODS: Thirty-two consecutive children who underwent both 4D flow and UTE ferumoxytol-enhanced chest MR (mean age: 5.4 years, range: 6 days to 15.7 years) in one 3T exam were recruited. From UTE k-space data, three image sets were reconstructed: 1) one with all data, 2) one using the first 50% of data, and 3) a final set with soft-gating motion correction, leveraging the signal magnitude immediately after each excitation. Two radiologists in blinded fashion independently scored image quality of anatomical landmarks on a 5-point scale. Ratings were compared using Wilcoxon rank-sum, Wilcoxon signed-ranks, and Kruskal-Wallis tests. Interobserver agreement was assessed with the intraclass correlation coefficient (ICC). RESULTS: For fully sampled UTE, mean scores for all structures were ≥4 (good-excellent). Full UTE surpassed 4D flow for lungs and airways (P < 0.001), with similar pulmonary artery (PA) quality (P = 0.62). 50% subsampling only slightly degraded all landmarks (P < 0.001), as did motion correction. Subsegmental PA visualization was possible in >93% scans for all techniques (P = 0.27). Interobserver agreement was excellent for combined scores (ICC = 0.83). CONCLUSION: High-quality free-breathing conical UTE chest MR is feasible, surpassing 4D flow for lungs and airways, with equivalent PA visualization. Data subsampling only mildly degraded images, favoring lesser scan times. Soft-gating motion correction overall did not improve image quality. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:200-209.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Adolescente , Algoritmos , Niño , Estudios de Cohortes , Medios de Contraste , Femenino , Óxido Ferrosoférrico/química , Humanos , Pulmón/diagnóstico por imagen , Masculino , Movimiento (Física) , Variaciones Dependientes del Observador , Arteria Pulmonar/diagnóstico por imagen , Radiología , Respiración , Relación Señal-Ruido
15.
J Magn Reson Imaging ; 47(4): 954-966, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28906567

RESUMEN

BACKGROUND: It is highly desirable in clinical abdominal MR scans to accelerate single-shot fast spin echo (SSFSE) imaging and reduce blurring due to T2 decay and partial-Fourier acquisition. PURPOSE: To develop and investigate the clinical feasibility of wave-encoded variable-density SSFSE imaging for improved image quality and scan time reduction. STUDY TYPE: Prospective controlled clinical trial. SUBJECTS: With Institutional Review Board approval and informed consent, the proposed method was assessed on 20 consecutive adult patients (10 male, 10 female, range, 24-84 years). FIELD STRENGTH/SEQUENCE: A wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable high acceleration (3.5×) with full-Fourier acquisitions by: 1) introducing wave encoding with self-refocusing gradient waveforms to improve acquisition efficiency; 2) developing self-calibrated estimation of wave-encoding point-spread function and coil sensitivity to improve motion robustness; and 3) incorporating a parallel imaging and compressed sensing reconstruction to reconstruct highly accelerated datasets. ASSESSMENT: Image quality was compared pairwise with standard Cartesian acquisition independently and blindly by two radiologists on a scale from -2 to 2 for noise, contrast, confidence, sharpness, and artifacts. The average ratio of scan time between these two approaches was also compared. STATISTICAL TESTS: A Wilcoxon signed-rank tests with a P value under 0.05 considered statistically significant. RESULTS: Wave-encoded variable-density SSFSE significantly reduced the perceived noise level and improved the sharpness of the abdominal wall and the kidneys compared with standard acquisition (mean scores 0.8, 1.2, and 0.8, respectively, P < 0.003). No significant difference was observed in relation to other features (P = 0.11). An average of 21% decrease in scan time was achieved using the proposed method. DATA CONCLUSION: Wave-encoded variable-density sampling SSFSE achieves improved image quality with clinically relevant echo time and reduced scan time, thus providing a fast and robust approach for clinical SSFSE imaging. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:954-966.


Asunto(s)
Abdomen/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
16.
J Magn Reson Imaging ; 48(4): 1147-1158, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29638024

RESUMEN

BACKGROUND: In patients with mitral or tricuspid valve regurgitation, evaluation of regurgitant severity is essential for determining the need for surgery. While transthoracic echocardiography is widely accessible, it has limited reproducibility for grading inlet valve regurgitation. Multiplanar cardiac MRI is the quantitative standard but requires specialized local expertise, and is thus not widely available. Volumetric 4D flow MRI has potential for quantitatively grading the severity of inlet valve regurgitation in adult patients. PURPOSE: To evaluate the accuracy and reproducibility of volumetric 4D flow MRI for quantification of inlet valvular regurgitation compared to conventional multiplanar MRI, which may simplify and improve accessibility of cardiac MRI. STUDY TYPE: This retrospective, HIPAA-compliant imaging-based comparison study was conducted at a single institution. SUBJECTS: Twenty-one patients who underwent concurrent multiplanar and 4D flow cardiac MRI between April 2015 and January 2017. FIELD STRENGTH/SEQUENCES: 3T; steady-state free-precession (SSFP), 2D phase contrast (2D-PC), and postcontrast 4D flow. ASSESSMENT: We evaluated the intertechnique (4D flow vs. 2D-PC), intermethod (direct vs. indirect measurement), interobserver and intraobserver reproducibility of measurements of regurgitant flow volume (RFV), fraction (RF), and volume (RVol). STATISTICAL TESTS: Statistical analysis included Pearson correlation, Bland-Altman statistics, and intraclass correlation coefficients. RESULTS: There was high concordance between 4D flow and multiplanar MRI, whether using direct or indirect methods of quantifying regurgitation (r = 0.813-0.985). Direct interrogation of the regurgitant jet with 4D flow showed high intraobserver consistency (r = 0.976-0.999) and interobserver consistency (r = 0.861-0.992), and correlated well with traditional indirect measurements obtained as the difference between stroke volume and forward outlet valve flow. DATA CONCLUSION: 4D flow MRI provides highly reproducible measurements of mitral and tricuspid regurgitant volume, and may be used in place of conventional multiplanar MRI. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:1147-1158.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Volumen Sistólico , Factores de Tiempo , Adulto Joven
17.
Magn Reson Med ; 78(5): 1757-1766, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-27943402

RESUMEN

PURPOSE: To develop a motion-robust wave-encoding technique for highly accelerated free-breathing abdominal MRI. METHODS: A comprehensive 3D wave-encoding-based method was developed to enable fast free-breathing abdominal imaging: (a) auto-calibration for wave-encoding was designed to avoid extra scan for coil sensitivity measurement; (b) intrinsic butterfly navigators were used to track respiratory motion; (c) variable-density sampling was included to enable compressed sensing; (d) golden-angle radial-Cartesian hybrid view-ordering was incorporated to improve motion robustness; and (e) localized rigid motion correction was combined with parallel imaging compressed sensing reconstruction to reconstruct the highly accelerated wave-encoded datasets. The proposed method was tested on six subjects and image quality was compared with standard accelerated Cartesian acquisition both with and without respiratory triggering. Inverse gradient entropy and normalized gradient squared metrics were calculated, testing whether image quality was improved using paired t-tests. RESULTS: For respiratory-triggered scans, wave-encoding significantly reduced residual aliasing and blurring compared with standard Cartesian acquisition (metrics suggesting P < 0.05). For non-respiratory-triggered scans, the proposed method yielded significantly better motion correction compared with standard motion-corrected Cartesian acquisition (metrics suggesting P < 0.01). CONCLUSION: The proposed methods can reduce motion artifacts and improve overall image quality of highly accelerated free-breathing abdominal MRI. Magn Reson Med 78:1757-1766, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Abdomen/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Artefactos , Femenino , Humanos , Masculino , Movimiento/fisiología , Fantasmas de Imagen , Adulto Joven
18.
Magn Reson Med ; 77(5): 1884-1893, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-27174673

RESUMEN

PURPOSE: To develop a retrospective nonrigid motion-correction method based on 3D image-based navigators (iNAVs) for free-breathing whole-heart coronary magnetic resonance angiography (MRA). METHODS: The proposed method detects global rigid-body motion and localized nonrigid motion from 3D iNAVs and compensates them with an autofocusing algorithm. To model the global motion, 3D rotation and translation are estimated from the 3D iNAVs. Two sets of localized nonrigid motions are obtained from deformation fields between 3D iNAVs and reconstructed binned images, respectively. A bank of motion-corrected images is generated and the final image is assembled pixel-by-pixel by selecting the best focused pixel from this bank. In vivo studies with six healthy volunteers were conducted to compare the performance of the proposed method with 3D translational motion correction and no correction. RESULTS: In vivo studies showed that compared to no correction, 3D translational motion correction and the proposed method increased the vessel sharpness by 13% ± 13% and 19% ± 16%, respectively. Out of 90 vessel segments, 75 segments showed improvement with the proposed method compared to 3D translational correction. CONCLUSION: We have developed a nonrigid motion-correction method based on 3D iNAVs and an autofocusing algorithm that improves the vessel sharpness of free-breathing whole-heart coronary MRA. Magn Reson Med 77:1884-1893, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Angiografía Coronaria/métodos , Corazón/diagnóstico por imagen , Imagenología Tridimensional/métodos , Adulto , Algoritmos , Artefactos , Análisis por Conglomerados , Femenino , Voluntarios Sanos , Corazón/fisiología , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética , Masculino , Movimiento (Física) , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
19.
J Magn Reson Imaging ; 45(5): 1407-1418, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-27678106

RESUMEN

PURPOSE: To assess the feasibility of ferumoxytol-enhanced anesthesia-free cardiac MRI in neonates and young infants for complex congenital heart disease (CHD). MATERIALS AND METHODS: With Institutional Review Board approval, 21 consecutive neonates and young infants (1 day to 11 weeks old; median age of 3 days) who underwent a rapid two-sequence (MR angiography [MRA] and four-dimensional [4D] flow) MRI protocol with intravenous ferumoxytol without sedation (n = 17) or light sedation (n = 4) at 3 Tesla (T) (except one case at 1.5T) between June 2014 and February 2016 were retrospectively identified. Medical records were reviewed for indication, any complications, if further diagnostic imaging was performed after MRI, and surgical findings. Two radiologists scored the images in two sessions on a 5-point scale for overall image quality and delineation of various anatomical structures. Confidence interval of proportions for likelihood of requiring additional diagnostic imaging after MRI was determined. For the possibility of reducing the protocol to a single rapid sequence, Wilcoxon-rank sum test was used to assess whether 4D flow and MRA significantly differed in anatomical delineation. RESULTS: One of 21 patients (4.8%, 80% confidence interval 0-11%) required additional imaging, a computed tomography angiography to assess lung parenchyma and peripheral pulmonary arteries. Only 1 of 13 patients (7.7%) with operative confirmation had a minor discrepancy between radiology and operative reports (80% confidence interval 0-17%). 4D flow was significantly superior to MRA (P < 0.05) for the evaluation of systemic arteries, valves, ventricular trabeculae, and overall quality. Using Cohen's kappa coefficient, there was good interobserver agreement for the evaluation of systemic arteries by 4D flow (κ = 0.782), and systemic veins and pulmonary arteries by MRA (κ > 0.6). Overall 4D flow measurements (mean κ = 0.64-0.74) had better internal agreement compared with MRA (mean κ = 0.30-0.64). CONCLUSION: Ferumoxytol-enhanced cardiac MRI, without anesthesia, is feasible for the evaluation of complex CHD in neonates and young infants, with a low likelihood of need for additional diagnostic studies. The decreased risk by avoiding anesthesia must be balanced against the potential for adverse reactions with ferumoxytol. LEVEL OF EVIDENCE: 2 J. MAGN. RESON. IMAGING 2017;45:1407-1418.


Asunto(s)
Óxido Ferrosoférrico/química , Cardiopatías Congénitas/diagnóstico por imagen , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Miocardio/patología , Anestesia General , Medios de Contraste , Estudios de Factibilidad , Femenino , Cardiopatías Congénitas/patología , Humanos , Imagenología Tridimensional/métodos , Lactante , Recién Nacido , Pulmón/diagnóstico por imagen , Pulmón/patología , Angiografía por Resonancia Magnética , Masculino , Variaciones Dependientes del Observador , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/patología , Estudios Retrospectivos
20.
Magn Reson Med ; 76(1): 197-205, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26220204

RESUMEN

PURPOSE: To develop a robust motion estimation method for free-breathing body MRI using dense coil arrays. METHODS: Self-navigating pulse sequences can measure subject motion without using external motion monitoring devices. With dense coil arrays, individual coil elements can provide localized motion estimates. An averaged motion estimate over all coils is often used for motion compensation. However, this motion estimate may not accurately represent the dominant motion within the imaging volume. In this work, a coil clustering method is proposed to automatically determine the dominant motion for dense coil arrays. The feasibility of the proposed method is investigated in free-breathing abdominal MRI and cardiac MRI, and compared with manual motion estimate selection for respiratory motion estimation and electrocardiography for cardiac motion estimation. RESULTS: Automated motion estimation achieved similar respiratory motion estimation compared to manual selection (averaged correlation coefficient 0.989 and 0.988 for abdominal MRI and cardiac MRI, respectively), and accurate cardiac triggering compared to electrocardiography (averaged temporal variability 17.5 ms). CONCLUSION: The proposed method can provide accurate automated motion estimation for body MRI using dense coil arrays. It can enable self-navigated free-breathing abdominal and cardiac MRI without the need for external motion monitoring devices. Magn Reson Med 76:197-205, 2016. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Artefactos , Técnicas de Imagen Sincronizada Cardíacas/instrumentación , Técnicas de Imagen Sincronizada Cardíacas/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Técnicas de Imagen Sincronizada Respiratorias/instrumentación , Técnicas de Imagen Sincronizada Respiratorias/métodos , Diseño de Equipo , Humanos , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Magnetismo/instrumentación , Magnetismo/métodos , Movimiento (Física) , Movimiento , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA