Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Int Orthop ; 41(8): 1655-1661, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27909754

RESUMEN

INTRODUCTION: Displaced unstable distal third fractures of the humeral diaphysis are treated surgically through open reduction and internal fixation. Conventionally, surgeons prefer using long plates for secure fixation; however, we performed short plate dual plating for robust fixation that required a smaller incision and less dissection through an anterior approach. In this study, we report the results of dual plating of fractures of the humeral shaft, with radiographic evidence and clinical analysis. METHODS: This retrospective study included 29 patients with distal third diaphyseal fractures of the humerus. There were 18 men and 11 women, with an average age of 43 years, and a mean follow-up period of 21.2 months. We investigated the type of fracture, plate length, number of fixed screws, and fracture union. Range of motion, Disabilities of Arm, Shoulder, and Hand (DASH) score, and complications during follow-up were analyzed for clinical results. RESULTS: All fractures were classified according to AO classification. We used 4.5-mm narrow locking compression plates (LCP) and 3.5-mm LCP reconstruction plates. Fracture union was achieved in all cases during the follow-up. All patients recovered favourable elbow range of motion at final follow-up. At the final follow-up, average DASH score was 10.0, and no patient showed postoperative complications. CONCLUSIONS: Satisfactory radiographic evidence and clinical results suggest that dual plating for distal diaphyseal humeral fractures may be considered a surgical option, with the advantages of strong fixation, less invasion of soft tissue, and early rehabilitation.


Asunto(s)
Placas Óseas , Diáfisis/cirugía , Fracturas del Húmero/cirugía , Adolescente , Adulto , Anciano , Diáfisis/diagnóstico por imagen , Diáfisis/lesiones , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/cirugía , Femenino , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Fracturas del Húmero/diagnóstico por imagen , Húmero/diagnóstico por imagen , Húmero/lesiones , Húmero/cirugía , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Estudios Retrospectivos , Adulto Joven , Lesiones de Codo
2.
Medicine (Baltimore) ; 98(28): e14847, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31305388

RESUMEN

RATIONALE: Atlantoaxial transarticular screw fixation has been an effective and appealing method for inducing fusion of the C1-C2 complex. This technique is usually performed with Gallie fusion. In performing Gallie fusion using sublaminar wiring, a major concern is the risk of dural tear associated with passing sublaminar wires through the epidural space. We present the first report on symptomatic symptomatic subdural hygroma (SDH) due to transarticular screw fixation with posterior wiring. PATIENTS CONCERNS: A 50-year-old man had sustained dens fracture 20 years ago and presented with severe neck pain following a recent traffic accident. The images showed atlantoaxial instability due to nonunion of the dens fracture and the patient underwent transarticular screw fixation with posterior sublaminar wiring using Gallie technique. When the U-shaped wire was passed under the arch of C1 from inferior to superior, a dural tear and cerebrospinal fluid (CSF) leak occurred. The site of dural tear was repaired by direct application of sutures. The patient was discharged in good condition. Fifteen day after surgery, the patient was readmitted with a history of a progressive headache associated with vomiting and vertigo. DIAGNONSIS: Brain CT and MRI showed bilateral posterior fossa and a right-sided supratentorial SDH. INTERVENTIONS: The patient underwent right occipital burr hole and evacuation of posterior fossa SDH due to deteriorating neurological status. OUTCOMES: The patient's condition gradually improved after the operation and became asymptomatic at 3-year follow-up. LESSONS: Posterior fossa and supratentorial SDH could occur resulting from any intraoperative dural tear and CSF leakage during posterior cervical spinal surgery. Symptomatic SDH after posterior cervical spinal surgery should be cautiously assessed and treated. LEVEL OF EVIDENCE: 5.


Asunto(s)
Articulación Atlantoaxoidea/cirugía , Inestabilidad de la Articulación/cirugía , Complicaciones Posoperatorias , Fusión Vertebral , Efusión Subdural/etiología , Articulación Atlantoaxoidea/diagnóstico por imagen , Tornillos Óseos , Hilos Ortopédicos , Diagnóstico Diferencial , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/cirugía , Efusión Subdural/diagnóstico por imagen , Efusión Subdural/cirugía
3.
Orthop Traumatol Surg Res ; 105(7): 1407-1412, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31542310

RESUMEN

BACKGROUND: Two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) have been increasingly used in various intra-articular fractures including pilon fracture. However, no study has investigated intraobserver and interobserver reliabilities of pilon fracture classification using 3D CT images. HYPOTHESIS: (1) Intraobserver and interobserver agreements of fracture classifications and treatment recommendations will improve by using 2D CT images compared to using plain radiographs only; (2) agreements will improve by adding 3D CT images compared to adding 2D CT images; and (3) agreements of orthopedic residents rather than specialists will be influenced more by imaging modality. MATERIALS AND METHODS: Ten orthopedic specialists and 10 residents completed a survey to classify the fractures according to the Rüedi-Allgöwer and AO/OTA classifications and to select treatment options using 25 pilon fracture images. The survey was conducted using plain radiographs, with 2D and 3D CT images introduced 3 and 6weeks later, respectively. Kappa coefficients were calculated to determine reliabilities. RESULTS: Intraobserver reliabilities for fracture classifications in specialists significantly improved by using 2D images compared to using plain radiographs only. Addition of 3D CT did not significantly improve intraobserver reliabilities compared to those with 2D CT. Use of 2D CT images significantly improved overall interobserver agreement of both classifications, with the improvement being greater for residents. Use of 3D CT images did not improve the interobserver reliability of both classifications. Overall interobserver reliabilities for treatment recommendations did not significantly differ according to the imaging modality. However, interobserver agreement among residents significantly improved from slight agreement using radiographs only to fair agreement using 2D CT images. DISCUSSION: Intraobserver and interobserver reliabilities of pilon fracture classification and treatment recommendations did not improve between using 3D and 2D CT. Using 2D CT images improved the intraobserver and interobserver reliabilities of the fracture classifications in specialists and the interobserver reliabilities of the fracture classifications and the treatment recommendations in residents. LEVEL OF EVIDENCE: IV, case control study.


Asunto(s)
Fracturas de Tobillo/diagnóstico , Fijación de Fractura/métodos , Imagenología Tridimensional/métodos , Fracturas Intraarticulares/diagnóstico , Fracturas de la Tibia/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Fracturas de Tobillo/clasificación , Fracturas de Tobillo/cirugía , Estudios de Casos y Controles , Humanos , Fracturas Intraarticulares/clasificación , Fracturas Intraarticulares/cirugía , Curva ROC , Reproducibilidad de los Resultados , Fracturas de la Tibia/clasificación , Fracturas de la Tibia/cirugía
4.
Hip Pelvis ; 30(4): 210-218, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30534539

RESUMEN

PURPOSE: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the Bencox® hip stem-the first Korean-developed hip prosthesis. MATERIALS AND METHODS: A consecutive series of 1,000 hip arthroplasties using the Bencox® hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84). Of these 1,000 cases, patients with a minimum follow-up of at least 1 year (n=616) were retrospectively analyzed for radiographic and clinical outcomes (i.e., Harris hip score). The stability of the prosthesis was evaluated by examining subsidence. RESULTS: During the follow-up period (mean follow-up period of 54.8 months), there were 2 cases requiring revision of the femoral stem-both were caused by periprosthetic fractures and neither involved stem loosening. The mean Harris hip score during follow-up was 95.5. Bone ongrowth occurred in 95% of patients; no cases of subsidence or aseptic loosening of the stem were detected, and no cases of postoperative complications such as ceramic breakage were observed. CONCLUSION: Clinical and radiographic evaluations of hip arthroplasty using the Bencox® hip stem revealed excellent outcomes with an average of 54.8 month follow-up in a consecutive series of 1,000 cases.

5.
J Bone Metab ; 25(1): 59-62, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29564307

RESUMEN

BACKGROUND: We determined the prevalence of sarcopenia according to fracture site and evaluated the associated risk factors in female patients with osteoporotic fractures. METHODS: A total of 108 patients aged 50 years or older with an osteoporotic fracture (hip, spine, or wrist) were enrolled in this retrospective observational study. A diagnosis of sarcopenia was confirmed using whole-body densitometry for skeletal muscle mass measurement. Logistic regression analysis was used to analyze the risk factors for sarcopenia. RESULTS: Of 108 female patients treated for osteoporotic fractures between January 2016 and June 2017, sarcopenia was diagnosed in 39 (36.1%). Of these, 41.5% (17/41) had hip fractures, 35% (14/40) had spine fractures, and 29.6% (8/27) had distal radius fractures. Body mass index (BMI; P=0.036) and prevalence of chronic kidney disease (CKD; P=0.046) and rheumatoid arthritis (P=0.051) were significantly different between the groups. In multivariable analysis, BMI (odds ratio [OR], 0.76; 95% confidence interval [CI], 0.55-1.05, P=0.098) and CKD (OR 2.51; 95% CI, 0.38-16.2; P=0.233) were associated with an increased risk of sarcopenia; however, this was not statistically significant. CONCLUSIONS: This study evaluated the prevalence of sarcopenia according to the fracture site and identified associated risk factors in patients with osteoporotic fractures. A longterm, observational study with a larger population is needed to validate our results.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA