Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
World J Urol ; 42(1): 280, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693433

RESUMEN

OBJECTIVE: To perform a comprehensive narrative review that will examine the risk factors and treatment outcomes of arterial pseudoaneurysm following laser flexible ureteroscopy (F-URS). METHODS: A retrospective case series and a review of literature was performed. Clinical records from three patients treated for postoperative arterial pseudoaneurysm from January of 2021 to November 2023 were identified. A comprehensive literature review was also performed. The MEDLINE and Scopus databases were searched. The analysis was made by a narrative synthesis. RESULTS: Three cases of postoperative arterial pseudoaneurysm were included, one from our center, one from Dubai, UAE, and one from Barcelona. The literature review identified six case reports, two after endocorporeal laser lithotripsy with thulium fiber laser (TFL) and four with Ho:YAG laser. All cases, from our series and literature review, presented with macroscopic hematuria and used high-power laser settings. All cases were treated by selective embolization. CONCLUSION: Ho:YAG or TFL lasers are both capable of causing arterial pseudoaneurysms following F-URS if high-power settings are used. Selective artery embolization continues to be the treatment of choice with good outcomes.


Asunto(s)
Aneurisma Falso , Litotripsia por Láser , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Litotripsia por Láser/efectos adversos , Litotripsia por Láser/métodos , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Ureteroscopía/efectos adversos , Adulto
2.
World J Urol ; 42(1): 145, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38478094

RESUMEN

INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Litotricia , Humanos , Tulio/uso terapéutico , Litotripsia por Láser/métodos , Cálculos Renales/cirugía
3.
World J Urol ; 42(1): 57, 2024 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-38280001

RESUMEN

INTRODUCTION: Both Holmium:yttrium-aluminium-garnet (Ho:YAG) laser and Thulium Fiber Laser (TFL) can effectively treat all urinary stone types. This in vitro study evaluated the ablation volume per pulse (AVP) and required energy needed to ablate 1mm3 (RE, J/mm3) of various stone types at different laser settings with TFL. METHODS: 272-µm core-diameter laser fibers (Boston Scientific©) were connected to a 50 Watts TFL generator (IPG®). An experimental setup immerged human stones of calcium oxalate monohydrate (COM), uric acid (UA), and cystine (CYS) with a single pulse lasing emission (0.5/0.8/1 J), in contact mode. Stones were dried out before three-dimensional scanning to measure AVP and deduce from the pulse energy (PE) and AVP the RE. A direct comparison with known Ho:YAG's AVP and RE was then carried out. RESULTS: AVP for COM stones was significantly greater than those for CYS stones and similar to UA stones (p = 0.02 and p = 0.06, respectively). If AVP increased with PE against COM and UA stones, AVP decreased against CYS stones. 1 J PE resulted in a threefold lower RE compared with other PE for COM stones. On the contrary, RE for CYS increased with PE, whereas PE did not had influence on RE for UA. TFL was associated with greater AVP for COM, but lower for UA and CYS stones compared to Ho:YAG laser. CONCLUSION: This in vitro study firstly describes the ablation volume per pulse and required energy to treat a cubic millimeter of three frequent human stone types, and suggest TFL could not be suited for cystine. Therefore, stone composition could be considered when choosing the laser source for lithotripsy.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Litotripsia por Láser , Nefrolitiasis , Cálculos Urinarios , Humanos , Litotripsia por Láser/métodos , Tulio , Cistina , Cálculos Urinarios/cirugía , Láseres de Estado Sólido/uso terapéutico , Holmio
4.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520528

RESUMEN

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Asunto(s)
Iluminación , Ureteroscopios , Humanos , Diseño de Equipo , Urólogos , Equipos Desechables , Ureteroscopía
5.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613608

RESUMEN

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Humanos , Holmio , Tulio , Ureteroscopía , Estudios Prospectivos , Cálculos Renales/cirugía , Rayos Láser
6.
World J Urol ; 42(1): 355, 2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38796790

RESUMEN

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Asunto(s)
Diseño de Equipo , Iluminación , Ureteroscopios , Ureteroscopía , Luz , Humanos , Solución Salina , Color
7.
World J Urol ; 42(1): 362, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38814457

RESUMEN

OBJECTIVE: To evaluate long-term surgical and functional outcomes of cystinuric patients exclusively treated with Ureteroscopy (URS). METHODS: Data from patients treated for cystine stones at a single academic center were retrospectively analyzed. The management protocol consisted of (i) treating symptomatic or > 7 mm stones, (ii) multi-staged URS for voluminous stones, (iii) referring patients to a dedicated nephrological clinic. The eGFR was calculated according to the MDRD formula. CKD category was assessed according to the NKF classification. Relevant CKD was defined as CKD category ≥ 3a. Descriptive statistics were used to analyze the cohort data. RESULTS: Data from 46 cystinuric patients treated with 332 URS were available. Median age at diagnosis and at first URS in our center were 18 and 32 years, respectively. Median follow-up was 101 months. Median number of URS and recurrences per patient were 6 and 2, respectively. The median interval between the first and the last available creatinine level was 64 months. Median first and last eGFR were 72 and 74 mL/min, respectively. Overall, 83% of patients had stable or improved renal function within the study period. Ureteral stricture occurred in 3 (6.5%) patients. CONCLUSIONS: Cystinuria requires intensive endoscopic management. Most patients treated with URS have stable or improved renal function within a long-term follow-up. CKD is a not neglectable event that potentially occurs at an early stage of life. Current findings should be considered for the surgical management of cystinuric patients.


Asunto(s)
Cistinuria , Centros de Atención Terciaria , Ureteroscopía , Humanos , Masculino , Estudios Retrospectivos , Adulto , Femenino , Adolescente , Cistinuria/complicaciones , Adulto Joven , Resultado del Tratamiento , Factores de Tiempo , Cálculos Renales/cirugía , Persona de Mediana Edad , Niño
8.
World J Urol ; 41(10): 2627-2636, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37468656

RESUMEN

BACKGROUND: The management of urolithiasis has undergone significant advancements with the introduction of pulsed lasers, particularly the holmium:yttrium-aluminum-garnet (Ho:YAG) laser, which is currently considered the gold standard in endourology. However, the Ho:YAG laser has certain limitations, such as the inability to support small laser fibers (150 µm) and the requirement of a heavy water cooling system, making it challenging to transfer between operating rooms. These limitations have led to the emergence of new laser technologies, including the thulium fiber laser (TFL) and the thulium:yttrium-aluminum-garnet laser (Tm:YAG), as potential alternatives to the Ho:YAG laser. METHODS: In this review, we aimed to evaluate the effectiveness and safety of TFL, Ho:YAG, and Tm:YAG lasers in real-life scenarios by comparing clinical trial data with laboratory findings. A literature review was conducted, and relevant in vitro studies and clinical trials until March 2023 were analyzed. RESULTS: The findings indicate that TFL has demonstrated high ablation efficiency for stones of any composition, size, and location, superior the capabilities of Ho:YAG lasers. TFL has shown superior dusting and fragmentation abilities, lower retropulsion, and increased patient safety. The laser parameters, such as ablation efficiency, speed, operative time, dust quality, retropulsion, visibility, temperature safety, and stone-free rate, were compared between laboratory studies and clinical outcomes. CONCLUSION: Although the number of studies on TFL is limited, the available evidence suggests that TFL represents a significant advancement in laser technology for lithotripsy. However, further research is needed to fully explore the implications and limitations of TFL and Tm:YAG lasers.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Urolitiasis , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio/uso terapéutico , Holmio , Urolitiasis/cirugía
9.
World J Urol ; 41(12): 3765-3771, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37833547

RESUMEN

BACKGROUND AND OBJECTIVE: We aimed to evaluate the concordance between the pre-settings ranges of thulium fibre laser (TFL) (Coloplast TFL Drive, Denmark) with easy-to-use graphical user interface and the laser settings used by a high-volume endo-urologist during surgical procedures. MATERIALS AND METHODS: In October 2022, we prospectively collected data of 67 patients who underwent TFL Drive (Coloplast, Denmark) for the management of urinary stones. Urothelial tumour (upper tract urinary cancer (UTUC) and bladder) 200 and 150 µm laser fibres were used for procedures. Stones characteristics (size and density) tumours and stenosis localizations, laser-on time (LOT), and laser settings were recorded. We also assessed the ablation speed (mm3/s), laser power (W), and Joules/mm3 values for each lithotripsy. RESULTS: A total 67 patients took part in the study. Median age was 52 (15-81) years. 55 (82%), 8 (12%), and 4 (6%) patients presented urinary stones, urothelial tumour, and stenosis, respectively. Median stone volume was 438 (36-6027) mm3 and median density was 988 (376-2000) HU. Median pulse energy was 0.6 (0.3-1.2), 0.8 (0.5-1) and 1 J for urinary stones, urothelial tumour and stenosis respectably. Endoscopically stone-free rate was 89%. Graphical user interface and surgeon accordance with the safety range were observed in 93.2%, 100% and 100% for urinary stones, UTUC and stenosis, respectively. CONCLUSION: During endoscopic procedures for urinary stones treatment, it is frequently needed to change laser parameters. These new TFL and GUI technology parameters remained in the pre-set security range in 94.1% of procedures.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Neoplasias , Cálculos Urinarios , Humanos , Persona de Mediana Edad , Tulio , Litotripsia por Láser/métodos , Constricción Patológica , Cálculos Urinarios/cirugía , Láseres de Estado Sólido/uso terapéutico
10.
World J Urol ; 41(8): 2119-2125, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37414942

RESUMEN

INTRODUCTION: Holmium:yttrium-aluminium-garnet (Ho:YAG) and thulium fiber (TFL) lasers are currently the two laser sources recommended for endocorporeal laser lithotripsy (ELL). Recently, the pulsed-thulium:YAG (Tm:YAG) laser was also proposed for ELL, as an answer to both Ho:YAG and TFL limitations. We aimed to evaluate the efficiency, safety, and laser settings of Tm:YAG laser in ELL during retrograde intrarenal surgery (RIRS). METHODS: A prospective study of the first 25 patients with ureteral and renal stones who underwent RIRS using the Thulio (pulsed-Tm:YAG, Dornier©, Germany) was performed in a single center. 272 µm laser fibers were used. Stone size, stone density, laser-on time (LOT) and laser settings were recorded. We also assessed the ablation speed (mm3/s), Joules/mm3 and laser power (W) values for each procedure. Postoperative results, such as stone-free rate (SFR) and zero fragments rate (ZFR) were also recorded. RESULTS: A total of 25 patients were analyzed (Table 1). The median (IQR) age was 55 (44-72) years old. Median (IQR) stone volume was 2849 (916-9153)mm3. Median (IQR) stone density was 1000 (600-1174)HU. Median (IQR) pulse energy, pulse rate and total power were 0.6 (0.6-0,8)J, 15(15-20)Hz and 12(9-16)W, respectively. All procedures used "Captive Fragmenting" pulse modulation (Table 2). The median (IQR) J/mm3 was 14,8 (6-21). The median (IQR) ablation rate was 0,75 (0,46-2)mm3/s. One postoperative complications occurred (streinstrasse). SFR and ZFR were 95% and 55%, respectively. CONCLUSION: The pulsed-Tm:YAG laser is a safe and effective laser source for lithotripsy during RIRS, using low pulse energy and low pulse frequency.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Humanos , Persona de Mediana Edad , Anciano , Láseres de Estado Sólido/uso terapéutico , Tulio/uso terapéutico , Estudios Prospectivos , Litotripsia por Láser/métodos , Cálculos Renales/cirugía , Holmio
11.
World J Urol ; 41(12): 3437-3447, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37932561

RESUMEN

PURPOSE: To provide a technological description of the new pulsed solid-state Thulium:YAG laser (Tm:YAG). In addition, current available literature on Tm:YAG lithotripsy is also reviewed. MATERIALS AND METHODS: Medline, Scopus, Embase, and Web of Science databases were used to search for Tm:YAG operating mode articles. RESULTS: Tm:YAG technology works with a laser cavity with thulium-doped YAG crystal, pumped by laser diodes. Laser beam operates at 2013 nm, with an adjustable peak power (≥ 1000 W) and the minimal fiber laser diameter is of 200 µm. It has an intermediate water absorption coefficient and peak power-pulse duration. Various pulse modulations are proposed, aiming to minimize stone retropulsion. Multiple comparative in vitro studies suggest that Tm:YAG's ability to fragment stones is similar to the one of the Ho:YAG laser; on the contrary, its ability to dust all stone types is similar to the one of the TFL, with a low retropulsion. A single in vivo study assessed Tm:YAG lithotripsy feasibility. CONCLUSIONS: The new pulsed solid-state thulium:YAG laser could represent a safe and effective compromise between Ho:YAG laser and TFL for endoscopic lithotripsy, either in retrograde intra-renal surgeries or in percutaneous nephrolithotomy.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Litotricia , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio , Holmio
12.
World J Urol ; 41(10): 2823-2831, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37587366

RESUMEN

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. METHODS: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). RESULTS: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. CONCLUSION: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Cálculos Urinarios , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio , Polvo , Litotripsia por Láser/métodos , Cálculos Urinarios/terapia
13.
Curr Opin Urol ; 33(4): 318-323, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37014757

RESUMEN

PURPOSE OF REVIEW: Nowadays, due to the increase of imaging diagnosis, we identify easily renal anomalies, and we can choose between a wide range of armamentarium to treat symptomatic stones in those challenging cases. However, there is a lack of evidence and consensus on its use. The aim of this narrative review is to collect all the available data about safety and efficacity of retrograde intrarenal surgery (RIRS) in the treatment of kidney stones associated to a renal anomaly. RECENT FINDINGS: Renal anomalies are uncommon findings and even more if it has to be associated with renal stones. After a literature review of the past 2 years, there are a small number of studies that compare the outcomes in patients who have been treated with minimally invasive modalities and they are mainly focus on RIRS. SUMMARY: It is of extreme importance to know the advances on the stone treatment in anomalous kidneys. With the development of new laser technologies, RIRS is becoming a more interesting technique with high success rate and safety. Further studies are needed to make an accurate statement about the adequate surgical technique for each renal anomaly and also, clinical trials using new laser technologies.


Asunto(s)
Divertículo , Riñón Fusionado , Cálculos Renales , Riñón Esponjoso Medular , Nefrostomía Percutánea , Humanos , Riñón Fusionado/complicaciones , Riñón Fusionado/diagnóstico por imagen , Riñón Fusionado/cirugía , Riñón Esponjoso Medular/complicaciones , Riñón Esponjoso Medular/diagnóstico por imagen , Riñón Esponjoso Medular/cirugía , Resultado del Tratamiento , Cálculos Renales/complicaciones , Cálculos Renales/diagnóstico por imagen , Cálculos Renales/cirugía , Riñón/diagnóstico por imagen , Riñón/cirugía , Estudios Retrospectivos , Nefrostomía Percutánea/métodos
14.
World J Urol ; 40(6): 1529-1535, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35246704

RESUMEN

INTRODUCTION: Thulium fiber laser (TFL) is a novel laser in the field of urology. There is no consensus for optimal parameters. As most urologists use social media, being Twitter the platform with the most dissemination in healthcare, we aim to review the preferred TFL settings chosen by the experts and, to evaluate their pros and cons. MATERIALS AND METHODS: A Twitter review was performed from November 2019 (firsts TFL experiences in urology) until October 2021 using the hashtags: "thuliumfiber", "ThuliumFiberLaser", "TFL" "soltive", "fiberdust", "OlympusUrology", "quanta_system", "IPG_Photonics", "rocamed". Only board-certified urologists were considered. The "tweets" selected include information about TFL preferred settings for stone lithotripsy and tissue ablation. Additionally, we also seek information regarding laser technique, fiber size, laser time, stone type and equipment. RESULTS: A total of 42 opinions were identified. The 23 endourologists have a median of 2.298 followers (range 202-10.000). Most comments were about TFL settings for kidney stone dusting (61%). There was a significant difference (p < 0.05) for kidney stone dusting settings (dusting, frequency, and power) between endourologists. Only 24% reported their fiber size, 4 reported the stone composition and 2 endourologists mentioned their type of ureteroscope. There was no discussion about technique used (burst or continuous) nor equipment. Surgery time was reported 3 times. CONCLUSION: There is no consensus in TFL pre-settings. When a pre-setting is proposed, it should also recommend technique to be used. Settings are personal and related to multiple factors, such as training, technique, equipment and fiber size.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Medios de Comunicación Sociales , Humanos , Láseres de Estado Sólido/uso terapéutico , Litotripsia por Láser/métodos , Tulio
15.
World J Urol ; 40(10): 2549-2553, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35861860

RESUMEN

OBJECTIVE: To evaluate the new thulium fiber laser (TFL) from Quanta System (Fiber Dust™) in terms of efficiency, safety, and laser settings in laser lithotripsy during retrograde intrarenal surgery (RIRS). METHODS: A prospective study of the first 50 patients with ureteral and renal stones who underwent RIRS using the new Fiber Dust (TFL from Quanta System, Italy) was performed in a single center. 200 µm and 150 µm laser fibers were used. Stone size, stone density, laser-on time (LOT) and laser settings were recorded. We also assessed the ablation speed (mm3/s), Joules/mm3 and laser power (W) values for each procedure. RESULTS: A total of 50 patients were analyzed. The median (IQR) age was 54.5 (43-65) years old. Median (IQR) stone volume was 347 (147-1800) mm3 and 1125 (294-4000) mm3 for ureteral and renal stones, respectively. Median (IQR) stone density was 900 (400-1500) HU for ureteral stones and 950 (725-1125) HU for renal stones. Median (IQR) pulse energy was 0.6 (0.5-1) J and 0.6 (0.5-0.9) J for ureteral and renal stones, respectively. Median (IQR) frequency for ureteral stones was 10 (10-20) Hz and for renal stones, 15 (10-20) Hz. All procedures used short pulse. There were no statistically significant differences in pulse energy, frequency, laser power or LOT in both groups. The median (IQR) J/mm3 was 8.7 (4.8-65.2) for ureteral stones vs 14.3 (7.8-24.7) for renal stones. The median (IQR) ablation rate was 0.3 (0.2-1.3) mm3/s for ureteral stones vs 0.7 (0.4-1.2) mm3/s for renal stones. Neither of those results reached the significance threshold. Overall complication rate was low in both groups, and none was related to TFL. CONCLUSION: According to our results, the new TFL laser is safe and effective for lithotripsy during RIRS, using low pulse energy and low pulse frequency.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Cálculos Ureterales , Anciano , Polvo , Humanos , Cálculos Renales/cirugía , Láseres de Estado Sólido/uso terapéutico , Litotripsia por Láser/métodos , Persona de Mediana Edad , Estudios Prospectivos , Tulio/uso terapéutico , Cálculos Ureterales/cirugía
16.
World J Urol ; 40(7): 1839-1844, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35633401

RESUMEN

PURPOSE: To compare the efficacy of conventional low power and high power holmium: yttrium aluminum-garnet (Ho: YAG) laser lithotripsy settings during retrograde intrarenal surgery (RIRS).  METHODS: The prospective study was conducted in patients undergoing RIRS for renal stones less than 2 cm diameter. Pulsed Ho:YAG laser (Lumenis® Pulse TM P120 H) was used for laser lithotripsy and the patients were randomized into low power (LP) and high power (HP) laser lithotripsy settings groups. The lasing duration, total laser energy used (Joules), laser energy used to ablate 1 mm3 of stone (Joules/mm3), operative duration, stone ablation speed (mm3/s) and stone free rate were compared. RESULTS: A total of 120 underwent RIRS with 63 and 57 patients in LP and HP group, respectively. Median stone volume and stone density were comparable between the groups. The total energy used and laser energy used to ablate 1mm3 of stone (Joules/mm3) were significantly higher in the HP group than in LP group (27.9 (16.4-46.2) J/ mm3 vs 9.7 (5.3-17.7) J/ mm3) (p < 0.01). Median (IQR) ablation speed were 0.8 (0.5-1.3) mm3/s and 0.6 (0.4-1) mm3/s in the LP and HP groups, respectively. The median lasing time, operative time and stone free rate were similar in both the groups. CONCLUSION: The total energy used and J/mm3 were lower in the LP group than in HP group with similar lasing duration, operative duration, ablation speed and stone free rate for renal stones less than 2 cm.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Holmio , Humanos , Cálculos Renales/cirugía , Láseres de Estado Sólido/uso terapéutico , Estudios Prospectivos , Ureteroscopios , Ureteroscopía
17.
World J Urol ; 40(9): 2313-2321, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35933626

RESUMEN

INTRODUCTION: Since the construction of the first laser, many companies around the world have contributed to the development of new lasers technologies. To be user-friendly, some companies have developed a pre-setting mode in their laser devices. We aimed to review and compare all laser companies' pre-settings (PS) already established in the market. MATERIALS AND METHODS: An online search of holmium:YAG (Ho:YAG) and thulium fiber laser (TFL) devices was carried out. Manual and PS mode, pulse width and pulse modulation technology data were collected. The PS parameters were collected directly from the brochure devices or by asking the companies consulting agents. RESULTS: Thirty-nine laser devices were analyzed (33 Ho:YAG and 6 TFL). The power range varies from 15 to 152 W and 35 W to 60 W for Ho:YAG and TFL, respectively. PS are present in 66% of Ho:YAG lasers and the 33% of TFL. Long-pulse modes can be modified in 12 Ho:YAG and 1 TFL lasers. The median (IQR) PS for dusting stones with Ho:YAG laser is 0.4 J (0.2-1), 21.5 Hz (5-120), and 10 W (1.5-28) for energy, frequency and power, respectively; for Ho:YAG fragmentation is 0.8 J (0.3-5), 10 (3-15) Hz and 5 (1.5-50) W for energy, frequency, and power, respectively; and for popcorn is 0.8 J (0.4-1.2), 10 Hz (6-15) and 5 W (4-18) for energy, frequency, and power, respectively. Dusting and fragmentation mode of Rocamed MH01 and EMS LaserClast 35 are programmed according to the stone type. Most of these settings do not depend on the size of the fiber being used nor the location and type of stone. For TFL, the pre-sets are divided in bladder stone, dusting, fine dusting, fragmentation, and ureteral stone. CONCLUSION: There is a huge variability regarding pre-sets offered by companies because there is no consensus. Pre-sets should provide a range to work efficacy and safety.


Asunto(s)
Láseres de Estado Sólido , Litotripsia por Láser , Cálculos de la Vejiga Urinaria , Holmio , Humanos , Láseres de Estado Sólido/uso terapéutico , Tulio
18.
World J Urol ; 40(6): 1391-1411, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35152322

RESUMEN

INTRODUCTION AND OBJECTIVES: This systematic review aims to evaluate the incidence and influencing factors of urethral stricture (US) in relation to different BPH endoscopic techniques. MATERIALS AND METHODS: We performed a systematic literature review using MEDLINE, EMBASE, and Cochrane Central Controlled Register of Trials. The incidence of US was estimated through comparative studies between different endoscopic techniques. Patients were assigned into groups according to the type of surgery (enucleation, ablation and resection group). Incidences of US were pooled using the Cochran-Mantel-Haenszel Method with the random effect model and reported as Risk Ratio (RR), 95% Confidence Intervals (CI), and p-values. RESULTS: A total of 80 studies were included for meta-analysis. The pooled incidence of US was 1.7% after enucleation, 2.1% after ablation, 3.8% after monopolar (M)-TURP and 2.1% after bipolar (B)-TURP. The incidence of US was significantly lower after Enucleation than after TURP (RR 0.58 95% CI 0.39-0.84, p = 0.004). US incidence was lower for Ablation procedures than TURP, but the difference did not reach significance (RR 0.79 95% CI 0.61-1.3, p = 0.08). However, this was significant in the subgroup of M-TURP studies (RR 0.67, 95% CI, 0.49-0.91, p = 0.01). Sub-analysis showed that the risk of US was significantly lower after Enucleation than after TURP within 12 months after surgery (RR 0.51 95% CI 0.33-0.81, p = 0.004). CONCLUSION: The study shows an increased incidence of US after TURP compared to enucleation and ablation procedures. The main factors related to increased US incidence are the use of monopolar energy, instrument caliber and duration of postoperative catheterization.


Asunto(s)
Hiperplasia Prostática , Resección Transuretral de la Próstata , Estrechez Uretral , Humanos , Masculino , Estudios Prospectivos , Próstata/cirugía , Hiperplasia Prostática/complicaciones , Hiperplasia Prostática/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Resección Transuretral de la Próstata/efectos adversos , Resección Transuretral de la Próstata/métodos , Resultado del Tratamiento , Estrechez Uretral/epidemiología , Estrechez Uretral/etiología , Estrechez Uretral/cirugía
19.
World J Urol ; 40(5): 1223-1229, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35129624

RESUMEN

PURPOSE: To analyse and report the practice, outcomes and lessons learnt from a global series of retrograde intrarenal surgery (RIRS) in a paediatric multicentre series. METHODS: A retrospective review of anonymized pooled data gathered globally from 8 centres in paediatric patients (≤ 18 years of age) who had renal stones and underwent RIRS from 2015 to 2020 was performed. Patient demographics, perioperative parameters, stone characteristics, complications and stone-free rate (SFR; defined as endoscopically stone free and/or residual fragments < 2 mm on follow up imaging) were analysed. The cohort was stratified into 3 groups by age: < 5 years (Group A), 5-10 years (Group B) and > 10 years (Group C). Overall, post-operative complication rate was 13.7%. Chi-square comparisons were used for categorical variables; analysis of variance (ANOVA) or Kruskal-Wallis tests were used for continuous variables. RESULTS: 314 patients were analysed. The mean age was 9.54 ± 4.76 years. Groups A, B and C had 67 (21.3%), 83 (26.4%) and 164 (52.2%) patients, respectively. Mean stone size was 10.7 ± 4.62 mm. Pre-stenting was performed in 155 (49.4%) of patients, ureteral access sheaths (UAS) was used in 54.5% of patients with majority (71%) utilizing holmium laser for stone fragmentation. All complications were minor (Clavien-Dindo grade 1 and 2). SFR was 75.5%. CONCLUSIONS: RIRS is acceptable as a first-line intervention in the paediatric population with reasonable efficacy and low morbidity. Complications are slightly higher in patients < 5 years of age, which should be taken into account while counselling patients.


Asunto(s)
Cálculos Renales , Uréter , Adolescente , Niño , Preescolar , Femenino , Humanos , Cálculos Renales/cirugía , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Ureteroscopía/métodos
20.
Curr Opin Urol ; 32(2): 179-184, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35013078

RESUMEN

PURPOSE OF REVIEW: Retrograde intrarenal surgery (RIRS) has always been recommended for large stones > 20 mm, using the Ho:YAG laser. The introduction of a new technology in the urological market, the thulium fiber laser (TFL) has revolutionized the endourology world because of its characteristics and significantly shorter laser-on time (LOT) and operative time, without scarifying the champ vision. The aim of this review is to evaluate the most relevant findings of the last 2 years of each laser technology, confronting Ho:YAG vs TFL, analyzing who is more suitable for performing an efficient RIRS. RECENT FINDINGS: Five full clinical trials using TFL for RIRS were found. Median LOT was between 2.8 and 34 min. All stones were similar in terms of stone volume, >500 mm3, and stone density, > 800 HU. Low complication rate, mostly Clavien-Dindo grade I and II and not related to the laser itself. One clinical trial only analyzed the efficacy of TFL for > 20 mm renal stones. SUMMARY: Based on this review, TFL performs a more efficient RIRS than the Ho:YAG laser with similar safety.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Femenino , Humanos , Cálculos Renales/tratamiento farmacológico , Cálculos Renales/cirugía , Láseres de Estado Sólido/efectos adversos , Litotripsia por Láser/efectos adversos , Masculino , Tulio/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA