Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Med Educ ; 24(1): 970, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39238012

RESUMEN

BACKGROUND: Clinicians from multiple professional backgrounds are increasingly using point-of-care ultrasound in clinical practice. Performing ultrasound is a complex skill, and training is required to ensure competency and patient safety. There is a lack of skilled trainers within health professions to meet this increasing educational demand. The role of sonographers in educating other health professionals in point-of-care ultrasound has not yet been well defined. Sonographers can provide ultrasound education interprofessionally, if equipped with appropriate clinical knowledge and educational skills. METHODS: A Delphi consensus study was conducted to define the knowledge, skills and attributes required of sonographers teaching point-of-care ultrasound to other health professionals in Australia and New Zealand. Health professionals with subject matter expertise in the leadership, facilitation, and delivery of ultrasound education by sonographers were invited to participate. RESULTS: There were 72 expert participants in survey round one, and 49 in round two. Participants included physicians, sonographers, and other health professionals. Consensus was reached on 31 competency items for sonographers teaching ultrasound interprofessionally, with agreement of greater than 94% reached by participants. CONCLUSIONS: This consensus study has defined the knowledge, skills and attitudes required for sonographer competence in point-of-care ultrasound education. This is an important step to developing a training pathway for sonographers engaging in this emerging area.


Asunto(s)
Competencia Clínica , Consenso , Técnica Delphi , Sistemas de Atención de Punto , Ultrasonografía , Humanos , Australia , Nueva Zelanda , Ultrasonografía/normas
2.
Heart Lung Circ ; 33(7): 1067-1073, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38458932

RESUMEN

BACKGROUND & AIM: Echocardiography education involves the teaching and assessment of multiple competencies to ensure work-ready graduates. To connect these competency standards to professional practice, it is important that the industry expectation around specific entrustable professional activities (EPAs) is determined. In Australia, echocardiography examinations are eligible for Medicare reimbursement when performed by sonographers listed on the Australian Sonographers Accreditation Registry (ASAR), either as an Accredited Medical Sonographer or as an Accredited Student Sonographer. A key criterion for acceptance onto the registry is the completion of, or active enrolment in, an accredited cardiac sonography course. Eligible courses apply for accreditation and are assessed by ASAR against their Standards for Accreditation of Sonographer Courses. This study sought to investigate the existing cardiac EPAs and provide insights into the industry's expectations for graduate cardiac sonographers in Australia. METHODS: Using an anonymous online survey tool, an invitation to participate was circulated via professional sonography groups and social media platforms. Accredited Medical Sonographers, Accredited Student Sonographers or interested stakeholders (academic, employer, medical specialist) working in Australia or New Zealand were invited to complete the survey. Survey questions were structured around the existing EPAs and knowledge items described in published sonography competency documents. Participants were asked if each individual EPA should be considered appropriate at the threshold of graduation, or at a higher level following a period of working in the profession. RESULTS: There were 211 cardiac sonographers who completed the survey. The majority of respondents (148 of 211, 72.2%) indicated that the current EPAs should be updated. At 80% agreement, the following EPAs were considered essential for the graduate: left ventricular structure and function, right ventricular structure and function, atrial size, valvular disease, systemic hypertension, cardiomyopathies, diseases of the aorta, coronary artery disease, pulmonic hypertension, and basic congenital heart disease. This list is more extensive than the current ASAR-endorsed EPAs, and the findings in this research will guide the revision of current ASAR-endorsed EPAs for graduate-level cardiac sonography. CONCLUSIONS: The results of this study show Accredited Medical Sonographers completing a cardiac sonography course in Australia should be entrusted to perform a wide range of examinations however, greater alignment between educational providers, ASAR and industry is still required.


Asunto(s)
Competencia Clínica , Ecocardiografía , Humanos , Ecocardiografía/normas , Australia , Encuestas y Cuestionarios , Femenino , Masculino , Acreditación , Adulto
3.
Int J Qual Health Care ; 34(2)2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35311894

RESUMEN

BACKGROUND: Professional competencies are important for enhancing alignment between the needs of education, industry and health consumers, whilst describing public expectations around health professionals. The development of competency standards for the sonography profession defines the behaviours, skills and knowledge sonographers should demonstrate for each learning and experience level. OBJECTIVE: The objective of this project was to develop a set of professional competency standards for the sonography profession which described in depth the behaviours, skills and knowledge sonographers should demonstrate across multiple learning and experience levels. METHODS: Representatives of three Australian ultrasound professional associations and seven tertiary institutions involved in entry-level sonographer education in Australia formed a research team (RT). The RT recruited an expert panel that responded to six survey rounds. Using a Delphi methodology, the results and free-text comments from each previous round were fed back to participants in the subsequent survey rounds to achieve a consensus. RESULTS: The project developed a professional competency framework for sonographers, which included four major domains: detailed competency standards, sonographer knowledge, sonographer attitudes and a holistic competency matrix [https://doi.org/10.6084/m9.figshare.17148035.v2.]. CONCLUSION: The Delphi methodology is an effective way to develop professional competency standards. This paper describes the methods and challenges in developing such standards for sonographers which could be translated to other health professionals.


Asunto(s)
Personal de Salud , Competencia Profesional , Australia , Competencia Clínica , Consenso , Técnica Delphi , Humanos
4.
J Ultrasound Med ; 39(8): 1477-1490, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32083336

RESUMEN

Endometriosis is a common gynecologic condition affecting as many as 1 per 10 women. Transvaginal ultrasound (TVUS) has become a frontline tool in the diagnosis of deep infiltrating endometriosis (DIE) before surgery. The primary aim of this review was to determine the accuracy of TVUS for DIE. The secondary aim was to determine accuracy specifically when a sonographer performed the TVUS examination. A systematic review was performed, searching literature by following a population, intervention, comparator, and outcome outline. MEDLINE, Embase, Emcare, and Google Scholar were searched in July 2018 and in November 2019. Including "sonographer" in the search terms yielded no results, so our terms were expanded. Two hundred and four articles were returned from the searches, and 35 were ultimately included in the final review. Analysis of the returned articles revealed the TVUS is a valuable diagnostic tool for DIE before surgery. Sensitivities ranged from 78.5% to 85.3%, specificities from 46.1% to 92.5%, and accuracies from 75.7% to 97%. Most authors reported site-specific sensitivities and specificities, which varied greatly between locations. Site-specific sensitivities ranged from 10% to 88.9% (uterosacral ligaments), 20% to 100% (bladder), 33.3% to 98.1% (rectosigmoid colon), and 31% to 98.7% (pouch of Douglas). Site-specific specificities ranged from 75% to 99.6% (uterosacral ligaments), 96.4% to 100% (bladder), 86% to 100% (rectosigmoid colon), and 90% to 100% (pouch of Douglas). Transvaginal ultrasound is an accurate tool in the diagnosis of DIE; however, limited data exist as to whether this technique is accurate when performed by sonographers. More evidence surrounding the reliability between operators is also needed.


Asunto(s)
Endometriosis , Endometriosis/diagnóstico por imagen , Endometriosis/cirugía , Femenino , Humanos , Recto/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía
5.
Appl Nurs Res ; 42: 83-88, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30029719

RESUMEN

BACKGROUND: Accessing the peripheral veins for blood sampling and short-term peripheral intravenous catheter insertion is common in contemporary healthcare. Clinicians may apply heat or promote oral hydration to increase vein diameter and reveal veins to improve success rates. However, there is limited research that has examined the effect of these interventions on vein diameter and depth. OBJECTIVES: To determine the effect of localised heat and oral hydration on vein diameter and depth. DESIGN: A three arm parallel randomised controlled trial was undertaken with 39 healthy participants from a University. All participants fasted from food and fluid from midnight. At 10 am the next day, a mark was made at the cephalic (120 mm proximal from the radial styloid) and median cubital veins (at cubital fossa) with non-permanent ink and participants underwent baseline vein diameter and depth measurement using ultrasound. Participants were randomised to either a control, heat or hydration group. Participants in the hydration arm consumed 1 L of room temperature tap water, those in the heat group had a wheat bag applied to the area for 10 min and those in the control group had no intervention and were asked to sit quietly. A second measurement was undertaken immediately after the heat intervention and 1 h after the baseline measurement for those in the hydration and control groups. RESULTS: The application of localised heat and oral hydration did not affect the depth of the cephalic vein. Whilst hydration had no effect on median cubital vein depth, the application of heat did make this vein more superficial compared to the control group (p = 0.033). The application of heat resulted in a statistically significant (p = 0.006) increase in cephalic vein diameter compared to the control group, this effect did not occur with the median cubital vein (p = 0.087). Oral hydration resulted in a reduction in the mean diameter of both veins. Compared to the control group, the average median cubital vein diameter decreased by 0.57 mm (p = 0.003; 95% CI -0.940 to -0.193) and the cephalic vein reduced by 0.33 mm (p = 0.015; 95% CI -0.593 to -0.064) after oral hydration. CONCLUSION: The use of localised heat was inconsistent in its effect on vein diameter and depth. Oral hydration caused a reduction in vascular calibre in both the cephalic and median cubital veins. The promotion of water consumption to improve venepuncture success is not supported.


Asunto(s)
Cateterismo Periférico/métodos , Calor , Estado de Hidratación del Organismo/fisiología , Venas/anatomía & histología , Venas/fisiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
6.
Children (Basel) ; 11(8)2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39201850

RESUMEN

BACKGROUND: Developmental Dysplasia of the Hip (DDH) describes a spectrum of abnormalities that impact the normal function of the joint. These abnormalities are detectable during infancy using physical assessment, universal ultrasound, or a combination of both. In Australia, child health nurses predominantly screen for this disease using physical assessment. The aim of this study was to determine if child health nurses can accurately screen for DDH using physical assessment. METHODS: This Australian study estimated the accuracy and utility of child health nurses using physical assessment to screen for DDH by comparing it to a handheld ultrasound device. RESULTS: This study (N = 44) concluded that using a point prevalence study design, child health nurses in Australia are unable to accurately assess for DDH in infants using physical assessment; overall, clinicians had 50.5% sensitivity (95% CI, 15.7 to 84.3), a specificity of 75.0% (95% CI, 57.8 to 87.9), and 71.3% accuracy (95% CI, 55.6 to 83.9). CONCLUSION: This study suggests that child health nurses cannot screen for DDH using physical assessment. Understanding education, experience and what assessments are used suggests that the utility of nurses performing DDH screening requires further investigation.

7.
Australas J Ultrasound Med ; 26(1): 34-45, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36960132

RESUMEN

Introduction/Purpose: Many guidelines have been utilised to diagnose polycystic ovarian syndrome (PCOS). The most recent are the International Evidence Based Guideline for the Assessment and Management of Polycystic Ovary Syndrome 2018 (2018 IEBG). This study aimed to assess the awareness, knowledge, and attitudes of Australasian sonographers' regarding these guidelines. Methods: An online cross-sectional survey was disseminated to sonographers. Qualitative and quantitative questions were asked around awareness, knowledge, and attitudes towards the 2018 IEBG. Statistical and thematic analyses of the results were performed. Results: Ninety responses were included in the final analysis. Fifty-two percent (52.2%) of participants were aware of the 2018 IEBG but only 31.1% used it in their workplaces. Fifty-eight percent (57.9%) of participants correctly identified the sonographic features that suggest PCOS, and 3.5% correctly identified all minimum recommended inclusions for reporting a gynaecological ultrasound for PCOS. Prior to being supplied the 2018 IEBG, 15.8% of participants correctly answered clinical scenario-based knowledge questions, which increased to 29.4% correctly after being supplied the guideline; however, this difference was not statistically significant. There were no statistically significant associations between demographics and knowledge of the 2018 IEBG. Discussion: Several areas of confusion surrounding wording and interpretation of the 2018 IEBG were highlighted. Consideration should be given to barriers of implementation and strategies to overcome these. Conclusion: More education surrounding the sonographic diagnosis of PCOS and the 2018 IEBG is needed. Scanning protocols used amongst sonographers varied, suggesting that inconsistency in sonographic diagnosis may exist. Future reviews of the 2018 IEBG should focus on reducing ambiguity in wording, which may be responsible for some of the varied interpretation of these guidelines.

8.
J Med Radiat Sci ; 70(3): 229-238, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37029950

RESUMEN

INTRODUCTION: Linking individual competencies to entrustable professional tasks provides a holistic view of Sonography graduate work readiness. The Australian Sonographers Accreditation Registry (ASAR) publishes a set of entrustable professional activities (EPAs) as part of its Standards for Accreditation of Sonography Courses. EPAs are distinct ultrasound examinations grouped within six critical practice units. This study reports on industry perspectives of current EPAs and their classification for graduates completing general sonography courses in Australia. The article also examines the value of EPAs and links their function to the assessment of graduate competency. METHODS: An online survey tool elicited stakeholder feedback on graduate EPAs across six critical practice units and the potential for including a new Paediatric unit. From an original sample size of 655, 309 responded to questions about general sonography courses. RESULTS: A majority (55.3%) recommended no changes to the existing EPA list, and 44.7% recommended amending the list. From respondents that recommended changes (138/309), all current EPAs received >80% agreement to be retained; in addition, nine new examinations received >70% agreement for inclusion at the graduate level. Whilst 42.7% (132/309) supported the current ASAR model requiring competency in five out of six critical practice units, 45.6% (141/309) recommended increasing it to all six. There was limited support, 11.7% (36/309), to reduce this number. Responding to the potential to add a new Paediatric specific critical practice unit, 61.8% (181/293) recommended its inclusion. CONCLUSIONS: The findings demonstrate that the current list of EPAs aligns with industry expectations. In contrast, there are divergent views on the modelling and grouping of critical practice units. The article's critical analysis of the results and implications provides stakeholders with a practical approach to clinical teaching and EPA assessment, and helps to inform any review of accreditation standards.


Asunto(s)
Competencia Clínica , Educación de Postgrado en Medicina , Niño , Humanos , Educación Basada en Competencias/métodos , Australia , Encuestas y Cuestionarios
9.
Ultrasound Med Biol ; 49(6): 1375-1384, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36941181

RESUMEN

Point-of-care ultrasound (PoCUS) technology is evolving rapidly and is being adopted by many health professionals in their clinical practice. Ultrasound is a complex skill requiring dedicated training. Appropriate integration of ultrasound education into medical, surgical, nursing and allied health professions is a current challenge worldwide. There are patient safety implications for use of ultrasound without adequate training and frameworks. The purpose of the review was to overview the status of PoCUS education in Australasia; investigate what is being taught and learned about ultrasound across the health professions; and identify potential gaps. The review was limited to postgraduate and qualified health professionals with established or emerging clinical use for PoCUS. A scoping review methodology was used to include literature in peer-reviewed articles, policies, guidelines, position statements, curricula and online material relating to ultrasound education. One hundred thirty-six documents were included. The literature revealed heterogeneity in ultrasound teaching and learning across the health professions. Several health professions lacked any defined scopes of practice, policies or curricula. Significant investment in resourcing ultrasound education is required to address the current needs in Australia and New Zealand.


Asunto(s)
Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Humanos , Ultrasonografía/métodos , Curriculum , Australasia
10.
J Vasc Access ; : 11297298231194100, 2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37622472

RESUMEN

BACKGROUND: Haemodialysis requires a permanent vascular access and relies on cannulation with two large bore needles. Point Of Care Ultrasound (POCUS) is a tool that may assist nursing staff with visualising cannula placement and prevent miscannulation. This can be particularly useful in regional hospitals with limited access to vascular access specialists. AIMS: To examine the impact of POCUS provision and education for nursing staff on confidence in cannulation and to understand the patient experience at three regional hospital haemodialysis units in South Australia. METHODS: A POCUS machine and dedicated nursing education were provided at each of the three sites. A pre-test post-test model was used to assess the individual nurses perceived competency before and after the delivery of a series of online ultrasound education modules and face to face training. Patient reported outcome measures (PROMs) were collected to understand the use of POCUS from the client perspective. RESULTS: There was a shift towards 'agree' or 'strongly agree' for all nursing surveys in regard to perceived competency (n = 15). This was statistically significant (p ⩽ 0.05) for all questions other than question 1 'I am confident in my ability to physically assess vascular access' (p = 0.06). The patients that completed the PROMs (n = 17) overall supported the ease and use of POCUS for haemodialysis cannulation and felt that it contributed to the nursing staff competency in cannulation. CONCLUSION: POCUS has the potential to be a valuable tool in regional haemodialysis units to support vascular access cannulation and potentially avoid metropolitan transfer due to cannulation difficulties. The non-significant change post intervention for question 1 likely reflects the haemodialysis nurses inherent pre-existing capacity to assess vascular access without the use of POCUS using the standard process of visual inspection, the use of a stethoscope and palpation ('look, listen and feel').

11.
BMJ Open ; 13(6): e071203, 2023 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-37385740

RESUMEN

There is a growing need for interventions to improve well-being in healthcare workers, particularly since the onset of COVID-19. OBJECTIVES: To synthesise evidence since 2015 on the impact of interventions designed to address well-being and burnout in physicians, nurses and allied healthcare professionals. DESIGN: Systematic literature review. DATA SOURCES: Medline, Embase, Emcare, CINAHL, PsycInfo and Google Scholar were searched in May-October 2022. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Studies that primarily investigated burnout and/or well-being and reported quantifiable preintervention and postintervention outcomes using validated well-being measures were included. DATA EXTRACTION AND SYNTHESIS: Full-text articles in English were independently screened and quality assessed by two researchers using the Medical Education Research Study Quality Instrument. Results were synthesised and presented in both quantitative and narrative formats. Meta-analysis was not possible due to variations in study designs and outcomes. RESULTS: A total of 1663 articles were screened for eligibility, with 33 meeting inclusion criterium. Thirty studies used individually focused interventions, while three were organisationally focused. Thirty-one studies used secondary level interventions (managed stress in individuals) and two were primary level (eliminated stress causes). Mindfulness-based practices were adopted in 20 studies; the remainder used meditation, yoga and acupuncture. Other interventions promoted a positive mindset (gratitude journaling, choirs, coaching) while organisational interventions centred on workload reduction, job crafting and peer networks. Effective outcomes were reported in 29 studies, with significant improvements in well-being, work engagement, quality of life and resilience, and reductions in burnout, perceived stress, anxiety and depression. CONCLUSION: The review found that interventions benefitted healthcare workers by increasing well-being, engagement and resilience, and reducing burnout. It is noted that the outcomes of numerous studies were impacted by design limitations that is, no control/waitlist control, and/or no post intervention follow-up. Suggestions are made for future research.


Asunto(s)
COVID-19 , Enfermeras y Enfermeros , Médicos , Humanos , Calidad de Vida , Personal de Salud , Lugar de Trabajo , Agotamiento Psicológico , Atención a la Salud
12.
J Med Imaging Radiat Oncol ; 67(3): 267-276, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35897127

RESUMEN

INTRODUCTION: This study aimed to assess the accuracy of transvaginal ultrasound (TVUS) for the mapping of endometriosis before surgery when performed by sonographers in an outpatient women's imaging centre. METHODS: A prospective longitudinal cohort study was performed. The study group comprised of 201 women who underwent a comprehensive TVUS assessment, performed by a sonographer. Laparoscopy was performed as the reference standard. Complete TVUS and surgical data were available for 53 women who were included in the final analysis. RESULTS: Endometriosis was confirmed at a surgery in 50/53 (94.3%) participants, with 25/53 (47.2%) having deep endometriosis (DE) nodules and/or endometriomas present. TVUS for mapping of DE had an overall sensitivity of 84.0%, specificity of 89.3%, PPV of 87.5%, NPV of 86.2%, LR+ of 7.85, LR- of 0.18, and accuracy of 86.8% (P < 0.001). Ovarian immobility had poor sensitivity for detecting localised superficial endometriosis, DE, adhesions, and/or endometriomas (Left = 61.9% and right = 13.3%) but high specificities (left = 87.5% and right = 94.7%). Site-specific tenderness had low sensitivities and moderate specificities for the same. All soft markers of endometriosis failed to reach statistical significance except for left ovarian immobility (P = <0.001). CONCLUSION: Sonographers well experienced in obstetric and gynaecological imaging, working in an outpatient women's imaging setting can accurately map DE; however, the performance of soft markers for detection of SE was poor.


Asunto(s)
Endometriosis , Femenino , Humanos , Endometriosis/diagnóstico por imagen , Endometriosis/cirugía , Estudios Prospectivos , Estudios Longitudinales , Pacientes Ambulatorios , Sensibilidad y Especificidad , Ultrasonografía/métodos
13.
J Gastrointest Surg ; 26(11): 2249-2254, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36008652

RESUMEN

INTRODUCTION: A very low-calorie diet (VLCD) or low-calorie diet (LCD) is often used prior to laparoscopic surgery to optimize access to the hiatus. Much debate exists in the literature regarding the required duration for a VLCD or LCD, and how to evaluate the presence of a fatty liver. The aim of our study was to determine the optimal amount of time on an LCD to achieve maximal liver volume reduction, and to assess the accuracy of the InBody 230® vs. bedside ultrasonography vs. magnetic resonance imaging (MRI) in the measurement of liver volume. METHODS: Seventeen consecutive patients undergoing laparoscopic anti-reflux surgery were recruited into the study. Each patient underwent body composition analysis with the InBody® 230, liver ultrasound, and liver MRI. Patients then began an LCD with a weekly ultrasound assessment until the day before surgery when they underwent repeat body composition analysis, liver ultrasound, and MRI. RESULTS: The mean age was 54 years (range 21, 74). Maximal liver volume loss was noted within 3 weeks for 88% of participants, with 47% achieving their maximal liver volume reduction after the first week of an LCD. The mean reduction in liver volume was 16%, 18.6%, and 19% for MRI, ultrasound, and body composition analysis, respectively. CONCLUSION: Close to 90% of patients require 3 weeks or less on an LCD to achieve maximal liver volume loss prior to laparoscopic anti-reflux surgery. Body composition analysis and bedside ultrasonography were both as accurate as the gold standard MRI in the assessment of liver volume.


Asunto(s)
Restricción Calórica , Procedimientos Quirúrgicos del Sistema Digestivo , Hígado Graso , Hígado , Humanos , Composición Corporal , Restricción Calórica/métodos , Laparoscopía , Hígado/diagnóstico por imagen , Pérdida de Peso , Estudios Prospectivos , Estudios de Casos y Controles , Factores de Tiempo , Tamaño de los Órganos , Hígado Graso/diagnóstico por imagen , Hígado Graso/dietoterapia , Ultrasonografía , Imagen por Resonancia Magnética , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Periodo Preoperatorio , Procedimientos Quirúrgicos del Sistema Digestivo/métodos
14.
J Child Health Care ; : 13674935221095647, 2022 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-35670703

RESUMEN

Developmental hip dysplasia is an abnormality of the hip joint which is associated with an unstable or dislocatable hip. During infancy, hips should be screened to determine whether they are stable, unstable or dislocated. In Australia, this screening is often performed by nurses using physical assessment. Physical examination includes a number of assessments which seek to identify underlying abnormalities in hip joint anatomy and function. This scoping review outlines the physical assessments used by nurses in the screening and surveillance of developmental hip dysplasia. A review of the literature identified 15 (N = 15; 100%) sources of evidence, which included original research articles (n = 6; 40%), expert opinion pieces (n = 2; 13.3%) and practice guidelines (n = 7; 46.7%). There were 18 physical assessments identified as being used by nurses in the screening process for developmental hip dysplasia. However, it is apparent that high quality research is required to examine the timing, specificity and sensitivity of the physical assessments identified.

15.
Australas J Ultrasound Med ; 25(1): 20-27, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35251899

RESUMEN

INTRODUCTION: This study aimed to determine the additional time needed to perform an endometriosis transvaginal ultrasound (eTVUS) compared to routine transvaginal ultrasound (rTVUS). METHODS: A retrospective case-control study was performed. The study group included 199 eTVUS performed between September 2019 and September 2020. The control group comprised 105 consecutive rTVUS studies performed in the same time period. The time stamps on the ultrasound images of all cases in both groups were reviewed to determine the time taken to perform each study. Mean, median, minimum and maximum scan times for both groups were calculated as was percentage difference between scan times. A two-tailed, unpaired t-test of the normalised data and a Mann-Whitney U test assessing time difference of scans between two groups were performed with P value <0.05 considered statistically significant. RESULTS: Performing eTVUS took significantly longer than rTVUS with increases in the mean (8.4 vs 13.8 min, 64%), median (7 vs 12 min, 71%), minimum (4 vs 7 min, 75%) and maximum (19 vs 42 min, 121%) scan times. The Mann-Whitney U test indicated a statistically significant difference in the median scan times (5.0, CI 4.0-6.0), P < 0.001. An independent t-test of the normalised data revealed a significantly larger mean scan time for eTVUS than rTVUS, Mean = 9.05 95%CI [13.17-4.94], t(302) = 4.327, P < 0.001. R 2 = 0.583. CONCLUSION: Endometriosis transvaginal ultrasound added an average 5.4 min to rTVUS, which is statistically significant. For ultrasound departments wanting to offer this technique, doubling the scan time allocated to perform a transvaginal ultrasound (TVUS) is suggested.

16.
Sonography ; 8(3): 90-99, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34226862

RESUMEN

Introduction: COVID-19 has seen a series of lockdowns and suspension on non-urgent elective surgeries. Subsequently, there was a drop in the number of diagnostic imaging services billed in April, May, 2020. A survey was undertaken from March to June 2020 to determine the initial impact of COVID-19 on Australasian Sonographers. This article, the first in a 3-part series presents and discusses the results of this survey pertaining to changes in the number of scans performed, and changes in the working hours of sonographers. The remaining two articles in this series address other initial COVID-19 impacts on Australasian Sonographers. Methods: An online survey was conducted containing questions regarding changes to work hours and examination numbers. Results: 444 participants answered the survey. Seventy eight percent of sonographers reported a decrease in the number of examinations being performed in their department A decrease in work hours was reported by 68% of sonographers with almost a quarter of these reporting that they had lost all their hours. A higher percentage of work hours changes were seenin private practices. Many reductions in work hours were reported to be voluntary. Conclusion: Scan numbers in ultrasound departments were affected by COVID-19, as were sonographers' work hours.

17.
Sonography ; 8(3): 100-108, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34540561

RESUMEN

INTRODUCTION: COVID-19 brought with it the requirement for healthcare workers to limit community transmission of the virus as much as possible by limiting patient contact and wearing Personal Protective Equipment (PPE). This study aimed to capture the initial adaptations to sonographic examination protocols within ultrasound departments and sonographer access to PPE. METHODS: An online survey was used to gather data on sonographer reflections of sonographic examination protocol changes seen in their departments and access to PPE between the 11th of March 2020 and the 14th of June 2020. RESULTS: To reduce the time sonographers spent with the patients and hence reduce the risk of exposure to COVID-19, sonographers reported adjustments to sonographic examination protocols including their duration and scheduling. Access to PPE was reported as poor. CONCLUSION: Numerous sonographic examination protocol changes were observed within ultrasound departments in Australasia in the initial response to COVID-19. Access to PPE was varied along with sonographer feelings around the impact of these changes.

18.
Sonography ; 8(3): 109-115, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34540562

RESUMEN

INTRODUCTION: The wellbeing of front-line healthcare workers can be impacted during a pandemic. This paper reports the initial impact on the wellbeing of COVID-19 on Australasian sonographers. METHODS: An online qualitative and quantitative survey was conducted between March and June 2020 to explore the wellbeing of Australasian sonographers in the early stages of the COVID-19 pandemic. RESULTS: Whilst most sonographers felt supported at work (300/379), those working in public hospitals felt more so than those in private practice. Sonographers in private practice felt more as though their job was at risk and were more likely to consider an alternate source of income. Sonographers felt they were working on the front line and many felt anxious about themselves (74%) or family (78%) contracting COVID-19 due to their employment. Forty-one percent of sonographers felt more isolated than normal, with younger age groups (18-34 years) feeling less like they had enough hobbies or selfcare activities to get them through. Twelve percent of sonographers reported never, or rarely, coping with the juggle of work and home life. CONCLUSION: The initial impact of the COVID-19 pandemic on the wellbeing of sonographers is evident. Longitudinal data will enable wellbeing to be tracked over time.

19.
BMJ Open ; 11(7): e045895, 2021 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-34226216

RESUMEN

OBJECTIVES: Determine the effect of the catheter to vein ratio (CVR) on rates of symptomatic thrombosis in individuals with a peripherally inserted central catheter (PICC) and identify the optimal CVR cut-off point according to diagnostic group. DESIGN: Retrospective cohort study. SETTING: 4 tertiary hospitals in Australia and New Zealand. PARTICIPANTS: Adults who had undergone PICC insertion. PRIMARY OUTCOME MEASURE: Symptomatic thrombus of the limb in which the PICC was inserted. RESULTS: 2438 PICC insertions were included with 39 cases of thrombosis (1.6%; 95% CI 1.14% to 2.19%). Receiver operator characteristic analysis was unable to be performed to determine the optimal CVR overall or according to diagnosis. The association between risk of thrombosis and CVR cut-offs commonly used in clinical practice were analysed. A 45% cut-off (≤45% versus ≥46%) was predictive of thrombosis, with those with a higher ratio having more than twice the risk (relative risk 2.30; 95% CI 1.202 to 4.383; p=0.01). This pattern continued when only those with malignancy were included in the analysis, those with cancer had twice the risk of thrombosis with a CVR greater than 45%. Whereas the 33% CVR cut-off was not associated with statistically significant results overall or in those with malignancy. Neither the 33% or 45% CVR cut-off produced statistically significant results in those with infection or other non-malignant conditions. CONCLUSIONS: Adherence to CVR cut-offs are an important component of PICC insertion clinical decision making to reduce the risk of thrombosis. These results suggest that in individuals with cancer, the use of a CVR ≤45% should be considered to minimise risk of thrombosis. Further research is needed to determine the risk of thrombosis according to malignancy type and the optimal CVR for those with a non-malignant diagnosis.


Asunto(s)
Cateterismo Venoso Central , Cateterismo Periférico , Trombosis Venosa Profunda de la Extremidad Superior , Adulto , Australia , Cateterismo Venoso Central/efectos adversos , Cateterismo Periférico/efectos adversos , Catéteres , Humanos , Nueva Zelanda , Estudios Retrospectivos , Factores de Riesgo
20.
J Vasc Access ; 22(5): 726-732, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32912057

RESUMEN

BACKGROUND: Arteriovenous fistula (AVF) management for haemodialysis (HD) is one of the most challenging aspects of clinical care. A successful cannulation outcome when an AVF or arteriovenous graft (AVG) is used for the first time can be influenced by many factors, including access maturity, staff skill, and patient factors. This study examined AVF/AVG outcomes at initiation of HD across two major metropolitan public hospitals. METHODS: Electronic medical records were reviewed to collect data retrospectively for a cohort of all newly commencing ESRD HD starts during 2018 to identify cannulation outcomes in the first 6 weeks. RESULTS: Of the 117 patients included, AVG use was low (5%). Twenty-four percent of patients required a surgical intervention to salvage a poorly functioning AVF prior to commencing HD. About 32.5% of the cohort had an uneventful start with all successful cannulations. For the remainder of the cohort the number of treatments with unsuccessful cannulation ranged from 1 to 4 or more. About 36% required a surgical intervention for a poorly functioning AVF after commencing HD. Commencing HD with a CVC is associated with a lower likelihood of subsequent successful cannulation (p < 0.001). CONCLUSION: Even in experienced centres, a subset of patients experienced complicated cannulation in the first 6 weeks of HD. Several areas of improvement could be considered for these patients; timely referral for access creation, post-operative surveillance to ensure AVF maturation inclusive of duplex ultrasonography, gentle induction using small gauge needles and low blood flows, and consideration of a single needle HD initiation pathway.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Fallo Renal Crónico , Derivación Arteriovenosa Quirúrgica/efectos adversos , Cateterismo , Humanos , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia , Diálisis Renal , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA