Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Radiology ; 291(2): 340-348, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30888934

RESUMEN

Background Patient preference is pivotal for widespread adoption of tests in clinical practice. Patient preferences for invasive versus other noninvasive tests for coronary artery disease are not known. Purpose To compare patient acceptance and preferences for noninvasive and invasive cardiac imaging in North and South America, Asia, and Europe. Materials and Methods This was a prospective 16-center trial in 381 study participants undergoing coronary CT angiography with stress perfusion, SPECT, and invasive coronary angiography (ICA). Patient preferences were collected by using a previously validated questionnaire translated into eight languages. Responses were converted to ordinal scales and were modeled with generalized linear mixed models. Results In patients in whom at least one test was associated with pain, CT and SPECT showed reduced median pain levels, reported on 0-100 visual analog scales, from 20 for ICA (interquartile range [IQR], 4-50) to 6 for CT (IQR, 0-27.5) and 5 for SPECT (IQR, 0-25) (P < .001). Patients from Asia reported significantly more pain than patients from other continents for ICA (median, 25; IQR, 10-50; P = .01), CT (median, 10; IQR, 0-30; P = .02), and SPECT (median, 7; IQR, 0-28; P = .03). Satisfaction with preparation differed by continent and test (P = .01), with patients from Asia reporting generally lower ratings. Patients from North America had greater percentages of "very high" or "high" satisfaction than patients from other continents for ICA (96% vs 82%, respectively; P < .001) and SPECT (95% vs 79%, respectively; P = .04) but not for CT (89% vs 86%, respectively; P = .70). Among all patients, CT was preferred by 54% of patients, compared with 18% for SPECT and 28% for ICA (P < .001). Conclusion For cardiac imaging, patients generally favored CT angiography with stress perfusion, while study participants from Asia generally reported lowest satisfaction. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Woodard and Nguyen in this issue.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Prioridad del Paciente/estadística & datos numéricos , Anciano , Angiografía por Tomografía Computarizada/efectos adversos , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/psicología , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Angiografía Coronaria/psicología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dolor Asociado a Procedimientos Médicos , Estudios Prospectivos
2.
Radiology ; 284(1): 55-65, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28290782

RESUMEN

Purpose To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial perfusion imaging. Materials and Methods This study was approved by all institutional review boards, and written informed consent was obtained. Between November 2009 and July 2011, 381 participants clinically referred for ICA and aged 45-85 years were enrolled in the Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-Detector Row Computed Tomography (CORE320) prospective multicenter diagnostic study. All images were analyzed in blinded independent core laboratories, and a panel of physicians adjudicated all adverse events. MACE was defined as revascularization (>30 days after index ICA), myocardial infarction, or cardiac death; hospitalization for chest pain or congestive heart failure; or arrhythmia. Late MACE was defined similarly, except for patients who underwent revascularization within the first 182 days after ICA, who were excluded. Comparisons of 2-year survival (time to MACE) used standard Kaplan-Meier curves and restricted mean survival times bootstrapped with 2000 replicates. Results An MACE (49 revascularizations, five myocardial infarctions, one cardiac death, nine hospitalizations for chest pain or congestive heart failure, and one arrhythmia) occurred in 51 of 379 patients (13.5%). The 2-year MACE-free rates for combined CT angiography and CT perfusion findings were 94% negative for coronary artery disease (CAD) versus 82% positive for CAD and were similar to combined ICA and single photon emission CT findings (93% negative for CAD vs 77% positive for CAD, P < .001 for both). Event-free rates for CT angiography and CT perfusion versus ICA and single photon emission CT for either positive or negative results were not significantly different for MACE or late MACE (P > .05 for all). The area under the receiver operating characteristic curve (AUC) for combined CT angiography and CT perfusion (AUC = 68; 95% confidence interval [CI]: 62, 75) was similar (P = .36) to that for combined ICA and single photon emission CT (AUC = 71; 95% CI: 65, 79) in the identification of MACE at 2-year follow-up. Conclusion Combined CT angiography and CT perfusion enables similar prediction of 2-year MACE, late MACE, and event-free survival similar to that enabled by ICA and single photon emission CT. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Imagen de Perfusión Miocárdica , Tomografía Computarizada de Emisión de Fotón Único , Anciano , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Sensibilidad y Especificidad , Encuestas y Cuestionarios , Análisis de Supervivencia
3.
AJR Am J Roentgenol ; 204(1): W27-36, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25539270

RESUMEN

OBJECTIVE. The purpose of this study was to comprehensively study estimated radiation doses for subjects included in the main analysis of the Combined Non-invasive Coronary Angiography and Myocardial Perfusion Imaging Using 320 Detector Computed Tomography (CORE320) study ( ClinicalTrials.gov identifier NCT00934037), a clinical trial comparing combined CT angiography (CTA) and perfusion CT with the reference standard catheter angiography plus myocardial perfusion SPECT. SUBJECTS AND METHODS. Prospectively acquired data on 381 CORE320 subjects were analyzed in four groups of testing related to radiation exposure. Radiation dose estimates were compared between modalities for combined CTA and perfusion CT with respect to covariates known to influence radiation exposure and for the main clinical outcomes defined by the trial. The final analysis assessed variations in radiation dose with respect to several factors inherent to the trial. RESULTS. The mean radiation dose estimate for the combined CTA and perfusion CT protocol (8.63 mSv) was significantly (p < 0.0001 for both) less than the average dose delivered from SPECT (10.48 mSv) and the average dose from diagnostic catheter angiography (11.63 mSv). There was no significant difference in estimated CTA-perfusion CT radiation dose for subjects who had false-positive or false-negative results in the CORE320 main analyses in a comparison with subjects for whom the CTA-perfusion CT findings were in accordance with the reference standard SPECT plus catheter angiographic findings. CONCLUSION. Radiation dose estimates from CORE320 support clinical implementation of a combined CT protocol for assessing coronary anatomy and myocardial perfusion.


Asunto(s)
Absorción de Radiación , Angiografía Coronaria/estadística & datos numéricos , Estenosis Coronaria/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Recuento Corporal Total/estadística & datos numéricos , Anciano , Femenino , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Eur Heart J ; 35(17): 1120-30, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24255127

RESUMEN

AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA-SPECT/MPI and ICA alone was 38 and 59%, respectively. The patient-based diagnostic accuracy defined by the area under the receiver operating characteristic curve (AUC) of integrated CTA-CTP for detecting or excluding flow-limiting CAD was 0.87 [95% confidence interval (CI): 0.84-0.91]. In patients without prior myocardial infarction, the AUC was 0.90 (95% CI: 0.87-0.94) and in patients without prior CAD the AUC for combined CTA-CTP was 0.93 (95% CI: 0.89-0.97). For the combination of a CTA stenosis ≥50% stenosis and a CTP perfusion deficit, the sensitivity, specificity, positive predictive, and negative predicative values (95% CI) were 80% (72-86), 74% (68-80), 65% (58-72), and 86% (80-90), respectively. For flow-limiting disease defined by ICA-SPECT/MPI, the accuracy of CTA was significantly increased by the addition of CTP at both the patient and vessel levels. CONCLUSIONS: The combination of CTA and perfusion correctly identifies patients with flow limiting CAD defined as ≥50 stenosis by ICA causing a perfusion defect by SPECT/MPI.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Estenosis Coronaria/fisiopatología , Femenino , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Imagen de Perfusión Miocárdica/métodos , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad
5.
Radiology ; 272(2): 407-16, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24865312

RESUMEN

PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography. MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise or pharmacologic stress SPECT before and within 60 days of coronary angiography. Images from CT perfusion imaging, SPECT, and coronary angiography were interpreted at blinded, independent core laboratories. The primary diagnostic parameter was the area under the receiver operating characteristic curve (Az). Sensitivity and specificity were calculated with use of prespecified cutoffs. The reference standard was a stenosis of at least 50% at coronary angiography as determined with quantitative methods. RESULTS: CAD was diagnosed in 229 of the 381 patients (60%). The per-patient sensitivity and specificity for the diagnosis of CAD (stenosis ≥50%) were 88% (202 of 229 patients) and 55% (83 of 152 patients), respectively, for CT perfusion imaging and 62% (143 of 229 patients) and 67% (102 of 152 patients) for SPECT, with Az values of 0.78 (95% confidence interval: 0.74, 0.82) and 0.69 (95% confidence interval: 0.64, 0.74) (P = .001). The sensitivity of CT perfusion imaging for single- and multivessel CAD was higher than that of SPECT, with sensitivities for left main, three-vessel, two-vessel, and one-vessel disease of 92%, 92%, 89%, and 83%, respectively, for CT perfusion imaging and 75%, 79%, 68%, and 41%, respectively, for SPECT. CONCLUSION: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
6.
ScientificWorldJournal ; 2013: 731590, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24453899

RESUMEN

PURPOSE: To compare radiation dose and image quality using predefined narrow phase window versus complete phase window with dose modulation during R-R using 320-row MDCTA. METHODS: 114 patients underwent coronary CTA study using 320-row MDCT scanner. 87 patients with mean age (61 + 13 years), mean BMI (29 + 6), and mean heart rate (HR) (58 + 7 bpm) were imaged at predefined 66-80% R-R interval and then reconstructed at 75% while 27 patients with mean age (63 + 16 years), mean BMI (28 + 5), and mean HR (57 + 7 bpm) were scanned throughout the complete R-R interval with tube current modulation. The effective dose (ED) was calculated from dose length product (DLP) and conversion k (0.014 mSv/mGy/cm). Image quality was assessed using a three-point ordinal scale (1 = excellent, 2 = good, and 3 = nondiagnostic). RESULTS: Both groups were statistically similar to each other with reference of HR (P = 0.59), BMI (P = 0.17), and tube current mAs (P = 0.68). The median radiation dose was significantly higher in those scanned with complete R-R phase window versus narrow phase window (P < 0.0001). Independently of patient and scan parameters, increased phase window was associated with higher radiation dose (P < 0.001). Image quality was better among those scanned with narrow phase window versus complete phase window (P < 0.0001). CONCLUSION: Our study supports that good HR control and predefined narrow window acquisition result in lower radiation dose without compromising diagnostic image quality for coronary disease evaluation.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Arq Bras Cardiol ; 120(3): e20220183, 2023 03.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-36946854

RESUMEN

BACKGROUND: Coronary artery calcium (CAC) scanning can be performed using non-contrast computed tomography to predict cardiovascular events, but has less value for risk stratification in symptomatic patients. OBJECTIVE: To identify and validate predictors of significant coronary obstruction (SCO) in symptomatic patients without coronary artery calcification. METHODS: A total of 4,258 participants were screened from the CORE64 and CORE320 studies that enrolled patients referred for invasive angiography, and from the Quanta Registry that included patients referred for coronary computed tomography angiography (CTA). Logistic regression models evaluated associations between cardiovascular risk factors, CAC, and SCO. An algorithm to assess the risk of SCO was proposed for patients without CAC. Significance level of 5% was used in the analyses. RESULTS: Of the 509 participants of the CORE study, 117 (23%) had zero coronary calcium score; 13 (11%) patients without CAC had SCO. Zero calcium score was related to younger age, female gender, lower body mass index, no diabetes, and no dyslipidemia. Being a current smoker increased ~3.5 fold the probability of SCO and other CV risk factors were not significantly associated. Considering the clinical findings, an algorithm to further stratify zero calcium score patients was proposed and had a limited performance in the validation cohort (AUC 58; 95%CI 43, 72). CONCLUSION: A lower cardiovascular risk profile is associated with zero calcium score in a setting of high-risk patients. Smoking is the strongest predictor of SCO in patients without CAC.


FUNDAMENTO: A avaliação do Escore de Cálcio Coronariano (ECC) pode ser realizada por tomografia computadorizada sem contraste para prever eventos cardiovasculares, mas tem menor valor na estratificação de risco em pacientes sintomáticos. OBJETIVO: Identificar e validar preditores de obstrução coronariana significativa (OCS) em pacientes sintomáticos sem calcificação da artéria coronária. MÉTODOS: Um total de 4258 participantes foram rastreados dos estudos CORE64 e CORE 320, nos quais foram avaliados pacientes encaminhados para angiografia invasiva, e do Quanta Registry que incluiu pacientes encaminhados para angiotomografia. Modelos de regressão logística avaliaram associações entre fatores de risco cardiovascular, ECC e OCS. Um nível de significância de 5% foi usado nas análises. RESULTADOS: Dos 509 participantes do estudo CORE, 117 (23%) apresentaram um ECC igual a zero; 13 (11%) pacientes sem cálcio coronariano apresentaram OCS. A ausência de cálcio coronariano correlacionou-se com idade mais jovem, sexo feminino, índice de massa corporal mais baixo, ausência de diabetes, e ausência de dislipidemia. O fato de ser fumante atual aumentou em 3,5 vezes a probabilidade de OCS e outros fatores de risco cardiovasculares não apresentaram associação significativa. Considerando os achados clínicos, um algoritmo para estratificar os pacientes com ECC igual a zero foi proposto, e tiveram desempenho limitado na coorte de validação (AUC 58; IC95% 43, 72). CONCLUSÃO: Um perfil de risco cardiovascular mais baixo está associado a um ECC igual a zero em pacientes de alto risco. Tabagismo é o preditor mais forte de OCS em pacientes com ausência de cálcio coronariano.


Asunto(s)
Enfermedad de la Arteria Coronaria , Oclusión Coronaria , Calcificación Vascular , Humanos , Femenino , Calcio , Angiografía Coronaria/métodos , Valor Predictivo de las Pruebas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Corazón , Factores de Riesgo , Vasos Coronarios/diagnóstico por imagen , Calcificación Vascular/diagnóstico por imagen , Medición de Riesgo
8.
N Engl J Med ; 359(22): 2324-36, 2008 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-19038879

RESUMEN

BACKGROUND: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. METHODS: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. RESULTS: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. CONCLUSIONS: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.)


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Angina de Pecho/clasificación , Angina de Pecho/diagnóstico por imagen , Área Bajo la Curva , Angiografía Coronaria/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Método Simple Ciego , Evaluación de la Tecnología Biomédica , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos
9.
Radiology ; 261(1): 100-8, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21828192

RESUMEN

PURPOSE: To evaluate the influence of cross-sectional arc calcification on the diagnostic accuracy of computed tomography (CT) angiography compared with conventional coronary angiography for the detection of obstructive coronary artery disease (CAD). MATERIALS AND METHODS: Institutional Review Board approval and written informed consent were obtained from all centers and participants for this HIPAA-compliant study. Overall, 4511 segments from 371 symptomatic patients (279 men, 92 women; median age, 61 years [interquartile range, 53-67 years]) with clinical suspicion of CAD from the CORE-64 multicenter study were included in the analysis. Two independent blinded observers evaluated the percentage of diameter stenosis and the circumferential extent of calcium (arc calcium). The accuracy of quantitative multidetector CT angiography to depict substantial (≥ 50%) stenoses was assessed by using quantitative coronary angiography (QCA). Cross-sectional arc calcium was rated on a segment level as follows: noncalcified or mild (< 90°), moderate (90°-180°), or severe (> 180°) calcification. Univariable and multivariable logistic regression, receiver operation characteristic curve, and clustering methods were used for statistical analyses. RESULTS: A total of 1099 segments had mild calcification, 503 had moderate calcification, 338 had severe calcification, and 2571 segments were noncalcified. Calcified segments were highly associated (P < .001) with disagreement between CTA and QCA in multivariable analysis after controlling for sex, age, heart rate, and image quality. The prevalence of CAD was 5.4% in noncalcified segments, 15.0% in mildly calcified segments, 27.0% in moderately calcified segments, and 43.0% in severely calcified segments. A significant difference was found in area under the receiver operating characteristic curves (noncalcified: 0.86, mildly calcified: 0.85, moderately calcified: 0.82, severely calcified: 0.81; P < .05). CONCLUSION: In a symptomatic patient population, segment-based coronary artery calcification significantly decreased agreement between multidetector CT angiography and QCA to detect a coronary stenosis of at least 50%.


Asunto(s)
Calcinosis/diagnóstico por imagen , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
10.
AJR Am J Roentgenol ; 197(1): 163-8, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21701026

RESUMEN

OBJECTIVE: The purpose of this study was to compare radiation dose and image quality of 320- and 64-MDCT angiography using prospective gating. MATERIALS AND METHODS: One hundred seventy-four patients underwent 320-MDCT, and 95 patients underwent 64-MDCT. The scan parameters for 320-MDCT were 120 kVp, 400 mA, and gantry rotation of 350 milliseconds; the parameters for 64-MDCT were 120 kVp, 600 mA, and gantry rotation of 350 milliseconds. Effective dose (ED) was calculated from the dose-length product and a conversion factor (k = 0.014 mSv / mGy × cm). Two observers independently assessed image quality using a 3-point scale, where 3 denotes excellent quality and 1 denotes nondiagnostic quality, using a 16-segment model. Discrepancies were settled by consensus. RESULTS: The ED was significantly lower in patients undergoing 320-MDCT angiography, with a median ED of 4.4 mSv (interquartile range [IQR], 3.4-6.2 mSv), compared with 64-MDCT angiography, with a median ED of 6.2 mSv (IQR, 5.5-6.9 mSv) (p = 0.0001). In patients with a heart rate of 65 beats/min or less (92%), the median radiation dose using 320-MDCT was 4.1 mSv (IQR, 3.2-6.1 mSv), and that for 64-MDCT angiography was 6.2 mSv (IQR, 5.8-6.9 mSv) (p = 0.0001). In patients with heart rate greater than 65 beats/min (8%), the median dose was higher with 320-MDCT (8.7 mSv; IQR, 5.9-14.3 mSv) than with 64-MDCT (5.8 mSv; IQR, 5.3-6.7 mSv) (p = 0.02). Segmental image quality was significantly better for 320-MDCT (excellent or good quality, 96.66%; nondiagnostic quality, 0.1%) than for 64-MDCT angiography (excellent or good quality, 86%; nondiagnostic quality, 3.33%) (all p < 0.0001). CONCLUSION: Image quality was good for both 320- and 64-MDCT angiography. Overall radiation dose was significantly lower in 320-MDCT angiography when the heart rate was 65 beats/min or less. Every effort should be made to control heart rate to minimize radiation dose.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiometría , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación
11.
AJR Am J Roentgenol ; 196(2): 407-11, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21257894

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the relation between radiation dose reduction and volume scan length for prospectively ECG-gated 320-MDCT angiography in the diagnosis of coronary artery disease. MATERIALS AND METHODS: MDCT with prospective ECG gating was performed at one of the three volume scan lengths depending on heart length. Of 175 patients, 95 (55%; body mass index, 29 ± 5.9; mean heart rate, 59 ± 7 beats/min) underwent scanning at 160 mm; 46 (26%; body mass index, 30 ± 4.1; mean heart rate, 56 ± 5.74 beats/min) at 140 mm; and 34 (19%; body mass index, 30 ± 3.71; mean heart rate, 58 ± 3.96 beats/min) at 120 mm. RESULTS: The median radiation doses were 6.5 mSv (95% CI, 6.03-7.2 mSv) for the 95 patients who underwent scanning at a volume scan length of 160 mm, 4.33 mSv (95% CI, 4.06-6.62 mSv) for the 46 patients who underwent scanning at 140 mm, and 3.47 mSv (95% CI, 3.15-3.62 mSv) for the 34 patients who underwent scanning at 120 mm. The reduction in scan length from 160 to 140 mm represented a reduction in scan length of 12.5% and the reduction to 120 mm a reduction of 25%. The median radiation dose was reduced 33% when volume scan length was changed to 140 mm and 47% when the length was changed to 120 mm. CONCLUSION: Dose optimization remains an important concern in cardiac CT, and for 320-MDCT angiography, substantial dose reduction can be achieved by reducing volume scan length so that it is in concert with the patient's heart length.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
AJR Am J Roentgenol ; 197(4): 829-37, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21940569

RESUMEN

OBJECTIVE: Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION: We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Medios de Contraste , Prueba de Esfuerzo , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Radiofármacos , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/métodos
13.
J Cardiovasc Comput Tomogr ; 15(6): 485-491, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34024757

RESUMEN

BACKGROUND: Few data exist on long-term outcome in patients undergoing combined coronary CT angiography (CTA) and myocardial CT perfusion imaging (CTP) as well as invasive coronary angiography (ICA) and single photon emission tomography (SPECT). METHODS: At 16 centers, 381 patients were followed for major adverse cardiac events (MACE) for the CORE320 study. All patients underwent coronary CTA, CTP, and SPECT before ICA within 60 days. Prognostic performance according binary results (normal/abnormal) was assessed by 5-year major cardiovascular events (MACE) free survival and area under the receiver-operating-characteristic curve (AUC). RESULTS: Follow up beyond 2-years was available in 323 patients. MACE-free survival rate was greater among patients with normal combined CTA-CTP findings compared to ICA-SPECT: 85 vs. 80% (95% confidence interval [CI] for difference 0.1, 11.3) though event-free survival time was similar (4.54 vs. 4.37 years, 95% CI for difference: -0.03, 0.36). Abnormal results by combined CTA-CTP was associated with 3.83 years event-free survival vs. 3.66 years after abnormal combined ICA-SPECT (95% CI for difference: -0.05, 0.39). Predicting MACE by AUC also was similar: 65 vs. 65 (difference 0.1; 95% CI -4.6, 4.9). When MACE was restricted to cardiovascular death, myocardial infarction, or stroke, AUC for CTA-CTP was 71 vs. 60 by ICA-SPECT (difference 11.2; 95% CI -1.0, 19.7). CONCLUSIONS: Combined CTA-CTP evaluation yields at least equal 5-year prognostic information as combined ICA-SPECT assessment in patients presenting with suspected coronary artery disease. Noninvasive cardiac CT assessment may eliminate the need for diagnostic cardiac catheterization in many patients. CLINICAL TRIAL REGISTRATION: NCT00934037.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Tomografía Computarizada por Rayos X
15.
AJR Am J Roentgenol ; 194(1): 85-92, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20028909

RESUMEN

OBJECTIVE: Evaluations of stents by MDCT from studies performed at single centers have yielded variable results with a high proportion of unassessable stents. The purpose of this study was to evaluate the accuracy of 64-MDCT angiography (MDCTA) in identifying in-stent restenosis in a multicenter trial. MATERIALS AND METHODS: The Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography Using 64 Detectors (CORE-64) Multicenter Trial and Registry evaluated the accuracy of 64-MDCTA in assessing 405 patients referred for coronary angiography. A total of 75 stents in 52 patients were assessed: 48 of 75 stents (64%) in 36 of 52 patients (69%) could be evaluated. The prevalence of in-stent restenosis by quantitative coronary angiography (QCA) in this subgroup was 23% (17/75). Eighty percent of the stents were or=50% stenosis by QCA was 0.25 (p=0.073). Quantitative assessment failed to improve the accuracy of MDCT over qualitative assessment. CONCLUSION: The results of our study showed that 64-MDCT has poor ability to detect in-stent restenosis in small-diameter stents. Evaluability and negative predictive value were better in large-diameter stents. Thus, 64-MDCT may be appropriate for stent assessment in only selected patients.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/terapia , Oclusión de Injerto Vascular/diagnóstico por imagen , Stents , Tomografía Computarizada Espiral/métodos , Anciano , Medios de Contraste , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Yopamidol , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sistema de Registros , Análisis de Regresión , Sensibilidad y Especificidad
16.
AJR Am J Roentgenol ; 195(6): 1347-54, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21098194

RESUMEN

OBJECTIVE: The purpose of this article is to estimate the absorbed radiation dose in radiosensitive organs during coronary MDCT angiography using 320-MDCT and to determine the effects of tube voltage variation and heart rate (HR) control on absorbed radiation dose. MATERIALS AND METHODS: Semiconductor field effect transistor detectors were used to measure absorbed radiation doses for the thyroid, midbreast, breast, and midlung in an anthropomorphic phantom at 100, 120, and 135 kVp at two different HRs of 60 and 75 beats per minute (bpm) with a scan field of view of 320 mm, 400 mA, 320 × 0.5 mm detectors, and 160 mm collimator width (160 mm range). The paired Student's t test was used for data evaluation. RESULTS: At 60 bpm, absorbed radiation doses for 100, 120, and 135 kVp were 13.41 ± 3.59, 21.7 ± 4.12, and 29.28 ± 5.17 mGy, respectively, for midbreast; 11.76 ± 0.58, 18.86 ± 1.06, and 24.82 ± 1.45 mGy, respectively, for breast; 12.19 ± 2.59, 19.09 ± 3.12, and 26.48 ± 5.0 mGy, respectively, for lung; and 0.37 ± 0.14, 0.69 ± 0.14, and 0.92 ± 0.2 mGy, respectively, for thyroid. Corresponding absorbed radiation doses for 75 bpm were 38.34 ± 2.02, 59.72 ± 3.13, and 77.8 ± 3.67 mGy for midbreast; 26.2 ± 1.74, 44 ± 1.11, and 52.84 ± 4.07 mGy for breast; 38.02 ± 1.58, 58.89 ± 1.68, and 78 ± 2.93 mGy for lung; and 0.79 ± 0.233, 1.04 ± 0.18, and 2.24 ± 0.52 mGy for thyroid. Absorbed radiation dose changes were significant for all organs for both tube voltage reductions as well as for HR control from 75 to 60 bpm at all tube voltage settings (p < 0.05). The absorbed radiation doses for the calcium score protocol were 11.2 ± 1.4 mGy for midbreast, 9.12 ± 0.48 mGy for breast, 10.36 ± 1.3 mGy for lung, and 0.4 ± 0.05 mGy for thyroid. CONCLUSION: CT angiography with 320-MDCT scanners results in absorbed radiation doses in radiosensitive organs that compare favorably to those previously reported. Significant dose reductions can be achieved by tube voltage reductions and HR control.


Asunto(s)
Angiografía Coronaria/instrumentación , Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada por Rayos X/instrumentación , Mama/efectos de la radiación , Ojo/efectos de la radiación , Femenino , Corazón/efectos de la radiación , Frecuencia Cardíaca/efectos de la radiación , Humanos , Análisis de los Mínimos Cuadrados , Pulmón/efectos de la radiación , Masculino , Fantasmas de Imagen , Medición de Riesgo , Glándula Tiroides/efectos de la radiación
17.
AJR Am J Roentgenol ; 194(1): 93-102, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20028910

RESUMEN

OBJECTIVE: The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS: Two hundred ninety-one patients with a coronary artery calcification (CAC) score of or=50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS: Increasing body mass index (BMI) (odds ratio [OR]=0.89, p<0.001), increasing heart rate (OR=0.90, p<0.001), and the presence of breathing artifact (OR=4.97, p

Asunto(s)
Calcinosis/diagnóstico por imagen , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Artefactos , Índice de Masa Corporal , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Curva ROC , Interpretación de Imagen Radiográfica Asistida por Computador , Factores de Riesgo , Sensibilidad y Especificidad
18.
Int J Cardiovasc Imaging ; 36(12): 2365-2375, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32361925

RESUMEN

PURPOSE: To provide comparative prognostic information of coronary atherosclerotic plaque volume and stenosis assessment in patients with suspected coronary artery disease (CAD). METHODS: We followed 372 patients with suspected or known CAD enrolled in the CORE320 study for 2 years after baseline 320-detector row cardiac CT scanning and invasive quantitative coronary angiography (QCA). CT images were analyzed for coronary calcium scanning (CACS), semi-automatically derived total percent atheroma volume (PAV), segment stenosis score (SSS), in addition to traditional stenosis assessment (≥ 50%) by CT and QCA for (1) 30-day revascularization and (2) major adverse cardiac events (MACE). Area under the receiver operating characteristic curve (AUC) was used to compare accuracy of risk prediction. RESULTS: Sixty percent of patients had obstructive CAD by QCA with 23% undergoing 30-day revascularization and 9% experiencing MACE at 2 years. Most late events (20/32) were revascularization procedures. Prediction of 30-day revascularization was modest (AUC range 0.67-0.78) but improved after excluding patients with known CAD (AUC range 0.73-0.86, p < 0.05 for all). Similarly, prediction of MACE improved after excluding patients with known CAD (AUC range 0.58-0.73 vs. 0.63-0.77). CT metrics of atherosclerosis burden performed overall similarly but stenosis assessment was superior for predicting 30-day revascularization. CONCLUSIONS: Angiographic and coronary atherosclerotic plaque metrics perform only modestly well for predicting 30-day revascularization and 2-year MACE in high risk patients but improve after excluding patients with known CAD. Atherosclerotic plaque metrics did not yield incremental value over stenosis assessment for predicting events that predominantly consisted of revascularization procedures. CLINICAL TRIAL REGISTRATION: NCT00934037.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada Multidetector , Placa Aterosclerótica , Anciano , Investigación sobre la Eficacia Comparativa , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Progresión de la Enfermedad , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo
19.
Eur Radiol ; 19(4): 816-28, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18998142

RESUMEN

Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective "CORE-64" trial ("Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors"). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.


Asunto(s)
Angiografía Coronaria/instrumentación , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Ensayos Clínicos como Asunto , Medios de Contraste/farmacología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/anatomía & histología , Diseño de Equipo , Humanos , Relaciones Interinstitucionales , Garantía de la Calidad de Atención de Salud , Reproducibilidad de los Resultados , Proyectos de Investigación , Tamaño de la Muestra
20.
J Vasc Interv Radiol ; 20(7): 965-70, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19501528

RESUMEN

The patient characteristics, techniques used, and outcomes of 11 patients with lower urinary tract hemorrhage treated with embolotherapy are described. The authors focus on bilateral superselective embolization of the arterial supply to the bladder and techniques to embolize multiple small vessels supplying the bladder when the vascular anatomy is complicated and superselective catheterization is not possible. The immediate success rate was 100%, with three later recurrences. One procedure was complicated by asymptomatic occlusion of the posterior division of the internal iliac artery. Embolotherapy can provide at least short-term success adequate to improve quality of life for palliation with few complications.


Asunto(s)
Embolización Terapéutica/métodos , Hemorragia/terapia , Hemostáticos/administración & dosificación , Polivinilos/administración & dosificación , Enfermedades de la Vejiga Urinaria/terapia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA