RESUMEN
BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).
Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Diseño de Prótesis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Femenino , Corazón Auxiliar/efectos adversos , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación/estadística & datos numéricos , Accidente Cerebrovascular/etiologíaRESUMEN
BACKGROUND: Heart failure disproportionately affects Black patients. Whether differences among race influence outcomes in advanced heart failure with use of a fully magnetically levitated continuous-flow left ventricular assist device remains uncertain. METHODS: We included 515 IDE (Investigational Device Exemption) clinical trial patients and 500 Continued Access Protocol patients implanted with the HeartMate 3 left ventricular assist device in the MOMENTUM 3 study (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3). Outcomes were compared between Black and White left ventricular assist device recipients for the primary end point of survival free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years, overall survival, adverse events, 6-minute walk distance, and quality of life scores. RESULTS: Of 1015 HeartMate 3 patients, 675 were self-identified as White and 285 as Black individuals. The Black patient cohort was younger, more obese and with a history of hypertension, and more nonischemic cause of heart failure, relative to the White patient group. Black and White patients did not experience a difference in the primary end point (81.1% versus 77.9%; hazard ratio, 1.08 [95% CI, 0.76-1.54], P=0.6568). Black patients were at higher risk of adverse events (calculated as events per 100 patient-years), including bleeding (75.4 versus 63.5; P<0.0001), stroke (9.5 versus 7.2; P=0.0183), and hypertension (10.1 versus 3.2; P<0.0001). The 6-minute walk distance was not different at baseline and 6 months between the groups, however, the absolute change from baseline was greater for White patients (median: +183.0 [interquartile range, 42.0-335.3] versus +163.8 [interquartile range, 42.3-315.0] meters, P=0.01). The absolute quality of life measurement (EuroQoL group, 5-dimension, 5-level instrument visual analog scale) at baseline and 6 months was better in the Black patient group, but relative improvement from baseline to 6 months was greater in White patients (median: +20.0 [interquartile range, 5.0-40.0] versus +25.0 [interquartile range, 10.0-45.0]; P=0.0298). CONCLUSIONS: Although the survival free of disabling stroke or reoperation to replace/remove a malfunctioning device at 2 years with the HM 3 left ventricular assist device did not differ by race, Black HeartMate 3 patients experienced a higher morbidity burden and smaller gains in functional capacity and quality of life when compared with White patients. These findings require efforts designed to better understand and overcome these gaps through systematic identification and tackling of putative factors. Registration: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT02224755 and NCT02892955.
Asunto(s)
Ensayos Clínicos como Asunto , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Calidad de Vida , Reoperación/efectos adversos , Accidente Cerebrovascular/terapiaRESUMEN
OBJECTIVES: The AVOID-HF (Aquapheresis versus Intravenous Diuretics and Hospitalization for Heart Failure) trial tested the hypothesis that patients hospitalized for HF treated with adjustable ultrafiltration (AUF) would have a longer time to first HF event within 90 days after hospital discharge than those receiving adjustable intravenous loop diuretics (ALD). BACKGROUND: Congestion in hospitalized heart failure (HF) patients portends unfavorable outcomes. METHODS: The AVOID-HF trial, designed as a multicenter, 1-to-1 randomized study of 810 hospitalized HF patients, was terminated unilaterally and prematurely by the sponsor (Baxter Healthcare, Deerfield, Illinois) after enrollment of 224 patients (27.5%). Aquadex FlexFlow System (Baxter Healthcare) was used for AUF. A Clinical Events Committee, blinded to the randomized treatment, adjudicated whether 90-day events were due to HF. RESULTS: A total of 110 patients were randomized to AUF and 114 to ALD. Baseline characteristics were similar. Estimated days to first HF event for the AUF and ALD group were, respectively, 62 and 34 (p = 0.106). At 30 days, compared with the ALD group, the AUF group had fewer HF and cardiovascular events. Renal function changes were similar. More AUF patients experienced an adverse effect of special interest (p = 0.018) and a serious study product-related adverse event (p = 0.026). The 90-day mortality was similar. CONCLUSIONS: Compared with the ALD group, the AUF group trended toward a longer time to first HF event within 90 days and fewer HF and cardiovascular events. More patients in the AUF group experienced special interest or serious product-related adverse event. Due to the trial's untimely termination, additional AUF investigation is warranted.
Asunto(s)
Insuficiencia Cardíaca/terapia , Hospitalización/tendencias , Inhibidores del Simportador de Cloruro Sódico y Cloruro Potásico/administración & dosificación , Ultrafiltración/métodos , Anciano , Relación Dosis-Respuesta a Droga , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Humanos , Infusiones Intravenosas , Masculino , Estudios Prospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
OBJECTIVES: We sought to assess the relationship between survival, peak exercise oxygen consumption (VO(2)), and heart failure survival score (HFSS) in the current era of heart failure (HF) therapy. BACKGROUND: Based on predicted survival, HF patients with peak VO(2) <14 ml/min/kg or medium- to high-risk HFSS are currently considered eligible for heart transplantation. However, these criteria were developed before the widespread use of beta-blockers, spironolactone, and defibrillators-interventions known to improve the survival of HF patients. METHODS: Peak VO(2) and HFSS were assessed in 320 patients followed from 1994 to 1997 (past era) and in 187 patients followed from 1999 to 2001 (current era). Outcomes were compared between these two groups of patients and those who underwent heart transplantation from 1993 to 2000. RESULTS: Survival in the past era was 78% at one year and 67% at two years, as compared with 88% and 79%, respectively, in the current era (both p < 0.01). One-year event-free survival (without urgent transplantation or left ventricular assist device) was improved in the current era, regardless of initial peak VO(2): 64% vs. 48% for peak VO(2) <10 ml/min/kg (p = 0.09), 81% vs. 70% for 10 to 14 ml/min/kg (p = 0.05), and 93% vs. 82% for >14 ml/min/kg (p = 0.04). Of the patients with peak VO(2) of 10 to 14 ml/min/kg, 55% had low-risk HFSS and exhibited 88% one-year event-free survival. One-year survival after transplantation was 88%, which is similar to the 85% rate reported by the United Network for Organ Sharing for 1999 to 2000. CONCLUSIONS: Survival for HF patients in the current era has improved significantly, necessitating re-evaluation of the listing criteria for heart transplantation.
Asunto(s)
Insuficiencia Cardíaca/cirugía , Trasplante de Corazón , Selección de Paciente , Algoritmos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Tasa de SupervivenciaRESUMEN
BACKGROUND: Pre-transplant fixed pulmonary hypertension is associated with higher post-transplant mortality. In this study, we assessed the significance of pre-transplant reversible pulmonary hypertension in patients undergoing cardiac transplantation. METHODS: Overall, we studied 182 patients with baseline normal pulmonary pressures or reversible pulmonary hypertension, defined as a decrease in pulmonary vascular resistance (PVR) to < or =2.5 Wood units (WU), who underwent cardiac transplantation. Multiple recipient and donor characteristics were assessed to identify independent predictors of mortality. RESULTS: The average duration of follow-up was 42 +/- 28 months. Forty patients (22%) died during the follow-up period. Baseline hemodynamics for alive vs dead patients were as follows: pulmonary artery systolic (PAS) 42 +/- 15 vs 52 +/- 15 mm Hg; PA diastolic 21 +/- 9 vs 25 +/- 9 mm Hg; PA mean 28 +/- 11 vs 35 +/- 10 mm Hg; transpulmonary gradient (TPG) 9 +/- 4 vs 11 +/- 7 mm Hg (all p < 0.05); total pulmonary resistance 7.7 +/- 4.8 vs 8.8 +/- 3.2 WU (p = 0.08); and PVR 2.3 +/- 1.5 vs 2.9 +/- 1.6 WU (p = 0.06). In an unadjusted analysis, patients with PAS >50 mm Hg had a higher risk of death (odds ratio [OR] 5.96, 95% confidence interval [CI] 1.46 to 19.84 as compared with PAS < or =30 mm Hg). There was no significant difference in survival among patients with baseline PVR <2.5, 2.5 to 4.0 or >4.0 WU, but patients with TPG > or =16 had a higher risk of mortality (OR 4.93, 95% CI 1.84 to 13.17). PAS pressure was an independent predictor of mortality (OR 1.04, 95% CI 1.02 to 1.06). Recipient body mass index, history of sternotomy; and donor ischemic time were the other independent predictors of mortality. CONCLUSION: Pre-transplant pulmonary hypertension, even when reversible to a PVR of < or =2.5 WU, is associated with a higher mortality post-transplant.
Asunto(s)
Trasplante de Corazón/mortalidad , Hipertensión Pulmonar/complicaciones , Adulto , Femenino , Estudios de Seguimiento , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/epidemiología , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/cirugía , Selección de Paciente , Valor Predictivo de las Pruebas , Pronóstico , Factores de Riesgo , Estadística como Asunto , Análisis de Supervivencia , Resultado del TratamientoRESUMEN
BACKGROUND: Health-related quality of life and functional performance are important outcome measures following heart transplantation. This study investigates the impact of pre-transplant functional performance and post-transplant rejection episodes, obesity and osteopenia on post-transplant health-related quality of life and functional performance. METHODS: Functional performance and health-related quality of life were measured in 70 adult heart transplant recipients. A composite health-related quality of life outcome measure was computed via principal component analysis. Iterative, multiple regression-based path analysis was used to develop an integrated model of variables that affect post-transplant functional performance and health-related quality of life. RESULTS: Functional performance, as measured by the Karnofsky scale, improved markedly during the first 6 months post-transplant and was then sustained for up to 3 years. Rejection Grade > or =2 was negatively associated with health-related quality of life, measured by Short Form-36 and reversed Psychosocial Adjustment to Illness Scale scores. Patients with osteopenia had lower Short Form-36 physical scores and obese patients had lower functional performance. Path analysis demonstrated a negative direct effect of obesity (beta = - 0.28, p < 0.05) on post-transplant functional performance. Post-transplant functional performance had a positive direct effect on the health-related quality of life composite score (beta = 0.48, p < 0.001), and prior rejection episodes grade > or =2 had a negative direct effect on this measure (beta = -0.29, p < 0.05). Either directly or through effects mediated by functional performance, moderate-to-severe rejection, obesity and osteopenia negatively impact health-related quality of life. These findings indicate that efforts should be made to devise immunosuppressive regimens that reduce the incidence of acute rejection, weight gain and osteopenia after heart transplantation.
Asunto(s)
Trasplante de Corazón , Complicaciones Posoperatorias/epidemiología , Calidad de Vida , Enfermedades Óseas Metabólicas/epidemiología , Comorbilidad , Femenino , Estudios de Seguimiento , Rechazo de Injerto/epidemiología , Trasplante de Corazón/mortalidad , Trasplante de Corazón/psicología , Humanos , Inmunosupresores/uso terapéutico , Estado de Ejecución de Karnofsky , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Obesidad/epidemiología , Evaluación de Resultado en la Atención de Salud , Análisis de Regresión , Estudios Retrospectivos , Factores de TiempoRESUMEN
Repeat sternotomy for left ventricular assist device insertion may result in injury to the right heart or patent coronary grafts, complicating intraoperative and postoperative management. In 4 critically ill patients, left thoracotomy was used as an alternative to repeat sternotomy. Anastomosis of the outflow conduit to the descending thoracic aorta provided satisfactory hemodynamic support.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Corazón Auxiliar , Toracotomía , Humanos , ReoperaciónRESUMEN
BACKGROUND: Although beta-blockers were well-tolerated by heart failure (HF) patients in clinical trials, tolerability of these drugs in a general population of HF patients is not well-described. METHODS: We studied a total of 308 encounters with beta-blockers therapy in 268 ambulatory HF patients. Side effects and frequency and predictors of discontinuation of therapy were studied. Independent predictors of discontinuation were assessed. RESULTS: Weight gain (59%), fatigue (56%), dizziness (41%), and dyspnea (29%) were the most common side effects. Fifty-one patients (19%) were discontinued on therapy with any 1 particular beta-blocker. Fatigue (30%) and hypotension (28%) were the most common reasons for discontinuation. Forty (78%) of these were given a trial with a different beta-blocker. Of these, 22 (55%) attempts with a different beta-blocker were tolerated. Thus the overall absolute discontinuation rate was only 7% for patients who were given a trial with different beta-blockers or 11% for the entire study population. Independent predictors of discontinuation of therapy included advanced symptoms, nonischemic etiology, history of pulmonary disease, and higher diuretic doses. CONCLUSION: Side effects with beta-blockers in a general population of HF patients are common; however, with changes in medical management, most patients can tolerate them eventually. In case of intolerance to one kind, a trial with a different beta-blocker is indicated.