Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 51(4): 978-990, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38049658

RESUMEN

PURPOSE: A same-day PET imaging agent capable of measuring PD-L1 status in tumors is an important tool for optimizing PD-1 and PD-L1 treatments. Herein we describe the discovery and evaluation of a novel, fluorine-18 labeled macrocyclic peptide-based PET ligand for imaging PD-L1. METHODS: [18F]BMS-986229 was synthesized via copper mediated click-chemistry to yield a PD-L1 PET ligand with picomolar affinity and was tested as an in-vivo tool for assessing PD-L1 expression. RESULTS: Autoradiography showed an 8:1 binding ratio in L2987 (PD-L1 (+)) vs. HT-29 (PD-L1 (-)) tumor tissues, with >90% specific binding. Specific radioligand binding (>90%) was observed in human non-small-cell lung cancer (NSCLC) and cynomolgus monkey spleen tissues. Images of PD-L1 (+) tissues in primates were characterized by high signal-to-noise, with low background signal in non-expressing tissues. PET imaging enabled clear visualization of PD-L1 expression in a murine model in vivo, with 5-fold higher uptake in L2987 (PD-L1 (+)) than in control HT-29 (PD-L1 (-)) tumors. Moreover, this imaging agent was used to measure target engagement of PD-L1 inhibitors (peptide or mAb), in PD-L1 (+) tumors as high as 97%. CONCLUSION: A novel 18F-labeled macrocyclic peptide radioligand was developed for PET imaging of PD-L1 expressing tissues that demonstrated several advantages within a nonhuman primate model when compared directly to adnectin- or mAb-based ligands. Clinical studies are currently evaluating [18F]BMS-986229 to measure PD-L1 expression in tumors.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Dominio de Fibronectina del Tipo III , Radioisótopos de Flúor , Neoplasias Pulmonares , Proteínas Recombinantes , Humanos , Ratones , Animales , Antígeno B7-H1/metabolismo , Ligandos , Macaca fascicularis/metabolismo , Tomografía de Emisión de Positrones/métodos , Péptidos/química
2.
Bioorg Med Chem ; 25(20): 5407-5414, 2017 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-28803798

RESUMEN

Cancer immunotherapy, unlike traditional cytotoxic chemotherapeutic treatments, engages the immune system to identify cancer cells and stimulate immune responses. The Programmed Death-1 (PD-1) protein is an immunoinhibitory receptor expressed by activated cytotoxic T-lymphocytes (CTL) that seek out and destroy cancer cells. Multiple cancer types express and upregulate the Programmed Death-Ligand 1 (PD-L1) and 2 (PD-L2) which bind to PD-1 as an immune escape mechanism. Nivolumab is a fully human IgG4 anti-PD-1 monoclonal antibody (mAb) approved for treatment of multiple cancer types. This study reports the preparation and in vivo evaluation of 89Zr labeled nivolumab in healthy non-human primates (NHP) as a preliminary study of biodistribution and clearance. The radiochemical and in vivo stabilities of the 89Zr complex were shown to be acceptable for imaging. Three naïve NHPs were intravenously injected with tracer only or tracer co-injected with nivolumab followed by co-registered by positron emission tomography (PET) and magnetic resonance imaging (MRI), acquired for eight days following injection. Image-derived standardized uptake values (SUV) were quantified by region of interest (ROI) analysis. Radioactivity in the spleen was significantly reduced by addition of excess nivolumab compared to the tracer only study at all imaging time points. Liver uptake of the radiotracer was consistent as a clearance organ with minimal signal from other tissues: lung, muscle, brain, heart, and kidney. The results indicate specific biodistribution to the spleen, which can be blocked by co-administration of excess nivolumab. Distribution to other organs is consistent with elimination pathways of antibodies, with primary clearance through the liver.


Asunto(s)
Anticuerpos Monoclonales/farmacocinética , Tomografía de Emisión de Positrones , Animales , Anticuerpos Monoclonales/administración & dosificación , Anticuerpos Monoclonales/química , Relación Dosis-Respuesta a Droga , Macaca fascicularis , Imagen por Resonancia Magnética , Masculino , Estructura Molecular , Nivolumab , Relación Estructura-Actividad , Distribución Tisular
3.
Mol Imaging Biol ; 26(2): 301-309, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38123744

RESUMEN

PURPOSE: In cancer immunotherapy, the blockade of the interaction between programmed death-1 and its ligand (PD-1:PD-L1) has proven to be one of the most promising strategies. However, as mechanisms of resistance to PD-1/PD-L1 inhibition include variability in tumor cell PD-L1 expression in addition to standard tumor biopsy PD-L1 immunohistochemistry (IHC), a comprehensive and quantitative approach for measuring PD-L1 expression is required. Herein, we report the development and characterization of an 18F-PD-L1-binding macrocyclic peptide as a PET tracer for the comprehensive evaluation of tumor PD-L1 expression in cancer patients. PROCEDURES: 18F-BMS-986229 was characterized for PD-L1 expression assessment by autoradiography or PET imaging. 18F-BMS-986229 was utilized to evaluate tumor PD-L1 target engagement in competition with a macrocyclic peptide inhibitor of PD-L1 (BMS-986189) over a range of doses using PET imaging. A whole-body radiation dosimetry study of 18F-BMS-986229 in healthy non-human primates (NHPs) was performed. RESULTS: In vitro autoradiography showed an 8:1 binding ratio in L2987(PD-L1 +) vs. HT-29 (PD-L1-) tumors, more than 90% of which could be blocked with 1 nM of BMS-986189. Ex vivo autoradiography showed that 18F-BMS-986229 detection was penetrant over a series of sections spanning the entire L2987 tumor. In vivo PET imaging in mice demonstrated a 5:1 tracer uptake ratio (at 90-100 min after tracer administration) in L2987 vs. HT-29 tumors and demonstrated 83%-93% specific binding of BMS-986189 within those dose ranges. In a healthy NHP dosimetry study, the resultant whole-body effective dose was 0.025 mSv/MBq. CONCLUSION: 18F-BMS-986229 has been preclinically characterized and exhibits high target specificity, low background uptake, and a short blood half-life supportive of same day imaging in the clinic. As the PET tracer, 18F-BMS-986229 shows promise in the quantification of PD-L1 expression, and its use in monitoring longitudinal changes in patients may provide insights into PD-1:PD-L1 immuno-therapy treatment outcomes.


Asunto(s)
Antígeno B7-H1 , Neoplasias , Humanos , Animales , Ratones , Antígeno B7-H1/metabolismo , Receptor de Muerte Celular Programada 1 , Tomografía de Emisión de Positrones/métodos , Radiometría , Péptidos
4.
J Psychopharmacol ; 32(2): 146-155, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29378483

RESUMEN

Major depressive disorder is a leading cause of disability globally. Improvements in the efficacy of antidepressant therapy are needed as a high proportion (>40%) of individuals with major depressive disorder fail to respond adequately to current treatments. The non-selective N-methyl-D-aspartate receptor channel blocker, (±)-ketamine, has been reported to produce a rapid and long-lasting antidepressant response in treatment-resistant major depressive disorder patients, which provides a unique opportunity for investigation of mechanisms that mediate its therapeutic effect. Efforts have also focused on the development of selective N-methyl-D-aspartate receptor subtype 2B antagonists which may retain antidepressant activity but have lower potential for dissociative/psychotomimetic effects. In the present study, we examined the central nervous system effects of acute, intravenous administration of (±)-ketamine or the N-methyl-D-aspartate receptor subtype 2B antagonist, traxoprodil, in awake rats using pharmacological magnetic resonance imaging. The study contained five treatment groups: vehicle, 3 mg/kg (±)-ketamine, and three doses of traxoprodil (0.3 mg/kg, 5 mg/kg, and 15 mg/kg). Non-linear model fitting was performed on the temporal hemodynamic pharmacological magnetic resonance imaging data to generate brain activation maps as well as regional responses based on blood oxygen level dependent signal changes for group analysis. Traxoprodil at 5 mg/kg and 15 mg/kg produced a dose-dependent pharmacological magnetic resonance imaging signal in rat forebrain regions with both doses achieving >80% N-methyl-D-aspartate receptor subtype 2B occupancy determined by ex vivo [3H]Ro 25-6981 binding. The middle dose of traxoprodil (5 mg/kg) generated region-specific activations in medial prefrontal cortex, ventral orbital cortex, and anterior cingulate cortex whereas the high dose (15 mg/kg) produced a widespread pharmacological magnetic resonance imaging response in both cortical and subcortical brain regions which was similar to that produced by (±)-ketamine (3 mg/kg, intravenous).


Asunto(s)
Trastorno Depresivo Mayor/tratamiento farmacológico , Ketamina/farmacología , Imagen por Resonancia Magnética/métodos , Piperidinas/farmacología , Animales , Antidepresivos/administración & dosificación , Antidepresivos/farmacología , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Trastorno Depresivo Mayor/fisiopatología , Relación Dosis-Respuesta a Droga , Antagonistas de Aminoácidos Excitadores/administración & dosificación , Antagonistas de Aminoácidos Excitadores/farmacología , Ketamina/administración & dosificación , Masculino , Dinámicas no Lineales , Fenoles/farmacología , Piperidinas/administración & dosificación , Ratas , Ratas Sprague-Dawley , Receptores de N-Metil-D-Aspartato/antagonistas & inhibidores , Vigilia
5.
J Nucl Med ; 48(2): 295-303, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17268028

RESUMEN

UNLABELLED: Recent developments have established molecular imaging of mouse models with small-animal PET and bioluminescence imaging (BLI) as an important tool in cancer research. One of the disadvantages of these imaging modalities is the lack of anatomic information. We combined small-animal PET and BLI technology with small-animal CT to obtain fusion images with both molecular and anatomic information. METHODS: We used small-animal PET/CT and BLI to detect xenografts of different cell lines and metastases of a melanoma cell line (A375M-3F) that had been transduced with a lentiviral vector containing a trimodality imaging reporter gene encoding a fusion protein with Renilla luciferase, monomeric red fluorescent protein, and a mutant herpes simplex virus type 1 thymidine kinase. RESULTS: Validation studies in mouse xenograft models showed a good coregistration of images from both PET and CT. Melanoma metastases were detected by 18F-FDG PET, 9-[4-(18)F-fluoro-3-(hydroxymethyl)butyl]guanine (18F-FHBG) PET, CT, and BLI and confirmed by ex vivo assays of Renilla luciferase and mutant thymidine kinase expression. 18F-FHBG PET/CT allowed detection and localization of lesions that were not seen on CT because of poor contrast resolution and were not seen on 18F-FDG PET because of higher background uptake relative to 18F-FHBG. CONCLUSION: The combination of 18F-FHBG PET, small-animal CT, and BLI allows a sensitive and improved quantification of tumor burden in mice. This technique is potentially useful for the study of the biologic determinants of metastasis and for the evaluation of novel cancer treatments.


Asunto(s)
Trasplante de Neoplasias/diagnóstico por imagen , Trasplante de Neoplasias/patología , Animales , Línea Celular Tumoral , Fluorodesoxiglucosa F18 , Guanina/análogos & derivados , Herpesvirus Humano 1/enzimología , Procesamiento de Imagen Asistido por Computador , Luciferasas , Luminiscencia , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Masculino , Melanoma/diagnóstico por imagen , Melanoma/patología , Ratones , Ratones Desnudos , Ratones SCID , Metástasis de la Neoplasia/patología , Tomografía de Emisión de Positrones , Radiofármacos , Timidina Quinasa/metabolismo , Tomografía Computarizada por Rayos X , Trasplante Heterólogo
6.
Med Phys ; 33(1): 216-24, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16485428

RESUMEN

The purpose of this work was to calculate radiation dose and its organ distribution in a realistic mouse phantom from micro-computed tomography (microCT) imaging protocols. CT dose was calculated using GATE and a voxelized, realistic phantom. The x-ray photon energy spectra used in simulations were precalculated with GATE and validated against previously published data. The number of photons required per simulated experiments was determined by direct exposure measurements. Simulated experiments were performed for three types of beams and two types of mouse beds. Dose-volume histograms and dose percentiles were calculated for each organ. For a typical microCT screening examination with a reconstruction voxel size of 200 microm, the average whole body dose varied from 80 mGy (at 80 kVp) to 160 mGy (at 50 kVp), showing a strong dependence on beam hardness. The average dose to the bone marrow is close to the soft tissue average. However, due to dose nonuniformity and higher radiation sensitivity, 5% of the marrow would receive an effective dose about four times higher than the average. If CT is performed longitudinally, a significant radiation dose can be given. The total absorbed radiation dose is a function of milliamperes-second, beam hardness, and desired image quality (resolution, noise and contrast). To reduce dose, it would be advisable to use the hardest beam possible while maintaining an acceptable contrast in the image.


Asunto(s)
Modelos Biológicos , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/veterinaria , Imagen de Cuerpo Entero/métodos , Imagen de Cuerpo Entero/veterinaria , Animales , Carga Corporal (Radioterapia) , Simulación por Computador , Ratones , Modelos Estadísticos , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Efectividad Biológica Relativa
7.
Phys Med Biol ; 51(2): 379-90, 2006 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-16394345

RESUMEN

Many research institutions have a full suite of preclinical tomographic scanners to answer biomedical questions in vivo. Routine multi-modality imaging requires robust registration of images generated by various tomographs. We have implemented a hardware registration method for preclinical imaging that is similar to that used in the combined positron emission tomography (PET)/computed tomography (CT) scanners in the clinic. We designed an imaging chamber which can be rigidly and reproducibly mounted on separate microPET and microCT scanners. We have also designed a three-dimensional grid phantom with 1288 lines that is used to generate the spatial transformation matrix from software registration using a 15-parameter perspective model. The imaging chamber works in combination with the registration phantom synergistically to achieve the image registration goal. We verified that the average registration error between two imaging modalities is 0.335 mm using an in vivo mouse bone scan. This paper also estimates the impact of image misalignment on PET quantitation using attenuation corrections generated from misregistered images. Our technique is expected to produce PET quantitation errors of less than 5%. The methods presented are robust and appropriate for routine use in high throughput animal imaging facilities.


Asunto(s)
Huesos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Programas Informáticos , Animales , Ratones , Tomografía de Emisión de Positrones/métodos
8.
J Nucl Med ; 46(3): 455-63, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15750159

RESUMEN

UNLABELLED: The microPET Focus is the latest generation microPET system dedicated to high-resolution animal imaging and incorporates several changes to enhance its performance. This study evaluated the basic performance of the scanner and compared it with the Primate (P4) and Rodent (R4) models. METHODS: The system consists of 168 lutetium oxyorthosilicate (LSO) detectors arranged in 4 contiguous rings, with a 25.8-cm diameter and a 7.6-cm axial length. Each detector consists of a 12 x 12 LSO crystal array of 1.51 x 1.51 x 10.00 mm3 elements. The scintillation light is transmitted to position-sensitive photomultiplier tubes via optical fiber bundles. The system was evaluated for its energy and spatial resolutions, sensitivity, and noise equivalent counting rate. Phantoms and animals of varying sizes were scanned to evaluate its imaging capability. RESULTS: The energy resolution averages 18.5% for the entire system. Reconstructed image resolution is 1.3-mm full width at half maximum (FWHM) at the center of field of view (CFOV) and remains under 2 mm FWHM within the central 5-cm-diameter FOV in all 3 dimensions. The absolute sensitivity of the system is 3.4% at the CFOV for an energy window of 250-750 keV and a timing window of 10 ns. The noise equivalent counting-rate performance reaches 645 kcps for a mouse-size phantom using 250- to 750-keV and 6-ns settings. Emission images of a micro-Derenzo phantom demonstrate the improvement in image resolution compared with previous models. Animal studies exhibit the capability of the system in studying disease models using mouse, rat, and nonhuman primates. CONCLUSION: The Focus has significantly improved performance over the previous models in all areas evaluated. This system represents the state-of-the-art scintillator-based animal PET scanner currently available and is expected to advance the potential of small animal PET.


Asunto(s)
Encéfalo/diagnóstico por imagen , Análisis de Falla de Equipo , Corazón/diagnóstico por imagen , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/veterinaria , Animales , Diseño de Equipo , Macaca , Ratones , Fantasmas de Imagen , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Evaluación de la Tecnología Biomédica
9.
Phys Med Biol ; 50(8): 1837-50, 2005 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-15815099

RESUMEN

Attenuation correction is one of the important corrections required for quantitative positron emission tomography (PET). This work will compare the quantitative accuracy of attenuation correction using a simple global scale factor with traditional transmission-based methods acquired either with a small animal PET or a small animal x-ray computed tomography (CT) scanner. Two phantoms (one mouse-sized and one rat-sized) and two animal subjects (one mouse and one rat) were scanned in CTI Concorde Microsystem's microPET Focus for emission and transmission data and in ImTek's MicroCAT II for transmission data. PET emission image values were calibrated against a scintillation well counter. Results indicate that the scale factor method of attenuation correction places the average measured activity concentration about the expected value, without correcting for the cupping artefact from attenuation. Noise analysis in the phantom studies with the PET-based method shows that noise in the transmission data increases the noise in the corrected emission data. The CT-based method was accurate and delivered low-noise images suitable for both PET data correction and PET tracer localization.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/veterinaria , Técnica de Sustracción , Animales , Artefactos , Ratones , Ratones Endogámicos C3H , Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA