Am J Case Rep ; 19: 325-328, 2018 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-29559613

RESUMEN

BACKGROUND Kirschner wires are often used to perform osteosynthesis. Migration through tissue of these wires is a rare but well-known occurrence. CASE REPORT A 65-year-old female presented with light intensity pain complaints in the upper left chest area; personal history included left clavicle fracture 20 years ago that was treated surgically with fixation using a K-wire. Chest radiography showed the presence of metallic foreign body in the left pulmonary apex. An exploratory axillary thoracotomy was performed, and the foreign body was extracted by a pneumotomy. CONCLUSIONS To obtain satisfactory results with a K-wire, some peculiarities in their application should be respected. The time from orthopedic surgery of the collarbone to migration into the chest of the metal rod used can vary from one day to nearly 20 years. Although the migration mechanism remains unclear, it is likely that it involves shoulder movements, breathing movements, negative intrathoracic pressure, gravitational force, or local bone resorption. Caution should be exercised when orthopedic pins and wires are used for the fixation of fractures and dislocations of the shoulder girdle. If there is migration of the wire, it should be removed immediately to avoid sudden and fatal complications.


Asunto(s)
Hilos Ortopédicos/efectos adversos , Clavícula/lesiones , Migración de Cuerpo Extraño/diagnóstico , Fijación Interna de Fracturas/efectos adversos , Fracturas Óseas/cirugía , Pulmón , Anciano , Clavícula/diagnóstico por imagen , Remoción de Dispositivos , Femenino , Migración de Cuerpo Extraño/cirugía , Fracturas Óseas/diagnóstico , Humanos , Neumonectomía/métodos , Radiografía , Reoperación
2.
J Med Case Rep ; 10(1): 261, 2016 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-27658582

RESUMEN

BACKGROUND: We herein present a case in which a Toxoplasma cyst was found in a transbronchial biopsy specimen from an immunocompetent patient with negative serology for the parasite. CASE PRESENTATION: An 18-year-old Brazilian man presented with a 1-week history of dyspnea and fever and was diagnosed with right lower lobe pneumonia. He began inpatient treatment with intravenous antibiotics. During treatment, a bronchoscopy with bronchoalveolar lavage and transbronchial biopsy was performed. Anatomopathological examination of the transbronchial biopsy showed a small fragment of lung parenchyma with discrete septal thickening and a rounded structure, suggestive of a pseudocyst containing Toxoplasma gondii bradyzoites. However, serological tests were negative for immunoglobulin G and immunoglobulin M. CONCLUSIONS: Bronchoscopy is a minimally invasive, effective diagnostic and therapeutic method. Despite the fact that the Toxoplasma pseudocyst in the present case was not the cause of the patient's comorbidities, bronchoscopy with transbronchial biopsy allowed for an incidental diagnosis of a Toxoplasma pseudocyst with minimal invasiveness.