RESUMEN
We present the case of a male patient on hemodialysis with a ruptured pseudoaneurysm in a brachiocephalic arteriovenous fistula (AVF) and with edema and pain in the right arm attended to in the emergency department. An ultrasonographic scan identified a ruptured pseudoaneurysm with hemorrhagic infiltration of the arm muscular tissues. We performed a percutaneous ultrasound-guided thrombin injection with an angioplasty balloon inflated in the lumen of the AVF achieving the pseudoaneurysm thrombosis. After 6 months of follow-up, the patient's arteriovenous access remains functional. Percutaneous ultrasound-guided thrombin injection assisted by an angioplasty balloon may be a good alternative to surgical intervention in the treatment of symptomatic growing pseudoaneurysms of the arteriovenous fistula with the benefit of preserving the vascular access.
Asunto(s)
Aneurisma Falso , Fístula Arteriovenosa , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Fístula Arteriovenosa/diagnóstico por imagen , Fístula Arteriovenosa/terapia , Humanos , Masculino , Diálisis Renal/efectos adversos , Trombina , Ultrasonografía IntervencionalRESUMEN
The distal arteriovenous fistula (AVF) has less complications and better patency than the proximal fistula, when it works properly. The complications of outflow of the fistula are complex, and it is necessary to analyze all solutions to solve the problem. We introduce a novel approach to solve outflow problems of a radio-cephalic AVF by straightening of the forearm cephalic vein with drainage into the median basilic vein.