Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Toxicol Ind Health ; 33(4): 351-364, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27256293

RESUMEN

There is currently no consensus on the best exposure metric(s) for expressing nanoparticle (NP) dose. Although surface area has been extensively studied for inflammatory responses, it has not been as thoroughly validated for cytotoxicity or oxidative stress effects. Since inhaled NPs deposit and interact with lung cells based on agglomerate size, we hypothesize that mass concentration combined with aerosol size distribution is suitable for NP risk assessment. The objective of this study was to evaluate different exposure metrics for inhaled 5 nm titanium dioxide aerosols composed of small (SA < 100 nm) or large (LA > 100 nm) agglomerates at 2, 7, and 20 mg/m3 on rat lung inflammatory, cytotoxicity, and oxidative stress responses. We found a significant positive correlation ( r = 0.98, p < 0.01) with the inflammatory reaction, measured by the number of neutrophils and the mass concentration when considering all six (SA + LA) aerosols. This correlation was similar ( r = 0.87) for total surface area. Regarding cytotoxicity and oxidative stress responses, measured by lactate dehydrogenase and 8-isoprostane, respectively, and mass or total surface area as an exposure metric, we observed significant positive correlations only with SA aerosols for both the mass concentration and size distribution ( r > 0.91, p < 0.01), as well as for the total surface area ( r > 0.97, p < 0.01). These data show that mass or total surface area concentrations alone are insufficient to adequately predict oxidant and cytotoxic pulmonary effects. Overall, our study indicates that considering NP size distribution along with mass or total surface area concentrations contributes to a more mechanistic discrimination of pulmonary responses to NP exposure.


Asunto(s)
Exposición por Inhalación , Pulmón/efectos de los fármacos , Nanopartículas del Metal/toxicidad , Oxidantes/toxicidad , Mucosa Respiratoria/efectos de los fármacos , Titanio/toxicidad , Pruebas de Toxicidad Aguda/métodos , Aerosoles , Animales , Biomarcadores/metabolismo , Líquido del Lavado Bronquioalveolar/química , Muerte Celular/efectos de los fármacos , Dinoprost/análogos & derivados , Dinoprost/metabolismo , Relación Dosis-Respuesta a Droga , Pulmón/inmunología , Masculino , Nanopartículas del Metal/administración & dosificación , Nanopartículas del Metal/química , Nanopartículas del Metal/ultraestructura , Infiltración Neutrófila/efectos de los fármacos , Oxidantes/administración & dosificación , Oxidantes/química , Estrés Oxidativo/efectos de los fármacos , Tamaño de la Partícula , Ratas Endogámicas F344 , Mucosa Respiratoria/inmunología , Propiedades de Superficie , Titanio/administración & dosificación , Titanio/química
3.
Inhal Toxicol ; 24(8): 528-38, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22746402

RESUMEN

CONTEXT: Titanium dioxide nanoparticles (nano-TiO(2)) and ethanol vapors are air contaminants with increasing importance. The presence of a pathological pulmonary condition, such as asthma, may increase lung susceptibility to such contaminants. OBJECTIVE: This study aimed to investigate if exposure to inhaled ethanol vapors or nano-TiO(2) can modulate the rat pulmonary inflammatory response resulting from an allergic asthmatic reaction. MATERIALS AND METHODS: Brown Norway rats were sensitized (sc) and challenged (15 min inhalation, 14 days later) with chicken egg ovalbumin (OVA). Leukocytes were counted in bronchoalveolar lavages (BAL) performed at 6, 24, 36, 48 and 72 h following the challenge and either after ethanol exposures (3000 ppm, 6 h/day, daily) or at 48 h (peak inflammation) for nano-TiO(2) exposures (9.35 mg/m(3) aerosol for 6 and 42 h after the OVA challenge). For the nano-TiO(2) exposures, plasma and BAL cytokines were measured and lung histological analyzes were performed. RESULTS: Exposure to ethanol did not significantly affect BAL leukocytes after OVA challenge. Exposure to nano-TiO(2) significantly decreased BAL leukocytes compared to OVA-challenged controls. Plasma and BAL IL-4, IL-6, and INF-γ levels were also decreased in the nano-TiO(2) group. DISCUSSION: While ethanol vapors do not modify the pulmonary inflammation in rats during an asthmatic response, a surprising protective effect for agglomerated nano-TiO(2) was observed. A putative mechanistic basis involving a decrease in the Th2 response caused by OVA is proposed. CONCLUSION: Allergic pulmonary inflammation is not up-regulated by inhalation of the pollutants ethanol and nano-TiO(2). On the contrary, nano-TiO(2) decreases lung inflammation in asthmatic rats.


Asunto(s)
Contaminantes Atmosféricos/toxicidad , Asma/complicaciones , Etanol/toxicidad , Nanopartículas/toxicidad , Neumonía/inducido químicamente , Titanio/toxicidad , Aerosoles , Animales , Asma/sangre , Asma/inmunología , Líquido del Lavado Bronquioalveolar , Citocinas/sangre , Modelos Animales de Enfermedad , Relación Dosis-Respuesta a Droga , Etanol/sangre , Femenino , Exposición por Inhalación , Pulmón/efectos de los fármacos , Pulmón/inmunología , Pulmón/patología , Masculino , Ovalbúmina/inmunología , Neumonía/complicaciones , Neumonía/inmunología , Ratas , Ratas Endogámicas BN , Volatilización
4.
J Occup Environ Hyg ; 6(11): 687-97, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19757293

RESUMEN

To examine the influence of the sampling method on beryllium (Be) exposure assessment, a study was conducted in foundries and smelters to contrast the performance of five different dust sampling devices. Six sampling surveys were conducted in four different settings, and both personal and fixed station samples were collected using the following sampling heads: IOM samplers (inhalable dust), 35-mm plastic cassettes (total dust), aluminum SKC cyclones (respirable dust), 8-stage Sierra cascade impactors, and 12-stage MOUDI impactors. In total, beryllium concentrations were determined for 66/68 inhalable dust samples, 62/62 total dust samples, 56/57 respirable dust samples, 54/64 8-stage Sierra samples, and 19/25 12-stage MOUDI samples. In the magnesium foundry and aluminum smelters, the concentrations obtained during specific tasks could exceed the actual permissible exposure limit of the province of Quebec (0.15 microg/m(3)) or of the ACGIH threshold limit value (TLV) (0.05 microg/m(3)). The median of median dust concentration ratios computed from the sampling heads at the fixed station decreased as follows: IOM (1.00) > Sierra (0.76) > 37-mm cassette (0.61) > MOUDI (0.48) > respirable (0.12). The same trends were observed with the ratios of the median of median Be concentrations at the fixed station but with a larger scattering within sampling heads as follows: IOM (1.00) > Sierra (0.69) > 37-mm cassette (0.64) > MOUDI (0.54) > respirable (0.19). The median of median ratios of dust (IOM (1.00) > Sierra (0.56) > 37-mm cassette (0.35) > respirable (0.06)) and Be (IOM (1.00) > Sierra (0.66) > 37-mm cassette (0.48) > respirable (0.11)) in dust were lower, and there was less scattering for the 37-mm cassette and SKC cyclone used during breathing zone sampling than for the same sampling heads at the fixed station. Inhalable aerosol measurements should remain the tool for estimating the risk of exposure to beryllium in these settings until a clear dose response is established for these sampling heads.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Berilio/análisis , Monitoreo del Ambiente/métodos , Residuos Industriales/análisis , Metalurgia , Aerosoles/análisis , Aluminio , Polvo/análisis , Humanos , Exposición por Inhalación/análisis , Magnesio , Exposición Profesional/análisis , Quebec
5.
Chest ; 102(2): 402-7, 1992 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-1643922

RESUMEN

STUDY OBJECTIVE: We previously described a closed-circuit system for exposure to particles in humans. This system has three components: a particle generator, an exposure chamber connected to an orofacial mask, and monitors. We describe results of challenges in 56 subjects who underwent challenges with the apparatus using occupational sensitizers in particles. SUBJECTS: Fifty-six consecutive subjects referred for the investigation of occupational asthma to occupational sensitizers in particles were included. The agents were the following: flour and grains (n = 19), cedar (n = 10), psyllium (n = 9), guar gum (n = 9), drugs (n = 3), persulfate (n = 2), and miscellaneous (n = 4). INTERVENTION: The duration of exposure was progressive and varied from one breath to a maximum of 180 min depending on the reaction. When no significant fall in FEV1 occurred after exposure with the aerosolization device, the standard approach of tipping particles from one tray to another was used. RESULTS: Twenty-nine subjects (52 percent) had a significant (greater than or equal to 20 percent) fall in FEV1 after exposure. This includes 18 subjects with isolated immediate reactions, four with dual asthmatic reactions, and two with atypical reactions. In 20/24 instances (83 percent), the percentage of fall in FEV1 did not exceed 30 percent, thus showing that dose-response curves can generally be obtained in a safe way. In all instances except one (26/27 cases), subsequent exposures using the traditional method did not result in significant falls in FEV1. CONCLUSION: This new procedure results in safe tests in terms of the percentage of changes in FEV1 during the immediate reactions and very rare false-negative challenges.


Asunto(s)
Asma/diagnóstico , Pruebas de Provocación Bronquial/instrumentación , Enfermedades Profesionales/diagnóstico , Aerosoles , Alérgenos , Asma/fisiopatología , Hiperreactividad Bronquial/diagnóstico , Pruebas de Provocación Bronquial/métodos , Relación Dosis-Respuesta Inmunológica , Polvo , Diseño de Equipo , Estudios de Evaluación como Asunto , Volumen Espiratorio Forzado/efectos de los fármacos , Humanos , Enfermedades Profesionales/fisiopatología , Factores de Tiempo
6.
Chest ; 109(6): 1631-5, 1996 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8769522

RESUMEN

Specific inhalation challenges are an important tool for confirming occupational asthma. In recent years, we have described two closed-circuit apparatuses that allow exposure to stable and controlled concentrations of particles and isocyanate gases. More recently, we developed a similar apparatus that generates chemicals in vapor form. The aim of this work is to describe its performance in the specific case of formaldehyde. This instrument is made of four parts: a generator as such, an exposure chamber, a monitor, and an automated regulatory system. This apparatus was assessed in four subjects suspected of having formaldehyde-induced asthma or alveolitis. The concentrations of formaldehyde were increased from 0.5 to 1 mg/m3 to 3 mg/m3 keeping the concentration at a value of 3 mg/m3 or less (threshold limit value). The dispersion of obtained values by comparison with the median data (6 values) was as follows: maximum value, 12 to 84%; minimum value, 20 to 58%; interquartile range, 0.13 to 0.9 mg/m3. We observed that target concentrations took a few minutes to be reached, but, once they were obtained, delivered concentrations were stable. The new vapor-delivery apparatus allows us to obtain concentrations of formaldehyde that are close to target concentrations with an acceptable dispersion of values around target concentration. Its use should be extended to other chemicals besides formaldehyde.


Asunto(s)
Pruebas de Provocación Bronquial/instrumentación , Formaldehído/administración & dosificación , Administración por Inhalación , Aerosoles , Asma/inducido químicamente , Asma/diagnóstico , Formaldehído/efectos adversos , Humanos , Enfermedades Profesionales/inducido químicamente , Enfermedades Profesionales/diagnóstico
7.
J Aerosol Med ; 13(1): 1-10, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10947318

RESUMEN

An apparatus to generate solid particles was tested for use in diagnosing occupational asthma. This equipment measures the inhaled dose of dry particles during specific inhalation challenge. It includes an aerosol generator, a cyclone type particle size selector, and an inhalation chamber to which a patient breathing at tidal volume can be connected for the test. It is fully controlled by a standard personal computer in automatic mode, acting on the flow rate and the aerosol generator to maintain the concentration at a fixed value, usually 3 mg/m3. The dose of aerosol delivered to the patient was calculated from the aerosol concentration, and the inhaled volume was calculated by integration of the corresponding signals. The coefficient of variation for this measurement was estimated to be 12%. The mass median aerodynamic diameter (MMAD) of aerosol inside the inhalation chamber was measured for three substances: lactose, wheat flour, and buckwheat flour. The MMAD of the aerosol inside the chamber was also estimated from the particle size distribution of the raw powder. The relative difference between the measured MMAD and the calculated value was less than 15%. The corresponding relative difference between the measured geometrical SD and the calculated value was found to be less than 26%.


Asunto(s)
Aerosoles , Asma/diagnóstico , Pruebas de Provocación Bronquial/instrumentación , Diagnóstico por Computador , Nebulizadores y Vaporizadores , Enfermedades Profesionales/diagnóstico , Administración por Inhalación , Alérgenos , Pruebas de Provocación Bronquial/métodos , Relación Dosis-Respuesta Inmunológica , Diseño de Equipo , Estudios de Evaluación como Asunto , Humanos , Tamaño de la Partícula , Programas Informáticos
9.
Toxicol Lett ; 214(2): 109-19, 2012 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-22944471

RESUMEN

Nano-aerosols composed of large agglomerates (LA) (>100nm) are more likely to promote pulmonary clearance via macrophages phagocytosis. Small agglomerates (SA) (<100nm) seem to escape this first defense mechanism and are more likely to interact directly with biological material. These different mechanisms can influence pulmonary toxicity. This hypothesis was evaluated by comparing the relative pulmonary toxicity induced by aerosolized nano-TiO(2) showing two different agglomeration states: SA (<100nm) and LA (>100nm) at mass concentrations of 2 or 7mg/m(3). Groups of Fisher 344 male rats were nose-only exposed for 6h. The median number aerodynamic diameters were 30 and 185nm at 2mg/m(3), and 31 and 194nm at 7mg/m(3). We found in rat's bronchoalveolar lavage fluids (BALF) a significant 2.1-fold increase in the number of neutrophils (p<0.05) in the group exposed to the 7mg/m(3) LA nano-aerosol suggesting a mild inflammatory response. Rats exposed to the 7mg/m(3) SA nano-aerosol showed a 1.8-fold increase in LDH activity and 8-isoprostane concentration in BALF, providing evidence for cytotoxic and oxidative stress effects. Our results indicate that biological responses to nanoparticles (NP) might depend on the dimension and concentration of NP agglomerates.


Asunto(s)
Pulmón/efectos de los fármacos , Nanopartículas/toxicidad , Titanio/toxicidad , Administración por Inhalación , Aerosoles/toxicidad , Animales , Líquido del Lavado Bronquioalveolar/citología , Citocinas/metabolismo , Pulmón/inmunología , Pulmón/patología , Masculino , Microscopía Electrónica de Transmisión , Nanopartículas/ultraestructura , Tamaño de la Partícula , Ratas , Ratas Endogámicas F344 , Titanio/administración & dosificación , Difracción de Rayos X
10.
Plant Physiol ; 71(2): 400-3, 1983 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16662837

RESUMEN

The degrees of freezing tolerance acquired by winter wheat (Triticum aestivium L.) and rye (Secale cereale L. cv Puma) were similar following a 4-week cold conditioning and a 24-hour desiccation stress. Soluble proteins were extracted from shoots of cold-conditioned or desiccation-stressed seedlings and electrophoresed on sodium dodecyl sulfate-polyacrylamide gels. Quantitative changes in the electrophoretic patterns of the soluble proteins of the different cultivars grown in different environments were detected, but the changes were not equivalent following cold conditioning and desiccation stress. The abundance of two polypeptide bands showed a significant increase correlated to the degree of freezing tolerance and, hence, the polypeptides in these bands may play a role in the development of freezing tolerance.

11.
Plant Physiol ; 69(1): 250-5, 1982 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16662169

RESUMEN

Exposure of seedlings of winter rye (Secale cereale L., cv. Puma) for 2 weeks or 24 hours to desiccation stress (40% relative humidity) at room temperature (21 degrees C) in the dark induced degrees of freezing and drought tolerance in the plumules comparable to those produced by cold conditioning for 2 weeks at 3 degrees C. The induction was associated with repression of growth and could not be produced in plumules excised from the seedlings indicating a requirement for translocation of nutrients from the endosperm. Rapid increase in osmotic pressure, soluble proteins, and phospholipids in plumules in association with the development of freezing and drought tolerance and the requirement of endosperm suggested diversion of nutrient from use in extension growth, to use in augmentation of protoplasm in plumule cells. Since cold acclimation slowed or arrested growth and is associated with augmentation of protoplasm, it is suggested that the common element in the induction of freezing tolerance by cold and drought is the necessity for producing a condition of augmented protoplasm and membranes in cells thus reinforcing a similar conclusion reached from seasonal studies on woody plants.

12.
Plant Physiol ; 69(1): 256-8, 1982 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16662170

RESUMEN

Exposure of six wheat (Triticum aestivum L.) and one rye (Secale cereale L.) cultivar to 40% relative humidity for 24 hours induced the same degree of freezing tolerance in seedling epicotyls as did cold conditioning for 4 weeks at 2 degrees C.Frost hardiness varietal relationships were the same in desiccation-stressed and cold-hardened seedlings. Drought stress could, therefore, be used as a rapid and simple method for inducing frost hardiness in seedling shoots in replacement of cold conditioning.

13.
Plant Physiol ; 76(3): 595-8, 1984 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16663889

RESUMEN

A number of defined desiccation treatments without low temperature exposure were able to induce freezing tolerance in 20 cultivars of winter cereals. A maximal degree of freezing tolerance was induced in epicotyls at 24 degrees C in 24 hours at 40% relative humidity in rye and wheat, 7 days at 54% RH in barley, and 4 days at 70% RH in oats. Freezing tolerance was not correlated to water content of the plants after desiccation treatment but was related to the genetic capacity of the cultivars to frost harden. Levels of freezing tolerance induced by desiccation were similar to those induced by cold acclimation in rye and wheat, but considerably less in barley and oats. This is associated with a more rapid desiccation injury in barley and oats, precluding the completion of the hardening process.

14.
Eur Respir J ; 5(7): 887-90, 1992 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-1499715

RESUMEN

We have previously designed a system for exposure to particles and described the preliminary results in 20 subjects exposed to occupational sensitizers in powder form (Cloutier Y, et al. - Eur Respir J, 1989; 2: 769). Modifications have been made to the particles generator, exposure chamber and sampling ports. Furthermore, in order to improve the stability of concentrations in the exposure chamber and to make the system easy to operate by a technician, it has been completely automated using closed-loop feedback regulated by a computer program.


Asunto(s)
Asma/diagnóstico , Cámaras de Exposición Atmosférica , Pruebas de Provocación Bronquial/instrumentación , Enfermedades Profesionales/diagnóstico , Aerosoles , Diseño de Equipo , Humanos
15.
Eur Respir J ; 1(6): 540-6, 1988 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-3169223

RESUMEN

We investigated the effects of particles of sawdust delivered through a special device at known concentrations (close to the threshold limit value-short term exposure limit (TLV-STEL) of 10 mg.m-3) on FEV1 and PC20 in 12 asthmatic subjects free of clinical sensitization to this product. Subjects were studied over two days (day 1: exposure to sawdust; day 2: sham exposure) in random order with a maximum interval of 1 week. On each day, after the assessment of spirometry and PC20, subjects underwent exposure to sawdust or sham exposure. Sawdust was inhaled for a total of 30 min at average concentrations varying from 8.0 to 19.3 mg.m-3 (mean = 11.5 mg.m-3). Twenty-five to 39.7% (mean = 34.6%) of inhaled particles had a diameter less than 10 mu (diameter allowing deposition in the trachea and lower respiratory tract). At the end of each period of exposure, FEV1 was assessed. After recovery, the second PC20 was obtained. Serial measurements of FEV1 were carried out every hour for up to 6 h after the end of exposure. At that time, PC20 was reassessed. Only one subject showed an acute bronchoconstriction immediately after exposure to sawdust (maximum fall of 14% in FEV1) with complete recovery 10 min later. Overall, inhalation of sawdust did not modify PC20 by comparing the mean result of the first test with the second and the third assessments. Also, the mean changes in PC20 at each interval after exposure to sawdust were not significantly different from the variations in PC20 on the sham day.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Asma/diagnóstico , Pruebas de Provocación Bronquial , Histamina , Enfermedades Profesionales/diagnóstico , Adulto , Anciano , Espasmo Bronquial/diagnóstico , Contaminantes Ambientales , Femenino , Volumen Espiratorio Forzado , Humanos , Masculino , Persona de Mediana Edad
16.
Am Rev Respir Dis ; 145(3): 582-7, 1992 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-1546838

RESUMEN

The diagnosis of isocyanate-induced occupational asthma can be made by exposing subjects to isocyanates in small challenge rooms. There are, however, several pitfalls inherent in this procedure. Isocyanate concentrations may not remain stable throughout the exposure and may exceed the recommended TLV ceiling of 20 ppb. This can induce irritant or unduly severe bronchial reactions. To overcome these problems, a closed-circuit apparatus for generating isocyanates in a gaseous form was developed; it was assessed in 20 subjects suspected of having isocyanate-induced asthma. Subjects were tested using both the small challenge room method and the new closed-circuit method in a randomized sequential way. Isocyanate concentrations were more stable with the closed-circuit apparatus than with the challenge room method (mean of individual variance of 6.3 and 61.8, respectively; p less than 0.001). The percentage of the total exposure time during which concentrations were above 20 ppb was reduced from 11.3 to 4.5% (p less than 0.001). The two methods yielded the same number of positive and negative responses, except for one subject who did not have a positive reaction when tested with the challenge room method. The pattern and magnitude of asthmatic reactions were similar for both methods. However, the duration of exposure was shorter with the challenge room method than with the closed-circuit methods (p = 0.04).


Asunto(s)
Pruebas de Provocación Bronquial/métodos , Cianatos , Ambiente Controlado , Administración por Inhalación , Asma/inducido químicamente , Asma/diagnóstico , Pruebas de Provocación Bronquial/instrumentación , Cianatos/administración & dosificación , Cianatos/efectos adversos , Diseño de Equipo , Estudios de Evaluación como Asunto , Humanos , Enfermedades Profesionales/inducido químicamente , Enfermedades Profesionales/diagnóstico , Pruebas Cutáneas , Espirometría
17.
Biochemistry ; 18(20): 4301-8, 1979 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-114212

RESUMEN

The photoreaction center from Rhodospirillum rubrum contains about 90% protein, 6% pigment, mere traces of lipids, and no cytochromes. It also contains at least 1 mol of ubiquinone and 1 iron atom per mol. Its three-component polypeptide chains were isolated by preparative electrophoresis, and their molar stoichiometry was established as 1:1:1. The amino acid composition of the photoreaction center from strain S1 and from its subunits is reported. The protein as a whole contains about 65% nonpolar residues, and the degree of hydrophobicity of its subunits is alpha less than beta less than gamma. The minimal molecular weight based on the extinction coefficient and on the amino acid content is 90 000. This corresponds to a half-cystine mole number of 6.


Asunto(s)
Proteínas Bacterianas/análisis , Fotosíntesis , Rhodospirillum rubrum/análisis , Aminoácidos/análisis , Hierro/análisis , Sustancias Macromoleculares , Peso Molecular , Pigmentos Biológicos/análisis , Ubiquinona/análisis
18.
Eur Respir J ; 12(4): 885-8, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9817163

RESUMEN

In occupational challenge tests with isocyanate vapours, bronchial responsiveness is determined by the total dose rather than the concentration or duration of exposure. Whether the same applies for high molecular weight (HMW) agents in powder form is unknown. The aim of this study was to determine whether the total dose of HMW agents in powder form is responsible for the immediate reaction documented in specific challenge tests. Included in the study were nine subjects (seven males and two females) with a diagnosis of occupational asthma proved by specific challenge tests carried out on a preliminary visit. Two challenge tests (using a closed-circuit exposure chamber) were performed at an interval of 2 weeks; the concentrations administered in a random order on these two visits were half and double the one that had caused a 20% fall in forced expiratory volume in one second (FEV1) on a preliminary visit. The duration of exposure was adjusted until a significant fall in FEV1 (target of 20%) occurred. The two concentrations obtained were significantly different, by 2.07+/-0.36-fold (SD). The observed durations of exposure leading to a 20% fall in FEV1 on the two visits also differed significantly by 0.46+/-0.32-fold. Consequently, the cumulative efficient doses were not significantly different between the two visits: 12+/-5.4 and 9+/-5 mg x mL(-1) x min(-1), respectively. The corresponding cumulative dose ratio was 0.96+/-0.61. The expected duration of exposure (10.8+/-24 min) was not significantly different from the observed duration (5.4+/-9 min). The mean and 95% confidence interval for the difference in concentration between the two visits was 1.83-fold (1.48-2.21). In conclusion, the total dose rather than the concentration or duration of exposure per se determines bronchial responsiveness to high molecular weight agents in powder form.


Asunto(s)
Contaminantes Atmosféricos/efectos adversos , Asma/etiología , Hiperreactividad Bronquial/etiología , Pruebas de Provocación Bronquial , Sustancias Peligrosas/efectos adversos , Enfermedades Profesionales/etiología , Adulto , Aerosoles/efectos adversos , Contaminantes Atmosféricos/análisis , Contaminantes Atmosféricos/química , Asma/fisiopatología , Hiperreactividad Bronquial/diagnóstico , Relación Dosis-Respuesta Inmunológica , Femenino , Harina/efectos adversos , Harina/análisis , Ajo/efectos adversos , Ajo/química , Humanos , Masculino , Persona de Mediana Edad , Peso Molecular , Enfermedades Profesionales/fisiopatología , Tamaño de la Partícula , Plantas Medicinales , Psyllium/efectos adversos , Psyllium/análisis , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Eur Respir J ; 16(4): 729-30, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11106220

RESUMEN

Isocyanates are a frequent cause of occupational asthma. Specific inhalation challenges are often required to confirm the diagnosis. The inhaled concentration has to be assessed during this procedure. However, the respiratory retention of di-isocyanate has not, to the authors knowledge, been evaluated in humans. The existence of a closed-circuit apparatus, designed to carry out these challenges, makes it possible to assess the dose. The respiratory retention of hexamethylene di-isocyanate (HDI) generated in vapour form, in both normal subjects (n=4) and subjects referred for the investigation of occupational asthma due to HDI in whom the diagnosis was excluded (n=5), was assessed. The latter group included four subjects with nonoccupational asthma. The HDI was generated at concentrations varying 5.1-15.2 ppb. The expired concentrations of HDI during such challenges varied 1.4-5.3 ppb. Therefore, the respiratory retention was 61-90%. To conclude, the majority of inhaled hexamethylene di-isocyanate vapour is retained within the airways and/on lung parenchyma.


Asunto(s)
Asma/inducido químicamente , Isocianatos/efectos adversos , Enfermedades Profesionales/inducido químicamente , Pruebas de Provocación Bronquial , Humanos , Isocianatos/administración & dosificación
20.
Am Rev Respir Dis ; 147(5): 1287-90, 1993 May.
Artículo en Inglés | MEDLINE | ID: mdl-8387256

RESUMEN

There is no information on the relative role of dose, concentration, and duration of exposure in determining the magnitude of the bronchial response in subjects with isocyanate-induced asthma. Four subjects with asthma induced by toluene diisocyanate (TDI) were challenged using a recently described closed-circuit exposure chamber in which stable concentrations of TDI monomer can be generated. Each subject was challenged using various concentrations and durations of exposure on separate days. They were all exposed on three to four occasions to the same dose that had been shown to cause a 20% fall in FEV1 at a concentration of 15 ppb (DR15ppb) by varying the concentration (5, 10, 15, and 20 ppb) and durations (1 to 90 min), making sure that the total dose (concentration x duration) remained constant. They were also exposed to lower total doses by modifying the concentration and the duration on the remaining visits. Exposing subjects to the same DR15 ppb by modifying the concentration or the duration resulted in falls in FEV1 > or = 20%, except in one instance. Exposing subjects to doses lower than DR15 ppb, even at higher concentrations or for longer periods than in the challenges used for obtaining the DR15 ppb always caused falls in FEV1 < 20%. We conclude that the main determinant of bronchial responsiveness to TDI is not concentration nor duration of exposure per se but the product of both factors, that is, total dose.


Asunto(s)
Asma/fisiopatología , Pruebas de Provocación Bronquial , 2,4-Diisocianato de Tolueno/efectos adversos , Adulto , Asma/inducido químicamente , Femenino , Volumen Espiratorio Forzado , Humanos , Masculino , Cloruro de Metacolina , Persona de Mediana Edad , 2,4-Diisocianato de Tolueno/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA