1.
Magn Reson Med ; 85(6): 3497-3509, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33314274

RESUMEN

PURPOSE: B1+ shimming is an important method for mitigating B1 inhomogeneity in high-field MRI. Using independent power amplifiers for each transmit (Tx) element is the preferred method for B1 shimming but comes with a high cost. Conversely, the simplest approach to control a Tx array is by using coaxial cables of varying length in the Tx chain, but this approach is cumbersome and impractical for dynamic shimming. In this article, a system is described that enables dynamic, phase-only, eight-channel B1+ steering on a 7T MR scanner with only two power amplifiers. METHODS: Power dividers were utilized to first split the existing two-channel Tx signal into eight channels. Digitally controlled phase shifters on each channel were designed to provide independent phase shifts with a resolution of 22.5° (from 0°, 22.5° … 337.5°). To validate the system, an eight-channel body dipole array was simulated and constructed for bench and 7T imaging and evaluation. RESULTS: The phase conjugate B1+ steering method was employed at three different spatial positions in simulation, bench measurements, and scanner measurements-all with matching results. At the desired points, regions with homogenous B1+ were generated, indicating good Tx steering to the selected region. CONCLUSION: The described system can be used as a simple retrofit to existing hardware to provide phase control while avoiding the need to manually switch cables and without requiring independent power amplifiers for each channel, thus demonstrating the ability to perform dynamic B1+ shimming with increased degrees of freedom but without significantly increased hardware cost.


Asunto(s)
Amplificadores Electrónicos , Imagen por Resonancia Magnética , Simulación por Computador , Diseño de Equipo , Fantasmas de Imagen
2.
Magn Reson Med ; 85(1): 551-559, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32820540

RESUMEN

PURPOSE: This work describes the construction and evaluation of a bilateral 32-channel receive array for breast imaging at 7T. METHODS: The receive array consisted of 32 receive coils, placed on two 3D-printed hemispherical formers. Each side of the receive array consisted of 16 receive loops, each loop having a corresponding detachable board with match/tune capacitors, active detuning circuitry, and a balun. Coil performance was evaluated on homogeneous canola oil phantoms using a Philips Achieva 7T system. Array coil performance was compared with a bilateral forced current excitation volume coil in transmit/receive mode and with a previously reported 16-channel unilateral coil with a similar design. RESULTS: The 32-channel array had an increase in average SNR throughout both phantoms by a factor of five as compared with the volume coil, with SNR increases up to 10 times along the periphery and three times in the center. Noise measurements showed low interelement noise correlation (average: 5.4%; maximum: 16.8%). Geometry factor maps were acquired for various acceleration factors and showed mean geometry factors <1.2, for combined acceleration factors of up to six. CONCLUSIONS: The improvements achieved demonstrate the clear potential for use in dynamic contrast-enhanced or diffusion-weighted MR studies, while maintaining diagnostically relevant spatial and temporal resolutions.


Asunto(s)
Mama , Imagen por Resonancia Magnética , Mama/diagnóstico por imagen , Diseño de Equipo , Fantasmas de Imagen , Relación Señal-Ruido , Análisis Espectral
3.
Magn Reson Med ; 78(6): 2065-2071, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28112825

RESUMEN

PURPOSE: Disorders of brain energy metabolism and neurotransmitter recycling have been implicated in multiple neurological conditions. 13 C magnetic resonance spectroscopy (13 C MRS) during intravenous administration of 13 C-labeled compounds has been used to measure turnover rates of brain metabolites. This approach, however, requires prolonged infusion inside the magnet. Proton decoupling is typically required but may be difficult to implement with standard equipment. We examined an alternative approach to monitor glucose metabolism in the human brain. METHODS: 13 C-enriched glucose was infused in healthy subjects outside the magnet to a steady-state level of 13 C enrichment. Subsequently, the subjects were scanned at 7T for 60 min without 1 H decoupling. Metabolic modeling was used to calculate anaplerosis. RESULTS: Biomarkers of energy metabolism and anaplerosis were detected. The glutamate C5 doublet provided information about glucose-derived acetyl-coenzyme A flux into the tricarboxylic acid (TCA) cycle via pyruvate dehydrogenase, and the bicarbonate signal reflected overall TCA cycle activity. The glutamate C1/C5 ratio is sensitive to anaplerosis. CONCLUSION: Brain 13 C MRS at 7T provides information about glucose oxidation and anaplerosis without the need of prolonged 13 C infusions inside the scanner and without technical challenges of 1 H decoupling, making it a feasible approach for clinical research. Magn Reson Med 78:2065-2071, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Encéfalo/diagnóstico por imagen , Isótopos de Carbono/química , Glucosa/química , Oxígeno/química , Encéfalo/metabolismo , Ciclo del Ácido Cítrico , Estudios de Factibilidad , Humanos , Procesamiento de Imagen Asistido por Computador , Cetona Oxidorreductasas/metabolismo , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Magnetismo , Masculino , Neurotransmisores , Protones
4.
Concepts Magn Reson Part B Magn Reson Eng ; 46B(4): 162-168, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28529464

RESUMEN

Performing multinuclear experiments requires one or more radiofrequency (RF) coils operating at both the proton and second-nucleus frequencies; however, inductive coupling between coils must be mitigated to retain proton sensitivity and coil tuning stability. The inclusion of trap circuits simplifies placement of multinuclear RF coils while maintaining inter-element isolation. Of the commonly investigated non-proton nuclei, perhaps the most technically demanding is carbon-13, particularly when applying a proton decoupling scheme to improve the resulting spectra. This work presents experimental data for trap circuits withstanding high-power broadband proton decoupling of carbon-13 at 7 T. The advantages and challenges of building trap circuits with various inductor and capacitor components are discussed. Multiple trap designs are evaluated on the bench and utilized on an RF coil at 7 T to detect broadband proton-decoupled carbon-13 spectra from a lipid phantom. A particular trap design, built from a coaxial stub inductor and high-voltage ceramic chip capacitors, is highlighted owing to both its performance and adaptability for planar array coil elements with diverse spatial orientations.

5.
J Magn Reson Imaging ; 40(5): 1165-73, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24459091

RESUMEN

PURPOSE: To demonstrate the use of forced current excitation (FCE) to create homogeneous excitation of the breast at 7 tesla, insensitive to the effects of asymmetries in the electrical environment. MATERIALS AND METHODS: FCE was implemented on two breast coils: one for quadrature (1) H imaging and one for proton-decoupled (13) C spectroscopy. Both were a Helmholtz-saddle combination, with the saddle tuned to 298 MHz for imaging and 75 MHz for spectroscopy. Bench measurements were acquired to demonstrate the ability to force equal currents on elements in the presence of asymmetric loading to improve homogeneity. Modeling and temperature measurements were conducted per safety protocol. B1 mapping, imaging, and proton-decoupled (13) C spectroscopy were demonstrated in vivo. RESULTS: Using FCE to ensure balanced currents on elements enabled straightforward tuning and maintaining of isolation between quadrature elements of the coil. Modeling and bench measurements confirmed homogeneity of the field, which resulted in images with excellent fat suppression and in broadband proton-decoupled carbon-13 spectra. CONCLUSION: FCE is a straightforward approach to ensure equal currents on multiple coil elements and a homogeneous excitation field, insensitive to the effects of asymmetries in the electrical environment. This enabled effective breast imaging and proton-decoupled carbon-13 spectroscopy at 7T.


Asunto(s)
Artefactos , Neoplasias de la Mama/diagnóstico , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Imagen por Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/instrumentación , Mama/patología , Campos Electromagnéticos , Diseño de Equipo , Femenino , Humanos , Fantasmas de Imagen , Valores de Referencia , Programas Informáticos
6.
Appl Opt ; 50(14): 2088-97, 2011 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-21556110

RESUMEN

An optically based rigid-body six-degrees of freedom (DOF) measurement system optimized for prospective (real-time) motion correction in magnetic resonance imaging (MRI) applications is described. By optimizing system capabilities to the specific applications requirements, the six-DOF measurement is accomplished using a single camera and simple three-disc fiducial at rates of 50 Hz. The algorithm utilizes successive approximation to solve the three point pose problem for angles close to the origin. Convergence to submicroradian levels occurs within 20 iterations for angles in an approximate half-radian (29°) arc centered on the origin. The overall absolute accuracy of the instrument is 10-100 µm for translational and <100 µrad (0.005°) for rotational motions. Results for head nodding and speech tasks are presented for subjects in the MR scanner, and the instrument results are compared to standard prospective acquisition correction.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética/métodos , Óptica y Fotónica/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Movimientos de la Cabeza , Humanos , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Movimiento (Física)
7.
IEEE Trans Biomed Eng ; 68(6): 2036-2046, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33651680

RESUMEN

OBJECTIVE: Considering the reported elevation of ω-6/ω-3 fatty acid ratios in breast neoplasms, one particularly important application of 13C MRS could be in more fully understanding the breast lipidome's relationship to breast cancer incidence. However, the low natural abundance and gyromagnetic ratio of the 13C isotope lead to detection sensitivity challenges. Previous 13C MRS studies have relied on the use of small surface coils with limited field-of-view and shallow penetration depths to achieve adequate signal-to-noise ratio (SNR), and the use of receive array coils is still mostly unexplored. METHODS: This work presents a unilateral breast 16-channel 13C array coil and interfacing hardware designed to retain the surface sensitivity of a single small loop coil while improving penetration depth and extending the field-of-view over the entire breast at 7T. The coil was characterized through bench measurements and phantom 13C spectroscopy experiments. RESULTS: Bench measurements showed receive coil matching better than -17 dB and average preamplifier decoupling of 16.2 dB with no evident peak splitting. Phantom MRS studies show better than a three-fold increase in average SNR over the entirety of the breast region compared to volume coil reception alone as well as an ability for individual array elements to be used for coarse metabolite localization without the use of single-voxel or spectroscopic imaging methods. CONCLUSION: Our current study has shown the benefits of the array. Future in vivo lipidomics studies can be pursued. SIGNIFICANCE: Development of the 16-channel breast array coil opens possibilities of in vivo lipidomics studies to elucidate the link between breast cancer incidence and lipid metabolics.


Asunto(s)
Mama , Imagen por Resonancia Magnética , Mama/diagnóstico por imagen , Diseño de Equipo , Humanos , Espectroscopía de Resonancia Magnética , Fantasmas de Imagen , Relación Señal-Ruido
8.
IEEE Trans Biomed Eng ; 68(1): 109-118, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32746012

RESUMEN

OBJECTIVE: Most MRI scanners are equipped to receive signals from 1H array coils but few support multi-channel reception for other nuclei. Using receive arrays can provide significant SNR benefits, usually exploited to enable accelerated imaging, but the extension of these arrays to non-1H nuclei has received less attention because of the relative lack of broadband array receivers. Non-1H nuclei often have low sensitivity and stand to benefit greatly from the increase in SNR that arrays can provide. This paper presents a cost-effective approach for adapting standard 1H multi-channel array receivers for use with other nuclei - in this case, 13C. METHODS: A frequency translation system has been developed that uses active mixers residing at the magnet bore to convert the received signal from a non-1H array to the 1H frequency for reception by the host system receiver. RESULTS: This system has been demonstrated at 4.7T and 7T while preserving SNR and isolation. 1H decoupling, particularly important for 13C detection, can be straightforwardly accommodated. CONCLUSION: Frequency translation can convert 1H-only multi-channel receivers for use with other nuclei while maintaining SNR and channel isolation while still enabling 1H decoupling. SIGNIFICANCE: This work allows existing multi-channel MRI receivers to be adapted to receive signals from nuclei other than 1H, allowing for the use of receive arrays for in vivo multi-nuclear NMR.


Asunto(s)
Imagen por Resonancia Magnética , Diseño de Equipo , Espectroscopía de Resonancia Magnética , Fantasmas de Imagen , Relación Señal-Ruido
9.
Hum Brain Mapp ; 30(4): 1105-19, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18465746

RESUMEN

Task-correlated motion artifacts that occur during functional magnetic resonance imaging can be mistaken for brain activity. In this work, a new selective detrending method for reduction of artifacts associated with task-correlated motion (TCM) during speech in event-related functional magnetic resonance imaging is introduced and demonstrated in an overt word generation paradigm. The performance of this new method is compared with that of three existing methods for reducing artifacts because of TCM: (1) motion parameter regression, (2) ignoring images during speech, and (3) detrending time course datasets of signal components related to TCM (deduced from artifact corrupted voxels). The selective detrending method outperforms the other three methods in reducing TCM artifacts and in retaining blood oxygenation level dependent signal.


Asunto(s)
Artefactos , Encéfalo/irrigación sanguínea , Imagen por Resonancia Magnética , Movimiento (Física) , Habla/fisiología , Algoritmos , Mapeo Encefálico , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Análisis de Regresión , Procesamiento de Señales Asistido por Computador
10.
IEEE Trans Biomed Eng ; 65(10): 2259-2266, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29989961

RESUMEN

Ultrahigh field imaging of the body and the spine is challenging due to the large field-of-view (FOV) required. It is especially difficult for RF transmission due to its requirement on both the length and the depth of the ${\rm{B}}_{1}^{{\rm + }}$ field. One solution is to use a long dipole to provide continuous current distribution. The drawback is the natural falloff of the ${\rm{B}}_{1}$ field toward the ends of the dipole, therefore the ${\rm{B}}_{1}^{{\rm + }}$ per unit square root of maximum specific absorption rate ${\rm{(B}}_{1}^{{\rm + }}{\rm{/ \surd SAR}}_{{\rm{max}}})$ performance is particularly poor toward the end of the dipole. In this study, a segmented element design using forced-current excitation and a switching circuit is presented. The design provides long FOV when desired and allows flexible FOV switching and power distribution without additional power amplifiers. Different element types and arrangements were explored and a segmented dipole design was chosen as the best design. The segmented dipole was implemented and tested on the bench and with a phantom on a 7T whole body scanner. The switchable mode dipole enabled a large FOV in the long mode and improved ${\rm{B}}_{1}^{{\rm + }}{\rm{/ \surd SAR}}_{{\rm{max}}}$ efficiency in a smaller FOV in the short mode.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo , Imagen de Cuerpo Entero/instrumentación
11.
IEEE Trans Biomed Eng ; 62(7): 1777-83, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25706501

RESUMEN

In high-field magnetic resonance imaging, the radio frequency wavelength within the human body is comparable to anatomical dimensions, resulting in B1 inhomogeneity and nonuniform sensitivity patterns. Thus, this relatively short wavelength presents engineering challenges for RF coil design. In this study, a bilateral breast coil for (1)H imaging at 7 T was designed and constructed using forced-current excitation. By forcing equal current through the coil elements, we reduce the effects of coupling between the elements to simplify tuning and to ensure a uniform field across both breasts. To combine the benefits of the higher power efficiency of a unilateral coil with the bilateral coverage of a bilateral coil, a switching circuit was implemented to allow the coil to be reconfigured for imaging the left, right, or both breasts.


Asunto(s)
Mama/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador
12.
PLoS One ; 9(10): e108706, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25296331

RESUMEN

Carbon-13 magnetic resonance spectroscopy (13C MRS) offers a noninvasive method to assess glycogen levels in skeletal muscle and to identify excess glycogen accumulation in patients with glycogen storage disease (GSD). Despite the clinical potential of the method, it is currently not widely used for diagnosis or for follow-up of treatment. While it is possible to perform acceptable 13C MRS at lower fields, the low natural abundance of 13C and the inherently low signal-to-noise ratio of 13C MRS makes it desirable to utilize the advantage of increased signal strength offered by ultra-high fields for more accurate measurements. Concomitant with this advantage, however, ultra-high fields present unique technical challenges that need to be addressed when studying glycogen. In particular, the question of measurement reproducibility needs to be answered so as to give investigators insight into meaningful inter-subject glycogen differences. We measured muscle glycogen levels in vivo in the calf muscle in three patients with McArdle disease (MD), one patient with phosphofructokinase deficiency (PFKD) and four healthy controls by performing 13C MRS at 7T. Absolute quantification of the MRS signal was achieved by using a reference phantom with known concentration of metabolites. Muscle glycogen concentration was increased in GSD patients (31.5±2.9 g/kg w. w.) compared with controls (12.4±2.2 g/kg w. w.). In three GSD patients glycogen was also determined biochemically in muscle homogenates from needle biopsies and showed a similar 2.5-fold increase in muscle glycogen concentration in GSD patients compared with controls. Repeated inter-subject glycogen measurements yield a coefficient of variability of 5.18%, while repeated phantom measurements yield a lower 3.2% system variability. We conclude that noninvasive ultra-high field 13C MRS provides a valuable, highly reproducible tool for quantitative assessment of glycogen levels in health and disease.


Asunto(s)
Espectroscopía de Resonancia Magnética con Carbono-13/métodos , Enfermedad del Almacenamiento de Glucógeno/metabolismo , Glucógeno/metabolismo , Músculo Esquelético/metabolismo , Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
13.
PLoS One ; 9(11): e113969, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25420018

RESUMEN

PURPOSE: To enable high spatial and temporal breast imaging resolution via combined use of high field MRI, array coils, and forced current excitation (FCE) multi channel transmit. MATERIALS AND METHODS: A unilateral 16-channel receive array insert was designed for use in a transmit volume coil optimized for quadrature operation with dual-transmit RF shimming at 7 T. Signal-to-noise ratio (SNR) maps, g-factor maps, and high spatial and temporal resolution in vivo images were acquired to demonstrate the utility of the coil architecture. RESULTS: The dual-transmit FCE coil provided homogeneous excitation and the array provided an increase in average SNR of 3.3 times (max 10.8, min 1.5) compared to the volume coil in transmit/receive mode. High resolution accelerated in vivo breast imaging demonstrated the ability to achieve isotropic spatial resolution of 0.5 mm within clinically relevant 90 s scan times, as well as the ability to perform 1.0 mm isotropic resolution imaging, 7 s per dynamics, with the use of bidirectional SENSE acceleration of up to R = 9. CONCLUSION: The FCE design of the transmit coil easily accommodates the addition of a sixteen channel array coil. The improved spatial and temporal resolution provided by the high-field array coil with FCE dual-channel transmit will ultimately be beneficial in lesion detection and characterization.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Mama/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/prevención & control , Diseño de Equipo , Femenino , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Relación Señal-Ruido
14.
IEEE Trans Biomed Eng ; 55(2 Pt 1): 563-71, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18269991

RESUMEN

This paper presents a set of validation procedures for nonrigid registration of functional EPI to anatomical MRI brain images. Although various registration techniques have been developed and validated for high-resolution anatomical MRI images, due to a lack of quantitative and qualitative validation procedures, the use of nonrigid registration between functional EPI and anatomical MRI images has not yet been deployed in neuroimaging studies. In this paper, the performance of a robust formulation of a nonrigid registration technique is evaluated in a quantitative manner based on simulated data and is further evaluated in a quantitative and qualitative manner based on in vivo data as compared to the commonly used rigid and affine registration techniques in the neuroimaging software packages. The nonrigid registration technique is formulated as a second-order constrained optimization problem using a free-form deformation model and mutual information similarity measure. Bound constraints, resolution level and cross-validation issues have been discussed to show the degree of accuracy and effectiveness of the nonrigid registration technique. The analyses performed reveal that the nonrigid approach provides a more accurate registration, in particular when the functional regions of interest lie in regions distorted by susceptibility artifacts.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/anatomía & histología , Encéfalo/fisiología , Potenciales Evocados/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Técnica de Sustracción , Algoritmos , Humanos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
J Opt Soc Am A Opt Image Sci Vis ; 25(7): 1551-7, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18594610

RESUMEN

An accurate motion-tracking technique is needed to compensate for subject motion during functional magnetic resonance imaging (fMRI) procedures. Here, a novel approach to motion metrology is discussed. A structured light pattern specifically coded for digital signal processing is positioned onto a fiduciary of the patient. As the patient undergoes spatial transformations in 6 DoF (degrees of freedom), a high-resolution CCD camera captures successive images for analysis on a computing platform. A high-speed image processing algorithm is used to calculate spatial transformations in a time frame commensurate with patient movements (10-100 ms) and with a precision of at least 0.5 microm for translations and 0.1 deg for rotations.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Óptica y Fotónica , Algoritmos , Computadores , Diseño de Equipo , Análisis de Fourier , Humanos , Procesamiento de Imagen Asistido por Computador , Luz , Modelos Estadísticos , Fantasmas de Imagen , Procesamiento de Señales Asistido por Computador , Programas Informáticos , Factores de Tiempo