Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Stroke Cerebrovasc Dis ; 30(8): 105912, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34130105

RESUMEN

BACKGROUND/OBJECTIVE: While postoperative stroke is a known complication of Transcatheter Aortic Valve Implantation (TAVI), predictors of early stroke occurrence have not been specifically reviewed. The objective of this study was to estimate the predictors and incidence of stroke during the first 30 days post-TAVI. METHODS: A cohort of 506 consecutive patients having undergone TAVI between January 2017 and June 2019 was extracted from a prospective database. Preoperative, intraoperative and postoperative characteristics were analyzed by univariate analysis followed by logistic regression to find predictors of the occurrence of stroke or death within the first 30 days after the procedure. RESULTS: Incidence of stroke within 30 days post-TAVI was 4.9%, [CI 95% 3.3-7.2], i.e., 25 strokes. Four out of the 25 patients (16%) with a stroke died within 30 days post-TAVI. After logistic regression analysis, the predictors of early stroke related to TAVI were: CHA2Ds2VASc score ≥ 5 (odds ratio [OR] 2.62; 95% CI: 1.06-6.49; p = .037), supra-aortic access vs. femoral access (OR: 9.00, 95%CI: 2.95-27.44; p = .001) and introduction post-TAVI of a single vs. two or three antithrombotic agents (OR: 5.13; CI 95%: 1.99 to 13.19; p = .001). Over the 30-day period, bleeding occurred in 28 patients (5.5%), in 25 of whom, it was associated with femoral or iliac artery access injury. Anti-thrombotic regimen was not associated with bleeding; two patients out of 48 (4.1%) bled with a single anti-thrombotic regimen vs. 26 patients out of 458 (5.6%) with a dual or triple anti-thrombotic regimen (p = 0.94). The overall 30-day mortality rate was 3.9%, [95% CI 2.5-6.0]. Patients with a single post-TAVI antithrombotic agent (OR: 44.07 [CI 95% 13.45-144.39]; p < .0001) and patients with previous coronary artery bypass surgery or coronary artery stenting (OR: 6.16, [CI 95% 1.99-21.29]; p = .002) were at significantly higher risk of death within the 30-day period. CONCLUSION: In this large-scale single-center retrospective study, a single post-TAVI antithrombotic regimen independently predicted occurrence of early stroke or death. Dual or triple antithrombotic regimen was not associated with a higher risk of bleeding and should be considered as an option in patients undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fibrinolíticos/efectos adversos , Accidente Cerebrovascular/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Bases de Datos Factuales , Quimioterapia Combinada , Femenino , Fibrinolíticos/administración & dosificación , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/mortalidad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
3.
J Card Surg ; 28(6): 632-4, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23656221

RESUMEN

Management of late sternal dehiscence is challenging and time consuming. Although numerous techniques exist including rewiring and titanium plates screwing to stabilize the sternum, we describe an alternative technique by using four titanium clips and one connecting bar.


Asunto(s)
Mediastinitis/complicaciones , Procedimientos de Cirugía Plástica/métodos , Prótesis e Implantes , Esternotomía/efectos adversos , Dehiscencia de la Herida Operatoria/cirugía , Procedimientos Quirúrgicos Torácicos/métodos , Titanio , Anciano , Desbridamiento , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Costillas/cirugía , Esternotomía/métodos , Factores de Tiempo , Resultado del Tratamiento
4.
JTCVS Open ; 16: 401-418, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38204662

RESUMEN

Objective: The Evaluation of Transit-Time Flow in Coronary Artery Disease Surgery (EFCAD) registry aims to assess the influence of transit-time flow measurement (TTFM) in daily practice. Methods: EFCAD is a prospective, multicenter study involving 9 centers performing TTFM during isolated coronary artery bypass grafting. Primary end point was occurrence and risk factors of major adverse cardiac events, including perioperative myocardial infarction, urgent postoperative coronary angiogram and/or revascularization, and hospital mortality. Secondary end points were rate of graft revision during surgery and factors affecting graft flow. We respected the limit values set by the experts: mean graft flow >15 mL/minute and pulsatility index ≤5. Results: Between May 2017 and March 2021, 1616 patients were registered in the EFCAD database. After review, 1414 were included for analyses. Of those, 1176 were eligible for primary end point analysis. Graft revision, mainly due to inadequate TTFM values, occurred in 2% (29 patients). The primary end point occurred in 46 (3.9%) patients, and it was related with left anterior descending artery graft flow ≤15 mL/minute (odds ratio, 3.64; P < .001). Graft flow was related with number of grafts (3 vs 1-2, ß = -1.6; 4-6 vs 1-2, ß = -4.1; P < .001; ß > 0 indicates higher flow), and graft origin (aorta vs Y, ß = 9.2; in situ left internal thoracic artery vs Y, ß = 3.2; in situ right internal thoracic artery vs Y, ß = 2.3; P < .001). Conclusions: Data from EFCAD study suggest that TTFM is reliable to evaluate graft flow, and acceptance of inadequate flow on left anterior descending artery anastomosis influence postoperative outcomes. In our opinion, TTFM assessment should be routinely used in coronary artery bypass procedures, even if interpretation depends on learning curves.

5.
J Physiol ; 590(17): 4307-19, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22802584

RESUMEN

Fibroblasts play a major role in heart physiology. They are at the origin of the extracellular matrix renewal and production of various paracrine and autocrine factors. In pathological conditions, fibroblasts proliferate, migrate and differentiate into myofibroblasts leading to cardiac fibrosis. This differentiated status is associated with changes in expression profile leading to neo-expression of proteins such as ionic channels. The present study investigates further electrophysiological changes associated with fibroblast differentiation focusing on the activity of voltage-gated sodium channels in human atrial fibroblasts and myofibroblasts. Using the patch clamp technique we show that human atrial myofibroblasts display a fast inward voltage gated sodium current with a density of 13.28 ± 2.88 pA pF(-1) whereas no current was detectable in non-differentiated fibroblasts. Quantitative RT-PCR reveals a large amount of transcripts encoding the Na(v)1.5 α-subunit with a fourfold increased expression level in myofibroblasts when compared to fibroblasts. Accordingly, half of the current was blocked by 1 µm of tetrodotoxin and immunocytochemistry experiments reveal the presence of Na(v)1.5 proteins. Overall, this current exhibits similar biophysical characteristics to sodium currents found in cardiac myocytes except for the window current that is enlarged for potentials between -100 and -20 mV. Since fibrosis is one of the fundamental mechanisms implicated in atrial fibrillation, it is of great interest to investigate how this current could influence myofibroblast properties. Moreover, since several Na(v)1.5 mutations are related to cardiac pathologies, this study offers a new avenue on the fibroblasts involvement of these mutations.


Asunto(s)
Atrios Cardíacos/citología , Atrios Cardíacos/metabolismo , Miofibroblastos/citología , Miofibroblastos/metabolismo , Canal de Sodio Activado por Voltaje NAV1.5/metabolismo , Anciano , Anciano de 80 o más Años , Diferenciación Celular , Células Cultivadas , Fenómenos Electrofisiológicos , Femenino , Fibroblastos/citología , Fibroblastos/metabolismo , Expresión Génica , Células HEK293 , Humanos , Masculino , Persona de Mediana Edad , Mutación , Canal de Sodio Activado por Voltaje NAV1.5/química , Canal de Sodio Activado por Voltaje NAV1.5/genética , Técnicas de Placa-Clamp , Subunidades de Proteína , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
6.
Int J Cardiol ; 368: 56-61, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-35944771

RESUMEN

BACKGROUND: The present study is a sub-analysis of the multicenter, randomized PERSIST-AVR trial (PERceval Sutureless Implant versus Standard Aortic Valve Replacement) comparing the in-hospital and 1-year results of sutureless versus conventional stented bioprostheses in isolated surgical aortic valve replacement (SAVR) within two different surgical approaches: mini-sternotomy (MS) and full-sternotomy (FS). METHODS: A total of 819 patients (per-protocol population) underwent preoperative randomization to sutureless or stented biological valve at 47 centers worldwide. Sub-analysis on isolated SAVR was performed. Results were compared between sutureless and stented within the two different surgical approaches. RESULTS: 285 patients were implanted with Perceval (67% in MS) and 293 with stented valves (65% in MS). Sutureless group showed significantly reduced surgical times both in FS and MS. In-hospital results show no differences between Perceval and stented valves in FS, while a lower incidence of new-onset of atrial fibrillation (3.7% vs 10.8%) with Perceval in MS. After 1-year, use of sutureless valve showed a significant reduction of MACCE (5.2% vs 10.8%), stroke rate (1.0% vs 5.4%), new-onset of atrial fibrillation (4.2% vs 11.4%) and re-hospitalizations (21.8 days vs 47.6 days), compared to stented valves but presented higher rate of pacemaker implantation (11% vs 1.6%). CONCLUSIONS: Sutureless bioprosthesis showed significantly reduced procedural times during isolated SAVR in both surgical approaches. Patients with sutureless valves and MS access showed also better 1-year outcome regarding MACCEs, stroke, re-hospitalization and new-onset atrial fibrillation, but presented a higher rate of permanent pacemaker implantation compared to patients with stented bioprosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Esternotomía/métodos , Resultado del Tratamiento
7.
Front Cardiovasc Med ; 9: 844876, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35252408

RESUMEN

OBJECTIVE: Sutureless aortic valves are an effective option for aortic valve replacement (AVR) showing non-inferiority to standard stented aortic valves for major cardiovascular and cerebral events at 1-year. We report the 1-year hemodynamic performance of the sutureless prostheses compared with standard aortic valves, assessed by a dedicated echocardiographic core lab. METHODS: Perceval Sutureless Implant vs. Standard Aortic Valve Replacement (PERSIST-AVR) is a prospective, randomized, adaptive, open-label trial. Patients undergoing AVR, as an isolated or combined procedure, were randomized to receive a sutureless [sutureless aortic valve replacement (Su-AVR)] (n = 407) or a stented sutured [surgical AVR (SAVR)] (n = 412) bioprostheses. Site-reported echocardiographic examinations were collected at 1 year. In addition, a subgroup of the trial population (Su-AVR n = 71, SAVR = 82) had a complete echocardiographic examination independently assessed by a Core Lab (MedStar Health Research Institute, Washington D.C., USA) for the evaluation of the hemodynamic performance. RESULTS: The site-reported hemodynamic data of stented valves and sutureless valves are stable and comparable during follow-up, showing stable reduction of mean and peak pressure gradients through one-year follow-up (mean: 12.1 ± 6.2 vs. 11.5 ± 4.6 mmHg; peak: 21.3 ± 11.4 vs. 22.0 ± 8.9 mmHg). These results at 1-year are confirmed in the subgroup by the core-lab assessed echocardiogram with an average mean and peak gradient of 12.8 ± 5.7 and 21.5 ± 9.1 mmHg for Su-AVR, and 13.4 ± 7.7 and 23.0 ± 13.0 mmHg for SAVR. The valve effective orifice area was 1.3 ± 0.4 and 1.4 ± 0.4 cm2 at 1-year for Su-AVR and SAVR. These improvements are observed across all valve sizes. At 1-year evaluation, 91.3% (n = 42) of patients in Su-AVR and 82.3% in SAVR (n = 51) groups were free from paravalvular leak (PVL). The rate of mild PVL was 4.3% (n = 2) in Su-AVR and 12.9% (n = 8) in the SAVR group. A similar trend is observed for central leak occurrence in both core-lab assessed echo groups. CONCLUSION: At 1-year of follow-up of a PERSIST-AVR patient sub-group, the study showed comparable hemodynamic performance in the sutureless and the stented-valve groups, confirmed by independent echo core lab. Perceval sutureless prosthesis provides optimal sealing at the annulus with equivalent PVL and central regurgitation extent rates compared to sutured valves. Sutureless valves are therefore a reliable and essential technology within the modern therapeutic possibilities to treat aortic valve disease.

8.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-35290444

RESUMEN

OBJECTIVES: Sutureless aortic valves demonstrated non-inferiority to standard stented valves for major cardiovascular and cerebral events at 1 year after aortic valve replacement. We aim to assess the factors correlating with permanent pacemaker implantation (PPI) in both cohorts. METHODS: PERSIST-AVR is a prospective, randomized, open-label trial. Patients undergoing aortic valve replacement were randomized to receive a sutureless aortic valve replacement (Su-AVR) or stented sutured bioprosthesis (SAVR). Multivariable analysis was performed to identify possible independent risk factors associated with PPI. A logistic regression analysis was performed to estimate the risk of PPI associated to different valve size. RESULTS: The 2 groups (Su-AVR; n = 450, SAVR n = 446) were well balanced in terms of preoperative risk factors. Early PPI rates were 10.4% in the Su-AVR group and 3.1% in the SAVR. PPI prevalence correlated with valve size XL (P = 0.0119) and preoperative conduction disturbances (P = 0.0079) in the Su-AVR group. No predictors were found in the SAVR cohort. Logistic regression analysis showed a significantly higher risk for PPI with size XL compared to each individual sutureless valve sizes [odds ratio (OR) 0.272 vs size S (95%confidence interval 0.07-0.95), 0.334 vs size M (95% CI 0,16-0; 68), 0.408 vs size L (95% CI 0,21-0.81)] but equivalent risk of PPI rates for all other combination of valve sizes. CONCLUSIONS: Su-AVR is associated with higher PPI rate as compared to SAVR. However, the increased PPI rate appears to be size-dependent with significant higher rate only for size XL. The combination of preoperative conduction disorder and a size XL can lead to a higher probability of early PPI in Su-AVR. CLINICAL TRIAL REGISTRATION NUMBER: NCT02673697.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Resultado del Tratamiento
9.
Am J Respir Cell Mol Biol ; 44(1): 83-90, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20203293

RESUMEN

In cystic fibrosis (CF), abnormal control of cellular Ca(2+) homeostasis is observed. We hypothesized that transient receptor potential canonical (TRPC) channels could be a link between the abnormal Ca(2+) concentrations in CF cells and cystic fibrosis transmembrane conductance regulator (CFTR) dysfunction. We measured the TRPC and CFTR activities (using patch clamp and fluorescent probes) and interactions (using Western blotting and co-immunoprecipitation) in CF and non-CF human epithelial cells treated with specific and scrambled small interfering RNA (siRNA). The TRPC6-mediated Ca(2+) influx was abnormally increased in CF compared with non-CF cells. After correction of abnormal F508 deletion (del)-CFTR trafficking in CF cells, the level of TRPC6-dependent Ca(2+) influx was also normalized. In CF cells, siRNA-TRPC6 reduced this abnormal Ca(2+) influx. In non-CF cells, siRNA-TRPC6 reduced the Ca(2+) influx and activity wild-type (wt)-CFTR. Co-immunoprecipitation experiments revealed TRPC6/CFTR and TRPC6/F508 del-CFTR interactions in CF or non-CF epithelial cells. Although siRNA-CFTR reduced the activity of wt-CFTR in non-CF cells and of F508 del-CFTR in corrected CF cells, it also enhanced TRPC6-dependent Ca(2+) influx in non-CF cells, mimicking the results obtained in CF cells. Finally, this functional and reciprocal coupling between CFTR and TRPC6 was also detected in non-CF ciliated human epithelial cells freshly isolated from lung samples. These data indicate that TRPC6 and CFTR are functionally and reciprocally coupled within a molecular complex in airway epithelial human cells. Because this functional coupling is lost in CF cells, the TRPC6-dependent Ca(2+) influx is abnormal.


Asunto(s)
Señalización del Calcio , Calcio/metabolismo , Regulador de Conductancia de Transmembrana de Fibrosis Quística/metabolismo , Fibrosis Quística/metabolismo , Células Epiteliales/metabolismo , Mucosa Respiratoria/metabolismo , Canales Catiónicos TRPC/metabolismo , Western Blotting , Línea Celular , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Células Epiteliales/patología , Femenino , Homeostasis , Humanos , Inmunoprecipitación , Masculino , Potenciales de la Membrana , Microscopía Fluorescente , Persona de Mediana Edad , Mutación , Técnicas de Placa-Clamp , Unión Proteica , Interferencia de ARN , Mucosa Respiratoria/patología , Canales Catiónicos TRPC/genética , Canal Catiónico TRPC6 , Factores de Tiempo
10.
J Heart Valve Dis ; 20(2): 168-70, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21560816

RESUMEN

Traumatic aortic valve rupture is an extremely rare complication of non-penetrating cardiac injury, and may be caused by a tear or avulsion of the cusp or commissure. Transesophageal echocardiography represents the most important tool for evaluating the nature and extent of such traumatic lesions. The case is reported of a 74-year-old male who had sustained a non-penetrating chest injury in a motor vehicle accident, and suffered from aortic regurgitation as a result of rupture of the normal aortic valve. A primary valve repair was performed using an autologous pericardium patch.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos , Lesiones Cardíacas/cirugía , Pericardio/trasplante , Heridas no Penetrantes/cirugía , Accidentes de Tránsito , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/lesiones , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Ecocardiografía Transesofágica , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/fisiopatología , Humanos , Masculino , Rotura , Trasplante Autólogo , Resultado del Tratamiento , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/etiología , Heridas no Penetrantes/fisiopatología
11.
J Thorac Cardiovasc Surg ; 161(3): 920-932, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33478837

RESUMEN

OBJECTIVE: Sutureless aortic valves are a novel option for aortic valve replacement. We sought to demonstrate noninferiority of sutureless versus standard bioprostheses in severe symptomatic aortic stenosis. METHODS: The Perceval Sutureless Implant Versus Standard-Aortic Valve Replacement is a prospective, randomized, adaptive, open-label trial. Patients were randomized (March 2016 to September 2018) to aortic valve replacement with a sutureless or stented valve using conventional or minimally invasive approach. Primary outcome was freedom from major adverse cerebral and cardiovascular events (composite of all-cause death, myocardial infarction, stroke, or valve reintervention) at 1 year. RESULTS: At 47 centers (12 countries), 910 patients were randomized to sutureless (n = 453) or conventional stented (n = 457) valves; mean ages were 75.4 ± 5.6 and 75.0 ± 6.1 years, and 50.1% and 44.9% were female, respectively. Mean ± standard deviation Society of Thoracic Surgeons scores were 2.4 ± 1.7 and 2.1 ± 1.3, and a ministernotomy approach was used in 50.4% and 47.3%, respectively. Concomitant procedures were performed with similar rates in both groups. Noninferiority was demonstrated for major adverse cerebral and cardiovascular events at 1 year, whereas aortic valve hemodynamics improved equally in both groups. Use of sutureless valves significantly reduced surgical times (mean extracorporeal circulation times: 71.0 ± 34.1 minutes vs 87.8 ± 33.9 minutes; mean crossclamp times: 48.5 ± 24.7 vs 65.2 ± 23.6; both P < .0001), but resulted in a higher rate of pacemaker implantation (11.1% vs 3.6% at 1 year). Incidences of perivalvular and central leak were similar. CONCLUSIONS: Sutureless valves were noninferior to stented valves with respect to major adverse cerebral and cardiovascular events at 1 year in patients undergoing aortic valve replacement (alone or with coronary artery bypass grafting). This suggests that sutureless valves should be considered as part of a comprehensive valve program.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Procedimientos Quirúrgicos sin Sutura , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Tempo Operativo , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Estudios Prospectivos , Diseño de Prótesis , Reoperación , Índice de Severidad de la Enfermedad , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Procedimientos Quirúrgicos sin Sutura/mortalidad , Factores de Tiempo , Resultado del Tratamiento
12.
Ann Thorac Surg ; 109(2): e119-e121, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31255612

RESUMEN

We present a case of dissecting aneurysm of ascending aorta in a 15-year-old patient secondary to Takayasu arteritis with concomitant tuberculosis, with an emphasis on multimodality imaging findings and to illustrate preoperative and postoperative medical management. Antituberculosis therapy, high-dose corticosteroids, antiplatelet therapy, and ß-blockers were administrated during the initial active phase. The patient presented with acute chest pain 3 months after medical therapy initiation. We performed an ascending aorta and aortic arch replacement with branched Dacron grafts. Only a handful of similar, but not identical, cases of Takayasu arteritis with concomitant tuberculosis leading to aortic dissection have been described previously.


Asunto(s)
Aneurisma de la Aorta Torácica/etiología , Disección Aórtica/etiología , Implantación de Prótesis Vascular/métodos , Arteritis de Takayasu/complicaciones , Tuberculosis Pulmonar/complicaciones , Adolescente , Disección Aórtica/diagnóstico , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/cirugía , Humanos , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Masculino , Arteritis de Takayasu/diagnóstico , Tomografía Computarizada por Rayos X , Tuberculosis Pulmonar/diagnóstico
13.
JACC Clin Electrophysiol ; 6(12): 1551-1560, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33213815

RESUMEN

OBJECTIVES: The aim of this study was to assess the superiority of hypnosis versus placebo on pain perception and morphine consumption during typical atrial flutter (AFL) ablation. BACKGROUND: AFL ablation commonly requires intravenous opioid for analgesia, which can be associated with adverse outcomes. Hypnosis is an alternative technique with rising interest, but robust data in electrophysiological procedures are lacking. METHODS: This single center, randomized controlled trial compared hypnosis and placebo during AFl ablation. In addition to the randomized intervention, all patients were treated according to the institution's standard of care analgesia protocol (administration of 1 mg of intravenous morphine in case of self-reported pain ≥5 on an 11-point numeric rating scale or on demand). The primary endpoint was perceived pain quantified by patients using a visual analog scale. RESULTS: Between October 2017 and September 2019, 113 patients (mean age 70 ± 12 years, 21% women) were randomized to hypnosis (n = 56) or placebo (n = 57). Mean pain score was 4.0 ± 2.2 in the hypnosis group versus 5.5 ± 1.8 in the placebo group (p < 0.001). Pain perception, assessed every 5 min during the whole procedure, was consistently lower in the hypnosis group. Patients' sedation scores were also better in the hypnosis group than in the placebo group (8.3 ± 2.2 vs. 5.4 ± 2.5; p < 0.001). Finally, morphine requirements were significantly lower in the hypnosis group (1.3 ± 1.3 mg) compared with the placebo group (3.6 ± 1.8 mg; p < 0.001). CONCLUSIONS: In this first randomized trial, hypnosis during AFL ablation was superior to placebo for alleviating pain and reducing morphine consumption.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Hipnosis , Anciano , Analgésicos Opioides/uso terapéutico , Aleteo Atrial/cirugía , Femenino , Humanos , Masculino , Morfina/uso terapéutico
15.
BMJ Open ; 9(6): e026929, 2019 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-31213447

RESUMEN

INTRODUCTION: Surgical-site infection (SSI) is the second most frequent cause of healthcare-associated infection worldwide and is associated with increased morbidity, mortality and healthcare costs. Cardiac surgery is clean surgery with low incidence of SSI, ranging from 2% to 5%, but with potentially severe consequences.Perioperative skin antisepsis with an alcohol-based antiseptic solution is recommended to prevent SSI, but the superiority of chlorhexidine (CHG)-alcohol over povidone iodine (PVI)-alcohol, the two most common alcohol-based antiseptic solutions used worldwide, is controversial. We aim to evaluate whether 2% CHG-70% isopropanol is more effective than 5% PVI-69% ethanol in reducing the incidence of reoperation after cardiac surgery. METHODS AND ANALYSIS: The CLEAN 2 study is a multicentre, open-label, randomised, controlled clinical trial of 4100 patients undergoing cardiac surgery. Patients will be randomised in 1:1 ratio to receive either 2% CHG-70% isopropanol or 5% PVI-69% ethanol for perioperative skin preparation. The primary endpoint is the proportion of patients undergoing any re-sternotomy between day 0 and day 90 after initial surgery and/or any reoperation on saphenous vein/radial artery surgical site between day 0 and day 30 after initial surgery. Data will be analysed on the intention-to-treat principle. ETHICS AND DISSEMINATION: This protocol has been approved by an independent ethics committee and will be carried out according to the principles of the Declaration of Helsinki and the Good Clinical Practice guidelines. The results of this study will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals. TRIAL REGISTRATION NUMBER: EudraCT 2017-005169-33 and NCT03560193.


Asunto(s)
Antiinfecciosos Locales/administración & dosificación , Antisepsia/métodos , Procedimientos Quirúrgicos Cardíacos , Cuidados Preoperatorios/métodos , Infección de la Herida Quirúrgica/prevención & control , 2-Propanol/administración & dosificación , Administración Tópica , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Clorhexidina/administración & dosificación , Protocolos Clínicos , Etanol/administración & dosificación , Humanos , Povidona Yodada/administración & dosificación , Resultado del Tratamiento
18.
J Med Liban ; 56(3): 168-73, 2008.
Artículo en Francés | MEDLINE | ID: mdl-18792554

RESUMEN

In the heart, two types of calcium currents were described, the L- and T-type. In addition to these two types, a dihydropyridine-resistant Ca2+ component has been described to be up-regulated in rat ventricular cardiomyocytes during their differentiation- dedifferentiation process. The aim of our study is to examine if such calcium current component is present in human cardiomyocytes. The patch clamp technique was used to record Ca2+ current in atrial cells. In the presence of 2 microM nifedipine, residual current was activated (-2.7 +/- 0.7 pA/pF, n = 6) in the same voltage range as the L-type, nifedipine-sensitive Ca2+ current (-2.1 +/- 0.4 pA/pF, n = 6), but its steady-state inactivation was negatively shifted by 10 mV. This nifedipine-resistant Ca2+ current was completely blocked by 500 microM cadmium chloride and significantly enhanced by 1 microM isoproterenol (-7.5 +/- 0.5 pA/pF, n = 6; p <0.01). These results give evidence that a nifedipine-resistant Ca2+ current, similar to the one which has been shown to be developmentally expressed in rat ventricular cardiomyocytes, is observed in human atrial cells. Its molecular identity, its expression level as well as its role in pathophysiologic conditions remain to be studied.


Asunto(s)
Canales de Calcio/efectos de los fármacos , Calcio/fisiología , Atrios Cardíacos/inervación , Miocitos Cardíacos/efectos de los fármacos , Cloruro de Cadmio , Dihidropiridinas/uso terapéutico , Humanos , Técnicas In Vitro , Nifedipino/uso terapéutico , Técnicas de Placa-Clamp
20.
J Heart Valve Dis ; 15(4): 528-30, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16901049

RESUMEN

The most common repair technique for P2 prolapse is quadrangular resection of the posterior leaflet associated with a plication of the mitral annulus or with a sliding plasty. Although effective, these techniques do not respect the anatomy of the mitral valve, especially the physiological role of the posterior leaflet. Herein is described another technique which does not include P2 removal, thus preserving the posterior leaflet mobility. This technique represents a new approach to mitral valve repair that respects the motion of the two leaflets, allowing a more physiological opening of the mitral valve.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/cirugía , Válvula Mitral/anatomía & histología , Válvula Mitral/cirugía , Anciano , Presión Sanguínea , Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Estudios de Seguimiento , Humanos , Periodo Intraoperatorio , Persona de Mediana Edad , Modelos Cardiovasculares , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA